Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Card Surg ; 37(12): 4740-4747, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36478440

RESUMO

BACKGROUND: Direct oral anticoagulants (DOACs) are frequently prescribed for the management of atrial fibrillation and venous thrombosis. There is a lack of published data on the utilization of DOACs in individuals who have undergone recent cardiac surgery. The purpose of this study was to evaluate the safety and efficacy of apixaban and rivaroxaban compared to warfarin in patients postcardiac surgery. METHODS: In this retrospective cohort study, patients were separated into a DOAC cohort or a warfarin cohort based on the agent they received after cardiac surgery. Patients could be included if they were ≥18 years of age and received or were discharged on either rivaroxaban, apixaban, or warfarin within 7 days after cardiac surgery. The primary outcome for the study was the rate of International Society on Thrombosis and Hemostasis (ISTH) major bleeding during hospitalization and for 30 days following discharge or until first follow-up appointment. RESULTS: There were a total of 194 patients included in the analysis, 97 in the DOAC cohort and 97 in the warfarin cohort. Four patients (4.1%) in the DOAC group experienced ISTH major bleeding, while 2 patients (2.1%) in the warfarin cohort experienced ISTH major bleeding (p = 0.68). No patients in the DOAC cohort experienced a thrombotic event, whereas 2 patients (2.1%) in the warfarin cohort experienced a thrombotic complication (p = 0.5). CONCLUSION: Apixaban and rivaroxaban demonstrated similar safety when compared to a matched cohort of warfarin patients. Larger prospective randomized studies are needed to confirm these findings.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Dabigatrana/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Estudos Prospectivos , Estudos Retrospectivos , Rivaroxabana/efeitos adversos , Varfarina/efeitos adversos
2.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...