Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Phys Lett ; 119(4)2021.
Artigo em Inglês | MEDLINE | ID: mdl-36873257

RESUMO

Cryogenic operation of complementary metal oxide semiconductor (CMOS) silicon transistors is crucial for quantum information science, but it brings deviations from standard transistor operation. Here, we report on sharp current jumps and stable hysteretic loops in the drain current as a function of gate voltage V G for both n- and p-type commercial-foundry 180-nm-process CMOS transistors when operated at voltages exceeding 1.3 V at cryogenic temperatures. The physical mechanism responsible for the device bistability is impact ionization charging of the transistor body, which leads to effective back-gating of the inversion channel. This mechanism is verified by independent measurements of the body potential. The hysteretic loops, which have a >107 ratio of high to low drain current states at the same V G, can be used for a compact capacitorless single-transistor memory at cryogenic temperatures with long retention times.

2.
J Appl Phys ; 1252019.
Artigo em Inglês | MEDLINE | ID: mdl-31097840

RESUMO

Ion sources based on laser cooling have recently provided new pathways to high-resolution microscopy, ion milling, and ion implantation. Here, we present the design and detailed characterization of a 7Li magneto-optical trap ion source (MOTIS) with a peak brightness of (1.2 ± 0.2) × 105 A m-2 sr-1 eV-1 and a maximum continuous current over 1 nA. These values significantly surpass previous Li MOTIS performance benchmarks. Using simple models, we discuss how the performance of this system relates to fundamental operating limits. This source will support a range of projects using lithium ion beams for surface microscopy and nanostructure characterization, including Li+ implantation for studies of ionic transport in energy storage materials.

3.
Nano Futures ; 1(1): 015005, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28890941

RESUMO

We present measurements of focal spot size and brightness in a focused ion beam system utilizing a laser-cooled atomic beam source of Cs ions. Spot sizes as small as (2.1 ± 0.2) nm (one standard deviation) and reduced brightness values as high as (2.4 ± 0.1) × 107 A m-2 Sr-1 eV-1 are observed with a 10 keV beam. This measured brightness is over 24 times higher than the highest brightness observed in a Ga liquid metal ion source. The behavior of brightness as a function of beam current and the dependence of effective source temperature on ionization energy are examined. The performance is seen to be consistent with earlier predictions. Demonstration of this source with very high brightness, producing a heavy ionic species such as Cs+, promises to allow significant improvements in resolution and throughput for such applications as next-generation circuit edit and nanoscale secondary ion mass spectrometry.

4.
Appl Phys Rev ; 3(1)2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27239245

RESUMO

Nanoscale focused ion beams (FIBs) represent one of the most useful tools in nanotechnology, enabling nanofabrication via milling and gas-assisted deposition, microscopy and microanalysis, and selective, spatially resolved doping of materials. Recently, a new type of FIB source has emerged, which uses ionization of laser cooled neutral atoms to produce the ion beam. The extremely cold temperatures attainable with laser cooling (in the range of 100 µK or below) result in a beam of ions with a very small transverse velocity distribution. This corresponds to a source with extremely high brightness that rivals or may even exceed the brightness of the industry standard Ga+ liquid metal ion source. In this review we discuss the context of ion beam technology in which these new ion sources can play a role, their principles of operation, and some examples of recent demonstrations. The field is relatively new, so only a few applications have been demonstrated, most notably low energy ion microscopy with Li ions. Nevertheless, a number of promising new approaches have been proposed and/or demonstrated, suggesting that a rapid evolution of this type of source is likely in the near future.

5.
Phys Rev Lett ; 96(14): 143005, 2006 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-16712071

RESUMO

We report on a novel mechanism that allows for strong laser cooling of atoms that do not have a closed cycling transition. This mechanism is observed in a magneto-optical trap (MOT) for erbium, an atom with a very complex energy level structure with multiple pathways for optical-pumping losses. We observe surprisingly high trap populations of over 10(6) atoms and densities of over 10(11) atoms cm(-3), despite the many potential loss channels. A model based on recycling of metastable and ground state atoms held in the quadrupole magnetic field of the trap explains the high trap population, and agrees well with time-dependent measurements of MOT fluorescence. The demonstration of trapping of a rare-earth atom such as erbium opens a wide range of new possibilities for practical applications and fundamental studies with cold atoms.

6.
Science ; 269(5228): 1255-7, 1995 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-7652572

RESUMO

Lithography can be performed with beams of neutral atoms in metastable excited states to pattern self-assembled monolayers (SAMs) of alkanethiolates on gold. An estimated exposure of a SAM of dodecanethiolate (DDT) to 15 to 20 metastable argon atoms per DDT molecule damaged the SAM sufficiently to allow penetration of an aqueous solution of ferricyanide to the surface of the gold. This solution etched the gold and transformed the patterns in the SAMs into structures of gold; these structures had edge resolution of less than 100 nanometers. Regions of SAMs as large as 2 square centimeters were patterned by exposure to a beam of metastable argon atoms. These observations suggest that this system may be useful in new forms of micro- and nanolithography.


Assuntos
Físico-Química , Ouro , Compostos de Sulfidrila , Propriedades de Superfície , Argônio , Fenômenos Químicos , Ferricianetos , Microscopia Eletrônica/instrumentação
7.
Science ; 262(5135): 877-80, 1993 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-17757354

RESUMO

The ability to fabricate nanometer-sized structures that are stable in air has the potential to contribute significantly to the advancement of new nanotechnologies and our understanding of nanoscale systems. Laser light can be used to control the motion of atoms on a nanoscopic scale. Chromium atoms were focused by a standing-wave laser field as they deposited onto a silicon substrate. The resulting nanostructure consisted of a series of narrow lines covering 0.4 millimeter by 1 millimeter. Atomic force microscopy measurements showed a line width of 65 +/- 6 nanometers, a spacing of 212.78 nanometers, and a height of 34 +/-+ 10 nanometers. The observed line widths and shapes are compared with the predictions of a semiclassical atom optical model.

9.
J Rheumatol ; 7(2): 248-50, 1980.
Artigo em Inglês | MEDLINE | ID: mdl-7373629

RESUMO

An attempt to obtain a synovial biopsy with a previously unused Parker-Pearson needle resulted in intraarticular fragmentation of the tip of the biopsy needle. Since gross inspection of the needle carried out before the procedure did not show any abnormalities, we believe that the manufacturer's material might be defective and that the inner part of this instrument must be made stronger to avoid this complication.


Assuntos
Biópsia por Agulha/efeitos adversos , Cartilagem Articular/lesões , Membrana Sinovial/patologia , Artrite Reumatoide/patologia , Biópsia por Agulha/métodos , Humanos , Traumatismos do Joelho , Masculino , Pessoa de Meia-Idade , Membrana Sinovial/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...