Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ultrasound Med ; 39(8): 1581-1587, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32073680

RESUMO

OBJECTIVES: The aim of this study was to explore the motivations of pregnant women in participating in an ultrasound study and the acceptability of vaginal ultrasound examinations. METHODS: A prospective sample of 270 women were asked one question: "Can you tell me what motivated you to participate in the study?" The data were then analyzed through a qualitative thematic analysis with an inductive approach. In addition to the thematic analysis, quantification of the data was performed to enhance the qualitative result. RESULTS: Through the thematic analysis, 5 themes emerged from the responses of the participants: altruism, research, personal experience, personal benefit, and finding out. All responses were relatively short, and some responses included more than one theme. CONCLUSIONS: Vaginal ultrasound examinations were acceptable to the participants, and pregnant women had many motivations to participate. Regardless of race, ethnicity, or insurance status, the women in our study were altruistic and curious about our research.


Assuntos
Gestantes , Sujeitos da Pesquisa , Feminino , Humanos , Motivação , Gravidez , Estudos Prospectivos , Ultrassonografia
2.
Artigo em Inglês | MEDLINE | ID: mdl-31217100

RESUMO

This article evaluated the repeatability and reproducibility (R&R) of quantitative ultrasound (QUS) biomarkers attenuation coefficient (AC) and backscatter coefficient (BSC) in transvaginal QUS reference phantoms for obstetric applications. Five phantoms were scanned by three sonographers according to the scanning protocol. Each sonographer scanned each phantom with four transvaginal transducers of the same model (MC9-4) and three probe cover types (latex cover, nonlatex cover, and no cover). The AC and BSC were estimated by using a reference phantom method. The R&R analysis was performed for the frequency-averaged AC and logBSC (= 10log10BSC) (5.4-5.8 MHz) by using three-factor random effects Analysis of Variance with interaction. The total R&R variabilities for AC and logBSC are small (AC: 0.042-0.065 dB/cm-MHz; logBSC: 0.50-0.68 dB), indicating high measurement precision. These values are small compared to the ranges of AC (0.28-0.99 dB/cm-MHz) and logBSC (-33.16 to -20.35 dB) of the five phantoms. The AC and logBSC biomarkers measured on transvaginal QUS phantoms using the reference phantom method are repeatable, and reproducible between sonographers, transducers, and probe covers.


Assuntos
Ultrassonografia/métodos , Vagina , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA