A cross-reactive array of semiselective chemiresistive sensors made of polymer-graphene nanoplatelet (GNP) composite coated electrodes was examined for detection and discrimination of chemical warfare agents (CWA). The arrays employ a set of chemically diverse polymers to generate a unique response signature for multiple CWA simulants and background interferents. The developed sensors' signal remains consistent after repeated exposures to multiple analytes for up to 5 days with a similar signal magnitude across different replicate sensors with the same polymer-GNP coating. An array of 12 sensors each coated with a different polymer-GNP mixture was exposed 100 times to a cycle of single analyte vapors consisting of 5 chemically similar CWA simulants and 8 common background interferents. The collected data was vector normalized to reduce concentration dependency, z-scored to account for baseline drift and signal-to-noise ratio, and Kalman filtered to reduce noise. The processed data was dimensionally reduced with principal component analysis and analyzed with four different machine learning algorithms to evaluate discrimination capabilities. For 5 similarly structured CWA simulants alone 100% classification accuracy was achieved. For all analytes tested 99% classification accuracy was achieved demonstrating the CWA discrimination capabilities of the developed system. The novel sensor fabrication methods and data processing techniques are attractive for development of sensor platforms for discrimination of CWA and other classes of chemical vapors.


Assuntos
Substâncias para a Guerra Química/análise , Técnicas de Química Analítica/instrumentação , Grafite/química , Nanocompostos/química , Polímeros/química , Substâncias para a Guerra Química/química , Limite de Detecção , Volatilização
2.
Biosensors (Basel) ; 3(3): 286-96, 2013 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-25586259

RESUMO

Investigations were conducted to develop an electrotextile using a nonwoven polypropylene fiber platform conformally coated in a conductive, functionalized copolymer of polypyrrole and 3-thiopheneacetic acid (3TAA). The objectives of this study were to determine: (1) if the inclusion of 3TAA in the polymerization process would have an effect on the availability of binding sites in the high-surface area electrotextile for biorecognition elements and (2) how the increase in the concentration of 3TAA would affect the physical characteristics of the coating, resistivity of the sample and availability of binding sites. It was found that the addition of 3TAA to the polymerization process resulted in an increase in the size of the polypyrrole coating, as well as the material resistivity and available binding sites for biorecognition elements. These factors were used to determine which of the tested concentrations was best for biosensor development. A polymer coated membrane sample containing a concentration within the range of 10-50 mg/mL of 3TAA was selected as the best for future biosensor work.

3.
Biosensors (Basel) ; 2(4): 465-78, 2012 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-25586036

RESUMO

An electrotextile with a biosensing focus composed of conductive polymer coated microfibers that contain functional attachment sites for biorecognition elements was developed. Experiments were conducted to select a compound with a pendant functional group for inclusion in the polymer, a fiber platform, and polymerization solvent. The effects of dopant inclusion and post-polymerization wash steps were also analyzed. Finally, the successful attachment of avidin, which was then used to capture biotin, to the electrotextile was achieved. The initial results show a nonwoven fiber matrix can be successfully coated in a conductive, functionalized polymer while still maintaining surface area and fiber durability. A polypropylene fiber platform with a conductive polypyrrole coating using iron (III) chloride as an oxidant, water as a solvent, and 5-sulfosalicylic acid as a dopant exhibited the best coating consistency, material durability, and lowest resistance. Biological attachment of avidin was achieved on the fibers through the inclusion of a carboxyl functional group via 3-thiopheneacetic acid in the monomer. The immobilized avidin was then successfully used to capture biotin. This was confirmed through the use of fluorescent quantum dots and confocal microscopy. A preliminary electrochemical experiment using avidin for biotin detection was conducted. This technology will be extremely useful in the formation of electrotextiles for use in biosensor systems.