Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol ; 86(2 Pt 1): 159-63, 2005 Feb.
Artigo em Francês | MEDLINE | ID: mdl-15798625

RESUMO

PURPOSE: To describe unusual rotator cuff tendon tears which are hyperechoic at ultrasonography (US). MATERIALS AND METHOD: We retrospectively reviewed the shoulder US examinations of 100 patients with rotator cuff tear demonstrated by CT arthrogram with bursography. We included in this study hyperechoic foci without surrounding hypoechoic zone. A second US examination was performed after bursal distension. RESULTS: Six (6%) hyperechoic foci were detected. The initial US diagnosis was tendinosis in five cases (n=5) and full thickness tear in one case (n=1). At repeat US examination, the hyperechoic area was completely or partially hypoechoic, probably because the tears were filled with the injected hypoechoic fluid. CONCLUSION: Some rotator cuff tears, filled with fibrinoid fragments, are probably underdiagnosed at US.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Adulto , Artrografia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Ultrassonografia
2.
Osteoarthritis Cartilage ; 10(7): 542-6, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12127834

RESUMO

UNLABELLED: The progression of joint space narrowing (JSN) is considered to be the best available marker of osteoarthritis (OA) progression. Several techniques have been proposed for the measurement of joint space at its narrowest point in OA of the hips and knees. OBJECTIVE: To evaluate the properties of the technique using an electronic caliper for the measurement of JSN in OA patients. DESIGN: We used an electronic caliper to measure joint space width (JSW) for hips on 100 plain radiographs. JSW was measured in the vertical position at the center of the femoral head. Femoral head diameter was also determined to correct for variations due to differences in magnification of digitized X-rays. All films were read twice by each of two rheumatologists (one junior, one senior) and two radiologists (one junior, one senior). Intraclass correlation coefficients and their 95% confidence intervals were calculated. RESULTS: Detailed results are given for right hips (38 with OA, 18 inflammatory, 44 normal); very similar results were obtained for left hips. For JSW, the intraclass correlation coefficient was between 0.96 and 0.99 for intraobserver reliability. The level of reliability was similar for analysis of the diameter of the femoral head (R:0.84 to 0.98) and for the ratio of these two measurements (0.96 to 0.99). The most reliable measurements were those made by the senior radiologist, followed by those made by the two rheumatologists. In assessments of interobserver reliability for the measurement of JSW, R varied from 0.91 to 0.96 for the first reading and from 0.88 to 0.96 for the second reading. For the measurement of femoral head diameter, R varied from 0.86 to 0.96 for the first reading and from 0.74 to 0.96 for the second reading. CONCLUSION: The electronic caliper technique is an accurate method for measuring JSW in the hip. This technique seems to be reproducible, is simple, and could be used for routine evaluation. Further validation is required, with the measurement of serial X-rays from the same patients.


Assuntos
Eletrônica Médica/instrumentação , Osteoartrite do Quadril/patologia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/patologia , Articulação do Quadril/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Osteoartrite do Quadril/diagnóstico por imagem , Radiografia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...