Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JBJS Case Connect ; 13(4)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831804

RESUMO

CASE: A 16-year-old male patient presented with isolated bilateral sacroiliac (SI) joint dislocation. In this report, we discuss the presentation and focus on strategies for operative reduction and fixation for this rare injury. CONCLUSION: In conclusion, we present a case of a bilateral ligamentous SI joint dislocation in an adolescent. The patient was reduced in the supine position with a sacral bump and bilateral traction with direct and indirect reduction aids inserted through a lateral window. Bilateral SI screws stabilized the pelvis, facilitating uncomplicated healing.


Assuntos
Parafusos Ósseos , Luxações Articulares , Masculino , Adolescente , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/cirurgia , Articulação Sacroilíaca/lesões , Fixação Interna de Fraturas , Pelve
2.
Clin Biomech (Bristol, Avon) ; 80: 105191, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33045492

RESUMO

INTRODUCTION: High rates of morbidity and mortality following flail chest rib fractures are well publicized. Standard of care has been supportive mechanical ventilation, but serious complications have been reported. Internal rib fixation has shown improvements in pulmonary function, clinical outcomes, and decreased mortality. The goal of this study was to provide a model defining the biomechanical benefits of internal rib fixation. METHODS: One human cadaver was prepared with an actuator providing anteroposterior forces to the thorax and rib motion sensors to define interfragmentary motion. Cadaveric model was validated using a prior study which defined costovertebral motion to create a protocol using similar technology and procedure. Ribs 4-6 were fixed with motion sensors anteriorly, laterally and posteriorly. Motion was recorded with ribs intact before osteotomizing each rib anteriorly and laterally. Flail chest motion was record with fractures subsequently plated and analyzed. Motion was recorded in the sagittal, coronal and transverse axes. FINDINGS: Compared to the intact rib model, the flail chest model demonstrated an 11.3 times increase in sagittal plane motion, which was reduced to 2.1 times the intact model with rib plating. Coronal and sagittal plane models also saw increases of 9.7 and 5.1 times, respectively, with regards to flail chest motion. Both were reduced to 1.2 times the intact model after rib plating. INTERPRETATION: This study allows quantification of altered ribcage biomechanics after flail chest injuries and suggests rib plating is useful in restoring biomechanics as well as contributing to improving pulmonary function and clinical outcomes.


Assuntos
Fixação Interna de Fraturas , Fenômenos Mecânicos , Fraturas das Costelas/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Tórax Fundido/etiologia , Tórax Fundido/fisiopatologia , Tórax Fundido/cirurgia , Humanos , Fraturas das Costelas/complicações , Fraturas das Costelas/fisiopatologia , Traumatismos Torácicos/complicações
3.
Orthopedics ; 43(5): 262-268, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32745228

RESUMO

Proximal humerus fractures, although common, have high rates of failure after open reduction and internal fixation. The use of a fibular allograft has been explored as a means to decrease complications, particularly varus collapse and the need for revision surgery. The authors performed a retrospective review of 133 proximal humerus fractures managed surgically with locking plates (n=72) or locking plates with fibular allograft intramedullary struts (n=61). Demographic, intraoperative, and postoperative variables were collected and analyzed. The fibular allograft group was more likely to be older (P<.01), be female (P=.04), and have a history of osteoporosis (P=.01). No differences were noted in the proportions of 2-, 3-, or 4-part fractures between groups. Average follow-up was 28 weeks. Medial calcar length was longer in the locking plate only group (P=.04); however, this group demonstrated a decreased head shaft angle (P=.01) and a trend toward increased rates of varus collapse (P=.06). No significant differences were found regarding other radiographic complications, irrespective of fracture complexity. A notable decrease in fluoroscopy time was seen with strut use (P=.04), but operative time and blood loss were similar between groups. A significant decrease in revision surgery rate was found with use of an allograft strut (P=.05). Using a strut appears to preserve the radiographic head shaft angle and decrease the risk of fracture collapse in 2-, 3-, and 4-part fractures, without increasing surgical time or morbidity. Use of an intramedullary strut appears to reduce the need for revision surgery, particularly in 3- and 4-part fractures. [Orthopedics. 2020;43(5):262-268.].


Assuntos
Placas Ósseas , Fíbula/transplante , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
JBJS Case Connect ; 10(1): e0011, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32224659

RESUMO

CASE: A 33-year-old man with recurrent intrathoracic scapular dislocation due to previous trauma-related chest wall resection successfully underwent the 2-stage induced membrane technique commonly known as the Masquelet technique; this procedure effectively created 2 new ribs that resolved his symptoms. CONCLUSIONS: Techniques for chest wall reconstruction for bone loss are quite limited, and these often consist of filling defects with a layered patch; this often cannot withstand the cyclical respiratory motion. Use of the induced membrane technique appears to carry potential when used in the chest wall, and this report describes a technique by which this procedure can be reliably performed.


Assuntos
Transplante Ósseo/métodos , Tórax Fundido/complicações , Fraturas não Consolidadas/complicações , Fraturas das Costelas/complicações , Parede Torácica/cirurgia , Adulto , Clavícula/lesões , Clavícula/cirurgia , Humanos , Masculino , Procedimentos de Cirurgia Plástica , Parede Torácica/diagnóstico por imagem
5.
Cureus ; 12(3): e7399, 2020 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-32337125

RESUMO

Subcutaneous emphysema is typically due to an air leak through the parietal pleura, allowing air to escape from the lung parenchyma into the adjacent soft tissue. Most cases are benign and self-limiting; however, when enough air is forced into the subcutaneous tissues allowing the air to spread into the neck, tracheal compression and respiratory distress can occur. Tube thoracotomy and endotracheal intubation are generally sufficient to overcome this respiratory compromise. However, occasionally other invasive measures are required to allow the air leak to resolve. Traditionally, this would involve placement of an incision or two into the anterior chest wall to allow decompression to the outside environment. Limited evidence exists regarding negative pressure wound therapy devices being used successfully with open incisions for the management of massive subcutaneous emphysema.  We present the initial case of successful use of a loosely closed incision negative pressure therapy for massive subcutaneous emphysema. In this instance, the patient's thoracic injury was successfully stabilized and use of the negative pressure therapy device allowed the incisions to be closed with a much more cosmetically pleasing result.

6.
J Long Term Eff Med Implants ; 30(1): 57-60, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33389916

RESUMO

Operative treatment of quadriceps and patellar tendon ruptures with transosseous bone tunnels remains the gold standard, but potential benefits exist with the use of suture anchor fixation for these injuries. Such benefits include stronger biomechanical fixation, reduced soft-tissue disruption, smaller incision, reduced postoperative pain, shorter operative time, lower knot burden, lack of prepatellar bursa scarring, and avoidance of some transosseous repair risks. In this investigation, we present the reproducible technique and outcomes of using suture anchors for repair of quadriceps and patellar tendon ruptures.


Assuntos
Ligamento Patelar , Âncoras de Sutura , Fenômenos Biomecânicos , Humanos , Patela/cirurgia , Ligamento Patelar/cirurgia , Técnicas de Sutura
7.
J Long Term Eff Med Implants ; 29(3): 247-254, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32478998

RESUMO

BACKGROUND: The incidence of posttraumatic arthrosis after acetabular fractures is significant, and patients frequently require secondary total hip arthroplasty. Conversion arthroplasty is more technically difficult, and there is higher risk than with routine primary total hip arthroplasty. The goal of this study was to identify the challenges and risks of secondary total hip arthroplasty compared to primary total hip arthroplasty. METHODS: We retrospectively identified 30 patients who underwent secondary total hip arthroplasty after open reduction and internal fixation of an acetabulum fracture and compared them with 20 patients who had undergone primary total hip arthroplasty for degenerative joint disease. RESULTS: Demographic data were similar between groups. Hardware removal was deemed necessary in 21 patients (70%). Allograft was needed for bone defects in 33% of secondary total hip arthroplasty cases, while no primary cases required grafting. Operative time (217.4 vs. 113.7 min, P < 0.01) and estimated blood loss (875.8 vs. 365 mL, P < 0.01) were significantly greater in the secondary arthroplasty group. Early postoperative complications were also higher in the secondary arthroplasty group. CONCLUSIONS: Total hip arthroplasty after acetabular fracture open reduction and internal fixation is a more complex procedure due to exposure difficulty, possible implant removal, management of bony deficits, and the potential use of cages and revision components. Experienced surgeons managing these complicated cases must take great care not only in ensuring appropriate technique but also in appropriate patient education regarding increased risk of major and minor complications. LEVEL OF EVIDENCE: Level III.


Assuntos
Acetábulo/lesões , Artroplastia de Quadril , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/cirurgia , Redução Aberta/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Perda Sanguínea Cirúrgica , Remoção de Dispositivo , Feminino , Humanos , Fixadores Internos/efeitos adversos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Reoperação , Estudos Retrospectivos , Adulto Jovem
8.
Int J MS Care ; 16(3): 146-52, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25337057

RESUMO

BACKGROUND: Footdrop is a common gait deviation in people with multiple sclerosis (MS) leading to impaired gait and balance as well as decreased functional mobility. Functional electrical stimulation (FES) provides an alternative to the current standard of care for footdrop, an ankle-foot orthosis (AFO). FES stimulates the peroneal nerve and activates the dorsiflexor muscles, producing an active toe clearance and a more normal gait. This study was undertaken to determine the effects of a 2-week FES Home Assessment Program on gait speed, perceived walking ability, and quality of life (QOL) among people with MS-related footdrop. METHODS: Participants completed the Timed 25-Foot Walk test (T25FW) and two self-report measures: 12-item Multiple Sclerosis Walking Scale (MSWS-12) and 29-item Multiple Sclerosis Impact Scale (MSIS-29). Measures were taken without FES before and with FES after 2 weeks of full-time FES wear. RESULTS: A total of 19 participants (10 female, 9 male) completed the study; mean age and duration of disease were 51.77 ± 10.16 and 9.01 ± 7.90 years, respectively. Use of FES for 2 weeks resulted in a significant decrease in time to complete the T25FW (P < .0001), the MSWS-12 standardized score (P < .0001), and the MSIS-29 total (P < .0001), Physical subscale (P < .0001), and Psychological subscale (P = .0006) scores. CONCLUSIONS: These results suggest that use of FES can significantly improve gait speed, decrease the impact of MS on walking ability, and improve QOL in people with MS-related footdrop even over a short period of time.

9.
Health Estate ; 63(2): 23-5, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19297839

RESUMO

There are many factors to be considered during a retrofit, not least of which should be the building control system. But as Sean McGowan discovered, this is often the one element not given due consideration, resulting in poor performance, higher running costs, and elevated greenhouse emissions, despite the system's aims.


Assuntos
Ar Condicionado/métodos , Arquitetura Hospitalar , Ar Condicionado/economia , Ar Condicionado/normas , Estudos de Casos Organizacionais , Austrália do Sul
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA