Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610957

RESUMO

PURPOSE: Evaluation of the influence of intrinsic and extrinsic conditions on ablation zone volumes (AZV) after microwave ablation (MWA). METHODS: Retrospective analysis of 38 MWAs of therapy-naïve liver tumours performed with the NeuWave PR probe. Ablations were performed either in the 'standard mode' (65 W, 10 min) or in the 'surgical mode' (95 W, 1 min, then 65 W, 10 min). AZV measurements were obtained from contrast-enhanced computed tomography immediately post-ablation. RESULTS: AZVs in the 'standard mode' were smaller than predicted by the manufacturer (length 3.6 ± 0.6 cm, 23% below 4.7 cm; width 2.7 ± 0.6, 23% below 3.5 cm). Ablation zone past the tip was limited to 6 mm in 28/32 ablations. Differences in AZV between the 'surgical mode' and 'standard mode' were not significant (15.6 ± 7.8 mL vs. 13.9 ± 8.8 mL, p = 0.6). AZVs were significantly larger in case of hepatocellular carcinomas (HCCs) (n = 19) compared to metastasis (n = 19; 17.8 ± 9.9 mL vs. 10.1 ± 5.1 mL, p = 0.01) and in non-perivascular tumour location (n = 14) compared to perivascular location (n = 24, 18.7 ± 10.4 mL vs. 11.7 ± 6.1 mL, p = 0.012), with both factors remaining significant in two-way analysis of variance (HCC vs. metastasis: p = 0.02; perivascular vs. non-perivascular tumour location: p = 0.044). CONCLUSION: Larger AZVs can be expected in cases of HCCs compared with metastases and in non-perivascular locations. Using the 'surgical mode' does not increase AZV significantly.

2.
Abdom Radiol (NY) ; 47(1): 431-442, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34642785

RESUMO

PURPOSE: To investigate whether the iodized oil (Lipiodol, Guerbet Group, Villepinte, France) retention pattern influences the treatment efficacy of combined transarterial Lipiodol injection (TLI) and thermal ablation in patients with hepatocellular carcinoma (HCC). METHODS: Data of 198 patients (280 HCC lesions), who underwent TLI plus computed tomography (CT)-guided thermal ablation at three separate medical institutions between June 2014 and September 2020, were reviewed and analyzed. The Lipiodol retention pattern was classified as complete or incomplete based on non-enhanced CT at the time of ablation. The primary outcome was local recurrence-free survival (LRFS) for lesions; the secondary outcome was overall survival (OS) for patients. Propensity score matching (PSM) was performed using a caliper width of 0.1 between the two groups. Differences in LRFS and OS between the two groups were compared using the log-rank test. RESULTS: A total of 133 lesions exhibited a complete Lipiodol retention pattern, while 147 exhibited an incomplete pattern. After PSM analysis of baseline characteristics of the lesions, 121 pairs of lesions were matched. LRFS was significantly longer for lesions exhibiting complete retention than for those exhibiting incomplete retention (P = 0.030). After PSM analysis of patient baseline characteristics, 74 pairs of patients were matched. There was no significant difference in OS between the two groups (P = 0.456). CONCLUSION: Lipiodol retention patterns may influence the treatment efficacy of combined TLI and thermal ablation for HCC lesions. However, a survival benefit for the Lipiodol retention pattern among HCC patients was not observed and needs further confirmation.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Quimioembolização Terapêutica/métodos , Óleo Etiodado , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
3.
Eur J Radiol ; 143: 109944, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34482176

RESUMO

PURPOSE: Due to the difficult differentiation from non-specific postoperative soft tissue formation (PSF), early diagnosis of pancreatic carcinoma recurrence remains challenging. Thus, we investigated the diagnostic potential of dual-energy (DE) contrast-enhanced CT. METHOD: After potentially curative pancreatic carcinoma resection, 31 consecutive patients with PSF were examined via DE perfusion CT, acquiring 34 images (80 kVp/140 kVp) every 1.5 s, as the initial purpose of this study was evaluating CT-Perfusion. Corresponding time points of arterial, pancreatic, and early venous phase were calculated from bolus trigger times in prior conventional CT. Iodine and 120 kVp-equivalent images were calculated. Regions of interest were placed in each soft tissue formation. Diagnosis of local recurrence was confirmed by regular follow-up or histopathology. RESULTS: Final diagnosis was local recurrence in 17 patients and non-specific PSF in 14 patients. Iodine concentrations in early venous phase were significantly higher in recurrent carcinoma than in non-specific PSF (1.47 mg/ml vs. 0.96 mg/ml, p = 0.007). In earlier contrast phases iodine concentrations tended to be higher, but not significantly. CT numbers in recurrent carcinoma in 120 kVp-equivalent images in venous phase were significantly higher, too (74HU vs 47HU, p = 0.002). ROC-curve analysis for iodine concentrations in early venous phase suggests a cut-off value of ≥ 1.55 mg/ml for local recurrence (AUC = 0.78, specificity = 1.0, sensitivity = 0.53) and for CT numbers in 120kVp-equivalent images a cut-off value of ≥ 57HU (AUC = 0.82, specificity = 0.82, sensitivity = 0.71). CONCLUSION: In difficult cases, measuring iodine concentrations or CT numbers in PSF in (early) venous phase DECT could be a valuable additional parameter for differentiating local recurrence from non-specific PSF.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Meios de Contraste , Diagnóstico Precoce , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Pancreáticas , Tomografia Computadorizada por Raios X , Neoplasias Pancreáticas
4.
Sci Rep ; 10(1): 21902, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33318515

RESUMO

Irreversible electroporation (IRE) is an ablation procedure in which cell death is induced by ultrashort electrical pulses. In this unicentric retrospective study we investigated the influence of needle positioning on ablation success. 15 IREs with residual tumor after ablation, detected in the first follow-up MRI, were included, and compared with 30 successful ablations. Evaluation of needle geometry revealed significantly higher values for needle divergence (NDiv, 7.0° vs. 3.7°, p = 0.02), tumor-center-to-ablation-center distance (TACD, 11.6 vs. 3.2 mm, p < 0.001), tumor-to-needle distance (4.7 vs. 1.9 mm, p = 0.04), and tumor diameter per needle (7.5 vs. 5.9 mm/needle, p = 0.01) in patients with residual tumor. The average number of needles used was higher in the group without residual tumor after ablation (3.1 vs. 2.4, p = 0.04). In many cases with residual tumor, needle depth was too short (2.1 vs. 6.8 mm tumor overlap beyond the most proximal needle tip, p < 0.01). The use of a stereotactic navigation system in 10 cases resulted in a lower NDiv value (2.1° vs. 5.6°, p < 0.01). Thus, correct needle placement seems to be a crucial factor for success and the assistance of a stereotactic navigation system might be helpful. As most important geometrical parameter TACD could be identified. Main reasons for high TACD were insufficient needle depth and a lesion location out of the needle plane.


Assuntos
Carcinoma Hepatocelular , Eletroporação , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Agulhas , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...