Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; : e2303288, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349615

RESUMO

Cardiovascular diseases are a leading cause of mortality and pose a significant burden on healthcare systems worldwide. Despite remarkable progress in medical research, the development of effective cardiovascular drugs has been hindered by high failure rates and escalating costs. One contributing factor is the limited availability of mature cardiomyocytes (CMs) for accurate disease modeling and drug screening. Human induced pluripotent stem cell-derived CMs offer a promising source of CMs; however, their immature phenotype presents challenges in translational applications. This review focuses on the road to achieving mature CMs by summarizing the major differences between immature and mature CMs, discussing the importance of adult-like CMs for drug discovery, highlighting the limitations of current strategies, and exploring potential solutions using electro-mechano active polymer-based scaffolds based on conductive polymers. However, critical considerations such as the trade-off between 3D systems and nutrient exchange, biocompatibility, degradation, cell adhesion, longevity, and integration into wider systems must be carefully evaluated. Continued advancements in these areas will contribute to a better understanding of cardiac diseases, improved drug discovery, and the development of personalized treatment strategies for patients with cardiovascular disorders.

2.
Microsyst Nanoeng ; 9: 85, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37408536

RESUMO

In this work, we introduce a polymer version of a previously developed silicon MEMS drop deposition tool for surface functionalization that consists of a microcantilever integrating an open fluidic channel and a reservoir. The device is fabricated by laser stereolithography, which offers the advantages of low-cost and fast prototyping. Additionally, thanks to the ability to process multiple materials, a magnetic base is incorporated into the cantilever for convenient handling and attachment to the holder of a robotized stage used for spotting. Droplets with diameters ranging from ∼50 µm to ∼300 µm are printed upon direct contact of the cantilever tip with the surface to pattern. Liquid loading is achieved by fully immersing the cantilever into a reservoir drop, where a single load results in the deposition of more than 200 droplets. The influences of the size and shape of the cantilever tip and the reservoir on the printing outcome are studied. As a proof-of-concept of the biofunctionalization capability of this 3D printed droplet dispenser, microarrays of oligonucleotides and antibodies displaying high specificity and no cross-contamination are fabricated, and droplets are deposited at the tip of an optical fiber bundle.

3.
Adv Mater ; 35(39): e2302472, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37385261

RESUMO

This study presents a novel approach to improve the performance of microelectrode arrays (MEAs) used for electrophysiological studies of neuronal networks. The integration of 3D nanowires (NWs) with MEAs increases the surface-to-volume ratio, which enables subcellular interactions and high-resolution neuronal signal recording. However, these devices suffer from high initial interface impedance and limited charge transfer capacity due to their small effective area. To overcome these limitations, the integration of conductive polymer coatings, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) is investigated as a mean of improving the charge transfer capacity and biocompatibility of MEAs. The study combines platinum silicide-based metallic 3D nanowires electrodes with electrodeposited PEDOT:PSS coatings to deposit ultra-thin (<50 nm) layers of conductive polymer onto metallic electrodes with very high selectivity. The polymer-coated electrodes were fully characterized electrochemically and morphologically to establish a direct relationship between synthesis conditions, morphology, and conductive features. Results show that PEDOT-coated electrodes exhibit thickness-dependent improved stimulation and recording performances, offering new perspectives for neuronal interfacing with optimal cell engulfment to enable the study of neuronal activity with acute spatial and signal resolution at the sub-cellular level.

4.
Biosens Bioelectron ; 227: 115182, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36870146

RESUMO

Implantable neural microelectrodes for recording and stimulating neural activity are critical for research in neuroscience and clinical neuroprosthetic applications. A current need exists for developing new technological solutions for obtaining highly selective and stealthy electrodes that provide reliable neural integration and maintain neuronal viability. This paper reports a novel Hollow Ring-like type electrode to sense and/or stimulate neural activity from three-dimensional neural networks. Due to its unique design, the ring electrode architecture enables easy and reliable access of the electrode to three-dimensional neural networks with reduced mechanical contact on the biological tissue, while providing improved electrical interface with cells. The Hollow Ring electrodes, particularly when coated with the conducting polymer poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), show improved electrical properties with extremely low impedance (7 MΩ µm2) and high charge injection capabilities (15 mC/cm2), when compared to traditional planar disk-type electrodes. The ring design also serves as an optimal architecture for cell growth to create an optimal subcellular electrical-neural interface. In addition, we showed that neural signals recorded by the ring electrode were better resolved than recordings from a traditional disk-type electrode improving the signal-to-noise ratio (SNR) and the burst detection from 3D neuronal networks in vitro. Overall, our results suggest the great potential of the hollow ring design for developing next-generation microelectrodes for applications in neural interfaces used in physiological studies and neuromodulation applications.


Assuntos
Técnicas Biossensoriais , Eletrodos Implantados , Microeletrodos , Neurônios/fisiologia , Polímeros , Compostos Bicíclicos Heterocíclicos com Pontes
5.
Microsyst Nanoeng ; 8: 21, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35251687

RESUMO

Flexible intracerebral probes for neural recording and electrical stimulation have been the focus of many research works to achieve better compliance with the surrounding tissue while minimizing rejection. Strategies have been explored to find the best way to insert flexible probes into the brain while maintaining their flexibility once positioned. Here, we present a novel and versatile scalable batch fabrication approach to deliver ultrathin and flexible probes consisting of a silk-parylene bilayer. The biodegradable silk layer, whose degradation time is programmable, provides a temporary and programmable stiffener to allow the insertion of ultrathin parylene-based flexible devices. Our innovative and robust batch fabrication technology allows complete freedom over probe design in terms of materials, size, shape, and thickness. We demonstrate successful ex vivo insertion of the probe with acute high-fidelity recordings of epileptic seizures in field potentials as well as single-unit action potentials in mouse brain slices. Our novel technological solution for implanting ultraflexible devices in the brain while minimizing rejection risks shows high potential for use in both brain research and clinical therapies.

6.
Front Bioeng Biotechnol ; 9: 780197, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34900968

RESUMO

In this study, we report a flexible implantable 4-channel microelectrode probe coated with highly porous and robust nanocomposite of poly (3,4-ethylenedioxythiophene) (PEDOT) and carbon nanofiber (CNF) as a solid doping template for high-performance in vivo neuronal recording and stimulation. A simple yet well-controlled deposition strategy was developed via in situ electrochemical polymerization technique to create a porous network of PEDOT and CNFs on a flexible 4-channel gold microelectrode probe. Different morphological and electrochemical characterizations showed that they exhibit remarkable and superior electrochemical properties, yielding microelectrodes combining high surface area, low impedance (16.8 ± 2 MΩ µm2 at 1 kHz) and elevated charge injection capabilities (7.6 ± 1.3 mC/cm2) that exceed those of pure and composite PEDOT layers. In addition, the PEDOT-CNF composite electrode exhibited extended biphasic charge cycle endurance and excellent performance under accelerated lifetime testing, resulting in a negligible physical delamination and/or degradation for long periods of electrical stimulation. In vitro testing on mouse brain slices showed that they can record spontaneous oscillatory field potentials as well as single-unit action potentials and allow to safely deliver electrical stimulation for evoking field potentials. The combined superior electrical properties, durability and 3D microstructure topology of the PEDOT-CNF composite electrodes demonstrate outstanding potential for developing future neural surface interfacing applications.

7.
MethodsX ; 7: 101106, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33145183

RESUMO

This present method describes a versatile approach for the electrochemical synthesis of a composite material of Poly (3,4-ethylenedioxythiophene) (PEDOT) and Carbon Nanofibers (CNFs) for neural interfaces and biosensing applications. Oxidized CNFs were utilized as dopants of PEDOT to prepare the composite coating through electrochemical deposition on microelectrodes arrays (MEA). The experimental results of this study showed that PEDOT:CNF microelectrodes exhibit remarkable electrochemical properties, combining low impedance, high surface area, high charge injection capability and reliable neurotransmitters monitoring using amperometric techniques. Taken together, these results suggest the great potential of PEDOT:CNF composite for developing next-generation multifunctional microelectrodes for applications in neural therapies.•A simple approach for the electrochemical synthesis of PEDOT:CNF composite material on microelectrodes for neural interfaces and neurochemical sensing.•PEDOT:CNF microelectrodes exhibit remarkable electrochemical properties, combining low impedance and high charge injection capabilities.•PEDOT:CNF microelectrodes allowed the reliable detection of neurotransmitters with improved sensitivity.

8.
Biosens Bioelectron ; 165: 112413, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729532

RESUMO

A clear need exists for novel nanostructured materials that are capable to meet the performance criteria of a number of neuronal therapies including neural recording, stimulation and sensing of bioactive molecules at the electrode-tissue interface. By combining Poly (3,4-ethylenedioxythiophene) (PEDOT), with Carbon Nanofibers (CNFs), we demonstrate a versatile approach for the synthesis of a novel composite material PEDOT:CNF with remarkable electrochemical properties, combining low impedance, high surface area, high charge injection capability and reliable neurotransmitters monitoring using amperometric techniques. The oxidized CNFs were utilized as dopants of PEDOT to prepare the composite coatings through electrochemical deposition on neural microelectrodes arrays (MEA). The PEDOT:CNF modified microelectrodes demonstrated the low specific impedance of 1.28 MΩ µm2 at 1 kHz and results in unrivalled charge injection limit of 10.03 mC/cm2 when compared to other reported organic electrode nanomaterials. Furthermore, amperometric detection performances were determined for the neurotransmitters dopamine and serotonin, exhibiting linear concentration range from 0.1 to 9 µM and from 0.06 to 9 µM respectively, high sensitivities (44.54 pA/nM.µm2 and 71.08 pA/nM.µm2, respectively) and low detection limits (0.045 µM and 0.056 µM, respectively). Cell viability was investigated on PEDOT:CNF coated microelectrodes to show that the composite material does not advocate any cytotoxicity. Taken together, these results suggest the great potential of PEDOT:CNF composite for developing next-generation multifunctional microelectrodes for applications in neural therapies.


Assuntos
Técnicas Biossensoriais , Nanofibras , Compostos Bicíclicos Heterocíclicos com Pontes , Carbono , Microeletrodos , Polímeros
9.
J Neurosci Methods ; 341: 108759, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32389603

RESUMO

BACKGROUND: Recordings with tetrodes have proven to be more effective in isolating single neuron spiking activity than with single microwires. However, tetrodes have never been used in humans. We report on the characteristics, safety, compatibility with clinical intracranial recordings in epileptic patients, and performance, of a new type of hybrid electrode equipped with tetrodes. NEW METHOD: 240 standard clinical macroelectrodes and 102 hybrid electrodes were implanted in 28 patients. Hybrids (diameter 800 µm) are made of 6 or 9 macro-contacts and 2 or 3 tetrodes (diameter 70-80 µm). RESULTS: No clinical complication or adverse event was associated with the hybrids. Impedance and noise of recordings were stable over time. The design enabled multiscale spatial analyses that revealed physiopathological events which were sometimes specific to one tetrode, but could not be recorded on the macro-contacts. After spike sorting, the single-unit yield was similar to other hybrid electrodes and was sometimes as high as >10 neurons per tetrode. COMPARISON WITH EXISTING METHOD(S): This new hybrid electrode has a smaller diameter than other available hybrid electrodes. It provides novel spatial information due to the configuration of the tetrodes. The single-unit yield appears promising. CONCLUSIONS: This new hybrid electrode is safe, easy to use, and works satisfactorily for conducting multi-scale seizure and physiological analyses.


Assuntos
Epilepsia , Neurônios , Potenciais de Ação , Eletrodos , Eletrodos Implantados , Humanos , Convulsões
10.
Sensors (Basel) ; 20(2)2020 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-31963277

RESUMO

The development of sensitive methods for in situ detection of biomarkers is a real challenge to bring medical diagnosis a step forward. The proof-of-concept of a remote multiplexed biomolecular interaction detection through a plasmonic optical fiber bundle is demonstrated here. The strategy relies on a fiber optic biosensor designed from a 300 µm diameter bundle composed of 6000 individual optical fibers. When appropriately etched and metallized, each optical fiber exhibits specific plasmonic properties. The surface plasmon resonance phenomenon occurring at the surface of each fiber enables to measure biomolecular interactions, through the changes of the retro-reflected light intensity due to light/plasmon coupling variations. The functionalization of the microstructured bundle by multiple protein probes was performed using new polymeric 3D-printed microcantilevers. Such soft cantilevers allow for immobilizing the probes in micro spots, without damaging the optical microstructures nor the gold layer. We show here the potential of this device to perform the multiplexed detection of two different antibodies with limits of detection down to a few tenths of nanomoles per liter. This tool, adapted for multiparametric, real-time, and label free monitoring is minimally invasive and could then provide a useful platform for in vivo targeted molecular analysis.


Assuntos
Técnicas Biossensoriais/métodos , Fibras Ópticas , Ressonância de Plasmônio de Superfície/métodos , Animais , Anticorpos/análise , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Ouro/química , Limite de Detecção , Ratos , Ressonância de Plasmônio de Superfície/instrumentação , Propriedades de Superfície
11.
Anal Chem ; 91(14): 8900-8907, 2019 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-31241899

RESUMO

Bipolar electrochemistry (BPE) is a powerful method based on the wireless polarization of a conductive object that induces the asymmetric electroactivity at its two extremities. A key physical limitation of BPE is the size of the conductive object because the shorter the object, the larger is the potential necessary for sufficient polarization. Micrometric and nanometric objects are thus extremely difficult to address by BPE due to the very high potentials required, in the order of tens of kV or more. Herein, the synergetic actions of BPE and of planar micropores integrated in a microfluidic device lead to the spatial confinement of the potential drop at the level of the solid-state micropore, and thus to a locally enhanced polarization of a bipolar electrode. Electrochemiluminescence (ECL) is emitted in half of the electroactive micropore and reveals the asymmetric polarization in this spatial restriction. Micrometric deoxidized silicon electrodes located in the micropore are polarized at a very low potential (7 V), which is more than 2 orders of magnitude lower compared to the classic bipolar configurations. This behavior is intrinsically associated with the unique properties of the micropores, where the sharp potential drop is focused. The presented approach offers exciting perspectives for BPE of micro/nano-objects, such as dynamic BPE with objects passing through the pores or wireless ECL-emitting micropores.

12.
ACS Appl Mater Interfaces ; 10(17): 14978-14985, 2018 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-29557639

RESUMO

There is a need for soft actuators in various biomedical applications to manipulate delicate objects such as cells and tissues. Soft actuators are able to adapt to any shape and limit the stress applied to delicate objects. Conjugated polymer (CP) actuators, especially in the so-called trilayer configuration, are interesting candidates for driving such micromanipulators. However, challenges involved in patterning the electrodes in a trilayer with individual contact have prevented further development of soft micromanipulators based on CP actuators. To allow such patterning, two printing-based patterning techniques have been developed. First, an oxidant layer is printed using either syringe-based printing or microcontact printing, followed by vapor-phase polymerization of the CP. Submillimeter patterns with electronic conductivities of 800 S·cm-1 are obtained. Next, laser ablation is used to cleanly cut the final device structures including the printed patterns, resulting in fingers with individually controllable digits and miniaturized hands. The methods presented in this paper will enable integration of patterned electrically active CP layers in many types of complex three-dimensional structures.

13.
Sci Adv ; 3(1): e1600327, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28138542

RESUMO

A need exists for artificial muscles that are silent, soft, and compliant, with performance characteristics similar to those of skeletal muscle, enabling natural interaction of assistive devices with humans. By combining one of humankind's oldest technologies, textile processing, with electroactive polymers, we demonstrate here the feasibility of wearable, soft artificial muscles made by weaving and knitting, with tunable force and strain. These textile actuators were produced from cellulose yarns assembled into fabrics and coated with conducting polymers using a metal-free deposition. To increase the output force, we assembled yarns in parallel by weaving. The force scaled linearly with the number of yarns in the woven fabric. To amplify the strain, we knitted a stretchable fabric, exhibiting a 53-fold increase in strain. In addition, the textile construction added mechanical stability to the actuators. Textile processing permits scalable and rational production of wearable artificial muscles, and enables novel ways to design assistive devices.


Assuntos
Órgãos Artificiais , Músculo Esquelético , Robótica , Humanos
14.
Adv Mater ; 28(45): 9956-9960, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27670834

RESUMO

A flexible electronic paper in full color is realized by plasmonic metasurfaces with conjugated polymers. An ultrathin large-area electrochromic material is presented which provides high polarization-independent reflection, strong contrast, fast response time, and long-term stability. This technology opens up for new electronic readers and posters with ultralow power consumption.

15.
ACS Appl Mater Interfaces ; 8(3): 1559-64, 2016 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-26709595

RESUMO

Recent progress in the field of microsystems on flexible substrates raises the need for alternatives to the stiffness of classical actuation technologies. This paper reports a top-down process to microfabricate soft conducting polymer actuators on substrates on which they ultimately operate. The bending microactuators were fabricated by sequentially stacking layers using a layer polymerization by layer polymerization of conducting polymer electrodes and a solid polymer electrolyte. Standalone microbeams thinner than 10 µm were fabricated on SU-8 substrates associated with a bottom gold electrical contact. The operation of microactuators was demonstrated in air and at low voltage (±4 V).


Assuntos
Microtecnologia/métodos , Polímeros/síntese química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Condutividade Elétrica , Polietilenoglicóis/química , Polimerização , Polímeros/química , Silício/química
16.
Sci Rep ; 4: 6913, 2014 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-25372857

RESUMO

A large-scale effort was carried out to test the performance of seven types of ionic electroactive polymer (IEAP) actuators in space-hazardous environmental factors in laboratory conditions. The results substantiate that the IEAP materials are tolerant to long-term freezing and vacuum environments as well as ionizing Gamma-, X-ray, and UV radiation at the levels corresponding to low Earth orbit (LEO) conditions. The main aim of this material behaviour investigation is to understand and predict device service time for prolonged exposure to space environment.


Assuntos
Órgãos Artificiais , Eletrólitos/química , Polímeros/química , Simulação de Ambiente Espacial/instrumentação , Radiação Cósmica , Planeta Terra , Técnicas Eletroquímicas , Eletrólitos/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Meio Ambiente Extraterreno , Congelamento , Raios gama , Humanos , Teste de Materiais , Músculos/fisiologia , Polímeros/efeitos da radiação , Voo Espacial , Raios Ultravioleta , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...