Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Prehosp Emerg Care ; 24(4): 515-524, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31287350

RESUMO

Objective: To use a previously published criterion standard to compare the accuracy of 4 different mass casualty triage systems (Sort, Assess, Lifesaving Interventions, Treatment/Transport [SALT], Simple Triage and Rapid Treatment [START], Triage Sieve, and CareFlight) when used in an emergency department-based adult population. Methods: We performed a prospective, observational study of a convenience sample of adults aged 18 years or older presenting to a single tertiary care hospital emergency department. A co-investigator with prior emergency medical services (EMS) experience observed each subject's initial triage in the emergency department and recorded all data points necessary to assign a triage category using each of the 4 mass casualty triage systems being studied. Subjects' medical records were reviewed after their discharge from the hospital to assign the "correct" triage category using the criterion standard. The 4 mass casualty triage system assignments were then compared to the "correct" assignment. Descriptive statistics were used to compare accuracy and over- and under-triage rates for each triage system. Results: A total of 125 subjects were included in the study. Of those, 53% were male and 59% were transported by private vehicle. When compared to the criterion standard definitions, SALT was found to have the highest accuracy rate (52%; 95% CI 43-60) compared to START (36%; 95% CI 28-44), CareFlight (36%; 95% CI 28-44), and TriageSieve (37%; 95% CI 28-45). SALT also had the lowest under-triage rate (26%; 95% CI 19-34) compared to START (57%; 95% CI 48-66), CareFlight (58%; 95% CI 49-66), and TriageSieve (58%; 95% CI 49-66). SALT had the highest over-triage rate (22%; 95% CI 14-29) compared to START (7%; 95% CI 3-12), CareFlight (6%; 95% CI 2-11) and TriageSieve (6%; 95% CI 2-11). Conclusion: We found that SALT triage most often correctly triaged adult emergency department patients when compared to a previously published criterion standard. While there are no target under- and over-triage rates that have been published for mass casualty triage, all 4 systems had relatively high rates of under-triage.


Assuntos
Planejamento em Desastres , Serviços Médicos de Emergência , Incidentes com Feridos em Massa , Triagem/normas , Adulto , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Estudos Prospectivos , Atenção Terciária à Saúde
2.
Prehosp Emerg Care ; 23(3): 304-308, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30196737

RESUMO

INTRODUCTION: It was previously difficult to compare the accuracy of different mass casualty triage systems to one another. This pilot study is one of the first attempts to operationalize an expert panel's criterion standard definitions of triage categories in a pediatric population in order to compare accuracy between different systems. OBJECTIVE: To compare the accuracy of 4 different mass casualty triage systems (SALT, JumpSTART, Triage Sieve, and CareFlight) when used for children. METHODS: We observed the emergency department triage of patients less than 18 years old presenting to the only pediatric specialty hospital/Level 1 trauma center in Milwaukee County, Wisconsin. A single, certified EMS provider observed each patient's initial triage in the emergency department and recorded all findings that were necessary to categorize the patient using each of the 4 mass casualty triage systems being studied. Hospital medical records were then reviewed for each patient and assigned a criterion standard triage category based on the treatments received and final disposition. Descriptive statistics were used to compare accuracy, over-, and under-triage rates for each of the triage systems. RESULTS: A total of 115 subjects were enrolled. Of those, 51% were male and 57% were transported by ambulance. When compared to the criterion standard definitions, SALT was found to have the highest accuracy rate (59%; 95% CI 50-68) compared to JumpSTART (57%; 95% CI 48-66), CareFlight (56%; 95% CI 47-65), and TriageSieve (56%; 95% CI 46-65). SALT also had the lowest under-triage rate (33%; 95% CI 24-42) compared to JumpSTART (39%; 95% CI 30-48), CareFlight (39%; 95% CI 30-48), and TriageSieve (39%; 95% CI 30-48). SALT had the highest over-triage rate (6%; 95% CI 2-11) compared to JumpSTART (4%; 95% CI 1-8), CareFlight (5%; 95% CI 1-9), and TriageSieve (5%; 95% CI 1-9). However, the confidence intervals for both the accuracy and under-triage rates overlapped between all triage systems. For each triage system, the most common error was designating a patient as "minimal" that, according to the criterion standard, should have been triaged as "delayed." CONCLUSION: We found that the 4 most popular mass casualty triage systems preformed similarly in an emergency department-based pediatric population. None of the systems were extremely accurate, and each demonstrated an unacceptable amount of under-triage. Better differentiating between patients categorized as "minimal" and "delayed" may improve the accuracy of mass casualty triage systems.


Assuntos
Serviços Médicos de Emergência , Hospitais Pediátricos , Incidentes com Feridos em Massa , Triagem/normas , Adolescente , Benchmarking , Certificação , Criança , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Incidentes com Feridos em Massa/estatística & dados numéricos , Prontuários Médicos , Projetos Piloto , Wisconsin
3.
Prehosp Emerg Care ; 19(2): 267-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25290529

RESUMO

INTRODUCTION: Accuracy and effectiveness analyses of mass casualty triage systems are limited because there are no gold standard definitions for each of the triage categories. Until there is agreement on which patients should be identified by each triage category, it will be impossible to calculate sensitivity and specificity or to compare accuracy between triage systems. OBJECTIVE: To develop a consensus-based, functional gold standard definition for each mass casualty triage category. METHODS: National experts were recruited through the lead investigators' contacts and their suggested contacts. Key informant interviews were conducted to develop a list of potential criteria for defining each triage category. Panelists were interviewed in order of their availability until redundancy of themes was achieved. Panelists were blinded to each other's responses during the interviews. A modified Delphi survey was developed with the potential criteria identified during the interview and delivered to all recruited experts. In the early rounds, panelists could add, remove, or modify criteria. In the final rounds edits were made to the criteria until at least 80% agreement was achieved. RESULTS: Thirteen national and local experts were recruited to participate in the project. Six interviews were conducted. Three rounds of voting were performed, with 12 panelists participating in the first round, 12 in the second round, and 13 in the third round. After the first two rounds, the criteria were modified according to respondent suggestions. In the final round, over 90% agreement was achieved for all but one criterion. A single e-mail vote was conducted on edits to the final criterion and consensus was achieved. CONCLUSION: A consensus-based, functional gold standard definition for each mass casualty triage category was developed. These gold standard definitions can be used to evaluate the accuracy of mass casualty triage systems after an actual incident, during training, or for research.


Assuntos
Planejamento em Desastres , Serviços Médicos de Emergência/normas , Incidentes com Feridos em Massa , Centros de Traumatologia/normas , Triagem/normas , Consenso , Humanos , Indicadores de Qualidade em Assistência à Saúde
4.
Virology ; 443(1): 113-22, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23725695

RESUMO

We previously discovered that nuclear import of low risk HPV11 E7 is mediated by its zinc-binding domain via a pathway that is independent of karyopherins/importins (Piccioli et al., 2010. Virology 407, 100-109). In this study we mapped and characterized a leucine-rich nuclear export signal (NES), 76IRQLQDLLL84, within the zinc-binding domain that mediates the nuclear export of HPV11 E7 in a CRM1-dependent manner. We also identified a mostly hydrophobic patch 65VRLVV69 within the zinc-binding domain that mediates nuclear import of HPV11 E7 via hydrophobic interactions with the FG-repeats domain of Nup62. Substitutions of hydrophobic residues to alanine within the 65VRLVV69 sequence disrupt the nuclear localization of 11E7, whereas the R66A mutation has no effect. Overall the data support a model of nuclear entry of HPV11 E7 protein via hydrophobic interactions with FG nucleoporins at the nuclear pore complex.


Assuntos
Transporte Ativo do Núcleo Celular , Papillomavirus Humano 11/fisiologia , Proteínas E7 de Papillomavirus/metabolismo , Sinais Direcionadores de Proteínas , Papillomavirus Humano 11/genética , Humanos , Carioferinas/metabolismo , Glicoproteínas de Membrana/metabolismo , Complexo de Proteínas Formadoras de Poros Nucleares/metabolismo , Proteínas E7 de Papillomavirus/genética , Receptores Citoplasmáticos e Nucleares/metabolismo , Proteína Exportina 1
5.
Virology ; 407(1): 100-9, 2010 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-20800258

RESUMO

We investigated the nuclear import of low risk HPV11 E7 protein using 1) transfection assays in HeLa cells with EGFP fusion plasmids containing 11E7 and its domains and 2) nuclear import assays in digitonin-permeabilized HeLa cells with GST fusion proteins containing 11E7 and its domains. The EGFP-11E7 and EGFP-11cE7(39-98) localized mostly to the nucleus. The GST-11E7 and GST-11cE7(39-98) were imported into the nuclei in the presence of either Ran-GDP or RanG19V-GTP mutant and in the absence of nuclear import receptors. This suggests that 11E7 enters the nucleus via a Ran-dependent pathway, independent of nuclear import receptors, mediated by a nuclear localization signal located in its C-terminal domain (cNLS). This cNLS contains the zinc binding domain consisting of two copies of Cys-X-X-Cys motif. Mutagenesis of Cys residues in these motifs changed the localization of the EGFP-11cE7/-11E7 mutants to cytoplasmic, suggesting that the zinc binding domain is essential for nuclear localization of 11E7.


Assuntos
Transporte Ativo do Núcleo Celular , Papillomavirus Humano 11/fisiologia , Proteínas Oncogênicas Virais/metabolismo , Replicação Viral , Motivos de Aminoácidos , Fusão Gênica Artificial , Sítios de Ligação , Núcleo Celular/química , Genes Reporter , Proteínas de Fluorescência Verde , Células HeLa , Humanos , Mutagênese Sítio-Dirigida , Estrutura Terciária de Proteína , Transfecção , Proteína ran de Ligação ao GTP/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...