Diagnostics (Basel) ; 13(7)2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37046543

RESUMO

A comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and DSCT at three CT dose indices (1, 5 and 10 mGy). Polyenergetic and virtual monoenergetic reconstructions were used to evaluate the performance differences by simulating a Gaussian spot with a radius of 5 mm and calculating the detectability index. The highest iterative reconstruction level was able to decrease the noise by about 70% compared with the filtered back projection using a parenchyma reconstruction kernel. The PCCT task transfer functions remained constant, while those of the DSCT increased with the reconstruction strength level. At monoenergetic 70 keV, a 50% decrease in noise was observed for DSCT with image smoothing, while PCCT had the same 50% decrease in noise without any smoothing. The PCCT detectability index at a reconstruction strength level of two was equivalent to the highest level of ADMIRE 5 for DSCT. The PCCT showed its superiority over the DSCT, especially for lung nodule detection.

2.
Phys Med Biol ; 65(15): 155012, 2020 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-32392548

RESUMO

The new Leksell Gamma knife convolution algorithm requires evaluation prior to implementation in clinical practice. The superiority of this algorithm, which takes into account tissue electron densities, was evaluated using EBT3 GafChromicTM films within an anthropomorphic phantom. The CIRS anthropomorphic head phantom was chosen for its relevance to validate the convolution algorithm. Absolute dose and dose distributions were measured and compared with the outputs calculated from the Leksell Gamma Plan algorithms (TMR10 and the convolution algorithm). The measured absolute dose and the dose distributions in the homogeneous region of the anthropomorphic phantom were clearly in agreement with the dose distribution computed by the convolution algorithm. In a heterogeneous region where soft tissues contain a medium, such as aluminium, or an air gap, the measured dose profiles drastically changed, and only the convolution algorithm was able to correctly compute the dose to water in water. The convolution algorithm was able to take into account regions with high or very low electron densities such that the measured absolute dose was nearly equal to that computed by the convolution algorithm, with a common accepted dose measurement error of 2%.


Assuntos
Algoritmos , Radiocirurgia/métodos , Alumínio , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...