Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Bone Joint Res ; 8(10): 443-450, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31728182

RESUMO

OBJECTIVES: Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated. METHODS: This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (sd 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival. RESULTS: There was no loss to follow-up and no actual or impending revision or reoperation. Median OHS increased from 24 (interquartile range (IQR) 20 to 28) preoperatively to 48 (IQR 46 to 48) at the latest follow-up (48 being the best possible score). Radiographs showed one patient had a head-neck junction lucency. No other radiolucency, osteolysis, component migration, or femoral neck thinning was noted. CONCLUSION: The results in this small consecutive cohort suggest that metal-on-monobloc-XLPE HRA is successful in the short term and merits further investigation as a conservative alternative to the current accepted standard of stemmed THA. However, we would stress that survival data with longer-term follow-up are needed prior to widespread adoption.Cite this article: R. B. C. Treacy, J. P. Holland, J. Daniel, H. Ziaee, D. J. W. McMinn. Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing. Bone Joint Res 2019;8:443-450. DOI: 10.1302/2046-3758.810.BJR-2019-0060.R1.

2.
J Arthroplasty ; 30(3): 416-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25453631

RESUMO

We report the early failure of five ceramic-on-ceramic hip resurfacings (CoCHRs). The ceramic used for the acetabular liner was a novel ceramic-composite (two thirds polyurethane and one third alumina ceramic). All cases were revised for increasing metal ion levels (blood cobalt 3.93-208.0 µg/l and chromium 1.57-17.5 µg/l) due to ceramic liner fracture and/or accelerated wear of the ceramic femoral head coating. Patients underwent bearing exchange and revision using primary hip arthroplasty implants at a mean of 3.0 years following CoCHR. Intraoperatively all patients had metallosis. At 1 to 2 years of follow-up blood metal ions normalized with no complications. We do not recommend this particular type of ceramic-on-ceramic bearing for hip resurfacing.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Adulto , Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis , Cerâmica , Cromo/sangue , Cobalto/sangue , Corrosão , Feminino , Intoxicação por Metais Pesados , Humanos , Metais Pesados/sangue , Pessoa de Meia-Idade , Intoxicação/sangue , Intoxicação/etiologia
3.
Hip Int ; 24(4): 355-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24817401

RESUMO

During the first decade of the 21st century, metal-on-metal hip resurfacing became one of the main treatment options for younger, more active patients with osteoarthritis. However, as a result of the reported failure rate of both total hip replacement (THR) and resurfacing in patients with considerable loss of bone stock in the femoral head (e.g., in extensive avascular necrosis), other solutions have been sought for these patients. The short-stemmed Birmingham Mid Head Resection prosthesis (BMHR) combines a metal-on-metal articulation and a femoral neck preserving feature. In this study, radiostereometric analysis (RSA) was used to study migration of the BMHR femoral component in 13 hips. Translations and rotations were measured up to two years. Relative values showed no statistically significant migration. Absolute values demonstrated settling in occurring between zero and two months postoperatively in all directions studied. From two months to two years no significant migration occurred except for rotation around the x-axis of the femoral segment (p = 0.049). After initial settling-in, absolute values were low, indicating that there was no evidence of early migration or loosening of the components.


Assuntos
Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Análise Radioestereométrica/métodos , Adulto , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento
4.
Clin Orthop Relat Res ; 469(6): 1651-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21108029

RESUMO

BACKGROUND: Metal ions released from arthroplasty devices are largely cleared in urine, leading to high exposure in renal tissues. Validated early markers of renal damage are routinely used to monitor workers in heavy metal industries, and renal risk can be quantified in these industries. It is unclear if the ion levels in patients with metal-on-metal hips are sufficient to cause renal damage. QUESTION: Does metal-on-metal (MOM) bearing use over a 10-year period lead to elevation of early renal markers compared with the levels expected in subjects with no metal exposure? METHODS: We retrospectively reviewed 31 patients who underwent MOM hip resurfacings 10 years earlier. Whole blood specimens were collected for metal ion analysis, serum for creatinine estimation, and urine for timed metal ion output and renal markers. The renal marker levels of 30 age- and gender-matched subjects with no metal exposure and no known renal problems or diabetes mellitus were used as controls for renal markers. RESULTS: Median serum creatinine level in the MOM group was 1.1 mg/dL (interquartile range, 1.0-1.2 mg/dL) and median creatinine clearance was 79.2 mL/min. In this cohort, the number of patients with markers of renal damage above the reference range was comparable to the controls. None of the renal markers were associated with metal levels. CONCLUSION: The absence of elevation of renal markers in this cohort 10 years after MOM bearing implantation is reassuring. However, we believe surveillance through further longer-term, large-scale controlled trials are needed to monitor this arthroplasty-induced low-intensity (but long-term) trace element exposure to rule out potential nephrotoxicity.


Assuntos
Artroplastia de Quadril/efeitos adversos , Biomarcadores/sangue , Prótese de Quadril/efeitos adversos , Metais/sangue , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Insuficiência Renal/induzido quimicamente , Adulto , Idoso , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Metais/efeitos adversos , Pessoa de Meia-Idade , Osteoartrite do Quadril/sangue , Falha de Prótese , Insuficiência Renal/sangue , Estudos Retrospectivos , Fatores de Tempo
5.
Clin Orthop Relat Res ; 469(6): 1589-97, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21161734

RESUMO

BACKGROUND: High medium-term survivorship of hip resurfacing arthroplasty in young patients has led to its increased usage. To achieve high survival rates, selecting patients with appropriate proximal femoral morphology and bone quality is important. For patients with poor bone quality or abnormal morphology, the mid-head resection technique is an alternative, bone-conserving procedure but whether this technique results in acceptable complications and survival is unknown. QUESTIONS/PURPOSES: We therefore assessed (1) implant survivorship of a mid-head resection device during short- and medium-term followup, (2) hip function, (3) adverse radiographic features emphasizing proximal stress shielding, and (4) complications. METHODS: We retrospectively reviewed 164 patients (171 hips) who underwent reconstruction with the Birmingham Mid-Head Resection device (Smith and Nephew Orthopaedics Ltd, Warwick, UK) between 2003 and 2008. Patients were reviewed with hip outcome questionnaires, clinical examination, and radiographs. We report findings in 156 of these 171 hips with a minimum followup of 2 years (mean, 3.5 years, range, 2-7.5 years). They include three successive iterations based on the same design rationale. RESULTS: There were four revisions during this period, including two femoral failures, giving 3.5-year survivorships of 97.4% and 98.7% with revision or reoperation for any reason and femoral failure as the end points, respectively. No patient is currently awaiting revision. Average hip function was 98%, as assessed by Oxford hip score. Five of the 87 intermediate-iteration (V1) stems showed proximal femoral stress shielding, a phenomenon not observed in the other two iterations. Four patients had asymptomatic below-knee deep venous thrombosis and one had nonfatal pulmonary embolism, all of which resolved uneventfully. CONCLUSIONS: The mid-head resection technique can circumvent the need for a more invasive procedure such as standard THA in patients who would benefit from a conservative arthroplasty but do not possess good femoral head bone quality or morphology.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Reoperação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/etiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
J Bone Joint Surg Am ; 92(4): 840-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20360506

RESUMO

BACKGROUND: A concern regarding the use of metal-on-metal bearings in hip arthroplasty has been that the high levels of metal ions that are released overwhelm the renal threshold for metal excretion, leading to systemic buildup of metals. The purpose of this investigation was to determine if the physiological renal capacity for cobalt clearance and cobalt concentrating efficiency is overwhelmed by the elevation in metal ion levels seen in patients with metal-on-metal-bearing hip devices. METHODS: Concurrent specimens of urine and plasma were obtained from a group of 461 patients (346 men and 115 women) at various intervals after either a unilateral (296) or a bilateral (130) metal-on-metal hip arthroplasty or preoperatively (thirty-five patients; the control specimens). Metal ion analyses were performed with high-resolution inductively coupled mass spectrometry. Renal efficiency was measured as the ratio of urine cobalt concentration to plasma cobalt concentration. Cobalt clearance was calculated by dividing the urine cobalt output in twenty-four hours by the plasma cobalt concentration. Dividing the quotient by 1440 adjusts it to clearance per minute. RESULTS: The median renal efficiency was found to be 0.9 in the analysis of the preoperative specimens, indicating that there was renal conservation of cobalt. In patients with metal-on-metal bearings, the median renal efficiency was 3.2, indicating that, as a result of cobalt excretion, the cobalt concentration in urine was threefold higher than the concentration in plasma. Linear regression analysis showed that renal efficiency progressively increased at a rate of 9% for every microg/24 hr increase in cobalt release. Cobalt clearance showed a similar trend, increasing from 1.3 mL/min in the preoperative group to 3.7 mL/min in the follow-up group. In the follow-up group, renal cobalt clearance progressively increased from 1.9 to 7.1 mL/min with increasing daily cobalt output, which indicates that with increasing in vivo metal ion release there was a progressive increase in the rate at which the kidneys cleared the plasma of cobalt. CONCLUSIONS: In subjects with no prosthetic device, the kidneys tend to conserve cobalt in the body. We found that, in patients with a metal-on-metal hip prosthesis, there is a progressive increase in cobalt clearance with increasing in vivo wear at the levels of cobalt release expected in patients with an array of metal-on-metal-bearing total joint arthroplasties. We found no threshold beyond which renal capacity to excrete these ions is overwhelmed.


Assuntos
Artroplastia de Quadril , Cobalto/farmacocinética , Prótese de Quadril , Rim/fisiologia , Adulto , Idoso , Feminino , Humanos , Capacidade de Concentração Renal , Masculino , Metais , Pessoa de Meia-Idade
7.
Orthopedics ; 31(12 Suppl 2)2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19298017

RESUMO

Large-diameter metal-metal total hip replacement (THR) offers the advantages of low wear and low dislocation risk. the aim of this investigation was to compare metal levels in large and small-diameter metal-metal hip replacements. Whole blood concentrations and daily output of cobalt and chromium in 28 patients with unilateral large diameter (42- to 54-mm) metal on metal hip replacements at 1-year follow-up were compared with levels in patients with 28-mm metal-on-metal THRs. Both bearings were made of high-carbon cobalt-chrome alloy. The larger bearing is as-cast and the smaller wrought alloy. High-resolution inductively coupled plasma mass spectrometry was used for analysis. The patients had either a cemented polished tapered stainless steel stem or a cementless porous ingrowth titanium alloy stem. Mean whole blood levels in the small- and large-diameter THRs are not significantly different at 1 year (cobalt, 1.7 vs 2.3 microg/L and chromium 1.7 vs 1.4 microg/L). Daily urinary output of cobalt and chromium was also in the same range and without a significant mean difference (cobalt 11.6 microg/24 h in large-diameter and 12.3 microg/24 h in small-diameter THRs and chromium 3.7 and 4.1 microg/24 h, respectively).


Assuntos
Artroplastia de Quadril/instrumentação , Cromo/sangue , Cromo/urina , Cobalto/sangue , Cobalto/urina , Prótese de Quadril , Idoso , Feminino , Humanos , Masculino , Metais/sangue , Metais/urina , Pessoa de Meia-Idade
8.
Orthopedics ; 31(12 Suppl 2)2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19298020

RESUMO

This is a 1.2- to 5.3-year survival and clinicoradiologic study of patients with the Birmingham Mid-Head Resection (BMHR) device (Smith & Nephew Orthopaedics, Warwick, United Kingdom). Sixty consecutive hips implanted with this device between 2003 and 2007 were reviewed with hip outcome questionnaires, clinical examination, and radiographs at a minimum follow-up of 1 year. There were no revisions, mechanical failures, or signs of femoral neck stress shielding. All hips were functioning well and showed no significant adverse clinical or radiographic features. Birmingham Mid-Head Replacement offers the prospect of circumventing the need for a more invasive procedure such as hip replacement in patients who would benefit from a conservative arthroplasty but lack femoral head bone quality, which is a prerequisite for a successful hip resurfacing.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Satisfação do Paciente , Recuperação de Função Fisiológica , Adulto , Idoso , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Resultado do Tratamento
9.
Clin Orthop Relat Res ; 441: 91-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16330990

RESUMO

UNLABELLED: The success of metal-on-metal hip resurfacing in the medium term in young and active patients is becoming evident. The procedure now can be done using a minimal approach developed by the senior author using a single posterior incision. This mini-incision resurfacing arthroplasty of the hip has made resurfacing more attractive to surgeons and patients. But does a mini incision approach allow reliable component placement? The results of 232 consecutive Birmingham Hip Resurfacings done using this approach between January and December 2004 are presented. Mean incision length was 11.8 cm. Seventy-seven percent of the incisions were between 9 and 12 cm long. Body mass index of the patients studied ranged from 17.6 to 46.7. Comparing the traditional approach with the mini-incision resurfacing arthroplasty of hip did not show a difference between the two groups in terms of operating time. The mean hospital stay was reduced by a day in the mini-incision group. The mean inclination of the acetabular components was within the target range in the two groups. Patient feedback shows that reduced postoperative pain, faster recovery rate, and better cosmesis make the mini-incision approach very popular. Although the mini incision is indeed appealing, it has a steep learning curve. In the early phase of the learning curve, care should be taken to avoid suboptimal component placement, which has the potential to affect long-term outcome adversely. LEVEL OF EVIDENCE: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Artroplastia de Quadril/instrumentação , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Satisfação do Paciente , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...