Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Pediatr ; 183(7): 3053-3062, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38656383

RESUMO

Poor growth and nutrition management in the neonatal period can have a negative impact upon both the short- and long-term outcomes for the infant. Improvements in bioelectrical impedance technology and accompanying licencing agreements now make this enhanced device available for use in infants as small as 23 weeks gestational age. An exploration of this technology and its use is now timely. The aim of the scoping review was to answer the following question: in preterm and sick term infants in the neonatal intensive care unit, how is bioelectrical impedance being utilized, in what situations, and when? The scoping review was conducted using Arksey and O'Malley's (Int J Soc Res Methodol 8(1):19-32, 2005) framework. Forty-nine papers were initially identified and 16 were included in the scoping review. Three studies were experimental designs, and 13 were observational studies. The review found that BIA was used in neonatal intensive care in three main ways, for, (1) fluid status evaluation, (2) as a measure of adequate nutrition and growth, (3) to validate the technology as an outcome measure in neonates. CONCLUSION: There is a paucity of recent robust research papers which investigate the use of bioelectrical impedance in preterm neonates. Available evidence spans a range of 30 years, with technological advancement reducing the application of older studies to the modern neonatal setting. Although this technology may be helpful for decision-making around fluid management and nutrition, in preterm infants, robust evidence is needed to demonstrate the clinical benefit of bioelectrical impedance beyond that of usual care. WHAT IS KNOWN: • Clinical decisions regarding neonatal nutrition and fluid management are currently based upon the interpretation of vital signs, fluid balance, weight trend, biochemical markers, and physical examination. • Bioelectrical Impedance Analysis (BIA) is a non-invasive method of assessing body composition which is now available to be used in infants as small as 23 weeks gestation. WHAT IS NEW: • Bioelectrical Impedance has been used in three main ways in the NICU, for fluid status evaluation, for measuring nutrition and growth and to validate BIA as an outcome. • There is a lack of recent robust research data to support the use of the device within clinical decision making in neonatal intensive care.


Assuntos
Impedância Elétrica , Recém-Nascido Prematuro , Terapia Intensiva Neonatal , Humanos , Recém-Nascido , Terapia Intensiva Neonatal/métodos , Unidades de Terapia Intensiva Neonatal , Composição Corporal
3.
J Vasc Interv Radiol ; 7(6): 825-35, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8951749

RESUMO

PURPOSE: The authors report on the use of Palmaz balloon-expandable intraluminal metallic stents to supplement conventional balloon angioplasty and to primarily treat a variety of supra-aortic arterial atherosclerotic lesions manifested by claudication or embolic phenomena. PATIENTS AND METHODS: Results from a series of seven patients are reported. Five patients received stents following percutaneous balloon angioplasty (PTA): four patients received five stents for suboptimal initial result of PTA and one patient received one stent for early restenosis following successful PTA. Two patients received three stents primarily: one patient had one stent placed for a highly eccentric innominate lesion and the other patient had two stents placed for an ulcerated nonocclusive subclavian lesion causing blue digits. RESULTS: Treatment produced immediate angiographic or hemodynamic improvement in all seven patients. Clinical follow-up was obtained on all patients (mean, 10 months; range, 3-18 months). One patient had an episode of vertigo after PTA of a right subclavian lesion that resolved after thrombolytic therapy and stent placement. CONCLUSION: The placement of metallic stents in supra-aortic arteries represented an effective adjunct to PTA of atherosclerotic stenoses in these vessels. Primary stent placement may be an effective treatment for selected lesions.


Assuntos
Arteriosclerose/terapia , Tronco Braquiocefálico , Estenose das Carótidas/terapia , Stents , Artéria Subclávia , Síndrome do Roubo Subclávio/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão , Arteriosclerose/diagnóstico por imagem , Artéria Carótida Primitiva , Estenose das Carótidas/diagnóstico por imagem , Cateterismo , Terapia Combinada , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Recidiva , Síndrome do Roubo Subclávio/diagnóstico por imagem , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA