RESUMO

The spatial resolution of diagnostic Computed Tomography (CT) has increased substantially, and 3D isotropic sub-millimeter spatial resolution in both axial and helical scan modes is routinely available in the clinic. However, driven by advanced clinical applications, the pursuit for higher spatial resolution and free of aliasing artifacts in diagnostic CT has never stopped. A method to accommodate focal spot wobbling at an arbitrary number of projection views per gantry rotation in CT is presented and evaluated here. The method employs a beta-correction scheme in the row-wise fan-to-parallel rebinning to transform the native cone beam geometry into the cone-parallel geometry under which existing 3D weighted cone beam filtered backprojection algorithms can be utilized for image reconstruction. The experimental evaluation shows that the row-wise fan-to-parallel rebinning with the beta-correction can increase the quantitative in-plane spatial resolution (Modulation Transfer Function) substantially, while the visual spatial resolution can be enhanced significantly. Consequently, the architectural designers of CT scanners are no longer constrained to choosing the number of projection views per rotation determined by gantry geometry. Instead, they can choose the number of projection views per rotation to optimize the trade-offs between in-plane spatial resolution and noise characteristics. Therefore, the presented method is of practical relevance in the architectural design of state-of-the-art diagnostic CT.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imagens de Fantasmas , Tungstênio
2.
Int J Biomed Imaging ; 2006: 45942, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-23165031

RESUMO

A three-dimensional (3D) weighted helical cone beam filtered backprojection (CB-FBP) algorithm (namely, original 3D weighted helical CB-FBP algorithm) has already been proposed to reconstruct images from the projection data acquired along a helical trajectory in angular ranges up to [0, 2 π]. However, an overscan is usually employed in the clinic to reconstruct tomographic images with superior noise characteristics at the most challenging anatomic structures, such as head and spine, extremity imaging, and CT angiography as well. To obtain the most achievable noise characteristics or dose efficiency in a helical overscan, we extended the 3D weighted helical CB-FBP algorithm to handle helical pitches that are smaller than 1: 1 (namely extended 3D weighted helical CB-FBP algorithm). By decomposing a helical over scan with an angular range of [0, 2π + Δß] into a union of full scans corresponding to an angular range of [0, 2π], the extended 3D weighted function is a summation of all 3D weighting functions corresponding to each full scan. An experimental evaluation shows that the extended 3D weighted helical CB-FBP algorithm can improve noise characteristics or dose efficiency of the 3D weighted helical CB-FBP algorithm at a helical pitch smaller than 1: 1, while its reconstruction accuracy and computational efficiency are maintained. It is believed that, such an efficient CB reconstruction algorithm that can provide superior noise characteristics or dose efficiency at low helical pitches may find its extensive applications in CT medical imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA