1.
Artigo em Inglês | MEDLINE | ID: mdl-38479560

RESUMO

PURPOSE: Neutron capture enhanced particle therapy (NCEPT) is a proposed augmentation of charged particle therapy that exploits thermal neutrons generated internally, within the treatment volume via nuclear fragmentation, to deliver a biochemically targeted radiation dose to cancer cells. This work is the first experimental demonstration of NCEPT, performed using both carbon and helium ion beams with 2 different targeted neutron capture agents (NCAs). METHODS AND MATERIALS: Human glioblastoma cells (T98G) were irradiated by carbon and helium ion beams in the presence of NCAs [10B]-BPA and [157Gd]-DOTA-TPP. Cells were positioned within a polymethyl methacrylate phantom either laterally adjacent to or within a 100 × 100 × 60 mm spread out Bragg peak (SOBP). The effect of NCAs and location relative to the SOBP on the cells was measured by cell growth and survival assays in 6 independent experiments. Neutron fluence within the phantom was characterized by quantifying the neutron activation of gold foil. RESULTS: Cells placed inside the treatment volume reached 10% survival by 2 Gy of carbon or 2 to 3 Gy of helium in the presence of NCAs compared with 5 Gy of carbon and 7 Gy of helium with no NCA. Cells placed adjacent to the treatment volume showed a dose-dependent decrease in cell growth when treated with NCAs, reaching 10% survival by 6 Gy of carbon or helium (to the treatment volume), compared with no detectable effect on cells without NCA. The mean thermal neutron fluence at the center of the SOBP was approximately 2.2 × 109 n/cm2/Gy (relative biological effectiveness) for the carbon beam and 5.8 × 109 n/cm2/Gy (relative biological effectiveness) for the helium beam and gradually decreased in all directions. CONCLUSIONS: The addition of NCAs to cancer cells during carbon and helium beam irradiation has a measurable effect on cell survival and growth in vitro. Through the capture of internally generated neutrons, NCEPT introduces the concept of a biochemically targeted radiation dose to charged particle therapy. NCEPT enables the established pharmaceuticals and concepts of neutron capture therapy to be applied to a wider range of deeply situated and diffuse tumors, by targeting this dose to microinfiltrates and cells outside of defined treatment regions. These results also demonstrate the potential for NCEPT to provide an increased dose to tumor tissue within the treatment volume, with a reduction in radiation doses to off-target tissue.

2.
Anticancer Res ; 43(5): 2259-2264, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37097649

RESUMO

BACKGROUND/AIM: In vivo dosimetry can prevent dose delivery errors by directly measuring the dose of radiation administered to a patient. However, a method for in vivo dosimetry during carbon ion radiotherapy (CIRT) has not been established. Therefore, we investigated data from in vivo dosimetry of the urethra during CIRT for prostate cancer using small spherical diode dosimeters (SSDDs). PATIENTS AND METHODS: This study included five patients enrolled in a clinical trial (jRCT identifier: jRCTs032190180) on which the use of four-fraction CIRT for prostate cancer was examined. The urethral dose during CIRT for prostate cancer was measured using the SSDDs inserted into the ureteral catheter. The relative error between the in vivo and calculated doses obtained using the Xio-N treatment planning system was determined. Additionally, a dose-response stability test for the in vivo dosimeter was performed under clinical conditions. RESULTS: The relative error between the in vivo and calculated urethral doses ranged from 6 to 12%. The dose-response stability under clinical conditions of the measured dose was ≤1%. Therefore, an error >1% would be due to an interfractional patient setup error in the large dose gradient in the urethra. CONCLUSION: The usefulness of in vivo dosimetry using SSDDs in CIRT and SSDDs' potential for detecting dose delivery errors during CIRT is herein highlighted.


Assuntos
Braquiterapia , Radioterapia com Íons Pesados , Neoplasias da Próstata , Masculino , Humanos , Uretra , Próstata , Radiometria/métodos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/métodos
3.
Radiol Phys Technol ; 16(2): 319-324, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37087722

RESUMO

The stopping-power ratio (SPR) of body tissues relative to water depends on the particle energy and mean excitation energy (I value) of the tissues. Effective energies to minimize the range error in proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions and elemental I values have been updated in recent studies. We investigated the effects of these updates on SPR estimation for computed tomography-based treatment planning. The updates led to an increase of up to 0.5% in the SPRs of soft tissues, whereas they led to a decrease of up to 1.9% in the SPRs of bone tissues compared with the current clinical settings. For 44 proton beams planned for 15 randomly sampled patients, the mean water-equivalent target depth change was - 0.2 mm with a standard deviation of 0.2 mm. The maximum change was - 0.6 mm, which we consider to be insignificant in clinical practice.


Assuntos
Terapia com Prótons , Humanos , Hélio/uso terapêutico , Neônio/uso terapêutico , Oxigênio/uso terapêutico , Carbono/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Água
4.
Cancer Med ; 12(2): 1540-1551, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35852142

RESUMO

BACKGROUND: To evaluate the clinical relative biological effectiveness (RBE) of carbon-ion radiotherapy (C-ion RT) for prostate cancer. METHODS: The records of 262 patients with low-risk prostate cancer (median age, 65 [47-80] years) treated with C-ion RT at QST Hospital, National Institutes for Quantum Science and Technology in Japan during 2000-2018 were reviewed retrospectively. Four different protocol outcomes and prostate-specific antigen (PSA) responses were evaluated. The median follow-up was 8.4 years. The Kaplan-Meier method was used to estimate the biochemical or clinical failure-free rate (BCFFR). Clinical RBE was calculated using the tumor control probability model. RESULTS: The 5-, 7-, and 10-year BCFFRs were 91.7%, 83.8%, and 73.2%, respectively. The 10-year BCFFRs of patients who received C-ion RT at 66 Gy (RBE) in 20 fractions, 63 Gy (RBE) in 20 fractions, and 57.6 Gy (RBE) in 16 fractions were 81.4%, 70.9%, and 68.9%, respectively. The PSA level and density during follow-up were better in the patients treated with the lower fraction size. A higher PSA nadir and shorter time to PSA nadir were risk factors for biochemical or clinical failure by multivariate Cox regression. The tumor control probability analysis showed that the estimated clinical RBE values to achieve an 80% BCFFR at 10 years for 20, 16, and 12 fractions were 2.19 (2.18-2.24), 2.16 (2.14-2.23), and 2.12 (2.09-2.21), respectively. CONCLUSIONS: Using clinical data from low-risk prostate cancer patients, we showed the clinical RBE of C-ion RT decreased with increasing dose per fraction.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estudos Retrospectivos , Eficiência Biológica Relativa , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Carbono
5.
J Radiat Res ; 63(2): 221-229, 2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35021226

RESUMO

Time dependence of relative biological effectiveness (RBE) of carbon ions for skin damage was investigated to answer the question of whether the flat distribution of biological doses within a Spread-Out Bragg peak (SOBP) which is designed based on in vitro cell kill could also be flat for in vivo late responding tissue. Two spots of Indian ink intracutaneously injected into the legs of C3H mice were measured by calipers. An equieffective dose to produce 30% skin contraction was calculated from a dose-response curve and used to calculate the RBE of carbon ion beams. We discovered skin contraction progressed after irradiation and then reached a stable/slow progression phase. Equieffective doses decreased with time and the decrease was most prominent for gamma rays and least prominent for 100 keV/µm carbon ions. Survival parameter of alpha but not beta in the linear-quadratic model is closely related to the RBE of carbon ions. Biological doses within the SOBP increased with time but their distribution was still flat up to 1 year after irradiation. The outcomes of skin contraction studies suggest that (i) despite the higher RBE for skin contracture after carbon ions compared to gamma rays, gamma rays can result in a more severe late effect of skin contracture. This is due to the carbon effect saturating at a lower dose than gamma rays, and (ii) the biological dose distribution throughout the SOBP remains approximately the same even one year after exposure.


Assuntos
Contratura , Transferência Linear de Energia , Animais , Carbono , Sobrevivência Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Raios gama , Íons , Camundongos , Camundongos Endogâmicos C3H , Eficiência Biológica Relativa
6.
Cancers (Basel) ; 13(6)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802835

RESUMO

(1) Background: among all types of radiation, very heavy ions, such as Neon (Ne) or Argon (Ar), are the optimum candidates for hypoxic tumor treatments due to their reduced oxygen enhancement effect. However, their pioneering clinical use in the 1970s was halted due to severe side effects. The aim of this work was to provide a first proof that the combination of very heavy ions with minibeam radiation therapy leads to a minimization of toxicities and, thus, opening the door for a renewed use of heavy ions for therapy; (2) Methods: mouse legs were irradiated with either Ne MBRT or Ne broad beams at the same average dose. Skin toxicity was scored for a period of four weeks. Histopathology evaluations were carried out at the end of the study; (3) Results: a significant difference in toxicity was observed between the two irradiated groups. While severe da-mage, including necrosis, was observed in the broad beam group, only light to mild erythema was present in the MBRT group; (4) Conclusion: Ne MBRT is significantly better tolerated than conventional broad beam irradiations.

7.
Phys Med ; 82: 72-78, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33588230

RESUMO

The use of carbon ion beams in cancer therapy (also known as hadron therapy) is steadily growing worldwide; therefore, the demand for more efficient dosimetry systems is also increasing because daily quality assurance (QA) measurements of hadron radiotherapy is one of the most complex and time consuming tasks. The aim of this study is to develop a two-dimensional dosimetry system that offers high spatial resolution, a large field of view, quick data response, and a linear dose-response relationship. We demonstrate the dose imaging performance of a novel digital dose imager using carbon ion beams for hadron therapy. The dose imager is based on a newly-developed gaseous detector, a well-type glass gas electron multiplier. The imager is successfully operated in a hadron therapy facility with clinical intensity beams for radiotherapy. It features a high spatial resolution of less than 1 mm and an almost linear dose-response relationship with no saturation and very low linear-energy-transfer dependence. Experimental results show that the dose imager has the potential to improve dosimetry accuracy for daily QA.


Assuntos
Carbono , Elétrons , Gases , Transferência Linear de Energia , Radiometria
8.
Anticancer Res ; 40(11): 6429-6435, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33109581

RESUMO

BACKGROUND/AIM: The local control rate of chondrosarcomas treated with carbon-ion radiotherapy (CIRT) worsens as tumour size increases, possibly because of the intra-tumoural linear energy transfer (LET) distribution. This study aimed to evaluate the relationship between local recurrence and intra-tumoural LET distribution in chondrosarcomas treated with CIRT. PATIENTS AND METHODS: Thirty patients treated with CIRT for grade 2 chondrosarcoma were included. Dose-averaged LET (LETd) distribution was calculated by the treatment planning system, and the relationship between LETd distribution in the planning tumour volume (PTV) and local control was evaluated. RESULTS: The mean LETd value in PTV was similar between cases with and without recurrence. Recurrence was not observed in cases where the effective minimum LETd value exceeded 40 keV/µm. CONCLUSION: LETd distribution in PTV is associated with local control in chondrosarcomas and patients treated with ion beams of higher LETd may have an improved local control rate for unresectable chondrosarcomas.


Assuntos
Condrossarcoma/radioterapia , Radioterapia com Íons Pesados , Recidiva Local de Neoplasia/radioterapia , Doses de Radiação , Algoritmos , Condrossarcoma/patologia , Feminino , Humanos , Transferência Linear de Energia , Masculino , Método de Monte Carlo , Recidiva Local de Neoplasia/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Carga Tumoral
9.
Radiother Oncol ; 153: 272-278, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32898559

RESUMO

BACKGROUND AND PURPOSE: Several studies have focused on increasing the linear energy transfer (LET) within tumours to achieve higher biological effects in carbon-ion radiotherapy (C-ion RT). However, it remains unclear whether LET affects late complications. We assessed whether physical dose and LET distribution can be specific factors for late rectal complications in C-ion RT. MATERIALS AND METHODS: Overall, 134 patients with uterine carcinomas were registered and retrospectively analysed. Of 134 patients, 132 who were followed up for >6 months were enrolled. The correlations between the relative biological effectiveness (RBE)-weighted dose based on the Kanai model (the ostensible "clinical dose"), dose-averaged LET (LETd), or physical dose and rectal complications were evaluated. Rectal complications were graded according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. RESULTS: Nine patients developed grade 3 or 4 late rectal complications. Linear regression analysis found that D2cc in clinical dose was the sole risk factor for ≥grade 3 late rectal complications (p = 0.012). The receiver operating characteristic analysis found that D2cc of 60.2 Gy (RBE) was a suitable cut-off value for predicting ≥grade 3 late rectal complications. Among 35 patients whose rectal D2cc was ≥60.2 Gy (RBE), no correlations were found between severe rectal toxicities and LETd alone or physical dose per se. CONCLUSION: We demonstrated that severe rectal toxicities were related to the rectal D2cc of the clinical dose in C-ion RT. However, no correlations were found between severe rectal toxicities and LETd alone or physical dose per se.


Assuntos
Transferência Linear de Energia , Terapia com Prótons , Carbono , Humanos , Eficiência Biológica Relativa , Estudos Retrospectivos
10.
Clin Transl Radiat Oncol ; 21: 19-24, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31886424

RESUMO

BACKGROUND AND PURPOSE: High linear energy transfer (LET) radiation carbon-ion radiotherapy (C-ion RT) is one of the most promising modalities for treating unresectable primary pancreatic cancers. However, how LET contributes to a therapeutic effect is not clear. To assess whether there is an enhanced effect of high LET radiation on tumour control, we aimed to determine the impact of dose-averaged LET on local control (LC) of primary pancreatic tumours. MATERIALS AND METHODS: A retrospective analysis of 18 patients with primary pancreatic carcinomas treated with definitive C-ion RT with concurrent chemotherapy in 2013 was conducted. The dose of irradiation was 55.2 Gy (RBE). The relationship between dose-averaged LET and LC of primary tumours was evaluated. RESULTS: All patients had histologically confirmed adenocarcinoma. The median follow-up duration was 22 months. The actuarial LC and overall survival (OS) at 18 months were 62.5% and 70.1%, respectively. There were no cases of grade ≥3 late toxicities observed. Local recurrences developed in four patients (22%), all of which were infield central recurrences. Although there were no significant differences in gross tumour volume (GTV) dose coverage, patients with higher minimum dose-averaged LET (LETmin) values within the GTV had better LC (dose-averaged LETmin ≥44 keV/microm; 18-months LC 100.0% vs 34.3%; p = 0.0366). CONCLUSION: Dose-averaged LETmin within the GTV was significantly associated with LC of primary pancreatic cancers. Our data suggest that outcomes for patients with unresectable primary pancreatic cancers receiving C-ion RT can be improved by modulating the dose-averaged LET within the GTV.

12.
J Radiat Res ; 60(2): 178-188, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624699

RESUMO

The effects of the charged ion species 4He, 12C and 20Ne on glioblastoma multiforme (GBM) T98G, U87 and LN18 cell lines were compared with the effects of 200 kVp X-rays (1.7 keV/µm). These cell lines have different genetic profiles. Individual GBM relative biological effectiveness (RBE) was estimated in two ways: the RBE10 at 10% survival fraction and the RBE2Gy after 2 Gy doses. The linear quadratic model radiosensitivity parameters α and ß and the α/ß ratio of each ion type were determined as a function of LET. Mono-energetic 4He, 12C and 20Ne ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Sciences in Chiba, Japan. Colony-formation assays were used to evaluate the survival fractions. The LET of the various ions used ranged from 2.3 to 100 keV/µm (covering the depth-dose plateau region to clinically relevant LET at the Bragg peak). For U87 and LN18, the RBE10 increased with LET and peaked at 85 keV/µm, whereas T98G peaked at 100 keV/µm. All three GBM α parameters peaked at 100 keV/µm. There is a statistically significant difference between the three GBM RBE10 values, except at 100 keV/µm (P < 0.01), and a statistically significant difference between the α values of the GBM cell lines, except at 85 and 100 keV/µm. The biological response varied depending on the GBM cell lines and on the ions used.


Assuntos
Carbono/farmacologia , Glioblastoma/radioterapia , Íons Pesados , Hélio/farmacologia , Transferência Linear de Energia/efeitos da radiação , Neônio/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Humanos , Radiobiologia
13.
Radiat Prot Dosimetry ; 183(1-2): 45-49, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624731

RESUMO

Hypofractionated carbon-ion therapy has been applied to treatment of several tumours. In this case, relative biological effectiveness (RBE) at high dose region must be considered, however, the RBE calculated physically has been not verified biologically. In this study, spheroid technique was adopted to estimate RBE in wide dose range. Cells were irradiated with X-rays and heavy-ions with LET of 13, 35, 100 and 300 keV/µm with monolayer and spheroid condition. Surviving fractions in wide dose range (0-15 Gy) were obtained to combined monolayer with spheroid survival data. The linear-quadratic and multi-target single-hit equation fitted well in survival data at low dose, and high dose region, respectively. A multi-process equation showed best fitting for survival data in wide dose range. RBE values of heavy-ions could be estimated by combination of monolayer and spheroid data. The values converged at 1.1-1.4 and varied by LET values at high and low dose region, respectively.


Assuntos
Radioterapia com Íons Pesados , Melanoma/radioterapia , Eficiência Biológica Relativa , Esferoides Celulares/efeitos da radiação , Argônio/química , Carbono/química , Sobrevivência Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Íons Pesados , Humanos , Transferência Linear de Energia , Software , Células Tumorais Cultivadas , Raios X
14.
Radiat Prot Dosimetry ; 183(1-2): 160-166, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30668821

RESUMO

An experimental and simulation-based study was performed on a 12C ion minibeam radiation therapy (MBRT) field produced with a clinical broad beam and a brass multi-slit collimator (MSC). Silicon-on-insulator (SOI) microdosimeters developed at the Centre for Medical Radiation Physics (CMRP) with micron sized sensitive volumes were used to measure the microdosimetric spectra at varying positions throughout the MBRT field and the corresponding dose-mean lineal energies and RBE for 10% cell survival (RBE10) were calculated using the modified Microdosimetric Kinetic Model (MKM). An increase in the average RBE10 of ∼30% and 10% was observed in the plateau region compared to broad beam for experimental and simulation values, respectively. The experimental collimator misalignment was determined to be 0.7° by comparison between measured and simulated microdosimetric spectra at varying collimator angles. The simulated dose-mean lineal energies in the valley region between minibeams were found to be higher on average than in the minibeams due to higher LET particles being produced in these regions from the MSC. This work presents the first experimental microdosimetry measurements and characterisation of the local biological effectiveness in a MBRT field.


Assuntos
Microtecnologia/métodos , Radiometria/métodos , Eficiência Biológica Relativa , Simulação por Computador , Radioterapia com Íons Pesados , Transferência Linear de Energia , Silício
15.
Cancer Sci ; 110(1): 303-309, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30417485

RESUMO

Prognosis is usually grim for those with liver metastasis from colorectal cancer (CRC) who cannot receive resection. Radiation therapy can be an option for those unsuitable for resection, with carbon ion radiotherapy (CIRT) being more effective and less toxic than X-ray due to its physio-biological characteristics. The objective of this study is to identify the optimal dose of single fraction CIRT for colorectal cancer liver metastasis. Thirty-one patients with liver metastasis from CRC were enrolled in the present study. Twenty-nine patients received a single-fraction CIRT, escalating the dose from 36 Gy (RBE) in 5% to 10% increments until unacceptable incidence of dose-limiting toxicity was observed. Dose-limiting toxicity was defined as grade ≥3 acute toxicity attributed to radiotherapy. The prescribed doses were as follows: 36 Gy (RBE) (3 cases), 40 Gy (2 cases), 44 Gy (4 cases), 46 Gy (6 cases), 48 Gy (3 cases), 53 Gy (8 cases) and 58 Gy (3 cases). Dose-limiting toxicity was not observed, but late grade 3 liver toxicity due to biliary obstruction was observed in 2 patients at 53 Gy (RBE). Both cases had lesions close to the hepatic portal region, and, therefore, the dose was escalated to 58 Gy (RBE), limited to peripheral lesions. The 3-year actuarial overall survival rate of all 29 patients was 78%, and the median survival time was 65 months. Local control improved significantly at ≥53 Gy (RBE), with a 3-year actuarial local control rate of 82%, compared to 28% in lower doses. Treatment for CRC liver metastasis with single-fraction CIRT appeared to be safe up to 58 Gy (RBE) as long as the central hepatic portal region was avoided.


Assuntos
Neoplasias Colorretais/radioterapia , Radioterapia com Íons Pesados/métodos , Neoplasias Hepáticas/radioterapia , Dosagem Radioterapêutica , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/patologia , Relação Dose-Resposta à Radiação , Feminino , Radioterapia com Íons Pesados/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Prognóstico
16.
J Radiat Res ; 60(1): 59-68, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30452663

RESUMO

Glioblastoma (GBM), a Grade IV brain tumour, is a well-known radioresistant cancer. To investigate one of the causes of radioresistance, we studied the capacity for potential lethal damage repair (PLDR) of three altered strains of GBM: T98G, U87 and LN18, irradiated with various ions and various levels of linear energy transfer (LET). The GBM cells were exposed to 12C and 28Si ion beams with LETs of 55, 100 and 200 keV/µm, and with X-ray beams of 1.7 keV/µm. Mono-energetic 12C ions and 28Si ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Science, Chiba, Japan. Clonogenic assays were used to determine cell inactivation. The ability of the cells to repair potential lethal damage was demonstrated by allowing one identical set of irradiated cells to repair for 24 h before subplating. The results show there is definite PLDR with X-rays, some evidence of PLDR at 55 keV/µm, and minimal PLDR at 100 keV/µm. There is no observable PLDR at 200 keV/µm. This is the first study, to the authors' knowledge, demonstrating the capability of GBM cells to repair potential lethal damage following charged ion irradiations. It is concluded that a GBM's PLDR is dependent on LET, dose and GBM strain; and the more radioresistant the cell strain, the greater the PLDR.


Assuntos
Dano ao DNA , Reparo do DNA , Glioblastoma/radioterapia , Íons Pesados , Transferência Linear de Energia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos da radiação , Glioblastoma/patologia , Humanos , Raios X
17.
Med Phys ; 45(11): e1096-e1110, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30421806

RESUMO

Carbon ion radiotherapy (CIRT) is developing toward a versatile tool in radiotherapy; however, the increased relative biological effectiveness (RBE) of carbon ions in tumors and normal tissues with respect to photon irradiation has to be considered by mathematical models in treatment planning. As a consequence, dose prescription and definition of dose constraints are performed in terms of RBE weighted rather than absorbed dose. The RBE is a complex quantity, which depends on physical variables, such as dose and beam quality as well as on normal tissue- or tumor-specific factors. At present, three RBE models are employed in CIRT: (a) the mixed-beam model, (b) the Microdosimetric Kinetic Model (MKM), and (c) the local effect model. While the LEM is used in Europe, the other two models are employed in Japan, and unfortunately, the concepts of how the nominal RBE-weighted dose is determined and prescribed differ significantly between the European and Japanese centers complicating the comparison, transfer, and reproduction of clinical results. This has severe impact on the way treatments should be prescribed, recorded, and reported. This contribution reviews the concept of the clinical application of the different RBE models and the ongoing clinical CIRT trials in Japan and Europe. Limitations of the RBE models and the resulting radiobiological issues in clinical CIRT trials are discussed in the context of current clinical evidence and future challenges.


Assuntos
Ensaios Clínicos como Assunto , Radioterapia com Íons Pesados/métodos , Radiobiologia , Humanos , Eficiência Biológica Relativa
18.
Int J Radiat Oncol Biol Phys ; 102(5): 1551-1559, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30076985

RESUMO

PURPOSE: To investigate the suitability of the linear-quadratic (LQ) and universal survival curve (USC) models in describing the 3-year tumor control probability data of patients with stage I non-small cell lung cancer treated with carbon-ion radiation therapy. Carbon-ion radiation therapy was given at a total dose of 59.4 to 95.4 Gy (relative biological effectiveness [RBE]) in 18 fractions, at 72 Gy[RBE] in 9 fractions, at 52.8 to 60 Gy[RBE] in 4 fractions, and at 28 to 50 Gy[RBE] in a single fraction. METHODS AND MATERIALS: A meta-analysis of published clinical data from 394 patients presenting with early-stage non-small cell lung cancer was conducted. Tumor control probability modeling based on the LQ and USC models was performed by simultaneously fitting the clinical data obtained from the different fractionation schedules while considering several spread-out Bragg peak (SOBP) sizes. Radiobiological parameters were derived from the fit. On the basis of the results, a novel SOBP was created for the single-fraction regimen that was optimized with respect to the USC model and aimed at achieving a 95% local control. RESULTS: The USC model gave a better fit to the 3-year local control data than the LQ model did. The fit using various SOBP sizes yielded transition doses between 5.6 and 7.0 Gy. The results also revealed α/ß ratios between 7.4 and 9.1 Gy for the LQ model and between 7.4 and 9.4 Gy for the USC model. CONCLUSIONS: The USC model provided a better estimate of the local control rate for the single-fraction course. For the schemes with a greater number of fractions, the local control rate estimates from the LQ and USC models were comparable. A USC-based SOBP design was then created for the single-fraction schedule. The updated design resulted in a flatter RBE profile compared with the conventional SOBP design. It also gave a better clinical dose prediction to optimize the tumor control rate.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Fracionamento da Dose de Radiação , Radioterapia com Íons Pesados , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Humanos , Método de Monte Carlo , Estadiamento de Neoplasias , Probabilidade , Resultado do Tratamento
19.
Phys Med ; 51: 48-55, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29699921

RESUMO

PURPOSE: The aim of this work was to estimate typical dose equivalents to out-of-field organs during carbon-ion radiotherapy (CIRT) with a passive beam for prostate cancer treatment. Additionally, sensitivity analyses of organ doses for various beam parameters and phantom sizes were performed. METHODS: Because the CIRT out-of-field dose depends on the beam parameters, the typical values of those parameters were determined from statistical data on the target properties of patients who received CIRT at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). Using these typical beam-parameter values, out-of-field organ dose equivalents during CIRT for typical prostate treatment were estimated by Monte Carlo simulations using the Particle and Heavy-Ion Transport Code System (PHITS) and the ICRP reference phantom. RESULTS: The results showed that the dose decreased with distance from the target, ranging from 116 mSv in the testes to 7 mSv in the brain. The organ dose equivalents per treatment dose were lower than those either in 6-MV intensity-modulated radiotherapy or in brachytherapy with an Ir-192 source for organs within 40 cm of the target. Sensitivity analyses established that the differences from typical values were within ∼30% for all organs, except the sigmoid colon. CONCLUSIONS: The typical out-of-field organ dose equivalents during passive-beam CIRT were shown. The low sensitivity of the dose equivalent in organs farther than 20 cm from the target indicated that individual dose assessments required for retrospective epidemiological studies may be limited to organs around the target in cases of passive-beam CIRT for prostate cancer.


Assuntos
Radioterapia com Íons Pesados/métodos , Método de Monte Carlo , Neoplasias da Próstata/radioterapia , Humanos , Masculino , Imagens de Fantasmas
20.
J Radiat Res ; 59(suppl_1): i58-i62, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29528425

RESUMO

Variation in the relative biological effectiveness (RBE) within the irradiation field of a carbon beam makes carbon-ion radiotherapy unique and advantageous in delivering the therapeutic dose to a deep-seated tumor, while sparing surrounding normal tissues. However, it is crucial to consider the RBE, not only in designing the dose distribution during treatment planning, but also in analyzing the clinical response retrospectively. At the National Institute of Radiological Sciences, the RBE model was established based on the response of human salivary gland cells. The response was originally handled with a linear-quadratic model, and later with a microdosimetric kinetic model. Retrospective analysis with a tumor-control probability model of non-small cell cancer treatment revealed a steep dose response in the tumor, and that the RBE of the tumor was adequately estimated using the model. A commonly used normal tissue complication probability model has not yet fully been accountable for the variable RBE of carbon ions; however, analysis of rectum injury after prostate cancer treatment suggested a highly serial-organ structure for the rectum, and a steep dose response similar to that observed for tumors.


Assuntos
Fenômenos Biofísicos , Radioterapia com Íons Pesados , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Probabilidade , Eficiência Biológica Relativa