Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Kidney Int Rep ; 9(4): 929-940, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38765568

RESUMO

Introduction: Peritonitis is the leading complication of peritoneal dialysis (PD). Patients are instructed to seek care promptly for signs (cloudy effluent) or symptoms (abdominal pain), and earlier treatment improves outcomes. The CloudCath Peritoneal Dialysis Drain Set Monitoring (CloudCath) system monitors turbidity in dialysis effluent and sends notifications of changes signaling possible peritonitis. Methods: We conducted this single-arm, open-label, multicenter study of CloudCath system use during PD. We deactivated system notifications to participants and investigators, who followed standard-of-care for peritonitis signs and symptoms. Effectiveness endpoints measured time between CloudCath system notifications and peritonitis events using International Society of Peritoneal Dialysis (ISPD) criteria. Results: Two hundred forty-three participants used the CloudCath system for 178.8 patient-years. Of 71 potential peritonitis events, 51 events (0.29 per patient-year) met ISPD white blood cell (WBC) count criteria. The system triggered notifications for 41 of 51 events (80.4%), with a median lead time of 2.6 days (10%-90% range, -1.0 to 15.7; P < 0.0001). Excluding 6 peritonitis events that occurred when the system was not in use, the system triggered notifications for 41 of 45 events (91.1%), with a median lead time of 3.0 days (10%-90% range, -0.5 to 18.8; P < 0.0001). Of the 0.78 notifications per patient-year, the majority were peritonitis events or nonperitonitis events such as exit site and tunnel infections or catheter/cycler issues. Conclusion: The CloudCath system detected peritonitis events during PD several days earlier than the current standard-of-care and has the capacity to send notifications that could expedite peritonitis diagnosis and treatment.

2.
Exp Brain Res ; 176(3): 448-64, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16896977

RESUMO

The purpose of this study was to determine motor output variability for different muscles in the same individuals. Ten young (21.7 +/- 3.4 years) and ten elderly (72.1 +/- 3.9 years) men underwent assessment of maximal isometric (MVC) and dynamic (1-RM) strength, and performed constant-force (2-50% MVC), constant-load (5-50% 1-RM load), and unloaded postural contractions as steadily as possible with the first dorsal interosseus (FDI), elbow flexors (EF), and knee extensors (KE). The coefficient of variation (CV) of force for isometric contractions and the standard deviation (SD) of acceleration for concentric, eccentric, and postural contractions were calculated. The 1-RM load, the CV of force for four of five isometric target forces, and the SD of acceleration during postural contractions were correlated between the EF and KE muscles. MVC force, 1-RM load, and SD of acceleration during postural contractions were not correlated between the FDI/EF or FDI/KE. The CV of force was correlated between the FDI/EF and FDI/KE for two of five isometric target forces. The SD of acceleration during concentric and eccentric contractions was not correlated between muscles. The normalized fluctuations during isometric contractions were greater for the FDI compared with the EF and KE. Elderly adults displayed greater fluctuations only for the FDI during low-force isometric and postural contractions. The dominant frequency of fluctuations was similar for the EF and KE muscles. The correlated fluctuations for the EF and KE muscles, within subjects, suggests that the two motor neuron pools transform the various neural inputs similarly.


Assuntos
Cotovelo/inervação , Contração Isométrica/fisiologia , Joelho/inervação , Músculo Esquelético/fisiologia , Adolescente , Adulto , Fatores Etários , Idoso , Cotovelo/efeitos da radiação , Estimulação Elétrica/métodos , Eletromiografia/métodos , Feminino , Análise de Fourier , Humanos , Contração Isométrica/efeitos da radiação , Joelho/efeitos da radiação , Masculino , Músculo Esquelético/efeitos da radiação , Dinâmica não Linear , Postura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA