Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Cognition ; 240: 105603, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37647742

RESUMO

The willingness to exert effort for reward is essential but comes at the cost of fatigue. Theories suggest fatigue increases after both physical and cognitive exertion, subsequently reducing the motivation to exert effort. Yet a mechanistic understanding of how this happens on a moment-to-moment basis, and whether mechanisms are common to both mental and physical effort, is lacking. In two studies, participants reported momentary (trial-by-trial) ratings of fatigue during an effort-based decision-making task requiring either physical (grip-force) or cognitive (mental arithmetic) effort. Using a novel computational model, we show that fatigue fluctuates from trial-to-trial as a function of exerted effort and predicts subsequent choices. This mechanism was shared across the domains. Selective to the cognitive domain, committing errors also induced momentary increases in feelings of fatigue. These findings provide insight into the computations underlying the influence of effortful exertion on fatigue and motivation, in both physical and cognitive domains.


Assuntos
Emoções , Motivação , Humanos , Recompensa , Cognição
2.
Psychon Bull Rev ; 30(5): 1975-1987, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37038030

RESUMO

Contemporary models of decision-making under risk focus on estimating the final value of each alternative course of action. According to such frameworks, information that has no capacity to alter a future payoff (i.e., is "non-instrumental") should have little effect on one's preference for risk. Importantly, however, recent work has shown that information, despite being non-instrumental, may nevertheless exert a striking influence on behavior. Here, we tested whether the opportunity to passively observe the sequence of events following a decision could modulate risky behavior, even if that information could not possibly influence the final result. Across three experiments, 71 individuals chose to accept or reject gambles on a five-window slot machine. If a gamble was accepted, each window was sequentially revealed prior to the outcome being declared. Critically, we informed participants about which windows would subsequently provide veridical information about the gamble outcome, should that gamble be accepted. Our analyses revealed three key findings. First, the opportunity to observe the consequences of one's choice significantly increased the likelihood of gambling, despite that information being entirely non-instrumental. Second, this effect generalized across different stakes. Finally, choices were driven predominantly by the likelihood that information could result in an earlier resolution of uncertainty. These findings demonstrate the importance of anticipatory information to decision-making under risk. More broadly, we provide strong evidence for the utility of non-instrumental information, by demonstrating its capacity to modulate primary economic decisions that should be driven by more motivationally salient variables associated with risk and reward.


Assuntos
Jogo de Azar , Humanos , Assunção de Riscos , Incerteza , Probabilidade , Recompensa , Tomada de Decisões
3.
J Cereb Blood Flow Metab ; 43(8): 1285-1300, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37026455

RESUMO

In this study we evaluate the performance of a fully automated analytical framework for FDOPA PET neuroimaging data, and its sensitivity to demographic and experimental variables and processing parameters. An instance of XNAT imaging platform was used to store the King's College London institutional brain FDOPA PET imaging archive, alongside individual demographics and clinical information. By re-engineering the historical Matlab-based scripts for FDOPA PET analysis, a fully automated analysis pipeline for imaging processing and data quantification was implemented in Python and integrated in XNAT. The final data repository includes 892 FDOPA PET scans organized from 23 different studies. We found good reproducibility of the data analysis by the automated pipeline (in the striatum for the Kicer: for the controls ICC = 0.71, for the psychotic patients ICC = 0.88). From the demographic and experimental variables assessed, gender was found to most influence striatal dopamine synthesis capacity (F = 10.7, p < 0.001), with women showing greater dopamine synthesis capacity than men. Our automated analysis pipeline represents a valid resourse for standardised and robust quantification of dopamine synthesis capacity using FDOPA PET data. Combining information from different neuroimaging studies has allowed us to test it comprehensively and to validate its replicability and reproducibility performances on a large sample size.


Assuntos
Di-Hidroxifenilalanina , Dopamina , Masculino , Humanos , Feminino , Dopamina/metabolismo , Reprodutibilidade dos Testes , Tomografia por Emissão de Pósitrons/métodos , Neuroimagem
4.
Radiother Oncol ; 183: 109592, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870608

RESUMO

BACKGROUND AND PURPOSE: Tumour hypoxia is prognostic in head and neck cancer (HNC), associated with poor loco-regional control, poor survival and treatment resistance. The advent of hybrid MRI - radiotherapy linear accelerator or 'MR Linac' systems - could permit imaging for treatment adaptation based on hypoxic status. We sought to develop oxygen-enhanced MRI (OE-MRI) in HNC and translate the technique onto an MR Linac system. MATERIALS AND METHODS: MRI sequences were developed in phantoms and 15 healthy participants. Next, 14 HNC patients (with 21 primary or local nodal tumours) were evaluated. Baseline tissue longitudinal relaxation time (T1) was measured alongside the change in 1/T1 (termed ΔR1) between air and oxygen gas breathing phases. We compared results from 1.5 T diagnostic MR and MR Linac systems. RESULTS: Baseline T1 had excellent repeatability in phantoms, healthy participants and patients on both systems. Cohort nasal concha oxygen-induced ΔR1 significantly increased (p < 0.0001) in healthy participants demonstrating OE-MRI feasibility. ΔR1 repeatability coefficients (RC) were 0.023-0.040 s-1 across both MR systems. The tumour ΔR1 RC was 0.013 s-1 and the within-subject coefficient of variation (wCV) was 25% on the diagnostic MR. Tumour ΔR1 RC was 0.020 s-1 and wCV was 33% on the MR Linac. ΔR1 magnitude and time-course trends were similar on both systems. CONCLUSION: We demonstrate first-in-human translation of volumetric, dynamic OE-MRI onto an MR Linac system, yielding repeatable hypoxia biomarkers. Data were equivalent on the diagnostic MR and MR Linac systems. OE-MRI has potential to guide future clinical trials of biology guided adaptive radiotherapy.


Assuntos
Neoplasias de Cabeça e Pescoço , Oxigênio , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Hipóxia , Prognóstico , Aceleradores de Partículas
5.
J Cereb Blood Flow Metab ; 42(11): 2066-2079, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35748031

RESUMO

Chemical-exchange spin-lock (CESL) MRI can map regional uptake and utilisation of glucose in the brain at high spatial resolution (i.e sub 0.2 mm3 voxels). We propose two quantitative kinetic models to describe glucose-induced changes in tissue R1ρ and apply them to glucoCESL MRI data acquired in tumour-bearing and healthy rats. When assuming glucose transport is saturable, the maximal transport capacity (Tmax) measured in normal tissue was 3.2 ± 0.6 µmol/min/mL, the half saturation constant (Kt) was 8.8 ± 2.2 mM, the metabolic rate of glucose consumption (MRglc) was 0.21 ± 0.13 µmol/min/mL, and the cerebral blood volume (vb) was 0.006 ± 0.005 mL/mL. Values in tumour were: Tmax = 7.1 ± 2.7 µmol/min/mL, Kt = 14 ± 1.7 mM, MRglc = 0.22 ± 0.09 µmol/min/mL, vb = 0.030 ± 0.035 mL/mL. Tmax and Kt were significantly higher in tumour tissue than normal tissue (p = 0.006 and p = 0.011, respectively). When assuming glucose uptake also occurs via free diffusion, the free diffusion rate (kd) was 0.061 ± 0.017 mL/min/mL in normal tissue and 0.12 ± 0.042 mL/min/mL in tumour. These parameter estimates agree well with literature values obtained using other approaches (e.g. NMR spectroscopy).


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Animais , Transporte Biológico , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Glucose/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Ratos
6.
Magn Reson Med ; 86(3): 1314-1329, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33780045

RESUMO

PURPOSE: We sought to determine the degree to which oxygen extraction fraction (OEF) estimated using quantitative susceptibility mapping (QSM) depends on two critical acquisition parameters that have a significant impact on acquisition time: voxel size and final echo time. METHODS: Four healthy volunteers were imaged using a range of isotropic voxel sizes and final echo times. The 0.7 mm data were downsampled at different stages of QSM processing by a factor of 2 (to 1.4 mm), 3 (2.1 mm), or 4 (2.8 mm) to determine the impact of voxel size on each analysis step. OEF was estimated from 11 veins of varying diameter. Inter- and intra-session repeatability were estimated for the optimal protocol by repeat scanning in 10 participants. RESULTS: Final echo time was found to have no significant effect on OEF. The effect of voxel size was significant, with larger voxel sizes underestimating OEF, depending on the proximity of the vein to the superficial surface of the brain and on vein diameter. The last analysis step of estimating vein OEF values from susceptibility images had the largest dependency on voxel size. Inter-session coefficients of variation on OEF estimates of between 5.2% and 8.7% are reported, depending on the vein. CONCLUSION: QSM acquisition times can be minimized by reducing the final echo time but an isotropic voxel size no larger than 1 mm is needed to accurately estimate OEF in most medium/large veins in the brain. Such acquisitions can be achieved in under 4 min.


Assuntos
Mapeamento Encefálico , Oxigênio , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética , Consumo de Oxigênio
7.
Neuroimage ; 232: 117821, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33588030

RESUMO

Accurate regional brain quantitative PET measurements, particularly when using partial volume correction, rely on robust image registration between PET and MR images. We argue here that the precision, and hence the uncertainty, of MR-PET image registration is mainly driven by the registration implementation and the quality of PET images due to their lower resolution and higher noise compared to the structural MR images. We propose a dedicated uncertainty analysis for quantifying the precision of MR-PET registration, centred around the bootstrap resampling of PET list-mode events to generate multiple PET image realisations with different noise (count) levels. The effects of PET image reconstruction parameters, such as the use of attenuation and scatter corrections and different number of iterations, on the precision and accuracy of MR-PET registration were investigated. In addition, the performance of four software packages with their default settings for rigid inter-modality image registration were considered: NiftyReg, Vinci, FSL and SPM. Four distinct PET image distributions made of two early time frames (similar to cortical FDG) and two late frames using two amyloid PET dynamic acquisitions of one amyloid positive and one amyloid negative participants were investigated. For the investigated four PET frames, the biggest impact on the uncertainty was observed between registration software packages (up to 10-fold difference in precision) followed by the reconstruction parameters. On average, the lowest uncertainty for different PET frames and brain regions was observed with SPM and two iterations of fully quantitative image reconstruction. The observed uncertainty for the varying PET count-level (from 5% to 60%) was slightly lower than for the reconstruction parameters. We also observed that the registration uncertainty in quantitative PET analysis depends on amyloid status of the considered PET frames, with increased uncertainty (up to three times) when using post-reconstruction partial volume correction. This analysis is applicable for PET data obtained from either PET/MR or PET/CT scanners.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Tomografia por Emissão de Pósitrons/normas , Incerteza , Idoso , Estudos de Coortes , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos
8.
Med Phys ; 48(5): 2230-2244, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33533050

RESUMO

PURPOSE: Reconstructed PET images are typically noisy, especially in dynamic imaging where the acquired data are divided into several short temporal frames. High noise in the reconstructed images translates to poor precision/reproducibility of image features. One important role of "denoising" is therefore to improve the precision of image features. However, typical denoising methods achieve noise reduction at the expense of accuracy. In this work, we present a novel four-dimensional (4D) denoised image reconstruction framework, which we validate using 4D simulations, experimental phantom, and clinical patient data, to achieve 4D noise reduction while preserving spatiotemporal patterns/minimizing error introduced by denoising. METHODS: Our proposed 4D denoising operator/kernel is based on HighlY constrained backPRojection (HYPR), which is applied either after each update of OSEM reconstruction of dynamic 4D PET data or within the recently proposed kernelized reconstruction framework inspired by kernel methods in machine learning. Our HYPR4D kernel makes use of the spatiotemporal high frequency features extracted from a 4D composite, generated within the reconstruction, to preserve the spatiotemporal patterns and constrain the 4D noise increment of the image estimate. RESULTS: Results from simulations, experimental phantom, and patient data showed that the HYPR4D kernel with our proposed 4D composite outperformed other denoising methods, such as the standard OSEM with spatial filter, OSEM with 4D filter, and HYPR kernel method with the conventional 3D composite in conjunction with recently proposed High Temporal Resolution kernel (HYPRC3D-HTR), in terms of 4D noise reduction while preserving the spatiotemporal patterns or 4D resolution within the 4D image estimate. Consequently, the error in outcome measures obtained from the HYPR4D method was less dependent on the region size, contrast, and uniformity/functional patterns within the target structures compared to the other methods. For outcome measures that depend on spatiotemporal tracer uptake patterns such as the nondisplaceable Binding Potential (BPND ), the root mean squared error in regional mean of voxel BPND values was reduced from ~8% (OSEM with spatial or 4D filter) to ~3% using HYPRC3D-HTR and was further reduced to ~2% using our proposed HYPR4D method for relatively small target structures (~10 mm in diameter). At the voxel level, HYPR4D produced two to four times lower mean absolute error in BPND relative to HYPRC3D-HTR. CONCLUSION: As compared to conventional methods, our proposed HYPR4D method can produce more robust and accurate image features without requiring any prior information.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Algoritmos , Humanos , Aprendizado de Máquina , Imagens de Fantasmas , Reprodutibilidade dos Testes
9.
J Labelled Comp Radiopharm ; 64(1): 30-39, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33063888

RESUMO

Described here is a method for the measurement of the radio-metabolites of the positron emission tomography radiotracer [6-O-methyl-11 C]diprenorphine ([11 C]diprenorphine) using in-line solid-phase extraction (SPE) combined with radio-high-pressure liquid chromatography analysis. We believe that this method offers a reliable and reproducible approach to [11 C]diprenorphine metabolite analysis. In addition, different SPE stationary phases are assessed for their efficiency for loading, retention and elution of the parent molecule and its metabolites. Having assessed C4, phenyl and C18 stationary phase, we concluded that a C18 SPE was optimal for our method. Finally, in silico predictions of diprenorphine metabolism were compared with in vivo metabolism of [11 C]diprenorphine induced by hepatic microsomal digestion and analysed by matrix-assisted laser desorption/ionisation mass spectrometry. It was found that there was a high degree of agreement between the two methods and in particular the formation of the diprenorphine-3-glucuronide metabolite.


Assuntos
Cromatografia Líquida de Alta Pressão , Diprenorfina , Tomografia por Emissão de Pósitrons , Extração em Fase Sólida
10.
Schizophr Bull ; 47(2): 505-516, 2021 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-32910150

RESUMO

The variability in the response to antipsychotic medication in schizophrenia may reflect between-patient differences in neurobiology. Recent cross-sectional neuroimaging studies suggest that a poorer therapeutic response is associated with relatively normal striatal dopamine synthesis capacity but elevated anterior cingulate cortex (ACC) glutamate levels. We sought to test whether these measures can differentiate patients with psychosis who are antipsychotic responsive from those who are antipsychotic nonresponsive in a multicenter cross-sectional study. 1H-magnetic resonance spectroscopy (1H-MRS) was used to measure glutamate levels (Glucorr) in the ACC and in the right striatum in 92 patients across 4 sites (48 responders [R] and 44 nonresponders [NR]). In 54 patients at 2 sites (25 R and 29 NR), we additionally acquired 3,4-dihydroxy-6-[18F]fluoro-l-phenylalanine (18F-DOPA) positron emission tomography (PET) to index striatal dopamine function (Kicer, min-1). The mean ACC Glucorr was higher in the NR than the R group after adjustment for age and sex (F1,80 = 4.27; P = .04). This was associated with an area under the curve for the group discrimination of 0.59. There were no group differences in striatal dopamine function or striatal Glucorr. The results provide partial further support for a role of ACC glutamate, but not striatal dopamine synthesis, in determining the nature of the response to antipsychotic medication. The low discriminative accuracy might be improved in groups with greater clinical separation or increased in future studies that focus on the antipsychotic response at an earlier stage of the disorder and integrate other candidate predictive biomarkers. Greater harmonization of multicenter PET and 1H-MRS may also improve sensitivity.


Assuntos
Antipsicóticos/farmacologia , Corpo Estriado , Dopamina/metabolismo , Ácido Glutâmico/metabolismo , Giro do Cíngulo , Transtornos Psicóticos , Esquizofrenia , Adulto , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Estudos Transversais , Feminino , Giro do Cíngulo/diagnóstico por imagem , Giro do Cíngulo/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Espectroscopia de Prótons por Ressonância Magnética , Transtornos Psicóticos/diagnóstico por imagem , Transtornos Psicóticos/tratamento farmacológico , Transtornos Psicóticos/metabolismo , Esquizofrenia/diagnóstico por imagem , Esquizofrenia/tratamento farmacológico , Esquizofrenia/metabolismo , Adulto Jovem
11.
Nat Hum Behav ; 4(3): 317-325, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32015487

RESUMO

Understanding how people rate their confidence is critical for the characterization of a wide range of perceptual, memory, motor and cognitive processes. To enable the continued exploration of these processes, we created a large database of confidence studies spanning a broad set of paradigms, participant populations and fields of study. The data from each study are structured in a common, easy-to-use format that can be easily imported and analysed using multiple software packages. Each dataset is accompanied by an explanation regarding the nature of the collected data. At the time of publication, the Confidence Database (which is available at https://osf.io/s46pr/) contained 145 datasets with data from more than 8,700 participants and almost 4 million trials. The database will remain open for new submissions indefinitely and is expected to continue to grow. Here we show the usefulness of this large collection of datasets in four different analyses that provide precise estimations of several foundational confidence-related effects.


Assuntos
Bases de Dados Factuais/estatística & dados numéricos , Processos Mentais/fisiologia , Metacognição/fisiologia , Psicometria , Análise e Desempenho de Tarefas , Adulto , Comportamento de Escolha/fisiologia , Conjuntos de Dados como Assunto/estatística & dados numéricos , Humanos , Psicometria/instrumentação , Psicometria/estatística & dados numéricos , Tempo de Reação/fisiologia
12.
Cortex ; 125: 161-174, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31991241

RESUMO

Functional motor disorders (FMDs) are distinguished by signs that lack congruence with recognised patterns of organic disease and show inconsistency over time. Their pathophysiology is poorly understood, but there is evidence that irregularities in perceptual and cognitive processing lie at the heart of these conditions. Here, we draw on a predictive coding account of functional neurological disorders to study perceptual decision-making in three groups: 20 patients with FMDs (14 with functional movements and 6 with functional weakness), 20 with phenotypically-matched organic motor disorders, and 20 age-matched healthy controls. We examine four cognitive domains with putative roles in FMD pathogenesis: attention, expectations, sensory processing (perceptual sensitivity), and metacognition (introspective evaluation of performance). We augmented a dual-task paradigm, manipulating the visual contrast required for target detection to examine these domains in one design. With sensory input (stimulus contrast) psychometrically adjusted to staircase target detection at a fixed level for all groups, the FMD group exhibited statistically equivalent attentional, expectational and metacognitive processing to healthy controls. However, we demonstrate Bayesian evidence and a frequentist trend that FMD patients require higher visual contrast than controls to maintain the same detection sensitivity (BF10 = 8.1, pholm = .066). This was statistically equivalent to the visual contrast required by the organic group, and unlikely to be accounted for by medication use or comorbid psychopathology. The organic group showed differences in processing of attention and expectations for target detection that were not observed in either healthy controls or the functional group. The distinctive behavioural profile of FMDs may arise from abnormalities in basic sensory processing, while higher attentional, expectational and metacognitive mechanisms remain intact. Conceptualising functional neurological disorders under a predictive coding account may consolidate and refine existing pathophysiological theories about them.


Assuntos
Metacognição , Transtornos Motores , Atenção , Teorema de Bayes , Humanos , Percepção Visual
13.
Clin Cancer Res ; 25(13): 3818-3829, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31053599

RESUMO

PURPOSE: Hypoxia is associated with poor prognosis and is predictive of poor response to cancer treatments, including radiotherapy. Developing noninvasive biomarkers that both detect hypoxia prior to treatment and track change in tumor hypoxia following treatment is required urgently. EXPERIMENTAL DESIGN: We evaluated the ability of oxygen-enhanced MRI (OE-MRI) to map and quantify therapy-induced changes in tumor hypoxia by measuring oxygen-refractory signals in perfused tissue (perfused Oxy-R). Clinical first-in-human study in patients with non-small cell lung cancer (NSCLC) was performed alongside preclinical experiments in two xenograft tumors (Calu6 NSCLC model and U87 glioma model). RESULTS: MRI perfused Oxy-R tumor fraction measurement of hypoxia was validated with ex vivo tissue pathology in both xenograft models. Calu6 and U87 experiments showed that MRI perfused Oxy-R tumor volume was reduced relative to control following single fraction 10-Gy radiation and fractionated chemoradiotherapy (P < 0.001) due to both improved perfusion and reduced oxygen consumption rate. Next, evaluation of 23 patients with NSCLC showed that OE-MRI was clinically feasible and that tumor perfused Oxy-R volume is repeatable [interclass correlation coefficient: 0.961 (95% CI, 0.858-0.990); coefficient of variation: 25.880%]. Group-wise perfused Oxy-R volume was reduced at 14 days following start of radiotherapy (P = 0.015). OE-MRI detected between-subject variation in hypoxia modification in both xenograft and patient tumors. CONCLUSIONS: These findings support applying OE-MRI biomarkers to monitor hypoxia modification, to stratify patients in clinical trials of hypoxia-modifying therapies, to identify patients with hypoxic tumors that may fail treatment with immunotherapy, and to guide adaptive radiotherapy by mapping regional hypoxia.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Hipóxia/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Imageamento por Ressonância Magnética , Oxigênio/metabolismo , Animais , Biomarcadores , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Linhagem Celular Tumoral , Modelos Animais de Doenças , Humanos , Aumento da Imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Camundongos , Medicina de Precisão/métodos , Medicina de Precisão/normas , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Carga Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Otol Neurotol ; 40(6): 826-835, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31033921

RESUMO

OBJECTIVE: To investigate whether [F]fluorothymidine (FLT) and/or [F]fluorodeoxyglucose (FDG) positron emission tomography (PET) can differentiate growth in neurofibromatosis 2 (NF2) related vestibular schwannomas (VS) and to evaluate the importance of PET scanner spatial resolution on measured tumor uptake. METHODS: Six NF2 patients with 11 VS (4 rapidly growing, 7 indolent), were scanned with FLT and FDG using a high-resolution research tomograph (HRRT, Siemens) and a Siemens Biograph TrueV PET-CT, with and without resolution modeling image reconstruction. Mean, maximum, and peak standardised uptake values (SUV) for each tumor were derived and the intertumor correlation between FDG and FLT uptake was compared. The ability of FDG and FLT SUV values to discriminate between rapidly growing and slow growing (indolent) tumors was assessed using receiver operator characteristic (ROC) analysis. RESULTS: Tumor uptake was seen with both tracers, using both scanners, with and without resolution modeling. FDG and FLT uptake was correlated (R = 0.67-0.86, p < 0.01) and rapidly growing tumors displayed significantly higher uptake (SUVmean and SUVpeak) of both tracers (p < 0.05, one tailed t test). All of the PET analyses performed demonstrated better discriminatory power (AUCROC range = 0.71-0.86) than tumor size alone (AUCROC = 0.61). The use of standard resolution scanner with standard reconstruction did not result in a notable deterioration of discrimination accuracy. CONCLUSION: NF2 related VS demonstrate uptake of both FLT and FDG, which is significantly increased in rapidly growing tumors. A short static FDG PET scan with standard clinical resolution and reconstruction can provide relevant information on tumor growth to aid clinical decision making.


Assuntos
Fluordesoxiglucose F18 , Neurofibromatose 2/diagnóstico por imagem , Neuroma Acústico/diagnóstico por imagem , Adulto , Didesoxinucleosídeos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Adulto Jovem
15.
Atten Percept Psychophys ; 81(1): 188-204, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30291551

RESUMO

In visual search of natural scenes, differentiation of briefly fixated but task-irrelevant distractor items from incidental memory is often comparable to explicit memorization. However, many characteristics of incidental memory remain unclear, including the capacity for its conscious retrieval. Here, we examined incidental memory for faces in either upright or inverted orientation using Rapid Serial Visual Presentation (RSVP). Subjects were instructed to detect a target face in a sequence of 8-15 faces cropped from natural scene photographs (Experiment 1). If the target face was identified within a brief time window, the subject proceeded to an incidental memory task. Here, subjects used incidental memory to discriminate between a probe face (a distractor in the RSVP stream) and a novel, foil face. In Experiment 2 we reduced scene-related semantic coherency by intermixing faces from multiple scenes and contrasted incidental memory with explicit memory, a condition where subjects actively memorized each face from the sequence without searching for a target. In both experiments, we measured objective performance (Type 1 AUC) and metacognitive accuracy (Type 2 AUC), revealing sustained and consciously accessible incidental memory for upright and inverted faces. In novel analyses of face categories, we examined whether accuracy or metacognitive judgments are affected by shared semantic features (i.e., similarity in gender, race, age). Similarity enhanced the accuracy of incidental memory discriminations but did not influence metacognition. We conclude that incidental memory is sustained and consciously accessible, is not reliant on scene contexts, and is not enhanced by explicit memorization.


Assuntos
Estado de Consciência/fisiologia , Reconhecimento Facial/fisiologia , Memória/fisiologia , Orientação Espacial/fisiologia , Estimulação Luminosa/métodos , Adulto , Feminino , Humanos , Masculino , Semântica
16.
Phys Med Biol ; 63(24): 24NT01, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30524089

RESUMO

In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.


Assuntos
Simulação por Computador , Elétrons , Radioisótopos de Flúor/análise , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Carbono/análise , Radioisótopos de Gálio/análise , Humanos , Método de Monte Carlo , Radioisótopos de Oxigênio/análise
17.
Int J Palliat Nurs ; 24(10): 510-514, 2018 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-30354899

RESUMO

BACKGROUND:: Enhanced supportive care (ESC) promotes the earlier implementation of supportive care within cancer care. While earlier supportive care has been demonstrated to improve patient outcomes, the model of delivery is variable. The Clatterbridge Cancer Centre has developed a multi-professional delivered model with clinical nurse specialists providing ongoing patient review and care. METHOD:: A retrospective single-system design was used to assess longitudinal changes in Integrated Palliative Care Outcome Scale (IPOS) scores as indicators of quality of life. For other outcomes, a retrospective case control analysis was undertaken. RESULTS:: Statistically significant improvements in all IPOS scores were observed for patients attending ESC. Compared to controls, quantitative outcomes included prolonged survival and reduced chemotherapy-related mortality. Multi-professional delivered ESC successfully improves quality of life and outcomes.


Assuntos
Pessoal de Saúde/psicologia , Colaboração Intersetorial , Neoplasias/enfermagem , Neoplasias/psicologia , Cuidados Paliativos/psicologia , Qualidade de Vida/psicologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude do Pessoal de Saúde , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Estudos Retrospectivos
18.
Artigo em Inglês | MEDLINE | ID: mdl-30061465

RESUMO

Whether conscious perception requires attention remains a topic of intense debate. While certain complex stimuli such as faces and animals can be discriminated outside the focus of spatial attention, many simpler stimuli cannot. Because such evidence was obtained in dual-task paradigms involving no measure of subjective insight, it remains unclear whether accurate discrimination of unattended complex stimuli is the product of automatic, unconscious processing, as in blindsight, or is accessible to consciousness. Furthermore, these paradigms typically require extensive training over many hours, bringing into question whether this phenomenon can be achieved in naive subjects. We developed a novel dual-task paradigm incorporating confidence ratings to calculate metacognition and adaptive staircase procedures to reduce training. With minimal training, subjects were able to discriminate face-gender in the near absence of top-down attentional amplification, while also displaying above-chance metacognitive accuracy. By contrast, the discrimination of simple coloured discs was significantly impaired and metacognitive accuracy dropped to chance-level, even in a partial-report condition. In a final experiment, we used blended face/disc stimuli and confirmed that face-gender but not colour orientation can be discriminated in the dual task. Our results show direct evidence for metacognitive conscious access in the near absence of attention for complex, but not simple, stimuli.This article is part of the theme issue 'Perceptual consciousness and cognitive access'.


Assuntos
Atenção , Estado de Consciência , Metacognição , Percepção Visual , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
19.
Biol Psychiatry ; 83(1): 61-69, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28939116

RESUMO

BACKGROUND: Major depressive disorder is associated with raised peripheral inflammatory markers. Mounting evidence also suggests that inflammation is involved in suicidal behavior. However, the involvement of inflammation in the brains of individuals with depression, and its association with suicidal ideation, needs further clarification. Translocator protein (TSPO), which is upregulated in activated glia (predominantly microglia), can be measured as an indication of neuroinflammation in vivo using positron emission tomography and TSPO-specific radioligands. METHODS: We used [11C](R)-PK11195 positron emission tomography to compare TSPO availability in the anterior cingulate cortex (ACC), prefrontal cortex, and insula between 14 medication-free patients in a major depressive episode of at least moderate severity and 13 matched healthy control subjects. In a post hoc analysis, we also compared TSPO availability between patients with and without suicidal thoughts. RESULTS: Multivariate analysis of variance indicated significantly higher TSPO in patients compared with control subjects (p = .005). The elevation was of large effect size and significant in the ACC (p = .022, Cohen's d = 0.95), with smaller nonsignificant elevations in the prefrontal cortex (p = .342, Cohen's d = 0.38) and insula (p = .466, Cohen's d = 0.29). TSPO was not elevated in patients without suicidal thinking but was significantly increased in those with suicidal thoughts compared with those without, most robustly in the ACC (p = .008) and insula (p = .023). CONCLUSIONS: We confirm evidence for increased TSPO availability, suggestive of predominantly microglial activation, in the ACC during a moderate to severe major depressive episode. Our findings provide further incentive for evaluating anti-inflammatory therapies in major depressive disorder.


Assuntos
Transtorno Depressivo Maior/metabolismo , Transtorno Depressivo Maior/psicologia , Giro do Cíngulo/metabolismo , Inflamação/metabolismo , Receptores de GABA/metabolismo , Ideação Suicida , Adulto , Mapeamento Encefálico , Radioisótopos de Carbono , Transtorno Depressivo Maior/diagnóstico por imagem , Feminino , Giro do Cíngulo/diagnóstico por imagem , Humanos , Inflamação/diagnóstico por imagem , Inflamação/psicologia , Isoquinolinas , Masculino , Microglia/metabolismo , Análise Multivariada , Tomografia por Emissão de Pósitrons , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/metabolismo , Compostos Radiofarmacêuticos , Índice de Gravidade de Doença
20.
Magn Reson Med ; 79(4): 2236-2245, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28856728

RESUMO

PURPOSE: Previous work has shown that combining dynamic contrast-enhanced (DCE)-MRI and oxygen-enhanced (OE)-MRI binary enhancement maps can identify tumor hypoxia. The current work proposes a novel, data-driven method for mapping tissue oxygenation and perfusion heterogeneity, based on clustering DCE/OE-MRI data. METHODS: DCE-MRI and OE-MRI were performed on nine U87 (glioblastoma) and seven Calu6 (non-small cell lung cancer) murine xenograft tumors. Area under the curve and principal component analysis features were calculated and clustered separately using Gaussian mixture modelling. Evaluation metrics were calculated to determine the optimum feature set and cluster number. Outputs were quantitatively compared with a previous non data-driven approach. RESULTS: The optimum method located six robustly identifiable clusters in the data, yielding tumor region maps with spatially contiguous regions in a rim-core structure, suggesting a biological basis. Mean within-cluster enhancement curves showed physiologically distinct, intuitive kinetics of enhancement. Regions of DCE/OE-MRI enhancement mismatch were located, and voxel categorization agreed well with the previous non data-driven approach (Cohen's kappa = 0.61, proportional agreement = 0.75). CONCLUSION: The proposed method locates similar regions to the previous published method of binarization of DCE/OE-MRI enhancement, but renders a finer segmentation of intra-tumoral oxygenation and perfusion. This could aid in understanding the tumor microenvironment and its heterogeneity. Magn Reson Med 79:2236-2245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Hipóxia Tumoral , Microambiente Tumoral , Algoritmos , Animais , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Análise por Conglomerados , Glioblastoma/diagnóstico por imagem , Humanos , Hipóxia , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Camundongos , Transplante de Neoplasias , Distribuição Normal , Oxigênio/metabolismo , Perfusão , Análise de Componente Principal , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...