1.
J Grad Med Educ ; 6(1): 100-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24701318

RESUMO

BACKGROUND: Innovative online technology can enhance the practice of medicine, yet it also may be a forum for unprofessional behavior. OBJECTIVE: We surveyed program directors regarding their perceptions and experiences with residents' use of social networking sites (SNS). METHODS: In September 2011, we sent an online survey to program directors and associate program directors of pediatrics residency programs within the United States who are members of the Association of Pediatric Program Directors. RESULTS: A total of 162 program directors or associate program directors (representing 50% of residency programs) responded to the survey. One-third of respondents are "very familiar" with SNS and 23% use them "daily or often." Most respondents (70%) rated "friending" peers as "completely appropriate," whereas only 1% of respondents rated "friending" current or past patients as "completely appropriate." More than one half of respondents believe inappropriate behavior on SNS is "somewhat" or "very" prevalent, and 91% are "somewhat" or "very" concerned that the prevalence of inappropriate behavior on SNS may increase. The most commonly reported problematic online activity was posting inappropriate comments about the workplace. Posting of inappropriate comments about self, patients, and staff also was observed. Residency programs commonly educate trainees about SNS during intern orientation (45%), or using written guidelines (29%) and ad hoc remediation (16%). CONCLUSIONS: As educators teach trainees principles of online professionalism, appropriate use of SNS needs to be included in the training process. Curricular efforts may be hindered by some program directors' lack of familiarity with SNS.

2.
Physiol Meas ; 33(2): 117-30, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22227810

RESUMO

This paper investigates the main characteristics of the magneto-hemodynamic (MHD) response for application as a biomarker of vascular blood flow. The induced surface potential changes of a volunteer exposed to a 3 T static B0 field of a magnetic resonance imaging (MRI) magnet were measured over time at multiple locations by an electrocardiogram device and compared to simulation results. The flow simulations were based on boundary conditions derived from MRI flow measurements restricted to the aorta and vena cava. A dedicated and validated low-frequency electromagnetic solver was applied to determine the induced temporal surface potential change from the obtained 4D flow distribution using a detailed whole-body model of the volunteer. The simulated MHD signal agreed with major characteristics of the measured signal (temporal location of main peak, magnitude, variation across chest and along torso) except in the vicinity of the heart. The MHD signal is mostly influenced by the aorta; however, more vessels and better boundary conditions are needed to analyze the finer details of the response. The results show that the MHD signal is strongly position dependent with highly variable but reproducibly measurable distinguished characteristics. Additional investigations are necessary before determining whether the MHD effect is a reliable reference for location-specific information on blood flow.


Assuntos
Vasos Sanguíneos/fisiologia , Simulação por Computador , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Aorta/fisiologia , Eletrocardiografia , Eletrodos , Campos Eletromagnéticos , Humanos , Masculino , Modelos Cardiovasculares , Veias Cavas/fisiologia
3.
J Grad Med Educ ; 3(3): 383-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22942968

RESUMO

BACKGROUND: The nationwide decline in pediatric admissions to community hospitals threatens the sustainability of small pediatric residency programs. Little is known about the response of small programs to this challenge. OBJECTIVES: We report on the design and evaluation of an innovative, collaborative model for pediatric inpatient training between an academic community medical center and a children's hospital. METHODS: We describe the operational, academic, and financial features of the model. Outcome measures include patient volume and subspecialty mix, resident and faculty perceptions as reported in an anonymous survey, and Accreditation Council for Graduate Medical Education Residency Review Committee (RRC) review. RESULTS: In 2003, Albert Einstein Medical Center (Einstein) closed its pediatric inpatient unit and established an independent teaching service at St Christopher's Hospital for Children (St Christopher's) in Philadelphia, Pennsylvania. Under the new model, patient volume and subspecialty mix more than tripled. Einstein residents and faculty identified 5 major strengths: level of responsibility and decision making, caring for medically complex children, quality of teaching, teamwork, and opportunity to participate in academic activities at a children's hospital. St Christopher's leadership reported increased volume, no disruption of their residency program, and no dilution of clinical teaching material. The Einstein program was reaccredited by the RRC in 2006 for 2 years and in 2009 for 4 years. CONCLUSION: A collaborative model for inpatient training was successful in maintaining a community hospital-based pediatric residency program. Positive outcomes were documented for the residency program, the parent community hospital, and the collaborating children's hospital.

4.
J Long Term Eff Med Implants ; 21(4): 299-319, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22577997

RESUMO

Six Talent stent-grafts were harvested at reoperations (N=5) and autopsy (N=1). The explants were observed nondestructively, including gross morphology, X-rays, CT scans and closed pressure system analysis. The Nitinol frames in three devices harvested at reoperations and another harvested at autopsy were intact. One had a stent fracture of the proximal bare stent, and one had a wire fracture of a thin proximal external supporting stent as well as a hole in the fabric just above the bifurcation. For the three devices structurally intact, reoperations were performed for a type 1A endoleak (one patient) and aorto-enteric fistulas (two patients). The healing characteristics were poor or absent. The fabric in the main body of the grafts harvested after aorto-enteric fistula was devoid of biological deposits. Two of the grafts harvested at reoperation demonstrated fabric holes of up to 4 mm 2. The device obtained at autopsy showed an almost continuous internal capsule with variable thickness. The luminal surface was smooth, but the capsule detached easily. The devices explanted at reoperations showed various levels of impaired biofunctionality associated with adverse outcomes. The stent-graft retrieved from autopsy was intact.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Análise de Falha de Equipamento , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Evolução Fatal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação
5.
J Magn Reson Imaging ; 31(6): 1473-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20512901

RESUMO

Clozapine is an atypical, neuroleptic medication that can cause myocarditis. While the "gold standard" for diagnosis of myocarditis is perceived to be via myocardial biopsy, cardiovascular magnetic resonance (CMR) has also proven its utility in this respect, primarily through its ability to detect myocardial scar by late-gadolinium enhancement (LGE). Until recently, however, clozapine-induced myocarditis specifically has not been known to be associated with LGE on CMR. In that particular case, LGE was demonstrated in a patient with clozapine-induced myocarditis. However, quite important, that patient also had specific abnormalities on the electrocardiogram (ECG) and echocardiogram that corresponded to the area of LGE demonstrated by CMR. We highlight a case series of three patients with clozapine-induced myocarditis and provide a literature review to discuss and critically appraise the true incremental diagnostic value of CMR in such patients with normal ECG and echocardiography.


Assuntos
Doenças Cardiovasculares/diagnóstico , Clozapina/efeitos adversos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Miocardite/patologia , Esquizofrenia/diagnóstico , Adolescente , Antipsicóticos/efeitos adversos , Doenças Cardiovasculares/patologia , Dor no Peito/diagnóstico , Humanos , Masculino , Miocardite/induzido quimicamente , Esquizofrenia/complicações
9.
Am Heart Hosp J ; 8(2): E133-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21928183

RESUMO

Cardiac tamponade (CT) is a pathophysiologic continuum where hemodynamic embarrassment occurs as a result of progressive, decreased venous return that impairs diastolic ventricular filling, which in turn, when uncorrected, severely compromises cardiac output. While CT is classically associated with high intrapericardial pressures due to rapidly accumulating large pericardial effusions, low-pressure CT is a recognized entity in which a comparatively low intrapericardial pressure could result in cardiac chamber compression and subsequent cardiovascular collapse. In this article, we highlight a previously unreported scenario of rapidly re-accumulating, acute CT in the setting of left ventricular rupture in a patient who had presumably presented with low-pressure CT due to hemoperiardium.


Assuntos
Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/fisiopatologia , Ruptura Cardíaca/diagnóstico , Ruptura Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/fisiopatologia , Idoso , Débito Cardíaco , Diagnóstico Diferencial , Progressão da Doença , Ecocardiografia , Feminino , Humanos , Síncope , Tomografia Computadorizada por Raios X
12.
Artigo em Inglês | MEDLINE | ID: mdl-19140034

RESUMO

Twenty-nine modular stent-grafts deployed transrenally to repair AAAs with short necks in dogs were harvested at autopsy of the animals after scheduled durations of implantations of 10 days, one month, three months, and six months. Analyses of the explanted devices included non-destructive techniques such as gross observations, X-rays CT scan, IVUS and angioscopy. Further to appropriate dissection, histological investigations were carried out by means of scanning electron microscopy (SEM) and light microscopy. All the 29 specimens were extensively encapsulated with fibrous tissues but the fibrous capsule was thin in six of them; four capsules were ulcerated. The X-rays confirmed the stability of the devices that were still straight (12), slightly bent (12) or bent (4). The modules were misaligned in only one case. IVUS and angioscopy confirmed the patency of all the stent-grafts with thin internal capsules both proximally and distally with variable capsulation in the mid-section of the grafts. The left renal artery orifices were found to be patent at dissection with no obstruction to flow. The luminal flow surface of the stent-grafts was smooth and glistening proximally and distally containing endothelial like cells and vasa-vasorum. Poor healing was noted in the aneurysm area. Transrenal deployment of this modular stent-graft is feasible and gave excellent results with regard to biofunctionality and biocompatibility. The device proved to be safe and efficient.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Rim/cirurgia , Stents , Transplantes , Angioscopia , Animais , Aneurisma da Aorta Abdominal/patologia , Cães , Teste de Materiais , Microscopia Eletrônica de Varredura , Raios X
13.
Med Image Comput Comput Assist Interv ; 12(Pt 1): 124-31, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20425979

RESUMO

Obtaining detailed, patient-specific blood flow information would be very useful in detecting and monitoring cardio-vascular diseases. Current approaches rely on computational fluid dynamics to achieve this; however, these are hardly usable in the daily clinical routine due to the required technical supervision and long computing times. We propose a fast measurement enhancement method that requires neither supervision nor long computation and it is the objective of this paper to evaluate its performance as compared to the state-of-the-art. To this end a large set of abdominal aortic bifurcation geometries was used to test this technique and the results were compared to measurements and numerical simulations. We find that this method is able to dramatically improve the quality of the measurement information, in particular the flow-derived quantities such as wall shear stress. Additionally, good estimation of unmeasurable quantities such as pressure can be provided. We demonstrate that this approach is a practical and clinically feasible alternative to fully-blown, time-consuming, patient-specific flow simulations.


Assuntos
Aorta Abdominal/anatomia & histologia , Aorta Abdominal/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Reologia/métodos , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Cardiovasc Magn Reson ; 10: 58, 2008 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-19087273

RESUMO

A 35 year-old asymptomatic Caucasian female with a family history of hypertrophic cardiomyopathy (HCM) was referred for cardiologic evaluation. The electrocardiogram and transthoracic echocardiogram were normal. Cardiovascular magnetic resonance (CMR) was performed for further assessment of myocardial function and presence of myocardial scar. CMR showed normal left ventricular systolic size, measurements and function. However, there was extensive, diffuse late gadolinium enhancement (LGE) throughout the left ventricle. This finding was consistent with extensive myocardial scarring and was highly suggestive of advanced, non-ischemic cardiomyopathy. Genotyping showed a heterozygous mis-sense mutation (275G>A) in the cardiac troponin T (TNNT2) gene, which is causally associated with HCM. There have been no previous reports of such extensive, atypical pattern of myocardial scarring despite an otherwise structurally and functionally normal left ventricle in an asymptomatic individual with HCM. This finding has important implications for phenotype screening in HCM.


Assuntos
Cardiomiopatia Hipertrófica Familiar/patologia , Meios de Contraste , Gadolínio , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Adulto , Cardiomiopatia Hipertrófica Familiar/genética , Ecocardiografia , Eletrocardiografia , Feminino , Genótipo , Ventrículos do Coração/patologia , Humanos , Mutação de Sentido Incorreto , Fenótipo , Troponina T/genética
15.
Artigo em Inglês | MEDLINE | ID: mdl-18649168

RESUMO

Severely angulated (> 60 degrees ) or short (< 15 mm) proximal necks remain significant anatomical limitations for endovascular stent-graft repairs for abdominal aortic aneurysms. Ensuring proper proximal fixation of the stent-graft to the host artery without the short-or long-term risks of endoleak or migration represents a particular technical challenge for these anatomical circumstances. An innovative balloon expandable stent combined with a weft-knitted prosthesis was specifically designed for these situations by modelling the stent to the neck anatomy without overdistension or potential barotrauma allowing better incorporation of the device. The Latecba stent-graft consists of a 2 parts modular design. The first one, Module A, is deployed at the transrenal level and consists of a Palmaz type stent whose first half is bare and second half is sutured to a crimped weft-knitted polyester graft whose distal end holds a constriction. The second Module B is a non-crimped weft-knitted graft attached to 2 stainless steel stents. The first stent is entirely contained in the proximal textile tube, allowing fixation to module A. The second stent, which is left uncovered over the distal third, ensures proper fixation of the stent-graft distally. Following the creation of a prosthetic aneurysm in the infrarenal aorta in 32 dogs, 29 received the Latecba stent-graft for scheduled durations of 10 days, 1 month, 3 months and 6 months. Proper deployment of the stent-grafts was achieved without difficulty. All 29 animals survived and the devices were all patent at sacrifice. No device defects or migrations were observed and the stent-grafts proved to be efficient in this setting to exclude the aneurysm. Analyses of the explanted devices (gross observations, RX, CT scan, IVUS, angioscopy) confirmed the stability of this modular stent-graft. Further on-going clinical investigations are warranted to validate this concept before this stent-graft becomes commercially available without any restriction.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Stents , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Cães , Desenho de Prótese , Radiografia , Artéria Renal/cirurgia , Ultrassonografia
17.
J Long Term Eff Med Implants ; 18(3): 181-204, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-20001892

RESUMO

Further to the rapid enlargement of an aneurysm to 5.6 cm in diameter after 3 years of surveillance, a 79-year-old patient was fitted with a Vanguard modular stent graft and monitored on a regular basis for 6 years. Two years later, the aneurysmal sac ruptured. The patient died 1 month after an open surgery. The device was devoid of any encapsulation and the ipsilateral limb was detached from the body. The Nitinol skeleton was mostly maintained, however, some polypropylene sutures were broken. The resulting motion of the sharp-angled Nitinol wires caused abrasion and resulted in a few localized holes that were sufficient to permit blood to percolate through the textile wall. Some polyester yarns in the warp direction were ruptured. The Nitinol wire used in this device was shown to be corrosion resistant but the selection of the polypropylene suture was inappropriate. Because this technology is maturing rapidly, these weaknesses can be avoided in the future generations of endovascular devices. It is recommended that these Nitinol wires be sutured to the fabric and that polyester yarns stronger than 68 decitex in tubes 8 mm in diameter are selected.


Assuntos
Aneurisma Roto/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Idoso , Ligas , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Materiais Biocompatíveis , Análise de Falha de Equipamento , Evolução Fatal , Humanos , Masculino , Teste de Materiais , Microscopia Eletrônica de Varredura , Polipropilenos , Reoperação , Suturas , Tomografia Computadorizada por Raios X
18.
J Long Term Eff Med Implants ; 18(3): 205-25, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-20001893

RESUMO

A patient was fitted with an Anaconda stent graft for which there was a persistent type II endoleak. Two subsequent attempts at embolization were unable to resolve the endoleak. The diameter of the aneurysm varied initially from 5.5 cm in diameter down to 4.8 cm but then later re-dilated to 6.1 cm, with evidence of persistent flow into the aneurysmal sac from the inferior mesenteric artery. Results from serial computed tomography scans demonstrated clear evidence of a type II endoleak that originated from the inferior mesenteric artery with outflow to a distal lumbar artery. The harvested stent graft did not show evidence of a device-related failure. The stent graft and its modular segments were found to have been properly deployed. Only a thin external capsule was evident at explantation. The internal wall of the device showed irregular and thin encapsulation with scattered mural thrombi, which were more prominent at the bifurcation of the main body of the device. Blood deposits and tissue development were sufficient to prevent blood oozing through the wall. The explanted Anaconda stent graft was devoid of any construction flaws or damage (fatigue of the textile or corrosion of the Nitinol wires) after implantation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Hemorragia/etiologia , Stents/efeitos adversos , Ligas , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Materiais Biocompatíveis , Remoção de Dispositivo , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Polipropilenos , Suturas , Tomografia Computadorizada por Raios X
19.
Eur J Radiol ; 65(2): 316-25, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17499952

RESUMO

PURPOSE: To determine prospectively the safety and efficacy of the blood-pool contrast agent gadofosveset trisodium in renal artery magnetic resonance angiography (MRA). MATERIALS AND METHODS: Gadofosveset (0.03 mmol/kg) was administered to adult patients with known or suspected renal arterial disease in a multi-center phase 3 single dose study. The drug binds reversibly to albumin, prolonging the blood residence time, and allowing collection of images in the first-pass and steady-state phases. The combination of these images was compared to non-contrast MRA, using catheter X-ray angiography (XRA) as the standard of reference (SOR). All MRA images were collected at 1.5 T in one imaging session for direct comparison, and XRA within 30 days. Sensitivity, specificity, and accuracy for diagnosing significant disease (stenosis > or =50%) were calculated for MRA using three independent blinded readers. Patient safety was monitored for 72-96 h. RESULTS: A total of 145 patients at 18 centers were enrolled and received gadofosveset; the 127 with complete efficacy data entered the primary efficacy analysis. Gadofosveset-enhanced MRA led to significant improvement (p<0.01) in sensitivity (+25%, +26%, +42%), specificity (+23%, +25%, +29%), and accuracy (+23%, +28%, +29%) over non-enhanced MRA for the three readers. The rate of uninterpretable examinations decreased from 30% to less than 2%. There were no serious adverse events, and the most common adverse events were nausea, pruritus, and headache (8% each). No significant trends in clinical chemistry parameters, nor significant changes in serum creatinine, were found following administration of gadofosveset. CONCLUSION: In patients with known or suspected renal arterial disease, multi-phase gadofosveset-enhanced MRA significantly improves sensitivity, specificity, and accuracy versus non-enhanced MRA. Gadofosveset was safe and well tolerated in this patient population.


Assuntos
Gadolínio , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Obstrução da Artéria Renal/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas
20.
Med Image Comput Comput Assist Interv ; 10(Pt 2): 227-34, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18044573

RESUMO

Abdominal Aortic Aneurysm is a potentially life-threatening disease if not treated adequately. Its pathogenesis is complex and multifactorial and is still not fully understood. Many biochemical and biomechanical mechanisms have been identified as playing a role in the formation of aneurysms but it is as yet unclear what triggers the process. We investigated the role of the relevant biomechanical factors, in particular the wall shear stress and the intramural wall stress by simulating fluid structure interaction between the blood flow and the deforming arterial wall in a healthy abdominal aortic bifurcation, the preferred location of the disease. We then extended this study by introducing a hypothetical weakening of the aortic wall. Intramural wall stress was considerably higher and wall shear stress considerably lower in this configuration, supporting the hypothesis that biomechanical aneurysmal growth factors are self-sustaining.


Assuntos
Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Biofísica/métodos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Elasticidade , Análise de Elementos Finitos , Humanos , Valores de Referência , Resistência ao Cisalhamento , Estresse Mecânico