Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Biol Macromol ; 242(Pt 3): 125136, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37270121

RESUMO

The industrial production of chitosan, initiated over 50 years ago, has transformed its application across diverse industries, agriculture, and medicine. To enhance its properties, numerous chitosan derivatives have been synthesized. The quaternization of chitosan has proven beneficial, as it not only enhances its properties but also imparts water solubility, expanding its potential for a wider range of applications. Specifically, the utilization of quaternized chitosan-based nanofibers has leveraged the synergistic benefits of quaternized chitosan (including hydrophilicity, bioadhesiveness, antimicrobial, antioxidant, hemostatic, and antiviral activities, as well as ionic conductivity) in combination with the distinctive characteristics of nanofibers (such as a high aspect ratio and 3D architecture). This combination has permitted numerous possibilities, spanning from wound dressings, air and water filters, drug delivery scaffolds, antimicrobial textiles, to energy storage systems and alkaline fuel cells. In this comprehensive review, we examine the preparation methods, properties, and applications of various composite fibers containing quaternized chitosan. The advantages and disadvantages of each method and composition are meticulously summarized, while relevant diagrams and figures illustrate the key findings.


Assuntos
Anti-Infecciosos , Quitosana , Hemostáticos , Nanofibras , Quitosana/farmacologia , Anti-Infecciosos/farmacologia , Água , Antibacterianos
2.
ACS Appl Mater Interfaces ; 14(49): 54527-54538, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36454041

RESUMO

Low-cost, instrument-free colorimetric tests were developed to detect SARS-CoV-2 using plasmonic biosensors with Au nanoparticles functionalized with polyclonal antibodies (f-AuNPs). Intense color changes were noted with the naked eye owing to plasmon coupling when f-AuNPs form clusters on the virus, with high sensitivity and a detection limit of 0.28 PFU mL-1 (PFU stands for plaque-forming units) in human saliva. Plasmon coupling was corroborated with computer simulations using the finite-difference time-domain (FDTD) method. The strategies based on preparing plasmonic biosensors with f-AuNPs are robust to permit SARS-CoV-2 detection via dynamic light scattering and UV-vis spectroscopy without interference from other viruses, such as influenza and dengue viruses. The diagnosis was made with a smartphone app after processing the images collected from the smartphone camera, measuring the concentration of SARS-CoV-2. Both image processing and machine learning algorithms were found to provide COVID-19 diagnosis with 100% accuracy for saliva samples. In subsidiary experiments, we observed that the biosensor could be used to detect the virus in river waters without pretreatment. With fast responses and requiring small sample amounts (only 20 µL), these colorimetric tests can be deployed in any location within the point-of-care diagnosis paradigm for epidemiological control.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanopartículas Metálicas , Humanos , Colorimetria/métodos , Ouro/química , SARS-CoV-2 , Nanopartículas Metálicas/química , Ressonância de Plasmônio de Superfície/métodos , Smartphone , Teste para COVID-19 , COVID-19/diagnóstico , Técnicas Biossensoriais/métodos
3.
Colloids Surf B Biointerfaces ; 220: 112886, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36183636

RESUMO

Drug resistance is known to depend on the interactions with cell membranes and other molecules such as human cytochromes P450 (CYPs) which are anchored on the endoplasmic reticulum (ER) membrane and involved in the metabolism of anticancer drugs. In this study, we determined the influence from cytochrome P450 3A4 (CYP3A4) on the interaction between the drug doxorubicin (DOX) and Langmuir monolayers mimicking cell membranes. The lipid composition was varied by changing the relative concentrations of cholesterol (Chol), 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine (DPPE), and L-α-phosphatidylinositol (PI). Three compositions were studied in detail which represented a healthy cell membrane and cancerous cell membranes. DOX induced an expansion in the surface pressure isotherms for all monolayers, with stronger effect for the composition of cancerous cell with a high Chol content, thus confirming the relevance of lipid composition. This effect decreased considerably when CYP3A4 was incorporated with the formation of CYP3A4-DOX complexes, according to results from polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS) measurements. Taken together, these results support the hypothesis of CYP3A4 being involved in drug resistance, which may be exploited to design strategies to enhance chemotherapy efficacy.


Assuntos
Citocromo P-450 CYP3A , Lipídeos de Membrana , Humanos , Lipídeos de Membrana/química , Doxorrubicina/farmacologia , Fosfatidiletanolaminas/química , Colesterol/química
4.
Biomed Pharmacother ; 145: 112426, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34861633

RESUMO

Glutathione-s-transferase is believed to be involved in the resistance to chemotherapeutic drugs, which depends on the interaction with the cell membranes. In this study, we employed Langmuir monolayers of a mixture of phospholipids and cholesterol (MIX) as models for tumor cell membranes and investigated their interaction with the anticancer drugs cisplatin (CDDP) and doxorubicin (DOX). We found that both DOX and CDDP expand and affect the elasticity of MIX monolayers, but these effects are hindered when glutathione-s-transferase (GST) and its cofactor glutathione (GSH) are incorporated. Changes are induced by DOX or CDDP on the polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS) data for MIX/GST/GSH monolayers, thus denoting some degree of interaction that is not sufficient to alter the monolayer mechanical properties. Overall, the results presented here give support to the hypothesis of the inactivation of DOX and CDDP by GST and point to possible directions to detect and fight drug resistance.


Assuntos
Antineoplásicos/farmacologia , Cisplatino/farmacologia , Doxorrubicina/farmacologia , Glutationa Transferase/metabolismo , Membrana Celular/metabolismo , Colesterol/metabolismo , Resistencia a Medicamentos Antineoplásicos/fisiologia , Modelos Biológicos , Fosfolipídeos/metabolismo
5.
Colloids Surf B Biointerfaces ; 196: 111357, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32992284

RESUMO

The fight against drug resistance in chemotherapy requires a molecular-level understanding of the drug interaction with cell membranes, which today is feasible with membrane models. In this study, we report on the interaction of gemcitabine (GEM), a pyrimidine nucleoside antimetabolite used to treat pancreatic cancer, with Langmuir films that mimic healthy and cancerous cell membranes. The cell membrane models were made with eight compositions of a quaternary mixture containing 1,2-dipalmitoyl-sn-glycerol-3-phosphocholine (DPPC), 1,2-dipalmitoyl-sn-glycero-3-phosphoserine (DPPS), sphingomyelin (SM), and cholesterol (CHOL). The relative concentration of SM was increased so that four of these compositions represented cancerous cells. GEM was found to increase the mean molecular area, also increasing their surface elasticity, with stronger interactions being observed for membranes corresponding to cancerous cells. More specifically, GEM penetrated deepest in the membrane with the highest SM concentration (40 mol%), as inferred from polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). This finding was confirmed with molecular dynamics simulations that also indicated how GEM approaches the membrane, which could be useful for guiding the design of drug delivery systems. The experimental and simulation results are consistent with the preferential attachment of GEM onto cancerous cells and highlight the role of SM on drug-cell interactions.


Assuntos
Antineoplásicos , Esfingomielinas , Membrana Celular , Desoxicitidina/análogos & derivados , Glicerol/análogos & derivados , Fosforilcolina/análogos & derivados , Gencitabina
6.
Mikrochim Acta ; 187(7): 417, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32613349

RESUMO

Electrochemical immunosensors have been developed to determine the carbohydrate antigen 19-9 (CA19-9). They are based on screen-printed carbon electrodes (SPCEs) coated with layer-by-layer (LbL) films of carbon black (CB) and polyelectrolytes. Owing to a suitable choice of LbL film architecture, the procedures for immobilization of anti-CA19-9 antibodies on the electrode surfaces were straightforward. Mechanically flexible immunosensors were capable of detecting CA19-9 within a dynamic range of 0.01 to 40 U mL-1 and a limit of detection of 0.07 U mL-1 using differential pulse voltammetry. In addition to detecting CA19-9 at clinically relevant concentrations for pancreatic cancer in standard solutions, the immunosensors provide the determination of CA19-9 on cell lysate and human serum samples. Using LbL films led to immunosensors with superior performance compared to similar systems obtained by drop casting. The fabrication of this relatively simple, inexpensive platform is a demonstration that SPCEs modified with cost-effective materials are able to detect cancer biomarkers and may be adapted to other disposable immunosensors. Graphical abstract Schematic representation of assembly and characterization of electrochemical immunosensors for the determination of carbohydrate antigen 19-9 based on printed electrodes modified with composites of carbon black and polyelectrolyte films.


Assuntos
Antígenos Glicosídicos Associados a Tumores/sangue , Biomarcadores Tumorais/sangue , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Polieletrólitos/química , Fuligem/química , Anticorpos Imobilizados/imunologia , Antígenos Glicosídicos Associados a Tumores/imunologia , Biomarcadores Tumorais/imunologia , Técnicas Eletroquímicas/instrumentação , Eletrodos , Humanos , Limite de Detecção
7.
Beilstein J Nanotechnol ; 10: 2171-2181, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31807403

RESUMO

Diagnosis of cancer using electroanalytical methods can be achieved at low cost and in rapid assays, but this may require the combination with data treatment for determining biomarkers in real samples. In this paper, we report an immunomagnetic nanoparticle-based microfluidic sensor (INµ-SPCE) for the amperometric detection of the prostate-specific antigen (PSA) biomarker, the data of which were treated with information visualization methods. The INµ-SPCE consists of eight working electrodes, reference and counter electrodes. On the working electrodes, magnetic nanoparticles with secondary antibodies with the enzyme horseradish peroxidase were immobilized for the indirect detection of PSA in a sandwich-type procedure. Under optimal conditions, the immunosensor could operate within a wide range from 12.5 to 1111 fg·L-1, with a low detection limit of 0.062 fg·L-1. Multidimensional projections combined with feature selection allowed for the distinction of cell lysates with different levels of PSA, in agreement with results from the traditional enzyme-linked immunosorbent assay. The approaches for immunoassays and data processing are generic, and therefore the strategies described here may provide a simple platform for clinical diagnosis of cancers and other types of diseases.

8.
Talanta ; 205: 120110, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31450419

RESUMO

Tristeza is a disease that affects citrus crops in general, caused by the Citrus tristeza virus (CTV). It is considered an economically important virus diseases in citrus, which is present in the main citrus producing regions all around the world. Early detection of CTV is crucial to avoid any epidemics and substantial economic losses for the citrus growers. Consequently, the development of rapid, accurate, and sensitive methods capable of detecting the virus in the early stages of the disease is highly desired. Based on that, a low-cost and rapid magneto-immunoassay methodology to detect the capsid protein from CTV (CP-CTV) was proposed. For this, magnetic beads were decorated with antibodies anti-CP-CTV and horseradish peroxidase enzyme (HRP) and applied for the capture and separation of CP-CTV from the sample solutions. The magnetically captured biomarker was detected using a simple disposable microfluidic electrochemical device (DµFED) constructed by rapid prototyping technique and composed by an array of immunosensors. In DµFED, the electrodes were modified with monoclonal antibody anti-CP-CTV and the detection was carried out using amperometry, based on the hydroquinone/H2O2 catalytic redox reaction due to the presence of HRP label in an immune-sandwich structure. The proposed immunoassay presented excellent linearity with a wide linear range of concentration of 1.95-10.0 × 103 fg mL-1 and ultralow detection limit of 0.3 fg mL-1. The disposable device was successfully applied for the detection of Citrus tristeza virus in healthy and infected plant samples, where it showed good agreements with the comparative method of enzyme-linked immunosorbent assay (ELISA). The developed immunoassay methodology showed a sensitive and selective way in the detection of CTV. Hence, it can be considered as a promising analytical alternative for rapid and low-cost diagnosis of Tristeza disease in citrus.


Assuntos
Closterovirus/isolamento & purificação , Dispositivos Lab-On-A-Chip , Animais , Anticorpos Imobilizados/imunologia , Anticorpos Monoclonais Murinos/imunologia , Proteínas do Capsídeo/análise , Proteínas do Capsídeo/imunologia , Citrus/virologia , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Ouro/química , Imunoensaio/métodos , Separação Imunomagnética/métodos , Limite de Detecção , Nanopartículas Metálicas/química , Camundongos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Doenças das Plantas/virologia , Folhas de Planta/virologia , Reprodutibilidade dos Testes
9.
Anal Chim Acta ; 1071: 59-69, 2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31128756

RESUMO

Early diagnosis of cancer by biomarker detection has been widely studied since it can lead to an increase in patient survival rates. Magnetic nanoparticles (MNPs) play an important role in this field acting as a valuable tool in the biomarker immunocapture and detection. In this work, Co0.25Zn0.75Fe2O4 (CoZnFeONPs) nanoparticles were synthesized and applied as enzyme mimics of peroxidase-like catalysis in a disposable enzyme-free microfluidic immunoarray device (µID). The catalytic activity of CoZnFeONPs was evaluated by hydrogen peroxide detection using cyclic voltammetry and the apparent Michaelis-Menten constant was estimated by Lineweaver-Burk equation showing good Km values. In µID, the immunosensors were assembled with monoclonal antibody against CYFRA 21-1 covalently immobilized on graphene oxide previously deposited on the screen-printed carbon-based electrodes. Under optimized conditions, the method presented a good linear response for CYFRA 21-1 in the range of 3.9-1000 fg mL-1 achieving an ultralow limit of detection (LOD) of 0.19 fg mL-1. For comparison, Fe3O4 nanoparticles (FeONPs) was also synthetized and presented results slight inferior to that obtained with CoZnFeONPs. The methods developed using both MNPs exhibited countless advantages when compared with the immunosensors developed for CYFRA-21-1, previously reported in the literature. The methods were successful applied for the detection of CYFRA 21-1 in real serum samples of healthy and prostate cancer patients and showed good correlation with results obtained with the enzyme-linked immunosorbent assay (ELISA). The CoZnFeONPs associated with the disposable microfluidic immunoarray device provides a simple and effective method for biomarker detection that could satisfy the need for a low-cost and rapid test for early diagnosis of cancer.


Assuntos
Antígenos de Neoplasias/sangue , Biomarcadores Tumorais/sangue , Queratina-19/sangue , Dispositivos Lab-On-A-Chip , Nanopartículas Metálicas/química , Técnicas Analíticas Microfluídicas/métodos , Anticorpos/imunologia , Antígenos de Neoplasias/imunologia , Biomarcadores Tumorais/imunologia , Cobalto/química , Eletrodos , Grafite/química , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Ferro/química , Queratina-19/imunologia , Limite de Detecção , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Neoplasias da Próstata/sangue , Reprodutibilidade dos Testes , Zinco/química
10.
Mater Sci Eng C Mater Biol Appl ; 99: 1502-1508, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30889686

RESUMO

Nanostructured capacitive biosensors, combined with inexpensive fabrication technologies, may provide simple, sensitive devices for detecting clinically relevant cancer biomarkers. Herein, we report a novel platform for detecting the pancreatic cancer biomarker CA19-9 using low-cost screen-printed interdigitated electrodes (SPIDEs). The SPIDEs were modified by carbon nano-onions (CNOs) and graphene oxide (GO) films, on which a layer of anti-CA19-9 antibodies was immobilized. The modification with CNOs and GO significantly improved the analytical performance of the biosensor, which displayed superior results to those prepared only with GO. The biossensor exhibited high reproducibility and a relatively low limit of detection of 0.12 U mL-1. Using these devices in combination with information visualization methods we were able to detect CA19-9 in whole cell lysates of colorectal adenocarcinoma. The fabrication of these low-cost, disposable immunosensors is a successful attempt to explore CNOs in capacitive biosensors, which may be extended for detection of different cancer biomarkers.


Assuntos
Biomarcadores Tumorais/análise , Antígeno CA-19-9/análise , Carbono/química , Nanoestruturas/química , Anticorpos/metabolismo , Capacitância Elétrica , Eletrodos , Grafite/química , Humanos , Nanoestruturas/ultraestrutura , Impressão
11.
Talanta ; 194: 611-618, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30609580

RESUMO

Outbreaks of foodborne diseases demand simple, rapid techniques for detecting pathogenic bacteria beyond the standard methods that are not applicable to routine analysis in the food industry and in the points of food consumption. In this work, we developed a sensitive, rapid and low-cost assay for detecting Escherichia coli (E. coli), Staphylococcus aureus (S. aureus) and Salmonella typhimurium (S. typhi) in potable water and apple juice. The assay is based on electrical impedance spectroscopy measurements with screen-printed interdigitated electrodes coupled with magnetite nanoparticles functionalized with the antimicrobial peptide melittin (MLT). The data were analyzed with the information visualization methods Sammon's Mapping and Interactive Document Map to distinguish samples at two levels of contamination from food suitable for consumption. With this approach it has been possible to detect E. coli concentration down to 1 CFU mL-1 in potable water and 3.5 CFU mL-1 in apple juice without sample preparation, within only 25 min. This approach may serve as a low-cost, quick screening procedure to detect bacteria-related food poisoning, especially if the impedance data of several sensing units are combined.


Assuntos
Peptídeos Catiônicos Antimicrobianos/química , Bactérias/isolamento & purificação , Técnicas Biossensoriais/métodos , Microbiologia de Alimentos , Nanopartículas de Magnetita/química , Peptídeos Catiônicos Antimicrobianos/farmacologia , Bactérias/efeitos dos fármacos , Técnicas Biossensoriais/economia , Custos e Análise de Custo , Espectroscopia Dielétrica , Capacitância Elétrica , Eletrodos , Fatores de Tempo
12.
ACS Appl Mater Interfaces ; 9(33): 27433-27440, 2017 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-28742317

RESUMO

Breast cancer is the most common cancer in women worldwide. The detection of biomarkers has played a significant role in the early diagnosis and prognosis of breast cancer. Herein, we describe the construction of a disposable microfluidic immunoarray device (DµID) for the rapid and low-cost detection of CA15-3 (carbohydrate antigen 15-3), a protein biomarker for breast cancer. The DµID was constructed using a simple and rapid prototyping technique and was applied to detect CA15-3 in cancer patients. The DµID construction was based on the use of a double-sided adhesive card with a microfluidic channel and a screen-printed array with 8 electrodes. Both the immunoarray and microfluidic channel were designed using an inexpensive home cutter printer and using low-cost materials. The immunoarray was modified using the layer-by-layer technique aiming at immobilizing the primary antibody. For the biomarker detection, magnetic particles (MPs) modified with polyclonal antibodies and peroxidase enzymes were used as a strategy for capture, separation, and preconcentration of the biomarker, in addition to amplification of the electroanalytical signal. The preconcentration and amplification strategies integrated with the nanostructured immunosensors of the DµID meaningfully contributed toward the detection of CA15-3 with a limit of detection (LoD) of 6 µU mL-1, requiring as low as 2 µL of serum samples for 8 simultaneous detections. The obtained LoD was 1200 times lower compared to those of other immunosensors previously reported in the literature. The DµID was applied for the detection of CA15-3 in real samples of breast cancer patients and was found to present an excellent correlation with the well-established commercial electrochemiluminescence immunoassay. The association of the DµID with nanostructured surfaces and analyte capturing with bioconjugated paramagnetic particles is essentially a promising breakthrough for the low-cost and accurate detection of cancer biomarkers.


Assuntos
Microfluídica , Biomarcadores Tumorais , Técnicas Biossensoriais , Humanos , Imunoensaio , Dispositivos Lab-On-A-Chip , Limite de Detecção
13.
Biosens Bioelectron ; 58: 232-6, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24657642

RESUMO

With the fast growth of cancer research, new analytical methods are needed to measure anticancer drugs. This is usually accomplished by using sophisticated analytical instruments. Biosensors are attractive candidates for measuring anticancer drugs, but currently few biosensors can achieve this goal. In particular, it is challenging to have a general method to monitor various types of anticancer drugs with different structures. In this work, a biosensor was developed to detect anticancer drugs by modifying carbon paste electrodes with glutathione-s-transferase (GST) enzymes. GST is widely studied in the metabolism of xenobiotics and is a major contributing factor in resistance to anticancer drugs. The measurement of anticancer drugs is based on competition between 1-chloro-2,4-dinitrobenzene (CDNB) and the drugs for the GST enzyme in the electrochemical potential at 0.1V vs. Ag/AgCl by square wave voltammetry (SWV) or using a colorimetric method. The sensor shows a detection limit of 8.8µM cisplatin and exhibits relatively long life time in daily measurements.


Assuntos
Antineoplásicos/análise , Técnicas Biossensoriais/instrumentação , Colorimetria/instrumentação , Condutometria/instrumentação , Avaliação Pré-Clínica de Medicamentos/instrumentação , Glutationa Transferase/química , Antineoplásicos/química , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento
14.
J Colloid Interface Sci ; 411: 92-7, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24050641

RESUMO

In a typical protocol for attaching DNA to a gold electrode, thiolated DNA is incubated with the electrode at neutral pH overnight. Here we report fast adsorption of non-thiolated DNA oligomers on gold electrodes at acidic pH (i.e., pH ~3.0). The peak-to-peak potential difference and the redox peak currents in typical cyclic voltammetry of [Fe(CN)6](3-) are investigated to monitor the attachment. Compared with incubation at neutral pH, the lower pH can significantly promote the adsorption processes, enabling efficient adsorption even in 30 min. The adsorption rate is DNA concentration-dependent, while the ionic strength shows no influence. Moreover, the adsorption is base-discriminative, with a preferred order of A>C>>G, T, which is attributed to the protonation of A and C at low pH and their higher binding affinity to gold surface. The immobilized DNA is functional and can hybridize with its complementary DNA but not a random DNA. This work is promising to provide a useful time-saving strategy for DNA assembly on gold electrodes, allowing fast fabrication of DNA-based biosensors and devices.


Assuntos
DNA/química , Ouro/química , Concentração de Íons de Hidrogênio , Compostos de Sulfidrila/química , Adsorção , Hibridização de Ácido Nucleico , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...