Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Spat Spatiotemporal Epidemiol ; 50: 100675, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39181605

RESUMO

Spatial life course epidemiological approaches offer promise for prospectively examining the impacts of air pollution exposure on longer-term health outcomes, but existing research is limited. An essential aspect, often overlooked is the comprehensiveness of exposure data across the lifecourse. The primary objective was to meticulously reconstruct historical estimates of air pollution exposure to include prenatal exposure as well as annual exposure from birth to 10 years (1977-1987) for each cohort member. We linked these data from a birth cohort of 1,265 individuals, born in Aotearoa/New Zealand in mid-1977 and studied to age 40, to historical air pollution data to create estimates of exposure from birth to 10 years (1977-1987). Improvements in air quality over time were found. However, outcomes varied by demographic and socioeconomic factors. Future research should examine how inequitable air pollution exposure is related to health outcomes over the life course.


Assuntos
Poluição do Ar , Exposição Ambiental , Nova Zelândia/epidemiologia , Humanos , Poluição do Ar/efeitos adversos , Poluição do Ar/análise , Feminino , Masculino , Exposição Ambiental/efeitos adversos , Adulto , Gravidez , Coorte de Nascimento , Pré-Escolar , Lactente , Recém-Nascido , Estudos de Viabilidade , Criança , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , Estudos de Coortes , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/efeitos adversos , Adulto Jovem , Adolescente
2.
Child Abuse Negl ; 145: 106444, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37703676

RESUMO

BACKGROUND: Longitudinal studies consistently report adverse long-term outcomes of childhood maltreatment. Little is known about the impact of childhood maltreatment on mental health among a marginalized population (New Zealand Maori); therefore, we cannot assume the effects of maltreatment are the same across the population. OBJECTIVE: Associations were examined between childhood sexual abuse (CSA), childhood physical punishment (CPP) and childhood neglect (CN) (<16 years) and mental health outcomes 18-40 years, by ethnicity (Maori/non-Maori). PARTICIPANTS AND SETTING: Data from the Christchurch Health and Development Study, a study of a birth cohort of 1265 children born in Christchurch in 1977. By age 40, 17.8 % (n = 191) reported New Zealand Maori ethnic identity; 82.2 % (n = 883) were non-Maori. METHODS: CSA, CPP (<16 years) were measured at 18, 21 years; CN was measured at 40 years. Major depression, anxiety disorder, suicidal ideation, alcohol abuse/dependence and cannabis abuse/dependence were measured at ages 21, 25, 30, 35 and 40 years. Childhood confounding variables controlled. Analyses were extended to include Maori ethnicity. RESULTS: After statistical adjustment, experience of severe childhood maltreatment increased odds of mental health problems 1.8-2.6×, compared to no maltreatment; the effects of maltreatment were similar for males and females. For Maori, some higher rates of mental health problems were seen among those maltreated, no statistically significant associations were detected after Bonferroni correction (among severe maltreatment vs. no maltreatment). Limitations should be considered when interpreting results. CONCLUSIONS: Exposure to childhood maltreatment has long-term effects into middle-age. Further research employing culturally-sensitive approaches may help clarify Maori childhood maltreatment outcomes.


Assuntos
Alcoolismo , Maus-Tratos Infantis , Transtorno Depressivo Maior , Feminino , Masculino , Pessoa de Meia-Idade , Humanos , Criança , Etnicidade , Estudos Longitudinais , Nova Zelândia/epidemiologia , Avaliação de Resultados em Cuidados de Saúde
3.
Anaesthesia ; 78(6): 739-746, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37010989

RESUMO

Virtual reality is a form of high-fidelity simulation that may be used to enhance the quality of medical education. We created a bespoke virtual reality trainer software using high resolution motion capture and ultrasound imagery to teach cognitive-motor needling skills necessary for the performance of ultrasound-guided regional anaesthesia. The primary objective of this study was to determine the construct validity between novice and experienced regional anaesthetists. Secondary objectives were: to create learning curves for needling performance; compare the virtual environment immersion with other high-fidelity virtual reality software; and compare cognitive task loads imposed by the virtual trainer compared with real-life medical procedures. We recruited 21 novice and 15 experienced participants, each of whom performed 40 needling attempts on four different virtual nerve targets. Performance scores for each attempt were calculated based on measured metrics (needle angulation, withdrawals, time taken) and compared between the groups. The degree of virtual reality immersion was measured using the Presence Questionnaire, and cognitive burden was measured using the NASA-Task Load Index. Scores by experienced participants were significantly higher than novices (p = 0.002) and for each nerve target (84% vs. 77%, p = 0.002; 86% vs. 79%, p = 0.003; 87% vs. 81%, p = 0.002; 87% vs. 80%, p = 0.003). Log-log transformed learning curves demonstrated individual variability in performance over time. The virtual reality trainer was rated as being comparably immersive to other high-fidelity virtual reality software in the realism, possibility to act and quality of interface subscales (all p > 0.06) but not in the possibility to examine and self-performance subscales (all p < 0.009). The virtual reality trainer created workloads similar to those reported in real-life procedural medicine (p = 0.53). This study achieved initial validation of our new virtual reality trainer and allows progression to a planned definitive trial that will compare the effectiveness of virtual reality training on real-life regional anaesthesia performance.


Assuntos
Laparoscopia , Realidade Virtual , Humanos , Competência Clínica , Simulação por Computador , Software , Ultrassonografia de Intervenção , Interface Usuário-Computador
4.
Scott Med J ; 67(4): 189-195, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35818757

RESUMO

BACKGROUND AND AIMS: Bystanders should be protected against aerosols, droplets, saliva, blood and vomitus during resuscitation after cardiac arrest The SARUS (safer - airway - resuscitation) CPR airway hood™ is a clear plastic cover and integrated mask that envelopes the head and torso. Our objectives were to test leakage using saline aerosol generation tests, then assess the performance of the hood during mock cardio-pulmonary resuscitation on a manikin. METHODS: A checklist was validated by comparing the performance of 10 novices against 10 experts during mock resuscitation. Thereafter, 15 novices were tested with and without the hood, in a randomised cross-over study, one week apart. RESULTS: Laboratory analysis showed a > 99% reduction of saline particles detected 5 cm, 75 cm and 165 cm above volunteers wearing the hood. On manikins, experts scored better compared to novices, 8.5 (0.7) vs 7.6 (1.2), difference (95%CI) 0.9 (0.4-1.3), P = 0.0004. Novice performance was equivalent using the hood and standard equipment, 7.3 (1.4) vs 7.3 (1.1) respectively, difference (90%CI) 0.0 (-0.3 - 0.3), P = 0.90. CONCLUSION: Aerosol transmission reduced in the breathing zone. Simulated resuscitation by novices was equivalent with and without the hood.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Humanos , Estudos Cross-Over , Manequins , Aerossóis
5.
Climacteric ; 25(3): 271-277, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34269148

RESUMO

BACKGROUND: There is little current research on the transition to natural menopause among contemporary groups of mid-life women at age 40 years. OBJECTIVE: This study reports on female members of the Christchurch Health and Development Study cohort. This research aimed to: document the menopause status, reproductive outcomes and climacteric symptoms of the women at age 40 years; examine the associations between menopause status and concurrent measures of psychosocial and economic well-being; and document the associations between menopause status and potential predictors of menopause reflecting childhood, family and individual factors prior to age 40 years. METHODS: The Christchurch Health and Development Study is a longitudinal, representative, prospective cohort of 1265 babies (630 females) born in New Zealand in 1977. At age 40 years, 470 women (who had not experienced surgical menopause) were interviewed on their menopause status, climacteric symptoms and associated factors. RESULTS: The majority of women were premenopausal, around 20% were perimenopausal and 2% were postmenopausal. Statistically significant associations were found reflecting higher rates of diagnosed reproductive disorder, climacteric symptoms, low occupational status, non-heterosexual sexuality and exposure to childhood sexual abuse amongst both perimenopausal and postmenopausal women at age 40 years. CONCLUSION: These data will inform directions for future data collection and analyses.


Assuntos
Coorte de Nascimento , Climatério , Adulto , Criança , Climatério/psicologia , Feminino , Humanos , Masculino , Menopausa/psicologia , Nova Zelândia/epidemiologia , Perimenopausa , Estudos Prospectivos
6.
Anaesthesia ; 76 Suppl 1: 160-170, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33426657

RESUMO

The accuracy and reliability of ultrasound are still insufficient to guarantee complete and safe nerve block for all patients. Injection of local anaesthetic close to, but not touching, the nerve is key to outcomes, but the exact relationship between the needle tip and nerve epineurium is difficult to evaluate, even with ultrasound. Ultrasound has insufficient resolution, tissues are difficult to discern due to acoustic impedance and needles are more difficult to see with increased angulation. The limitations of ultrasound have shifted the focus of innovation towards bio-markers that help detect needle tip position by utilising the physical properties of tissues, (e.g. pressure, electrical, optics, acoustic and elastic). Although most are at the laboratory stage and results are as yet only available from phantom or cadaver studies, clinical trials are imminent. For example, fine optical fibres placed within the lumen of block needles can measure needle tip pressure. Electrical impedance differentiates between intraneural and perineural needle tip placement. A new tip tracker needle has a piezo element embedded at its distal end that tracks the needle tip in-plane and out-of-plane as a blue/red or green circle depending on its relative location within the beam. Micro-ultrasound at the tip of the needle is in development. Early images using 40MHz in anaesthetised pigs reveal muscle striation, distinct epineurium and 30-40 fascicles > 75 micron in diameter. The next few years will see a technological revolution in tip-tracking technology that has the potential to improve patient safety and, in doing so, change practice.


Assuntos
Bloqueio Nervoso/métodos , Nervos Periféricos/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Anestésicos Locais/administração & dosagem , Animais , Agulhas
7.
Anaesthesia ; 76 Suppl 1: 171-181, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33426667

RESUMO

The current fourth industrial revolution is a distinct technological era characterised by the blurring of physics, computing and biology. The driver of change is data, powered by artificial intelligence. The UK National Health Service Topol Report embraced this digital revolution and emphasised the importance of artificial intelligence to the health service. Application of artificial intelligence within regional anaesthesia, however, remains limited. An example of the use of a convoluted neural network applied to visual detection of nerves on ultrasound images is described. New technologies that may impact on regional anaesthesia include robotics and artificial sensing. Robotics in anaesthesia falls into three categories. The first, used commonly, is pharmaceutical, typified by target-controlled anaesthesia using electroencephalography within a feedback loop. Other types include mechanical robots that provide precision and dexterity better than humans, and cognitive robots that act as decision support systems. It is likely that the latter technology will expand considerably over the next decades and provide an autopilot for anaesthesia. Technical robotics will focus on the development of accurate sensors for training that incorporate visual and motion metrics. These will be incorporated into augmented reality and visual reality environments that will provide training at home or the office on life-like simulators. Real-time feedback will be offered that stimulates and rewards performance. In discussing the scope, applications, limitations and barriers to adoption of these technologies, we aimed to stimulate discussion towards a framework for the optimal application of current and emerging technologies in regional anaesthesia.


Assuntos
Anestesia por Condução/métodos , Inteligência Artificial , Robótica
8.
Anaesthesia ; 76(2): 209-217, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32797700

RESUMO

In this study, we measured the performance of medical students and anaesthetists using a new tracker needle during simulated sciatic nerve block on soft embalmed cadavers. The tracker needle incorporates a piezo element near its tip that generates an electrical signal in response to insonation. A circle, superimposed on the ultrasound image surrounding the needle tip, changes size and colour according to the position of the piezo element within the ultrasound beam. Our primary objective was to compare sciatic block performance with the tracker switched on and off. Our secondary objectives were to record psychometrics, procedure efficiency, participant self-regulation and focused attention using eye-tracking technology. Our primary outcome measures were the number of steps successfully performed and the number of errors committed during each block. Videos were scored by trained experts using validated checklists. Sequential tracker activation and deactivation was randomised equally within subjects. With needle activation, steps improved in 10 (25%) subjects and errors reduced in six (15%) subjects. The most important steps were: needle tip identification before injection, OR (95%CI) 2.12 (1.61-2.80; p < 0.001); and needle tip identification before advance of the needle, 1.80 (1.36-2.39; p < 0.001). The most important errors were: failure to identify the needle tip before injection, 2.40 (1.78-3.24; p < 0.001); and failure to quickly regain needle tip position when tip visibility was lost, 2.03 (1.5-2.75; p < 0.001). In conclusion, needle-tracking technology improved performance in a quarter of subjects.


Assuntos
Agulhas , Bloqueio Nervoso/métodos , Nervo Isquiático/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adulto , Anestesiologia/educação , Anestesistas , Atenção , Cadáver , Competência Clínica , Embalsamamento , Feminino , Humanos , Masculino , Psicometria , Adulto Jovem
9.
Anaesthesia ; 75(1): 80-88, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31506921

RESUMO

Visibility of the needle tip is difficult to maintain during ultrasound-guided nerve block. A new needle has been developed that incorporates a piezo element 2-2.3 mm from the tip, activated by ultrasound. The electrical signal manifests as a coloured circle surrounding the needle tip, and allows real-time tracking. We hypothesised that novice regional anaesthetists would perform nerve block better with the tracker turned on rather than off. Our primary objective was to evaluate the new needle by measuring the performance of novice anaesthetists conducting simulated sciatic block on the soft embalmed Thiel cadaver. Training consisted of a lecture, scanning in volunteers and practice on cadavers. Testing entailed scanning the sciatic nerve of a cadaver and conducting 20 in-plane sciatic blocks in the mid-to-upper thigh region. Subjects were randomised equally, in groups of five, according to the sequence: tracker on/off/on/off; or tracker off/on/off/on. Video recordings were assessed by six raters for steps performed correctly and errors committed. Eight subjects were recruited and 160 videos were analysed. Using the tracking needle, five correct steps improved and one error reduced. The benefits included: better identification of the needle tip before advancing the needle, OR (95%CI) 3.4 (1.6-7.7; p < 0.001); better alignment of the needle to the transducer, 3.1 (1.3-8.7; p = 0.009); and better visibility of the needle tip 3.0 (1.4-7.3; p = 0.005). In conclusion, use of the tracker needle improved the sciatic block performance of novices on the soft embalmed cadaver.


Assuntos
Anestesia por Condução/instrumentação , Agulhas , Bloqueio Nervoso/instrumentação , Nervo Isquiático , Ultrassonografia de Intervenção/métodos , Anestesia por Condução/métodos , Cadáver , Humanos , Bloqueio Nervoso/métodos
10.
BJA Educ ; 20(2): 34-41, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33456928
11.
BJA Educ ; 20(4): 140, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33465173

RESUMO

[This corrects the article DOI: 10.1016/j.bjae.2019.10.002.].

13.
Can Prosthet Orthot J ; 2(2): 33489, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-37614768

RESUMO

The Canadian healthcare system serves as an example of equity and federal service to citizens across the world. However, it is not without its challenges. Prosthetic coverage across Canada is highly variable and largely unable to provide equal coverage for Canadian persons living with amputation. Many persons with limb loss are forced to rely upon personal resources, fundraising, or the charity of non-governmental organizations in order to meet this basic healthcare need. This disparity in the Canadian healthcare system is unusual and largely undescribed in the literature. We thus explore the nature of Canadian healthcare prosthetic coverage across Canada, investigating the variability in coverage, presence of prosthetic coverage policies, clarity of policy, eligibility criteria, and interval of prosthetic replacement. Our findings highlight potential areas for improvement within current Canadian healthcare policy.

14.
Br J Anaesth ; 120(4): 854-859, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29576126

RESUMO

BACKGROUND: Errors may occur during regional anaesthesia whilst searching for nerves, needle tips, and test doses. Poor visual search impacts on decision making, clinical intervention, and patient safety. METHODS: We conducted a randomised single-blind study in a single university hospital. Twenty trainees and two consultants examined the paired B-mode and fused B-mode and elastography video recordings of 24 interscalene and 24 femoral blocks conducted on two soft embalmed cadavers. Perineural injection was randomised equally to 0.25, 0.5, and 1.0 ml volumes. Tissue displacement perceived on both imaging modalities was defined as 'target' or 'distractor'. Our primary objective was to test the anaesthetists' perception of the number and proportion of targets and distractors on B-mode and fused elastography videos collected during femoral and sciatic nerve block on soft embalmed cadavers. Our secondary objectives were to determine the differences between novices and experts, and between test-dose volumes, and to measure the area and brightness of spread and strain patterns. RESULTS: All anaesthetists recognised perineural spread using 0.25 ml volumes. Distractor patterns were recognised in 133 (12%) of B-mode and in 403 (38%) of fused B-mode and elastography patterns; P<0.001. With elastography, novice recognition improved from 12 to 37% (P<0.001), and consultant recognition increased from 24 to 53%; P<0.001. Distractor recognition improved from 8 to 31% using 0.25 ml volumes (P<0.001), and from 15 to 45% using 1 ml volumes (P<0.001). CONCLUSIONS: Visual search improved with fusion elastography, increased volume, and consultants. A need exists to investigate image search strategies.


Assuntos
Anestesistas/estatística & dados numéricos , Competência Clínica/estatística & dados numéricos , Bloqueio Nervoso/métodos , Ultrassonografia de Intervenção , Percepção Visual , Cadáver , Nervo Femoral , Humanos , Método Simples-Cego
15.
Anaesthesia ; 72(2): 190-196, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27897312

RESUMO

Despite widespread use of ultrasound imaging to guide needle placement, the incidence of transient and permanent nerve damage as a complication of regional anaesthesia has not changed over the last decade. In view of the controversy surrounding intraneural injection there is a need to understand the structural changes caused by subepineural and subperineural needle penetration. Clinical ultrasound machines do not provide adequate anatomical resolution, and anaesthetists have difficulty judging the precise location of the needle tip relative to the epineurium. We studied the suitability of micro-ultrasound imaging (which offers anatomical resolution better than 100 µm) as a tool for viewing neural anatomy and deformation caused by needle insertion. The primary objective was to assess micro-ultrasound imaging as a method to view fascicles within nerves resected from fresh and soft-embalmed cadavers. Secondary objectives were to observe any disruption of the neural anatomy caused by anaesthetic needle penetration, and to assess the integrity of fresh and Thiel method soft-embalmed nerves, after handling and during needle insertion using ultrasound images and histology. We imaged nine nerves from the left and right sides of fresh and soft-embalmed cadavers. A regional block needle was inserted into three median nerves. We identified fascicles > 0.4 mm in width using micro-ultrasound. Subepineural needle placement was associated with denting, rotation and elastic deformation of fascicles, whereas subperineural needle insertion split fascicles permanently.


Assuntos
Bloqueio Nervoso/métodos , Nervos Periféricos/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Cadáver , Estudos de Viabilidade , Humanos , Agulhas , Nervos Periféricos/anatomia & histologia
16.
Br J Anaesth ; 117(6): 792-800, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27956678

RESUMO

BACKGROUND: The incidence of intraneural injection during trainee anaesthetist ultrasound guided nerve block varies between 16% in experts and up to 35% in trainees. We hypothesized that elastography, an ultrasound-based technology that presents colour images of tissue strain, had the potential to improve trainee diagnosis of intraneural injection during UGRA, when integrated with B-Mode ultrasound onto a single image. METHODS: We recorded 40 median nerve blocks randomly allocated to 0.25 ml, 0.5 ml, 1 ml volumes to five sites, on both arms of two soft embalmed cadavers, using a dedicated B-Mode ultrasound and elastography transducer. We wrote software to fuse elastogram and B-Mode videos, then asked 20 trainee anaesthetists whether injection was intraneural or extraneural when seeing B-Mode videos, adjacent B-Mode and elastogram videos, fusion elastography videos or repeated B-Mode ultrasound videos. RESULTS: Fusion elastography improved the diagnosis of intraneural injection compared with B-Mode ultrasound, Diagnostic Odds Ratio (DOR) (95%CI) 21.7 (14.5 - 33.3) vs DOR 7.4 (5.2 - 10.6), P < 0.001. Compared with extraneural injection, intraneural injection was identified on fusion elastography as a distinct, brighter translucent image, geometric ratio 0.33 (95%CI: 0.16 - 0.49) P < 0.001. Fusion elastography was associated with greater trainee diagnostic confidence, OR (95%CI) 1.89 (1.69 - 2.11), P < 0.001, and an improvement in reliability, Kappa 0.60 (0.55 - 0.66). CONCLUSIONS: Fusion elastography improved the accuracy, reliability and confidence of trainee anaesthetist diagnosis of intraneural injection.


Assuntos
Anestesistas/educação , Anestesistas/estatística & dados numéricos , Competência Clínica/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/métodos , Nervo Mediano/diagnóstico por imagem , Bloqueio Nervoso/métodos , Ultrassonografia de Intervenção/métodos , Cadáver , Humanos , Nervo Mediano/efeitos dos fármacos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Br J Anaesth ; 117(3): 387-94, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27543534

RESUMO

BACKGROUND: Posterior variants of abdominal wall block include the quadratus lumborum type I, quadratus lumborum type II and quadratus lumborum transmuscular blocks. Our objectives were to compare the spread of injectate and nerve involvement, after conducting blocks using ultrasound guidance in soft embalmed cadavers. METHODS: After randomization, an experienced anaesthetist conducted three quadratus lumborum 1, three quadratus lumborum 2 and four transmuscular blocks on the left or right sides of five cadavers. All cadavers were placed in the lateral position and the quadratus lumborum muscle seen using a 3-9 MHz ultrasound probe placed in the flank. For each block, a 20 ml mixture of 17.75 ml water, 2 mls latex and 0.25 ml India ink was injected. The lumbar region and abdominal flank were dissected 72 h later. RESULTS: We conducted 10 blocks. Two quadratus lumborum 1 and two quadratus lumborum 2 blocks were associated with spread of dye within the TAP plane. One quadratus lumborum 1 block spread to the deep muscles of the back and one quadratus lumborum 2 block dispersed within the subcutaneous tissue surrounding the abdominal flank. All transmuscular quadratus lumborum blocks spread consistently to L1 and L3 nerve roots and within psoas major and quadratus lumborum muscles. CONCLUSIONS: Consistent spread to lumbar nerve roots was achieved using the transmuscular approach through the quadratus lumborum.


Assuntos
Parede Abdominal/inervação , Bloqueio Nervoso , Cadáver , Corantes , Humanos
18.
Br J Anaesth ; 116(5): 699-707, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27106974

RESUMO

BACKGROUND: We evaluated the physical properties and functional alignment of the soft-embalmed Thiel cadaver as follows: by assessing tissue visibility; by measuring its acoustic, mechanical and elastic properties; by evaluating its durability in response to repeated injection; and by aligning images with humans. METHODS: In four soft-embalmed Thiel cadavers, we conducted three independent studies. We assessed the following factors: (i) soft tissue visibility in a single cadaver for 28 weeks after embalming; (ii) the displacement of tissues in response to 1 and 5 ml interscalene and femoral nerve blocks in a single cadaver; and (iii) the stiffness of nerves and perineural tissue in two cadavers. We aligned our findings with ultrasound images from three patients and one volunteer. Durability was qualified by assessing B-mode images from repetitive injections during supervised training. RESULTS: There was no difference in visibility of nerves between 2 and 28 weeks after embalming {geometric mean ratio 1.13 [95% confidence interval (CI): 0.75-1.68], P=1.0}. Mean tissue displacement was similar for cadaver femoral and interscalene blocks [geometric mean ratio 1.02 (95% CI: 0.59-1.78), P=0.86], and for 1 and 5 ml injection volumes [geometric mean ratio 0.84 (95% CI: 0.70-1.01), P=0.19]. Cadavers had higher intraneural than extraneural stiffness [Young's modulus; geometric mean ratio 3.05 (95% CI: 2.98-3.12), P<0.001] and minimal distortion of anatomy when conducting 934 left-sided interscalene blocks on the same cadaver throughout a 10 day period. CONCLUSIONS: The soft-embalmed Thiel cadaver is a highly durable simulator that has excellent physical and functional properties that allow repeated injection for intensive ultrasound-guided regional anaesthesia training.


Assuntos
Anestesia por Condução/métodos , Anestesiologia/educação , Educação de Pós-Graduação em Medicina/métodos , Embalsamamento/métodos , Ultrassonografia de Intervenção/métodos , Cadáver , Técnicas de Imagem por Elasticidade/métodos , Humanos , Teste de Materiais/métodos , Materiais de Ensino
19.
Psychol Med ; 46(7): 1401-12, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26818194

RESUMO

BACKGROUND: There is limited information on long-term outcomes of adolescent depression. This study examines the associations between severity of depression in adolescence and a broad array of adult functional outcomes. METHOD: Data were gathered as part of the Christchurch Health and Development Study, a 35-year longitudinal study of a birth cohort of 1265 children born in Christchurch, New Zealand in 1977. Severity of depression at age 14-16 years was classified into three levels according to DSM symptom criteria for major depression (no depression/sub-threshold symptoms/major depression). This classification was related to adult functional outcomes assessed at ages 30 and 35 years using a generalized estimating equation modeling approach. Outcome measures spanned domains of mental disorder, education/economic circumstances, family circumstances and partner relationships. RESULTS: There were modest but statistically significant bivariate associations between adolescent depression severity and most outcomes. After covariate adjustment there remained weak but significant (p < 0.05) associations with rates of major depression, anxiety disorder, illicit substance abuse/dependence, any mental health problem and intimate partner violence (IPV) victimization. Estimates of attributable risk for these outcomes ranged from 3.8% to 7.8%. For two outcomes there were significant (p < 0.006) gender interactions such that depression severity was significantly related to increased rates of unplanned pregnancy and IPV victimization for females but not for males. CONCLUSIONS: The findings reinforce the importance of the individual/family context in which adolescent depression occurs. When contextual factors and probable maturational effects are taken into account the direct effects of adolescent depression on functioning in mature adulthood appear to be very modest.


Assuntos
Desenvolvimento do Adolescente , Transtornos de Ansiedade/epidemiologia , Vítimas de Crime/estatística & dados numéricos , Transtorno Depressivo Maior/epidemiologia , Índice de Gravidade de Doença , Maus-Tratos Conjugais/estatística & dados numéricos , Adolescente , Adulto , Feminino , Humanos , Estudos Longitudinais , Masculino , Nova Zelândia/epidemiologia , Risco , Transtornos Relacionados ao Uso de Substâncias
20.
Anaesthesia ; 70(11): 1281-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26336853

RESUMO

We compared the McGrath MAC(®) videolaryngoscope when used as both a direct and an indirect laryngoscope with a standard Macintosh laryngoscope in patients without predictors of a difficult tracheal intubation. We found higher median Intubation Difficulty Scores with the McGrath MAC as a direct laryngoscope, 1 (0-3 [0-5]) than when using it as an indirect videolaryngoscope, 0 (0-1 [0-5]) or when using the Macintosh laryngoscope, 0 (0-1 [0-5]), p = 0.04. This was mirrored in the subjective user reporting, scored out of 10, of difficulty for each method 3.0 (2.0-3.4 [0.5-80]); 2.0 (1.0-3.9 [0-70]) and 2.0 (1.0-3.3 [0-70]), respectively (p = 0.01). This difficulty is in part explained by the poorer laryngeal views recorded using the Cormack and Lehane classification system (p < 0.001) and reflected in the higher than normal operator force required (25%, 4%, 8% for each method, respectively, p < 0.001) and the increased use of rigid intubation aids (21%, 6%, 2%, respectively, p < 0.001). There was no difference between the groups in time taken to intubate or incidence of complications. There was no statistical difference in the performances as measured between the McGrath MAC used as an indirect videolaryngoscope and the Macintosh laryngoscope. We cannot recommend that the McGrath videolaryngoscope be used as a direct laryngscopic device in place of the Macintosh.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Gravação em Vídeo/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA