1.
Med Biol Eng Comput ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38609577

RESUMO

ASTRACT: One of the most common oral diseases affecting millions of people worldwide is periodontitis. Usually, proteins in body fluids are used as biomarkers of diseases. This study focused on hydrogen peroxide, lipopolysaccharide (LPS), and lactic acid as salivary non-protein biomarkers for oxidative stress conditions of periodontitis. Electrochemical analysis of artificial saliva was done using Gamry with increasing hydrogen peroxide, bLPS, and lactic acid concentrations. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were conducted. From EIS data, change in capacitance and CV plot area were calculated for each test condition. Hydrogen peroxide groups had a decrease in CV area and an increase in percentage change in capacitance, lipopolysaccharide groups had a decrease in CV area and a decrease in percentage change in capacitance, and lactic acid groups had an increase of CV area and an increase in percentage change in capacitance with increasing concentrations. These data showed a unique combination of electrochemical properties for the three biomarkers. Scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) employed to observe the change in the electrode surface and elemental composition data present on the sensor surface also showed a unique trend of elemental weight percentages. Machine learning models using hydrogen peroxide, LPS, and lactic acid electrochemical data were applied for the prediction of risk levels of periodontitis. The detection of hydrogen peroxide, LPS, and lactic acid by electrochemical biosensors indicates the potential to use these molecules as electrochemical biomarkers and use the data for ML-driven prediction tool for the periodontitis risk levels.

2.
Heliyon ; 10(1): e23626, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38192807

RESUMO

Statement of problem: One of the main challenges facing dental implant success is peri-implantitis. Recent evidence indicates that titanium (Ti) corrosion products and undetected-residual cement are potential risk factors for peri-implantitis. The literature on the impact of various types of dental cement on Ti corrosion is very limited. Purpose: This study aimed to determine the influence of dental cement on Ti corrosion as a function of cement amount and type. Materials and methods: Thirty commercially pure Ti grade 4 discs (19 × 7mm) were polished to mirror-shine (Ra ≈ 40 nm). Samples were divided into 10 groups (n = 3) as a cement type and amount function. The groups were no-cement as control, TempBond NE (TB3mm, TB5mm, and TB8mm), FujiCEM-II (FC3mm, FC5mm, and FC8mm), and Panavia-F-2.0 (PC3mm, PC5mm, and PC8mm). Tafel's method estimated corrosion rate (icorr) and corresponding potential (Ecorr) from potentiodynamic curves. Electrochemical Impedance Spectroscopy (EIS) data was utilized to obtain Nyquist and Bode plots. An equivalent electrical circuit estimated polarization resistance (Rp) and double-layer capacitance (Cdl). Inductively coupled plasma mass spectrometry (ICP-MS) analysis was conducted to analyze the electrolyte solution after corrosion. pH measurements of the electrolyte were recorded before and after corrosion tests. Finally, the corroded surface was characterized by a 3D white-light microscope and scanning electron microscope. Statistical analysis was conducted using either one-way ANOVA followed by Tukey's Post Hoc test or Kruskal-Wallis followed by Dunn's test based on data distribution. Results: Based on cement amount, FC and PC significantly increased icorr in higher amounts (FC8mm-icorr = 8.22 × 10-8A/cm2, PC8mm-icorr = 5.61 × 10-8A/cm2) compared to control (3.35 × 10-8A/cm2). In contrast, TB3mm decreased icorr significantly compared to the control. As a function of cement type, FC increased icorr the most. EIS data agrees with these observations. Finally, corroded surfaces had higher surface roughness (Ra) compared to non-corroded surfaces. Conclusion: The study indicated that cement types FC and PC led to increased Ti-corrosion as a function of a higher amount. Hence, the implant stability could be impacted by the selection, excessive cement, and a potentially increased risk of peri-implantitis.

3.
Int J Biol Macromol ; 257(Pt 2): 128773, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38096932

RESUMO

Periodontitis is a chronic inflammation of the periodontium caused by a persistent bacterial infection, resulting in destruction of the supporting structures of teeth. Analysis of microbial composition in saliva can inform periodontal status. Actinobacillus actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), and Streptococcus mutans (Sm) are among reported periodontal pathogens, and were used as model systems in this study. Our atomic force microscopic (AFM) study revealed that these pathogens are biological nanorods with dimensions of 0.6-1.1 µm in length and 500-700 nm in width. Current bacterial detection methods often involve complex preparation steps and require labeled reporting motifs. Employing surface-enhanced Raman spectroscopy (SERS), we revealed cell-type specific Raman signatures of these pathogens for label-free detection. It overcame the complexity associated with spectral overlaps among different bacterial species, relying on high signal-to-noise ratio (SNR) spectra carefully collected from pure species samples. To enable simple, rapid, and multiplexed detection, we harnessed advanced machine learning techniques to establish predictive models based on a large set of raw spectra of each bacterial species and their mixtures. Using these models, given a raw spectrum collected from a bacterial suspension, simultaneous identification of all three species in the test sample was achieved at 95.6 % accuracy. This sensing modality can be applied to multiplex detection of a broader range and a larger set of periodontal pathogens, paving the way for hassle-free detection of oral bacteria in saliva with little to no sample preparation.


Assuntos
Periodontite , Análise Espectral Raman , Humanos , Periodontite/microbiologia , Porphyromonas gingivalis , Periodonto , Saliva
4.
Res Sq ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37886457

RESUMO

Fretting-corrosion is one of the failure processes in many applications, including biomedical implants. For example, the modern design of hip implants with multiple components offers better flexibility and inventory storage. However, it will trigger the fretting at the implant interfaces with a small displacement amplitude (< 5 µm) and usually in a partial slip region. Although many studies have been reported on the fretting, they have high displacement amplitude and are in the gross slip region. It is imperative to have an apparatus to overcome such limitations, specifically for hip implant applications. Therefore, this study describes the development of a fretting-corrosion apparatus with low micro-motion (≤ 5 µm) that can simultaneously monitor the corrosion process. Initial experiments with Ti6Al4V-Ti6Al4V in 0.9% saline, Ti6Al4V-Ti6Al4V in bovine calf serum (BCS), and ZrO2-Ti6Al4V in BCS were conducted to validate the system. As a result, the fretting regime of all groups remained partially slip region throughout the 3600 cycles, and the possible failure mechanisms are proposed in this manuscript.

5.
Int J Biol Macromol ; 253(Pt 4): 126681, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37666403

RESUMO

Breast cancer is the second highest cause of cancer-related mortality in women worldwide and in the United States, accounting for around 571,000 deaths per year. Early detection of breast cancer increases treatment results and the possibility of a cure. While existing diagnostic modalities such as mammography, ultrasound, and biopsy exist, some are prohibitively expensive, uncomfortable, time-consuming, and have limited sensitivity, necessitating the development of a cost-effective, rapid, and highly sensitive approach such as an electrochemical biosensor. Our research focuses on detecting breast cancer patients using the ECM1 biomarker, which has higher expression in synthetic urine. Our study has two primary objectives: (i) Diverse ECM1 protein concentrations are measured using electrochemical impedance spectroscopy and ELISA. Establishing a standard curve for the electrochemical biosensor by calibrating ECM-1 protein levels using electrochemical impedance spectroscopy. (ii) Validation of the effectiveness of the electrochemical biosensor. This aim entails testing the unknown concentration of ECM1 in the synthetic urine to ensure the efficiency of the biosensor to detect the biomarker in the early stages. The results show that the synthetic urine solution's ECM-1 detection range ranges from 1 pg/ml to 500 ng/ml. This shows that by detecting changes in ECM-1 protein levels in patient urine, the electrochemical biosensor can consistently diagnose breast cancer in its early stages or during increasing recurrence. Our findings highlight the electrochemical biosensor's efficacy in detecting early-stage breast cancer biomarkers (ECM-1) in patient urine. Further studies will be conducted with patient samples and develop handheld hardware for patient usage.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Biomarcadores Tumorais/metabolismo , Proteômica , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Proteínas da Matriz Extracelular
6.
Ann Biomed Eng ; 51(12): 2749-2761, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37530907

RESUMO

Titanium-based implants utilized in total joint arthroplasties could restore primary musculoskeletal function to patients suffering from osteoarthritis and other conditions. Implants are susceptible to failure stemming from aseptic loosening and infection at the joint site, eventually requiring revision surgery. We hypothesized that there might be a feedback loop by which metal degradation particles and ions released from the implant decrease cell viability and increase immune response, thereby creating biochemical conditions that increase the corrosion rate and release more metal ions. This study focused on the synergistic process through cell viability assays and electrochemical tests. From the results, inflammatory conditions from ion release resulting in cell death would further increase the corrosion rate at the metal implant site. The synergistic interaction in the implant surroundings in which infectious conditions produce Ti ions that contribute to more infection, creating a potential cycle of accelerating corrosion.


Assuntos
Metais , Titânio , Humanos , Próteses e Implantes , Íons , Corrosão
7.
Biomed Mater Devices ; : 1-18, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37363139

RESUMO

The human body has a unique way of saying when something is wrong with it. The molecules in the body fluids can be helpful in the early detection of diseases by enabling health and preventing disease progression. These biomarkers enabling better healthcare are becoming an extensive area of research interest. Biosensors that detect these biomarkers are becoming the future, especially Point Of Care (POC) biosensors that remove the need to be physically present in the hospital. Detection of complex and systemic diseases using biosensors has a long way to go. Saliva-based biosensors are gaining attention among body fluids due to their non-invasive collection and ability to detect periodontal disease and identify systemic diseases. The possibility of saliva-based diagnostic biosensors has gained much publicity, with companies sending home kits for ancestry prediction. Saliva-based testing for covid 19 has revealed effective clinical use and relevance of the economic collection. Based on universal biomarkers, the detection of systemic diseases is a booming research arena. Lots of research on saliva-based biosensors is available, but it still poses challenges and limitations as POC devices. This review paper talks about the relevance of saliva and its usefulness as a biosensor. Also, it has recommendations that need to be considered to enable it as a possible diagnostic tool.

8.
Bone ; 171: 116746, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36965655

RESUMO

In tissue engineering, the fate of a particular organ/tissue regeneration and repair mainly depends on three pillars - 3D architecture, cells used, and stimulus provided. 3D cell supportive structure development is one of the crucial pillars necessary for defining organ/tissue geometry and shape. In recent years, the advancements in 3D bio-printing (additive manufacturing) made it possible to develop very precise 3D architectures with the help of industrial software like Computer-Aided Design (CAD). The main requirement for the 3D printing process is the bio-ink, which can act as a source for cell support, proliferation, drug (growth factors, stimulators) delivery, and organ/tissue shape. The selection of the bio-ink depends upon the type of 3D tissue of interest. Printing tissues like bone and cartilage is always challenging because it is difficult to find printable biomaterial that can act as bio-ink and mimic the strength of the natural bone and cartilage tissues. This review describes different biomaterials used to develop bio-inks with different processing variables and cell-seeding densities for bone and cartilage 3D printing applications. The review also discusses the advantages, limitations, and cell bio-ink compatibility in each biomaterial section. The emphasis is given to bio-inks reported for 3D printing cartilage and bone and their applications in orthopedics and orthodontists. The critical/important performance and the architectural morphology requirements of desired bone and cartilage bio-inks were compiled in summary.


Assuntos
Tinta , Engenharia Tecidual , Materiais Biocompatíveis , Impressão Tridimensional , Cartilagem , Alicerces Teciduais/química
9.
Adv Colloid Interface Sci ; 314: 102860, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36931199

RESUMO

Polypyrrole (PPy) is one of the most studied conductive polymers due to its electrical conductivity and biological properties, which drive the possibility of numerous applications in the biomedical area. The physical-chemical features of PPy allow the manufacture of biocompatible devices, enhancing cell adhesion and proliferation. Furthermore, owing to the electrostatic interactions between the negatively charged bacterial cell wall and the positive charges in the polymer structure, PPy films can perform an effective antimicrobial activity. PPy is also frequently associated with biocompatible agents and antimicrobial compounds to improve the biological response. Thus, this comprehensive review appraised the available evidence regarding the PPy-based films deposited on metallic implanted devices for biomedical applications. We focus on understanding key concepts that could influence PPy attributes regarding antimicrobial effect and cell behavior under in vitro and in vivo settings. Furthermore, we unravel the several agents incorporated into the PPy film and strategies to improve its functionality. Our findings suggest that incorporating other elements into the PPy films, such as antimicrobial agents, biomolecules, and other biocompatible polymers, may improve the biological responses. Overall, the basic properties of PPy, when combined with other composites, electrostimulation techniques, or surface treatment methods, offer great potential in biocompatibility and/or antimicrobial activities. However, challenges in synthesis standardization and potential limitations such as low adhesion and mechanical strength of the film must be overcome to improve and broaden the application of PPy film in biomedical devices.


Assuntos
Polímeros , Pirróis , Polímeros/farmacologia , Polímeros/química , Pirróis/farmacologia , Pirróis/química , Adesão Celular , Condutividade Elétrica
10.
Med Biol Eng Comput ; 61(6): 1239-1255, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36701013

RESUMO

The digital health industry is experiencing fast-paced research which can provide digital care programs and technologies to enhance the competence of healthcare delivery. Orthopedic literature also confirms the applicability of artificial intelligence (AI) and machine learning (ML) models to medical diagnosis and clinical decision-making. However, implant monitoring after primary surgery often happens with a wellness visit or when a patient complains about it. Neglecting implant design and other technical errors in this scenario, unmonitored circumstances, and lack of post-surgery monitoring may ultimately lead to the implant system's failure and leave us with the only option of high-risk revision surgery. Preventive maintenance seems to be a good choice to identify the onset of an irreversible prosthesis failure. Considering all these aspects for hip implant monitoring, this paper explores existing studies linking ML models and intelligent systems for hip implant diagnosis. This paper explores the feasibility of an alternative continuous monitoring technique for post-surgery implant monitoring backed by an in vitro ML case study. Tribocorrosion and acoustic emission (AE) data are considered based on their efficacy in determining irreversible alteration of implant material to prevent total failures. This study also facilitates the relevance of developing an artificially intelligent implant monitoring methodology that can function with daily patient activities and how it can influence the digital orthopedic diagnosis. AI-based non-invasive hip implant monitoring system enabling point-of-care testing.


Assuntos
Inteligência Artificial , Prótese de Quadril , Humanos , Aprendizado de Máquina , Falha de Prótese
11.
Artigo em Inglês | MEDLINE | ID: mdl-38525435

RESUMO

Tribocorrosion is an integration of two areas-tribology and corrosion. It can be defined as the material degradation caused by the combined effect of corrosion and tribological process at the material interfaces. Significant development has occurred in the field of tribocorrosion over the past years. This development is due to its applications in various fields, such as aerospace, marine, biomedical, and space. Focusing on biomedical applications, tribocorrosion finds its applications in the implants used in cardiovascular, spine, orthopedics, trauma, and dental areas. It was reported that around 7.2 million Americans are living with joint implants. Implant surgery is a traumatic and expensive procedure. Tribocorrosion can affect the lifespan of the implants, thus leading to implant failure and a potential cause of revision surgery. Hence, it is essential to understand how tribocorrosion works, its interaction with the implants, and what procedures can be implemented to protect materials from tribocorrosion. This paper discusses how tribocorrosion research has evolved over the past 11 years (2010-2021). This is a comprehensive overview of tribocorrosion research in biomedical applications.

12.
J Bio Tribocorros ; 8(1)2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35911172

RESUMO

Ti6Al4V is the most common titanium alloy within the biomaterial field. While material standards for different variations of this alloy exist, there are only minimal requirements with respect to its microstructure which is directly related to the alloy's properties. Thus, a better understanding of the Ti6Al4V microstructure of common contemporary implant components and its effect on the electrochemical behavior is needed; including additively manufactured (AM) devices. Therefore, this study aimed at characterizing the microstructures of conventional and AM total joint replacement components, and to identify the effect of microstructure on the electrochemical behavior. Thus, 22 components from conventional (surgically retrieved cast and wrought implants) and AM implants (not previously implanted) were analysed to characterize microstructure by means of electron backscatter diffraction (EBSD) and energy dispersive X-Ray spectroscopy (EDS), and tested to determine its electrochemical behavior (potentiodynamic polarization and EIS). The microstructure of the conventional implants varied broadly but could be categorized into four groups as to their grain size and shape: fine equiaxed, coarse equiaxed, bimodal, and lamellar. The AM components exhibited a fifth category: lath-type. The AM components had a network of ß-phase along the α-phase grain boundaries, prior ß-grains, and manufacturing voids. Finally, the electrochemical study showed that the equiaxed coarse grains and lath-type grains (AM components) had inferior electrochemical behavior, whereas cast alloys had superior electrochemical behaviour; fine-grained wrought alloys likely provide the best compromise between electrochemical and mechanical properties.

13.
J Mech Behav Biomed Mater ; 134: 105402, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36041275

RESUMO

Cobalt-chromium-molybdenum (CoCrMo) alloy is one of the most used metals in total hip replacement (THR) due to the alloy's superior corrosion qualities and biocompatibility. Over time these prostheses may undergo wear and corrosion processes in a synergistic process known as tribocorrosion. Implant retrieval studies have shown that damage patterns on THR modular junction surfaces indicating specifically in vivo fretting-corrosion to take place. To date, there have been no studies on the fretting-corrosion behaviors of CoCrMo alloy under the consideration of specific microstructural features. A custom-built flat-on-flat fretting-corrosion setup was utilized to test the synergistic tribocorrosion behavior of fretting-corrosion. The difference in microstructure was generated through the cutting orientations of the transverse and the longitudinal direction of the bar stock material, where the longitudinal cut exhibits a characteristic banded microstructure (banded group) and the transverse cut a homogenous microstructure (unbanded group). A three-electrode system was employed to monitor the induced currents. Two different types of electrolytes were used in the current study: 1. Bovine calf serum (BCS-30 g/L protein) (normal conditions) 2. BCS with Lipopolysaccharide (LPS, 0.15 µg/ml) (simulated infectious conditions). In the free potential mode, banded samples showed an increased potential compared to the unbanded samples. In potentiostatic conditions, the banded group also exhibited a higher induced current in both electrolyte environments, indicating more corrosion loss. Both Nyquist and Bode plots showed both orientations of metal becoming more corrosion resistant post-fretting when compared to pre-fretting data. The longitudinal group at OCP demonstrated a unique shape of the fretting-loop, which might be related to tribochemical reactions. Based on the mechanical, electrochemical, and surface characterization data, the transverse group (unbanded) microstructures demonstrates a higher resistance to fretting-corrosion damage.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Animais , Bovinos , Corrosão , Teste de Materiais , Metais , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície , Vitálio
14.
J Biomed Mater Res B Appl Biomater ; 110(9): 2146-2156, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35384274

RESUMO

One of the major drawbacks associated with autologous fat grafting is unpredictable graft retention. Various efforts to improve the survivability of these cells have been explored, but these methods are time-consuming, complex, and demand significant technical skill. In our study, we examine the use of cryopreserved amniotic membrane as a source of exogenous growth factors to improve adipocyte survivability under normal and hypoxic conditions. Human primary preadipocytes were cultured in a gelatin-ferulic acid (Gtn-FA) hydrogel with variable oxygen concentration and treated with amniotic membrane-derived condition medium (CM) for 7 days. This hydrogel provides a hypoxic environment and also creates a 3D cell culture to better mimic recipient site conditions. The O2 concentration in the hydrogel was measured by electron paramagnetic resonance oxygen imaging (EPROI). The conjugation of FA was confirmed by FTIR and NMR spectroscopy. The cell viability and adipocyte differentiation were analyzed by alamarBlue™ assay, Oil Red O staining, and RT-qPCR. The expression of genes: Pref-1, C/EBP ß, C/EBP α, PPAR-Æ´, SLC2A4, and VEGF-A were quantified. The cell viability results show that the 50% CM showed significantly higher cell pre-adipocyte cell viability. In addition, compared to normal conditions, hypoxia/CM provided higher PPAR-Æ´ (p < .05), SLC2A4, and VEGF-A (p < .05) (early and terminal differentiating markers) mRNA expression. This finding demonstrates the efficacy of amniotic CM supplementation as a novel way to promote adipocyte survival and retention via the expression of key gene markers for differentiation and angiogenesis.


Assuntos
Âmnio , Fator A de Crescimento do Endotélio Vascular , Adipócitos , Diferenciação Celular , Sobrevivência Celular , Humanos , Hidrogéis/metabolismo , Hipóxia/metabolismo , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Oxigênio/metabolismo , Oxigênio/farmacologia , Receptores Ativados por Proliferador de Peroxissomo/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
15.
Med Biol Eng Comput ; 60(5): 1497-1510, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35314956

RESUMO

Any mechanical instability associated with total hip replacement (THR) excites elastic waves with different frequencies and propagates through the surrounding biological layers. Using the acoustic emission (AE) technique as a THR monitoring tool provides valuable information on structural degradations associated with these implants. However, several factors can compromise the reliability of the signals detected by AE sensors, such as attenuation of the detected signal due to the presence of biological layers in the human body between prosthesis (THR) and AE sensor. The main objective of this study is to develop a numerical model of THR that evaluates the impact of biological layer thicknesses on AE signal propagation. Adipose tissue thickness, which varies the most between patients, was modeled at two different thicknesses 40 mm and 70 mm, while the muscle and skin thicknesses were kept to a constant value. The proposed models were tested at different micromotions of 2 µm, 15-20 µm at modular junctions, and different frequencies of 10-60 kHz. Attenuation of signal is observed to be more with an increase in the selected boundary conditions along with an increase in distance the signals propagate through. Thereby, the numerical observations drawn on each interface helped to simulate the effect of tissue thicknesses and their impact on the attenuation of elastic wave propagation to the AE receiver sensor.


Assuntos
Artroplastia de Quadril , Acústica , Artroplastia de Quadril/métodos , Humanos , Próteses e Implantes , Reprodutibilidade dos Testes
16.
J Oral Maxillofac Surg ; 80(5): 798-813, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35157828

RESUMO

PURPOSE: Metallic temporomandibular joint replacement (TMJR) systems vary depending on design, material composition, and manufacturing methods such as casting, forging, and additive manufacturing. Therefore, the purpose of this study was to measure the association between manufacturing process of TMJR systems in terms of microstructure and electrochemical properties. MATERIALS AND METHODS: The sample was composed of new or surgically retrieved TMJ replacement devices of either titanium alloy (Ti6Al4V) or cobalt-chromium-molybdenum (CoCrMo) alloy from 8 different manufacturers. The primary predictor variable was alloy type, according to its manufacturing process (wrought, cast, additively manufactured [AM]). The primary outcome variables were 1) microstructure (grain size, aspect ratio, and phase content) and 2) corrosion potential and current, polarization resistance, and capacitance. Differences between alloy groups were determined by t tests, Kruskal-Wallis, and Mann-Whitney tests. RESULTS: We demonstrated that the TMJR CoCrMo and Ti6Al4V alloy microstructures can vary broadly within American Society for Testing and Materials specifications, where the components made of Ti6Al4V had 3 types of microstructures (equiaxial, bimodal, and martensitic) out of 10 samples, and the components made of CoCrMo had 2 types of microstructure (equiaxial and dendritic) out of 16 samples. Some CoCrMo alloys exhibited preferential corrosion sites, while wrought Ti6Al4V alloys trended toward a superior corrosion behavior (corrosion rate: 2 × 10-9 A/cm2, polarization resistance: 5,000,000 kΩcm2, and capacitance: 10 µSsa/cm2) compared with AM alloys (39 × 10-9 A/cm2, 1676 kΩcm2, 36 µSsa/cm2, respectively), where 4 samples of each group were tested and repeated 5 times. Among four AM devices, two exhibited a significantly inferior corrosion behavior. CONCLUSIONS: Although AM is an exciting emerging new technology that allows manufacturing of custom-made TMJR, their corrosion behavior is still inferior in comparison to that of traditional wrought alloys. Preventing corrosion is crucial because it can cause surface defects that may lead to implant fracture.


Assuntos
Ligas , Prótese Articular , Ligas/química , Animais , Corrosão , Humanos , Teste de Materiais , Camundongos , Propriedades de Superfície , Articulação Temporomandibular/cirurgia
17.
J Bio Tribocorros ; 8(2)2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37736215

RESUMO

The frequency of surgeries involving the use of metal implants in orthopedic medicine to replace degenerative or fractured joints is increasing, and it is therefore important to optimize the lifespan and quality of these implants. Advances in additive manufacturing (AM), or 3D printing, are creating new opportunities to personalize implants in ways that reduce mechanical stress at the joint implant interface and improve bone ingrowth and implant stability; however, it is not well understood if and to what degree the AM process alters the corrosion behavior of the materials it produces. In this study, six Ti6Al4V prints manufactured via a selective laser melting (SLM) method were examined regarding their corrosion behavior in both saline and bovine calf serum (BCS) solutions. Ecorr and Icorr values were comparable between the CM-Ti6Al4V control and SLM-EDM surfaces; however, SLM surfaces were found to have more narrow passivation behavior evidenced by significant decreases in Epass values relative to CM-Ti6Al4V. We believe this is a consequence of microstructural differences between CM-Ti6Al4V and SLM-Ti6Al4V. Specifically, the SLM-Ti6Al4V demonstrated a dominant α' martensitic microstructure and decreased vanadium-rich ß-phase. BCS solution had a detrimental effect on potential parameters, Ecorr and OCP, decreasing these values relative to their saline counterparts. Increased surface roughness of the SLM-printed surface seemed to amplify the effects of the BCS solution. Furthermore, modest decreases in Epass and Ipass were observed in BCS solution, suggesting that the presence of protein may also interfere with passivation behavior. These findings have implications for how SLM-Ti6Al4V implants will perform in vivo and could possibly influence implant longevity and performance.

18.
Biotechnol Bioeng ; 118(12): 4829-4839, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34596239

RESUMO

The generation of degradation products (DPs) like ions and organo-metallic particles from corroding metallic implants is an important healthcare concern. These DPs generate local and systemic toxicity. The impact on local toxicity is well documented, however, little is known about systemic toxicity. This is mainly due to the limited scope of the current microtiter plate-based (static) toxicity assay techniques. These methods do not mimic the systemic (dynamic) conditions. In this study, it is hypothesized that DPs incubated with cells in static conditions might provide improper systemic toxicity results, as there is no movement mimicking the blood circulation around cells. This study reports the development of a three-chambered prototype microfluidic system connected to the operational hip implant simulator to test the cellular response induced by the DPs. This setup is called a dynamic microfluidic bioreactor-hip simulator system. We hypothesize that a dynamic microfluidic system will provide a realistic toxicology response induced by DPs than a static cell culture plate. To prove the hypothesis, Neuro2a (N2a) cells were used as representative cells to study systemic neurotoxicity by the implant DPs. The microfluidic bioreactor system was validated by comparing the cell toxicity against the traditional static system and using COMSOL modeling for media flow with DPs. The hip implant simulator used in this study was a state-of-the-art sliding hip simulator developed in our lab. The results suggested that static toxicity was significantly more compared to dynamic microfluidic-based toxicity. The newly developed DMBH system tested for in situ systemic toxicity on N2a cells and demonstrated very minimum toxicity level (5.23%) compared to static systems (31.16%). Thus, the new DMBH system is an efficient tool for in situ implant metal systemic toxicity testing.


Assuntos
Reatores Biológicos , Metais/toxicidade , Técnicas Analíticas Microfluídicas/instrumentação , Modelos Biológicos , Testes de Toxicidade , Animais , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Desenho de Equipamento , Prótese de Quadril , Camundongos , Testes de Toxicidade/instrumentação , Testes de Toxicidade/métodos
19.
Materials (Basel) ; 14(19)2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34640130

RESUMO

The corrosive titanium products in peri-implant tissues are a potential risk factor for peri-implantitis. There is very limited information available on the effect of the corrosion and wear products on the dental implant corrosion. Therefore, we determined the influence of Ti-ions and Ti-particles on Ti corrosion. Eighteen commercially pure-Ti-grade-2 discs were polished to mirror-shine. Samples were divided into six groups (n = 3) as a function of electrolytes; (A) Artificial saliva (AS), (B) AS with Ti-ions (the electrolyte from group A, after corrosion), (C) AS with Ti-particles 10 ppm (D) AS with Ti-particles 20 ppm, (E) AS with Ti-ions 10 ppm, and (F) AS with Ti-ions 20 ppm. Using Tafel's method, corrosion potential (Ecorr) and current density (Icorr) were estimated from potentiodynamic curves. Electrochemical Impedance Spectroscopy (EIS) data were used to construct Nyquist and Bode plots, and an equivalent electrical circuit was used to assess the corrosion kinetics. The corroded surfaces were examined through a 3D-white-light microscope and scanning electronic microscopy. The data demonstrated that the concentration of Ti-ions and corrosion rate (Icorr) are strongly correlated (r = 0.997, p = 0.046). This study indicated that high Ti-ion concentration potentially aggravates corrosion. Under such a severe corrosion environment, there is a potential risk of increased implant associated adverse tissue reactions.

20.
Am J Dent ; 34(4): 191-194, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34370910

RESUMO

PURPOSE: To evaluate the in vitro protective effect of a mint formulation containing (-)-epigallocatechin-3-gallate (EGCg-mint) on root dentin exposed to a highly erosive environment in the presence and absence of proteolytic challenge. METHODS: Root dentin specimens were subjected to an erosion-remineralization cycling model (6×/day; 5 days) that included 5-minute immersion in 1% citric acid and 60-minute immersion in remineralization solution (RS). At the remineralization half-time, the specimens were treated (n= 20) with EGCg-mint, RS (negative control) or sodium fluoride (1,000 ppm of NaF; positive control). Half of the specimens were kept overnight in RS (pH cycling) and the other half in RS with Clostridium histolyticum collagenase (pH-proteolytic cycling). Erosion depth was measured using optical profilometry and data analyzed by two-way ANOVA and Tukey tests (α= 0.05). RESULTS: Under pH-cycling, NaF resulted in statistically lower erosion depth compared to EGCg-mint (P= 0.020) and RS (P= 0.005). Under pH-proteolytic cycling, EGCg-mint and NaF significantly decreased the tissue loss (erosion depth, P< 0.001) compared to the RS. The EGCg-mint exhibited an anti-erosion property on root dentin under a proteolytic challenge. NaF presented an anti-erosion property regardless of the erosive cycling model. CLINICAL SIGNIFICANCE: The anti-erosive action of an over-the-counter mint, containing active ingredients, including epigallocatechin-3-gallate, is likely by the protective mechanisms of the dentin extracellular matrix.


Assuntos
Mentha , Erosão Dentária , Ácido Cítrico , Dentina , Fluoretos , Humanos , Fluoreto de Sódio/farmacologia , Erosão Dentária/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...