Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658140

RESUMO

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Assuntos
Fraturas Ósseas , Granuloma de Corpo Estranho , Infecções dos Tecidos Moles , Humanos , Masculino , Feminino , Criança , Magnésio , Implantes Absorvíveis , Granuloma de Corpo Estranho/etiologia , Infecções dos Tecidos Moles/etiologia , Fraturas Ósseas/etiologia , Ligas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos
2.
J Clin Med ; 12(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37109351

RESUMO

BACKGROUND: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. OBJECTIVE: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. MATERIAL AND METHODS: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. RESULTS: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. CONCLUSIONS: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.

3.
Pediatr Radiol ; 52(12): 2368-2376, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35606529

RESUMO

BACKGROUND: Resorption of magnesium-based alloy bioabsorbable screws produces hydrogen gas, which can be mistaken as a sign of infection and may affect the physis or fixed bone fragment. OBJECTIVE: We evaluated the temporal and spatial occurrence of gas and the occurrence of a breakage of the fixed bone fragment or screw following magnesium screw fixation. MATERIALS AND METHODS: Radiographs of paediatric patients treated with magnesium screws were retrospectively reviewed. Temporal occurrence and distribution of gas in the bone, the physis and soft tissues, breakage of the screw or fixed bone fragment and joint effusion were assessed. RESULTS: One hundred and three radiographs in 35 paediatric patients were reviewed (mean age: 10.6 years). Follow-up ranged from 1 to 730 days. Gas in the bone increases up to week 5, remains constant up to week 16 and then decreases. Gas in soft tissues, intra-articular gas and joint effusions gradually reduce over time. In 1/23 (4.3%) patients with an open physis, gas intrusion into the physis occurred. Breakage of the bone fragment fixated by the screw was observed in 4/35 (11.4%) patients within the first 6 weeks. Screw breakage was observed in 16/35 (45.7%) patients, with a median time to first detection of 300 days. CONCLUSION: Gas bubbles in bone and soft tissue are normal findings in the context of screw resorption and should not be confused with soft-tissue infection or osteomyelitis. Gas is rarely visible in the physis. Breakage of the fixed bone fragment and/or screw can occur.


Assuntos
Fraturas Ósseas , Magnésio , Humanos , Criança , Implantes Absorvíveis , Estudos Retrospectivos , Parafusos Ósseos , Ligas , Fraturas Ósseas/etiologia
4.
Children (Basel) ; 9(4)2022 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-35455515

RESUMO

INTRODUCTION: Following osteosynthesis, children generally require a second surgery to remove the hardware. This becomes unnecessary, by using resorbable implants. Limiting the number of required surgeries and their associated risks, this technique provides critical aspects of minimally invasive surgery. This review focuses on resorbable implants for osteosynthesis for the treatment of fractures in children and discusses their clinical features. METHOD: We provide an overview of the two most common technologies used in resorbable osteosynthesis materials: polymer- and magnesium-based alloys. Clinical examples of osteosynthesis are presented using polymer-based ActivaTM products and magnesium-based Magnezix® products. RESULTS: Polymer-based implants demonstrate surgical safety and efficacy. Due to their elasticity, initial placement of polymer-based products may demonstrate technical challenges. However, stability is maintained over the course of healing. While maintaining good biocompatibility, the rate of polymer-resorption may be controlled by varying the composition of polyesters and copolymers. Similarly, magnesium-based implants demonstrate good mechanical stability and resorption rates, while these characteristics may be controlled by varying alloy components. One of the significant shortcomings of magnesium is that metabolism results in the production of hydrogen gas. Both technologies provide equally good results clinically and radiographically, when compared to non-resorbable implants. CONCLUSION: Resorbable osteosynthesis materials demonstrate similar therapeutic results as conventional materials for osteosynthesis. Resorbable implants may have the potential to improve patient outcomes, by sparing children a second surgery for hardware removal.

5.
Atherosclerosis ; 190(2): 443-51, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16569408

RESUMO

AIMS: In advanced human atherosclerotic plaques infiltrating T cells congregate at sites of plaque rupture. However, little is known about the systemic activation of circulating T cells in acute coronary syndromes as a prerequisite for recruitment to atherosclerotic lesions. METHODS AND RESULTS: As a measure for specific lymphocyte activation we analyzed IFN-gamma production of T cells after stimulation with a superantigen and expression of CXCR-3 and CCR-3 in patients with acute myocardial infarction (AMI), unstable angina (uAP) or stable angina (sAP). Furthermore, concentrations of the circulating cytokines interleukin (IL)-1, IL-6, IL-1beta, IL-12 p70 and RANTES that modify T cell function were measured. In uAP an increased Th1 and a decreased Th2 response was identified by enhanced interferon-gamma generation of T lymphocytes, increased levels of IL-1beta, IL-12 p70 and RANTES and decreased expression of CCR3. In AMI a systemic inflammatory reaction predominates with enhanced expression of the early activation marker CD69 on T lymphocytes and elevated levels of IL-6 and IL-10 that suppress Th1 activation. CONCLUSION: Interferon-gamma production of activated T cells in acute coronary syndromes may, therefore, be governed by the release of specific pro- and anti-lymphocyte activating cytokines.


Assuntos
Doença das Coronárias/sangue , Doença das Coronárias/imunologia , Citocinas/sangue , Citocinas/imunologia , Linfócitos T/imunologia , Doença Aguda , Idoso , Angina Instável/sangue , Angina Instável/imunologia , Quimiocina CCL5/sangue , Feminino , Humanos , Interleucinas/sangue , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...