Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Case Rep ; 17(9): 2946-2950, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35755105

RESUMO

Most lymphoepithelial cysts (LECs) occur in the salivary glands and are considered one of the autoimmune syndromes caused by the human immunodeficiency virus (HIV). In this report, we present a case of pulmonary LEC without prior HIV infection, paying special attention to radiographic features. A chest radiograph revealed an oval mass with a smooth surface, localized in the left lower lung field, which was in direct contact with the diaphragm. Computed tomography showed an oval homogenous mass with a smooth surface in the lower left lobe. Further, magnetic resonance imaging demonstrated that the mass was a homogeneous internal structure with a smooth surface and a slightly high signal in T2-weighted images and a slightly low signal in T1-weighted images. Surgical resection was performed, and pathological examination confirmed the diagnosis of a pulmonary LEC. To the best of our knowledge, no cases of pulmonary LECs without prior HIV infection have been reported in the literature to date, therefore, the case presented here is considered very rare and informative.

2.
J Vasc Access ; 20(6): 666-671, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30973300

RESUMO

BACKGROUND: For subcutaneously implanted central venous ports, some complications due to prolonged placement have been reported. We investigated the appropriate puncture points and port placement sites to prevent catheter fracture in right internal jugular port placement. METHODS: This retrospective study included 709 patients who underwent right internal jugular vein puncture and port implantation in the right precordium between 1 May 2012 and 31 March 2018. The cases were divided into undamaged catheter group and damaged catheter group comprising normal and fracture cases, respectively. The catheter angle, distance from the clavicle, tip position, and curvature radius were measured from fluoroscopic images obtained at the time of implantation. The t-test was used in statistical analysis. RESULTS: Median angles were 91.6° in the undamaged catheter group and 58.0° in the damaged catheter group. Median distances were 26.0 mm in the undamaged catheter group and 36.6 mm in the damaged catheter group. Median tip positions were 51.6 mm in the undamaged catheter group and 37.5 mm in the damaged catheter group. Median curvature radii were 9.2 R in the undamaged catheter group and 7.1 R in the damaged catheter group. Significant differences were found in the angle, height, and curvature radius between the two groups. CONCLUSION: Our results indicate that a venipuncture as close to the clavicle as possible (less than 3 cm) and a gentle catheter curve (close to 90° angle) are associated with a lower risk of catheter fracture.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Falha de Equipamento , Veias Jugulares , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Venoso Central/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...