Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Curr Cardiol Rev ; 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34886777

RESUMO

Since the authors are not responding to the editor's requests to fulfill the editorial requirement, therefore, the article has been withdrawn by the publisher.Bentham Science apologizes to the readers of the journal for any inconvenience this may have caused.The Bentham Editorial Policy on Article Withdrawal can be found at https://benthamscience.com/editorial-policies-main.php. Bentham Science Disclaimer: It is a condition of publication that manuscripts submitted to this journal have not been published and will not be simultaneously submitted or published elsewhere. Furthermore, any data, illustration, structure or table that has been published elsewhere must be reported, and copyright permission for reproduction must be obtained. Plagiarism is strictly forbidden, and by submitting the article for publication the authors agree that the publishers have the legal right to take appropriate action against the authors, if plagiarism or fabricated information is discovered. By submitting a manuscript the authors agree that the copyright of their article is transferred to the publishers if and when the article is accepted for publication.

2.
J Arrhythm ; 37(4): 922-930, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34386118

RESUMO

BACKGROUND: Atrial fibrillation (AF) is characterized by the repetitive regeneration of unstable rotational events, the pivot of which are known as phase singularities (PSs). The spatial concentration and distribution of PSs have not been systematically investigated using quantitative statistical approaches. OBJECTIVES: We utilized a geospatial statistical approach to determine the presence of local spatial concentration and global clustering of PSs in biatrial human AF recordings. METHODS: 64-electrode conventional basket (~5 min, n = 18 patients, persistent AF) recordings were studied. Phase maps were produced using a Hilbert-transform based approach. PSs were characterized spatially using the following approaches: (i) local "hotspots" of high phase singularity (PS) concentration using Getis-Ord Gi* (Z ≥ 1.96, P ≤ .05) and (ii) global spatial clustering using Moran's I (inverse distance matrix). RESULTS: Episodes of AF were analyzed from basket catheter recordings (H: 41 epochs, 120 000 s, n = 18 patients). The Getis-Ord Gi* statistic showed local PS hotspots in 12/41 basket recordings. As a metric of spatial clustering, Moran's I showed an overall mean of 0.033 (95% CI: 0.0003-0.065), consistent with the notion of complete spatial randomness. CONCLUSION: Using a systematic, quantitative geospatial statistical approach, evidence for the existence of spatial concentrations ("hotspots") of PSs were detectable in human AF, along with evidence of spatial clustering. Geospatial statistical approaches offer a new approach to map and ablate PS clusters using substrate-based approaches.

3.
J Cardiovasc Electrophysiol ; 32(4): 1147-1160, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33682258

RESUMO

Atrial fibrillation (AF) is the most commonly encountered cardiac arrhythmia in clinical practice. However, current therapeutic interventions for atrial fibrillation have limited clinical efficacy as a consequence of major knowledge gaps in the mechanisms sustaining atrial fibrillation. From a mechanistic perspective, there is increasing evidence that atrial fibrosis plays a central role in the maintenance and perpetuation of atrial fibrillation. Electrophysiologically, atrial fibrosis results in alterations in conduction velocity, cellular refractoriness, and produces conduction block promoting meandering, unstable wavelets and micro-reentrant circuits. Clinically, atrial fibrosis has also linked to poor clinical outcomes including AF-related thromboembolic complications and arrhythmia recurrences post catheter ablation. In this article, we review the pathophysiology behind the formation of fibrosis as AF progresses, the role of fibrosis in arrhythmogenesis, surrogate markers for detection of fibrosis using cardiac magnetic resonance imaging, echocardiography and electroanatomic mapping, along with their respective limitations. We then proceed to review the current evidence behind therapeutic interventions targeting atrial fibrosis, including drugs and substrate-based catheter ablation therapies followed by the potential future use of electro phenotyping for AF characterization to overcome the limitations of contemporary substrate-based methodologies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/patologia , Fibrilação Atrial/terapia , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Resultado do Tratamento
4.
Europace ; 23(5): 665-673, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-33351904

RESUMO

Atrial fibrillation (AF) is an established independent risk factor for stroke. Current guidelines regard AF as binary; either present or absent, with the decision for anti-coagulation driven by clinical variables alone. However, there are increasing data to support a biological gradient of AF burden and stroke risk, both in clinical and non-clinical AF phenotypes. As such, this raises the concept of combining AF burden assessment with a clinical risk score to refine and individualize the assessment of stroke risk in AF-the CHA2DS2VASc-AFBurden score. We review the published data supporting a biological gradient to try and construct a putative schema of risk attributable to AF burden.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Humanos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
5.
J Arrhythm ; 36(4): 660-667, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32782637

RESUMO

BACKGROUND: Unstable functional reentrant circuits known as rotors have been consistently observed in atrial fibrillation and are mechanistically believed critical to the maintenance of the arrhythmia. Recently, using a Poisson renewal theory-based quantitative framework, we have demonstrated that rotor formation (λf) and destruction rates (λd) can be measured using in vivo electrophysiologic data. However, the association of λf and λd with clinical, electrical, and structural markers of atrial fibrillation phenotype is unknown. METHODS: RENEWAL-AF is a multicenter prospective cross-sectional study recruiting adult patients with paroxysmal or persistent atrial fibrillation undergoing clinically indicated catheter ablation. Patients will undergo intraprocedural electrophysiologic atrial fibrillation mapping, with λf and λd to be determined from 2-minute unipolar electrogram recordings acquired before ablation. The primary objective will be to determine the association of λf and λd as markers of fibrillatory dynamics with clinical, electrical, and structural markers of atrial fibrillation clinical phenotype, measured by preablation transthoracic echocardiogram and cardiac magnetic resonance imaging. An exploratory objective is the noninvasive assessment of λf and λd using surface ECG characteristics via a machine learning approach. RESULTS: Not applicable. CONCLUSION: This pilot study will provide insight into the correlation between λf/λd with clinical, electrophysiological, and structural markers of atrial fibrillation phenotype and provide a foundation for the development of noninvasive assessment of λf/λd using surface ECG characteristics will help expand the use of λf/λd in clinical practice.

6.
JMIR Mhealth Uhealth ; 8(7): e15576, 2020 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-32706685

RESUMO

BACKGROUND: Wearable trackers are an increasingly popular tool among healthy adults and are used to facilitate self-monitoring of physical activity. OBJECTIVE: We aimed to systematically review the effectiveness of wearable trackers for improving physical activity and weight reduction among healthy adults. METHODS: This review used the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methodology and reporting criteria. English-language randomized controlled trials with more than 20 participants from MEDLINE, CINAHL, Cochrane Library, Web of Science, PubMed, and Scopus (2000-2017) were identified. Studies were eligible for inclusion if they reported an intervention group using wearable trackers, reporting steps per day, total moderate-to-vigorous physical activity, activity, physical activity, energy expenditure, and weight reduction. RESULTS: Twelve eligible studies with a total of 1693 participants met the inclusion criteria. The weighted average age was 40.7 years (95% CI 31.1-50.3), with 64.4% women. The mean intervention duration was 21.4 weeks (95% CI 6.1-36.7). The usage of wearable trackers was associated with increased physical activity (standardized mean difference 0.449, 95% CI 0.10-0.80; P=.01). In the subgroup analyses, however, wearable trackers demonstrated no clear benefit for physical activity or weight reduction. CONCLUSIONS: These data suggest that the use of wearable trackers in healthy adults may be associated with modest short-term increases in physical activity. Further data are required to determine if a sustained benefit is associated with wearable tracker usage.


Assuntos
Exercício Físico , Monitores de Aptidão Física , Nível de Saúde , Adulto , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Redução de Peso
7.
J Cardiovasc Electrophysiol ; 31(9): 2288-2297, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32583514

RESUMO

BACKGROUND: Multipolar catheters provide high-density mapping which may reduce the procedural duration and improve the success of catheter ablation (CA) for focal arrhythmias. The high-density grid (HDG) catheter is a 16 electrode mapping catheter with bipole recordings at orthogonal splines. The aim of this study is to compare the clinical and procedural features from a cohort who underwent CA for focal arrhythmias using multipolar mapping (MPM) with age and case-matched cohort using point-by-point (PbyP) mapping. METHODS: Consecutive patients undergoing CA for focal arrhythmias between October 2018 and January 2020 guided by MPM were compared with PbyP mapping with the ablation catheter over a similar period. Demographics, procedural features, and outcomes were compared. RESULTS: A total of 54 patients (27 in MPM vs. 27 in PbyP mapping) underwent CA for 68 focal arrhythmias (26 atrial and 42 ventricular). In the MPM group, the electrogram at the successful site was significantly earlier (39 ± 11 ms) than in the PbyP group (33 ± 7 ms; p = .02). In the MPM group, the mapping time (35 ± 24 vs. 53 ± 31 min in PbyP; p = .03) and procedural duration (126 ± 42 vs. 153 ± 39 min in PbyP; p = .02) were significantly shorter. There was no significant difference in radiofrequency and fluoroscopy times, acute procedural success, and arrhythmia recurrence. CONCLUSION: MPM with the HDG catheter for focal tachycardias identified earlier activation times and was associated with shorter mapping and procedure duration with equivalent success to PbyP mapping.


Assuntos
Ablação por Cateter , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Eletrodos , Átrios do Coração , Humanos , Resultado do Tratamento
8.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32451232

RESUMO

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Assuntos
Betacoronavirus , Infecções por Coronavirus , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Pandemias , Pneumonia Viral , Austrália/epidemiologia , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/terapia , Humanos , Pneumonia Viral/epidemiologia , Pneumonia Viral/fisiopatologia , Pneumonia Viral/terapia , SARS-CoV-2
11.
Front Physiol ; 11: 616866, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33519522

RESUMO

RATIONALE: A quantitative framework to summarize and explain the quasi-stationary population dynamics of unstable phase singularities (PS) and wavelets in human atrial fibrillation (AF) is at present lacking. Building on recent evidence showing that the formation and destruction of PS and wavelets in AF can be represented as renewal processes, we sought to establish such a quantitative framework, which could also potentially provide insight into the mechanisms of spontaneous AF termination. OBJECTIVES: Here, we hypothesized that the observed number of PS or wavelets in AF could be governed by a common set of renewal rate constants λ f (for PS or wavelet formation) and λ d (PS or wavelet destruction), with steady-state population dynamics modeled as an M/M/∞ birth-death process. We further hypothesized that changes to the M/M/∞ birth-death matrix would explain spontaneous AF termination. METHODS AND RESULTS: AF was studied in in a multimodality, multispecies study in humans, animal experimental models (rats and sheep) and Ramirez-Nattel-Courtemanche model computer simulations. We demonstrated: (i) that λ f and λ d can be combined in a Markov M/M/∞ process to accurately model the observed average number and population distribution of PS and wavelets in all systems at different scales of mapping; and (ii) that slowing of the rate constants λ f and λ d is associated with slower mixing rates of the M/M/∞ birth-death matrix, providing an explanation for spontaneous AF termination. CONCLUSION: M/M/∞ birth-death processes provide an accurate quantitative representational architecture to characterize PS and wavelet population dynamics in AF, by providing governing equations to understand the regeneration of PS and wavelets during sustained AF, as well as providing insight into the mechanism of spontaneous AF termination.

12.
Heart Rhythm ; 17(2): 324-331, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31493590

RESUMO

BACKGROUND: The spatial resolution of pacemapping using 12-lead electrocardiography (ECG) or PaSo software is unknown. OBJECTIVE: The purpose of this study was to determine the spatial resolution of traditional ECG pacemapping and pacemapping using the PaSo coefficients. METHODS: Seventeen patients undergoing ablation of supraventricular tachycardias or atrioventricular node were included. After ablation, chamber (right ventricular outflow tract/rest of the right ventricle/left ventricle) geometry was created with Carto 3. Pacingwas performed from any point in these cardiac regions, the QRS morphology being the template and the point being considered as arrhythmia "origin." Subsequently, pacing was performed from points around the "origin" (1538 points). The QRS of these tagged points were compared by traditional ECG pacemapping and PaSo coefficients. The spatial resolution was calculated using correlations between the distance away from the origin (measured by 3 computational methods) and traditional ECG pacemapping and PaSo coefficients, independently. RESULTS: A 0.01-unit decrease in the PaSo coefficient resulted in 1.1 mm increased Cartesian distance (95% confidence interval [CI] 0.9-1.3 mm; P < .001) and 2.4 mm increased geodesic distance (95% CI 1.9-2.9 mm; P < .001) and 664 mm3 increase in convex hull volume (95% CI 423-906 mm3; P < .0001). For traditional ECG pacemapping, each decrease in lead match resulted in 1.7 mm increased Cartesian distance (95% CI 1.5-2.0 mm; P < .001) and 3.4 mm increased geodesic distance (95% CI 2.8-4.1 mm; P < .001) and 712 mm3 increase in convex hull volume (95% CI 599-830 mm3; P < .0001). Both PaSo coefficients and traditional pacemapping showed a significant inverse linear correlation with distance from the "origin." CONCLUSION: The resolution of mapping using the Paso software is better than that of traditional pacemapping.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Supraventricular/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico
13.
Heart Lung Circ ; 29(6): 921-930, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31526680

RESUMO

BACKGROUND: Transcatheter mitral valve implantation for degenerated bioprostheses has recently emerged as an alternative to redo mitral valve surgery, particularly in patients at high risk for reoperative cardiac surgery. We sought to examine our early experience of transcatheter transseptal mitral valve-in-valve procedures. METHODS: Prospectively collected data was retrospectively reviewed in patients undergoing transcatheter transseptal mitral valve-in-valve implantation using the Edwards Sapien 3 balloon expandable bioprosthesis (Edwards Lifesciences, Irvine, CA, USA). RESULTS: Seven (7) patients underwent the procedure between December 2017 and November 2018. Three (3) patients were young Indigenous Australians (age range 33-41years) who were not suitable for mechanical prostheses; four patients were elderly (age range 82-92 years) and considered high risk for reoperative surgery. The median (maximum, minimum) EuroSCORE II of the group was 7.32 (4.81, 19.89). Procedural success was obtained in six of the seven patients; these six patients had no significant complications and had a median hospital stay of 3 days. In one patient, the device displaced towards the left ventricle on inflation, resulting in left ventricular outflow tract obstruction and haemodynamic instability. Urgent redo mitral valve surgery and explantation of the transcatheter prosthesis was undertaken, however, this patient died postoperatively of multi-organ failure. Of the successfully deployed valves, the median (maximum, minimum) gradient across the new mitral prosthesis was 5.5 mmHg (4, 7) and only one patient had mild mitral regurgitation, all others had no or trivial regurgitation. At 30 days, these six patients are well and all are in New York Heart Association (NYHA) Class I. CONCLUSIONS: Our early experience with transcatheter transseptal mitral valve-in-valve implantation demonstrates this procedure to be feasible in our institution with acceptable early results. Further follow-up is necessary to determine the longevity of valves implanted in this manner, especially in the younger population.


Assuntos
Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Austrália , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Desenho de Prótese , Reoperação
14.
Heart Lung Circ ; 29(1): 86-93, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31526683

RESUMO

Atrial fibrillation (AF) is strongly associated with stroke risk but association on its own does not necessarily imply causality. Is AF a cause (risk factor) of stroke? Would treatment that reduces AF burden also reduce the burden of stroke? Or, perhaps, AF is a risk marker associated with a vascular syndrome in which there is co-existing atrial structural and electrical remodelling that results in the clinical manifestation of AF and the risk of stroke in parallel. A number of recent studies appear to detach AF as a direct cause of stroke. Studies in which cardiac implantable devices have been used to collect AF data preceding stroke appear to show no immediate temporal relationship. The Global Anticoagulant Registry in the Field - Atrial Fibrillation (GARFIELD-AF) a large worldwide registry of non-valvular AF, has shown that the risk of death exceeds the risk of stroke and that mortality, together with stroke and bleeding risk, is predicted by other vascular risk factors, defined by the CHA2DS2VASc score. Sir Bradford Hill proposed criteria to assess whether two associated factors are causal, more than 50 years ago. This method of analysing cause and effect in a complex scenario could be applied to AF and stroke. This paper aims to clinically appraise the evidence for each criterion outlined by Bradford Hill to single out whether the collective data supports one or the other.


Assuntos
Fibrilação Atrial , Sistema de Registros , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/metabolismo , Fibrilação Atrial/fisiopatologia , Biomarcadores/metabolismo , Humanos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/metabolismo , Acidente Vascular Cerebral/fisiopatologia
15.
Heart Vessels ; 35(2): 197-206, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31455993

RESUMO

To determine (a) whether chronic heart failure with reduced ejection fraction (HFrEF) is associated with increased glycocalyx shedding; (b) whether glycocalyx shedding in HFrEF with left ventricular dyssynchrony is related to inflammation, endothelial dysfunction and/or redox stress and is ameliorated by cardiac resynchronisation therapy. Glycocalyx shedding has been reported to be increased in heart failure and is a marker of increased mortality. Its role in dyssynchronous systolic heart failure and the effects of cardiac resynchronisation therapy (CRT) are largely unknown. Twenty-six patients with dyssynchronous HFrEF were evaluated before and 6 months after CRT insertion. Echocardiographic septal to posterior wall delay (SPWD) assessed intra-ventricular mechanical dyssynchrony, and quality of life, integrity of nitric oxide (NO) signalling, inflammatory and redox-related biomarkers were measured. Glycocalyx shedding was quantitated via plasma levels of the glycocalyx component, syndecan-1. Syndecan-1 levels pre-CRT were inversely correlated with LVEF (r = - 0.45, p = 0.02) and directly with SPWD (r = 0.44, p = 0.02), QOL (r = 0.39, p = 0.04), plasma NT-proBNP (r = 0.43, p = 0.02), and the inflammatory marker, symmetric dimethylarginine (SDMA) (r = 0.54, p = 0.003). On multivariate analysis, syndecan-1 levels were predicted by SPWD and SDMA (ß = 0.42, p = 0.009 and ß = 0.54, p = 0.001, respectively). No significant correlation was found between syndecan-1 levels and other markers of endothelial dysfunction/inflammatory activation. Following CRT there was no significant change in syndecan-1 levels. In patients with dyssynchronous HFrEF, markers of glycocalyx shedding are associated with the magnitude of mechanical dyssynchrony and elevation of SDMA levels and inversely with LVEF. However, CRT does not reverse this process.


Assuntos
Terapia de Ressincronização Cardíaca , Células Endoteliais/metabolismo , Endotélio Vascular/metabolismo , Glicocálix/metabolismo , Insuficiência Cardíaca Sistólica/terapia , Sindecana-1/sangue , Disfunção Ventricular Esquerda/terapia , Idoso , Biomarcadores/sangue , Doença Crônica , Endotélio Vascular/fisiopatologia , Feminino , Insuficiência Cardíaca Sistólica/sangue , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/fisiopatologia , Humanos , Masculino , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
17.
JACC Cardiovasc Imaging ; 13(2 Pt 2): 604-612, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31607658

RESUMO

OBJECTIVES: This study sought to determine the long-term prognostic value of myocardial deformation imaging by echocardiography in risk stratification of sudden cardiac death (SCD) and malignant ventricular arrhythmias (VAs) in a large consecutive cohort of patients with left ventricular (LV) systolic impairment, irrespective of its etiology. BACKGROUND: Left ventricular ejection fraction (LVEF) is limited for prediction of SCD. Echocardiographic strain-derived mechanical dispersion (MD) and global longitudinal strain (GLS) has been linked to VA and SCD. However, due to low event rates, the role of these parameters has not been fully elucidated. METHODS: Consecutive clinically stable patients who underwent echocardiographic study performed in an outpatient setting from 2008 to 2014 with a Simpson left ventricular ejection fraction (LVEF) ≤45% were included in the study. Strain analysis was performed in which the LV was separated into 16 segments for regional analysis. Mechanical dispersion (MD) was calculated as the SD of the time to peak of each of the 16 regions. Outcome data were obtained from medical records. RESULTS: A total of 939 patients were included in the study, with median LVEF of 37% (interquartile range 30% to 42%). At follow-up (91.4 ± 23.4 months), 96 VA events had occurred. Multivariate analysis demonstrated that only MD ≥75 ms (hazard ratio: 9.45; 95% confidence interval: 4.75 to 18.81; p < 0.0001) was predictive of VA events. Low MD predicted a low event rate, irrespective of LVEF. CONCLUSIONS: Using LVEF alone is inferior for prediction of VA and SCD, particularly in patients with moderately reduced LVEF. MD is easily obtained from standard echocardiographic images and can be used to improve risk prognosis, particularly in patients who are currently excluded from cardiac defibrillator insertion based on LVEF.


Assuntos
Morte Súbita Cardíaca/etiologia , Ecocardiografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Austrália do Sul , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
18.
Intern Med J ; 50(10): 1207-1216, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31762133

RESUMO

BACKGROUND: Few safety data exist comparing clinical outcomes in Australian public and private hospitals. We hypothesised that differences could exist between public and private hospitals due to differences in acuity and patient-level co-morbidities. AIMS: To report comparative complications of cardiac implantable electronic device (CIED) placement in public and private hospitals. METHODS: We conducted an observational cohort study of outcomes of patients aged >18 years from 2010 to 2015 undergoing a new permanent pacemaker (PPM), implantable cardioverter defibrillator (ICD) or cardiac resynchronisation therapy pacemaker or defibrillator (CRT-D/P) implant in NSW and Queensland public and private hospitals. The primary endpoint was major CIED-related complications occurring in-hospital or within 90 days of discharge. The independent effect of hospital sector was determined using multiple logistic regression, adjusting for covariates, including age, sex, co-morbidities and procedural acuity. RESULTS: A total of 32 364 new CIED implants (PPM 23 845, ICD 5361 and CRT-D/P 3158) were included (49% in private hospitals). Overall, 8.0% of private hospital procedures and 9.6% public hospital procedures experienced at least one complication. After adjustment, the overall risk of CIED complications was similar in private and public hospitals (OR: 0.92, 95% CI: 0.84-1.00, P = 0.06). In analysis of individual complications, adjusted all-cause in-hospital mortality was higher in private hospitals, (OR: 1.49, 95% CI: 1.03-2.16, P = 0.036) primarily driven by an excess mortality in acute cases. The adjusted risk of in-hospital generator operation (OR: 0.53, 95% CI: 0.30-0.94, P = 0.03) and post-discharge infection (OR: 0.61, 95% CI: 0.46-0.81, P < 0.001) was lower in private hospitals. CONCLUSIONS: These data identify important similarities and differences in safety outcomes of CIED implantation between Australian public and private hospitals.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Assistência ao Convalescente , Idoso , Austrália/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Hospitais Privados , Humanos , Alta do Paciente , Queensland , Estudos Retrospectivos , Fatores de Risco
19.
Circ Arrhythm Electrophysiol ; 12(12): e007569, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31813270

RESUMO

BACKGROUND: Despite a century of research, no clear quantitative framework exists to model the fundamental processes responsible for the continuous formation and destruction of phase singularities (PS) in cardiac fibrillation. We hypothesized PS formation/destruction in fibrillation could be modeled as self-regenerating Poisson renewal processes, producing exponential distributions of interevent times governed by constant rate parameters defined by the prevailing properties of each system. METHODS: PS formation/destruction were studied in 5 systems: (1) human persistent atrial fibrillation (n=20), (2) tachypaced sheep atrial fibrillation (n=5), (3) rat atrial fibrillation (n=4), (5) rat ventricular fibrillation (n=11), and (5) computer-simulated fibrillation. PS time-to-event data were fitted by exponential probability distribution functions computed using maximum entropy theory, and rates of PS formation and destruction (λf/λd) determined. A systematic review was conducted to cross-validate with source data from literature. RESULTS: In all systems, PS lifetime and interformation times were consistent with underlying Poisson renewal processes (human: λf, 4.2%/ms±1.1 [95% CI, 4.0-5.0], λd, 4.6%/ms±1.5 [95% CI, 4.3-4.9]; sheep: λf, 4.4%/ms [95% CI, 4.1-4.7], λd, 4.6%/ms±1.4 [95% CI, 4.3-4.8]; rat atrial fibrillation: λf, 33%/ms±8.8 [95% CI, 11-55], λd, 38%/ms [95% CI, 22-55]; rat ventricular fibrillation: λf, 38%/ms±24 [95% CI, 22-55], λf, 46%/ms±21 [95% CI, 31-60]; simulated fibrillation λd, 6.6-8.97%/ms [95% CI, 4.1-6.7]; R2≥0.90 in all cases). All PS distributions identified through systematic review were also consistent with an underlying Poisson renewal process. CONCLUSIONS: Poisson renewal theory provides an evolutionarily preserved universal framework to quantify formation and destruction of rotational events in cardiac fibrillation.


Assuntos
Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Modelos Cardiovasculares , Fibrilação Ventricular/fisiopatologia , Animais , Evolução Biológica , Simulação por Computador , Modelos Animais de Doenças , Humanos , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Ratos , Reprodutibilidade dos Testes , Carneiro Doméstico , Processos Estocásticos , Fatores de Tempo , Fibrilação Ventricular/diagnóstico
20.
Sci Rep ; 9(1): 18243, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31796767

RESUMO

Magnetic resonance imaging (MRI) has long been contraindicated in patients with implanted pacemakers, defibrillators, and cardiac resynchronisation therapy (CRT) devices due to the risk of adverse effects through electromagnetic interference. Since many recipients of these devices will have a lifetime indication for an MRI scan, the implantable systems should be developed as 'MRI-conditional' (be safe for the MRI environment under predefined conditions). We evaluated the clinical safety of several Biotronik ProMRI ('MRI-conditional') defibrillator and CRT systems during head and lower lumbar MRI scans at 1.5 Tesla. The study enrolled 194 patients at 22 sites in Australia, Canada, and Europe. At ≥9 weeks after device implantation, predefined, non-diagnostic, specific absorption rate (SAR)-intensive head and lower lumbar MRI scans (total ≈30 minutes per patient) were performed in 146 patients that fulfilled pre-procedure criteria. Three primary endpoints were evaluated: freedom from serious adverse device effects (SADEs) related to MRI and defibrillator/CRT (leading to death, hospitalisation, life-threatening condition, or potentially requiring implanted system revision or replacement), pacing threshold increase, and sensing amplitude decrease, all at the 1-month post-MRI clinical visit. No MRI-related SADE occurred. Lead values remained stable, measured in clinic and monitored daily by the manufacturer home monitoring technology.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Feminino , Cabeça/diagnóstico por imagem , Humanos , Região Lombossacral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...