1.
J Thorac Oncol ; 17(4): 519-531, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34973418

RESUMO

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive, image-guided approach to access lung lesions for biopsy or localization for treatment. However, no studies have reported prospective 24-month follow-up from a large, multinational, generalizable cohort. This study evaluated ENB safety, diagnostic yield, and usage patterns in an unrestricted, real-world observational design. METHODS: The NAVIGATE single-arm, pragmatic cohort study (NCT02410837) enrolled subjects at 37 academic and community sites in seven countries with prospective 24-month follow-up. Subjects underwent ENB using the superDimension navigation system versions 6.3 to 7.1. The prespecified primary end point was procedure-related pneumothorax requiring intervention or hospitalization. RESULTS: A total of 1388 subjects were enrolled for lung lesion biopsy (1329; 95.7%), fiducial marker placement (272; 19.6%), dye marking (23; 1.7%), or lymph node biopsy (36; 2.6%). Concurrent endobronchial ultrasound-guided staging occurred in 456 subjects. General anesthesia (78.2% overall, 56.6% Europe, 81.4% United States), radial endobronchial ultrasound (50.6%, 4.0%, 57.4%), fluoroscopy (85.0%, 41.7%, 91.0%), and rapid on-site evaluation use (61.7%, 17.3%, 68.5%) differed between regions. Pneumothorax and bronchopulmonary hemorrhage occurred in 4.7% and 2.7% of subjects, respectively (3.2% [primary end point] and 1.7% requiring intervention or hospitalization). Respiratory failure occurred in 0.6%. The diagnostic yield was 67.8% (range: 61.9%-70.7%; 55.2% Europe, 69.8% United States). Sensitivity for malignancy was 62.6%. Lung cancer clinical stage was I to II in 64.7% (55.3% Europe, 65.8% United States). CONCLUSIONS: Despite a heterogeneous cohort and regional differences in procedural techniques, ENB demonstrates low complications and a 67.8% diagnostic yield while allowing biopsy, staging, fiducial placement, and dye marking in a single procedure.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Broncoscopia/métodos , Estudos de Coortes , Fenômenos Eletromagnéticos , Humanos , Pulmão/patologia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Estudos Prospectivos , Estados Unidos
2.
J Bronchology Interv Pulmonol ; 28(3): 174-183, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33369988

RESUMO

BACKGROUND: The diagnostic yield of electromagnetic navigation bronchoscopy (ENB) is impacted by biopsy tool strategy and rapid on-site evaluation (ROSE) use. This analysis evaluates usage patterns, accuracy, and safety of tool strategy and ROSE in a multicenter study. METHODS: NAVIGATE (NCT02410837) evaluates ENB using the superDimension navigation system (versions 6.3 to 7.1). The 1-year analysis included 1215 prospectively enrolled subjects at 29 United States sites. Included herein are 416 subjects who underwent ENB-aided biopsy of a single lung lesion positive for malignancy at 1 year. Use of a restricted number of tools (only biopsy forceps, standard cytology brush, and/or bronchoalveolar lavage) was compared with an extensive multimodal strategy (biopsy forceps, cytology brush, aspirating needle, triple needle cytology brush, needle-tipped cytology brush, core biopsy system, and bronchoalveolar lavage). RESULTS: Of malignant cases, 86.8% (361/416) of true positive diagnoses were obtained using extensive multimodal strategies. ROSE was used in 300/416 cases. The finding of malignancy by ROSE reduced the total number of tools used. A malignant ROSE call was obtained in 71% (212/300), most (88.7%; 188/212) by the first tool used (49.5% with aspirating needle, 20.2% with cytology brush, 17.0% with forceps). True positive rates were highest for the biopsy forceps (86.9%) and aspirating needle (86.6%). Use of extensive tool strategies did not increase the rates of pneumothorax (5.5% restricted, 2.8% extensive) or bronchopulmonary hemorrhage (3.6% restricted, 1.1% extensive). CONCLUSION: These results suggest that extensive biopsy tool strategies, including the aspirating needle, may provide higher true positive rates for detecting lung cancer without increasing complications.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Biópsia , Broncoscopia , Fenômenos Eletromagnéticos , Humanos , Neoplasias Pulmonares/diagnóstico , Estudos Prospectivos
3.
J Bronchology Interv Pulmonol ; 28(1): 10-20, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32412920

RESUMO

BACKGROUND: Electromagnetic navigation bronchoscopy (ENB) aids in lung lesion biopsy. However, anatomic divergence between the preprocedural computed tomography (CT) and the actual bronchial anatomy during the procedure can limit localization accuracy. An advanced ENB system has been designed to mitigate CT-to-body divergence using a tomosynthesis-based software algorithm that enhances nodule visibility and allows for intraprocedural local registration. MATERIALS AND METHODS: A prospective, 2-center study was conducted in subjects with single peripheral lung lesions ≥10 mm to assess localization accuracy of the superDimension navigation system with fluoroscopic navigation technology. Three-dimensional accuracy was confirmed by cone-beam computed tomography. Complications were assessed through 7 days. RESULTS: Fifty subjects were enrolled (25 per site). Lesions were <20 mm in 61.2% (30/49). A bronchus sign was present in 53.1% (26/49). Local registration was completed in 95.9% (47/49). Three-dimensional target overlap (primary endpoint) was achieved in 59.6% (28/47) and 83.0% (39/47) before and after location correction, respectively. Excluding subjects with unevaluable video files, target overlap was achieved 68.3% (28/41) and 95.1% (39/41), respectively. Malignant results were obtained in 53.1% (26/49) by rapid on-site evaluation and 61.2% (30/49) by final pathology of the ENB-aided sample. Diagnostic yield was not evaluated. Procedure-related complications were pneumothorax in 1 subject (no chest tube required) and scant hemoptysis in 3 subjects (no interventions required). CONCLUSION: ENB with tomosynthesis-based fluoroscopic navigation improved the 3-dimensional convergence between the virtual target and actual lung lesion as confirmed by cone-beam computed tomography. Future studies are necessary to understand the impact of this technology on diagnostic yield.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Tomografia Computadorizada de Feixe Cônico , Fenômenos Eletromagnéticos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Estudos Prospectivos
4.
J Thorac Oncol ; 14(3): 445-458, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30476574

RESUMO

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive technology that guides endoscopic tools to pulmonary lesions. ENB has been evaluated primarily in small, single-center studies; thus, the diagnostic yield in a generalizable setting is unknown. METHODS: NAVIGATE is a prospective, multicenter, cohort study that evaluated ENB using the superDimension navigation system (Medtronic, Minneapolis, Minnesota). In this United States cohort analysis, 1215 consecutive subjects were enrolled at 29 academic and community sites from April 2015 to August 2016. RESULTS: The median lesion size was 20.0 mm. Fluoroscopy was used in 91% of cases (lesions visible in 60%) and radial endobronchial ultrasound in 57%. The median ENB planning time was 5 minutes; the ENB-specific procedure time was 25 minutes. Among 1157 subjects undergoing ENB-guided biopsy, 94% (1092 of 1157) had navigation completed and tissue obtained. Follow-up was completed in 99% of subjects at 1 month and 80% at 12 months. The 12-month diagnostic yield was 73%. Pathology results of the ENB-aided tissue samples showed malignancy in 44% (484 of 1092). Sensitivity, specificity, positive predictive value, and negative predictive value for malignancy were 69%, 100%, 100%, and 56%, respectively. ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher pneumothoraces (requiring admission or chest tube placement) occurred in 2.9%. The ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher bronchopulmonary hemorrhage and grade 4 or higher respiratory failure rates were 1.5% and 0.7%, respectively. CONCLUSIONS: NAVIGATE shows that an ENB-aided diagnosis can be obtained in approximately three-quarters of evaluable patients across a generalizable cohort based on prospective 12-month follow-up in a pragmatic setting with a low procedural complication rate.


Assuntos
Broncoscopia/métodos , Pneumopatias/diagnóstico , Pneumotórax/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Eletromagnéticos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Adulto Jovem
5.
Crit Care ; 15(1): R60, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21320330

RESUMO

INTRODUCTION: This small observational study was motivated by our belief that scaling the tidal volume in mechanically ventilated patients to the size of the injured lung is safer and more 'physiologic' than scaling it to predicted body weight, i.e. its size before it was injured. We defined Total Lung Capacity (TLC) as the thoracic gas volume at an airway pressure of 40 cm H2O and tested if TLC could be inferred from the volume of gas that enters the lungs during a brief 'recruitment' maneuver. METHODS: Lung volume at relaxed end expiration (Vrel) as well as inspiratory capacity (IC), defined as the volume of gas that enters the lung during a 5 second inflation to 40 cm H2O, were measured in 14 patients with respiratory failure. TLC was defined as the sum of IC and Vrel. The dependence of IC and Vrel on body mass index (BMI), respiratory system elastance and plateau airway pressure was assessed. RESULTS: TLC was reduced to 59 ± 23% of that predicted. Vrel/TLC, which averaged 0.45 ± 0.11, was no different than the 0.47 ± 0.04 predicted during health in the supine posture. The greater than expected variability in observed Vrel/TLC was largely accounted for by BMI. Vrel and IC were correlated (r = 0.76). Taking BMI into account strengthened the correlation (r = 0.92). CONCLUSIONS: We conclude that body mass is a powerful determinant of lung volume and plateau airway pressure. Effective lung size can be easily estimated from a recruitment maneuver derived inspiratory capacity measurement and body mass index.


Assuntos
Índice de Massa Corporal , Lesão Pulmonar/patologia , Pulmão/patologia , Respiração Artificial/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Capacidade Pulmonar Total