Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Contact Dermatitis ; 75(5): 276-284, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27538353

RESUMO

BACKGROUND: Octylisothiazolinone (OIT) is used as an antifungal agent by the leather industry. OBJECTIVES: To show sensitization to OIT from leather, and to highlight the potential implications when cross-reactivity between OIT and methylisothiazolinone (MI) is studied. METHODS: Two patients with allergic contact dermatitis caused by a leather belt and shoes, respectively, were patch tested with methylchloroisothiazolinone (MCI)/MI, MI, MCI, OIT, and benzisothiazolinone (BIT). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to detect isothiazolinone derivatives in leather goods. Additionally, files of OIT-sensitized patients, observed at the KU Leuven department during the period 1990-2015, were retrospectively analysed. RESULTS: Both patients had been primarily sensitized to OIT, but the diagnosis in one of them could be achieved only when a higher patch test concentration of OIT (1000 ppm pet.) was used. HPLC-UV confirmed the presence of OIT in their leather goods. Non-relevant sensitization to MI was noted in both cases. Four additional cases of OIT sensitization from leather could be retrieved from the KU Leuven database. CONCLUSIONS: Non-occupational sensitization to OIT from leather may occur. Patch test concentrations of >250 ppm pet. may be necessary for diagnosis, and to show cross-reactivity with MI. Safer use limits for OIT in the leather industry may be needed.


Assuntos
Dermatite Alérgica de Contato/etiologia , Dermatoses do Pé/etiologia , Fungicidas Industriais/efeitos adversos , Sapatos/efeitos adversos , Tiazóis/efeitos adversos , Abdome , Adulto , Cromatografia Líquida de Alta Pressão , Vestuário/efeitos adversos , Reações Cruzadas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Conservantes Farmacêuticos/efeitos adversos
2.
Contact Dermatitis ; 49(6): 281-3, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15025698

RESUMO

Allergic contact dermatitis caused by polyvinyl chloride gloves is rarely reported, and in only 2 cases was bisphenol A considered to be the responsible sensitizer. We report a patient with occupational hand dermatitis after the use of a new type of high-density vinyl (HDV) gloves. Patch tests showed positive (++) reactions to both used and new HDV gloves and to bisphenol A. Chemical analysis by gas chromatography-mass spectrometry demonstrated the presence of bisphenol A in the HDV gloves. Replacement by nitrile rubber gloves resulted in complete clearance of the hand dermatitis.


Assuntos
Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Ocupacional/diagnóstico , Dermatoses da Mão/diagnóstico , Fenóis/efeitos adversos , Adulto , Compostos Benzidrílicos , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/patologia , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/patologia , Diagnóstico Diferencial , Feminino , Luvas Protetoras/efeitos adversos , Dermatoses da Mão/induzido quimicamente , Dermatoses da Mão/patologia , Humanos , Testes do Emplastro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...