1.
Radiat Prot Dosimetry ; 195(3-4): 349-354, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34144608

RESUMO

This study has sought to evaluate patient exposures during the course of particular diagnostic positron emission tomography and computed tomography (PET/CT) techniques. A total of 73 patients were examined using two types of radiopharmaceutical: 18F-fluorocholine (FCH, 48 patients) and 68Ga-prostate-specific membrane antigen (PSMA, 25 patients). The mean and range of administered activity (AA) in MBq, and effective dose (mSv) for FCH were 314.4 ± 61.6 (462.5-216.8) and 5.9 ± 1.2 (8.8-4.11), respectively. Quoted in the same set of units, the mean and range of AA and effective dose for 68Ga-PSMA were 179.3 ± 92.3 (603.1-115.1) and 17.9 ± 9.2 (60.3-11.5). Patient effective doses from 18F-FCH being a factor of two greater than the dose resulting from 68Ga-PSMA PET/CT procedures. CT accounts for some 84 and 23% for 18F-FCH and 68Ga-PSMA procedures, accordingly CT acquisition parameter optimization is recommended. Patient doses have been found to be slightly greater than previous studies.


Assuntos
Neoplasias da Próstata , Exposição à Radiação , Colina/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia