Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Musculoskelet Surg ; 102(2): 165-171, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29094321

RESUMO

BACKGROUND: Lower-limb discrepancy following total hip arthroplasty is the third-most common reason for patient dissatisfaction in orthopaedic surgery. Therefore, accurate planning and evaluation methods are mandatory. The main aim of this study was to evaluate the reliability of the EOS™ system by establishing and comparing the reproducibility of lower-limb automatic and manual 3D measurements. We hypothesized that the reproducibility of the lower-limb measurements is similar regardless of the method used and with an agreement higher than 0.95 for the length parameters. MATERIALS AND METHODS: This study utilized an EOS radiological database of 112 patients. Two independent observers performed two rounds of lower-limb measurements twice, either in manual 3D or automatic 3D mode. The intra- and inter-observer reproducibility was evaluated by the calculation of the intra-class coefficient for each measurement method. The methods were then compared. RESULTS: The intra- and inter-observer reproducibility for length measurements found with the manual and automatic 3D methods was always > 0.98. There was no significant difference in the reproducibility between the two measurement modes, with the exception of the offset, hip-knee-shaft, and neck-shaft angles. CONCLUSION: Our results indicate a very good reproducibility of EOS™ length measurement, regardless of the method used. Automated 3D mode is preferred for the collection of angular and offset measurements. Furthermore, manual mode measurements are not affected by surgical history. Level of evidence IV.


Assuntos
Antropometria/métodos , Imageamento Tridimensional/métodos , Desigualdade de Membros Inferiores/diagnóstico por imagem , Radiografia Intervencionista/métodos , Antropometria/instrumentação , Artroplastia de Quadril , Automação , Bases de Dados Factuais , Humanos , Imageamento Tridimensional/instrumentação , Desigualdade de Membros Inferiores/etiologia , Variações Dependentes do Observador , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Radiografia Intervencionista/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Bone Joint J ; 99-B(5): 632-639, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28455472

RESUMO

AIMS: It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA. PATIENTS AND METHODS: We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients). RESULTS: There was no relationship between functional outcomes, at a mean of ten years, or 15-year implant survival, and pre-operative anterior knee pain, or the presence or degree of cartilage loss documented intra-operatively at the medial patella or trochlea, or radiographic evidence of OA in the medial side of the PFJ. In 6% of cases there was full thickness cartilage loss on the lateral side of the patella. In these cases, the overall ten-year function and 15-year survival was similar to those without cartilage loss; however they had slightly more difficulty with descending stairs. Radiographic signs of OA seen in the lateral part of the PFJ were not associated with a definite compromise in functional outcome or implant survival. CONCLUSION: Severe damage to the lateral side of the PFJ with bone loss and grooving remains a contraindication to mobile-bearing UKA. Less severe damage to the lateral side of the PFJ and damage to the medial side, however severe, does not compromise the overall function or survival, so should not be considered to be a contraindication. However, if a patient does have full thickness cartilage loss on the lateral side of the PFJ they may have a slight compromise in their ability to descend stairs. Pre-operative anterior knee pain also does not compromise the functional outcome or survival and should not be considered to be a contraindication. Cite this article: Bone Joint J 2017;99-B:632-9.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho/cirurgia , Dor/etiologia , Articulação Patelofemoral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Contraindicações , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/fisiopatologia , Articulação Patelofemoral/patologia , Falha de Prótese , Radiografia , Recuperação de Função Fisiológica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...