Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Clin Anat ; 37(4): 440-454, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38217386

RESUMO

An intricate meshwork of trabeculations lines the luminal side of cardiac ventricles. Compaction, a developmental process, is thought to reduce trabeculations by adding them to the neighboring compact wall which is then enlarged. When pig, a plausible cardiac donor for xenotransplantation, is compared to human, the ventricular walls appear to have fewer trabeculations. We hypothesized the trabecular volume is proportionally smaller in pig than in human. Macroscopically, we observed in 16 pig hearts that the ventricular walls harbor few but large trabeculations. Close inspection revealed a high number of tiny trabeculations, a few hundred, within the recesses of the large trabeculations. While tiny, these were still larger than embryonic trabeculations and even when considering their number, the total tally of trabeculations in pig was much fewer than in human. Volumetrics based on high-resolution MRI of additional six pig hearts compared to six human hearts, revealed the left ventricles were not significantly differently trabeculated (21.5 versus 22.8%, respectively), and the porcine right ventricles were only slightly less trabeculated (42.1 vs 49.3%, respectively). We then analyzed volumetrically 10 pig embryonic hearts from gestational day 14-35. The trabecular and compact layer always grew, as did the intertrabecular recesses, in contrast to what compaction predicts. The proportions of the trabecular and compact layers changed substantially, nonetheless, due to differences in their growth rate rather than compaction. In conclusion, processes that affect the trabecular morphology do not necessarily affect the proportion of trabecular-to-compact myocardium and they are then distinct from compaction.


Assuntos
Ventrículos do Coração , Coração , Humanos , Animais , Suínos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/anatomia & histologia , Coração/anatomia & histologia , Miocárdio
2.
Front Physiol ; 14: 1295103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38152249

RESUMO

The body surface electrocardiogram (ECG) is a direct result of electrical activity generated by the myocardium. Using the body surface ECGs to reconstruct cardiac electrical activity is called the inverse problem of electrocardiography. The method to solve the inverse problem depends on the chosen cardiac source model to describe cardiac electrical activity. In this paper, we describe the theoretical basis of two inverse methods based on the most commonly used cardiac source models: the epicardial potential model and the equivalent dipole layer model. We discuss similarities and differences in applicability, strengths and weaknesses and sketch a road towards improved inverse solutions by targeted use, sequential application or a combination of the two methods.

4.
J Am Heart Assoc ; 12(14): e026419, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37421262

RESUMO

Background An elegant bedside provocation test has been shown to aid the diagnosis of long-QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T-wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS. Methods and Results In adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T-wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate-corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47-74) in men and 54% (95% CI, 42-66) in women, with a specificity of 90% (95% CI, 80-96) and 89% (95% CI, 81-95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83-94]) but decreased specificity (49% [95% CI, 41-57]). Sensitivity further increased (P<0.01) when a prolonged baseline QTc was accompanied by a QTc≥460 ms after standing in both men (93% [95% CI, 84-98]) and women (90% [95% CI, 81-96]). However, the area under the curve did not improve. T-wave abnormalities after standing did not further increase the sensitivity or the area under the curve significantly. Conclusions Despite earlier retrospective studies, a baseline ECG and the standing test in a prospective evaluation displayed a different diagnostic profile for congenital LQTS but no unequivocal synergism or advantage. This suggests that there is markedly reduced penetrance and incomplete expression in genetically confirmed LQTS with retention of repolarization reserve in response to the brief tachycardia provoked by standing.


Assuntos
Eletrocardiografia , Síndrome do QT Longo , Masculino , Humanos , Adulto , Feminino , Estudos Retrospectivos , Eletrocardiografia/métodos , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Síndrome do QT Longo/congênito , Taquicardia , Posição Ortostática
5.
Front Physiol ; 14: 1330230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38179141

RESUMO

Background: An electrical storm of Torsade de Pointes arrhythmias (TdP) can be reproducibly induced in the anesthetized chronic AV-block (CAVB) dog by infusion of the IKr-blocker dofetilide. Earlier studies showed that these arrhythmias 1) arise from locations with high spatial dispersion in repolarization (SDR) and 2) can be suppressed by high-rate pacing. We examined whether suppression of TdP by high-rate pacing is established through a decrease in SDR in the CAVB dog. Methods: Dofetilide (25 µg/kg in 5 min) was administered to 5 anesthetized CAVB dogs to induce TdP arrhythmias. During the experiments, animals were continuously paced from the right ventricular apex at 50 beats/minute (RVA50). Upon TdP occurrence and conversion, RVA pacing was consecutively set to 100, 80 and 60 beats/minute for 2 min, referred to as pacing blocks. To determine the additional anti-arrhythmic effects of HRP over defibrillation alone, the number of arrhythmic events and SDR at RVA100 were compared to data from three previously conducted experiments, in which dogs underwent the same experimental protocol but were paced at RVA60 upon TdP occurrence (RVA60retro). In all experiments, recordings included surface electrocardiogram and mapping by 56 intramural needles, each recording four electrograms, evenly inserted into the ventricular walls and septum. For each pacing block, the number of ectopic beats (EB), and TdP severity were scored. SDR was quantified as the average difference in repolarization time within four squared needles (SDRcubic). Results: In 4 out of 5 animals, pacing at RVA100 suppressed TdP occurrence. One dog could not be converted by defibrillation after the initial TdP. Compared to RVA50, pacing at RVA100, but not RVA80 and RVA60, significantly reduced the TdP score (78 ± 33 vs. 0 ± 0, p < 0.05 and vs. 12.5 ± 25 and 25 ± 50, both p > 0.05). The reduction in TdP score was reflected by a significant decrease in SDRcubic (125 ± 46 ms before TdP vs. 49 ± 18 ms during RVA100, p < 0.05), and SDR was smaller than in the RVA60retro animals (101 ± 52 ms, p < 0.05 vs. RVA100). Conclusion: In CAVB dogs, high-rate pacing effectively suppresses TdP, which, at least in part, results from a spatial homogenization of cardiac repolarization, as reflected by a decrease in SDR.

6.
Ann Noninvasive Electrocardiol ; 27(6): e12994, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35986562

RESUMO

BACKGROUND: The T wave of the electrocardiogram (ECG) reflects ventricular repolarization. Repolarization heterogeneity is associated with reentrant arrhythmias. Several T-wave markers (including QT interval) have been associated with ventricular arrhythmias, but studies linking such markers to underlying local repolarization time (RT) inhomogeneities are lacking. We aimed to investigate the relation of several T-wave markers to controlled drug-induced regional RT gradients in intact pig hearts. METHODS: Repolarization time gradients were created by regional infusion of dofetilide and pinacidil in four atrially paced porcine Langendorff-perfused hearts placed inside a torso tank. From the 12-lead ECG on the torso tank, the mean, maximum, and dispersion (max-min) of QTtime , JTtime , Tpeak-end , Twidth , TQratio , dV/dtmax , Tarea , Tamp , and T-upslope duration were determined, as well as upslope end difference between leads V1 and V6 . RESULTS: Temporal T-wave parameters Tpeak-end , Twidth, and TQratio show a significant and high correlation with RT gradient, best reflected by mean value. Tarea (mean, max and dispersion) and dV/dtmax dispersion show only a moderate significant correlation. T-upslope duration shows a significant correlation in particular for mean values. Mean, maximum, or dispersion of QTtime and V1 -V6 upslope end difference were not significantly correlated with RT gradient. CONCLUSION: Composite 12-lead ECG T-wave parameters Tpeak-end , Twidth , TQratio , upslope duration, and Tarea show a good correlation with underlying RT heterogeneity, whereas standard clinical metrics such as QTtime do not reflect local RT heterogeneity. The composite T-wave metrics may thus provide better insights in arrhythmia susceptibility than traditional QTtime metrics.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Humanos , Suínos , Animais , Coração , Pinacidil
7.
Front Physiol ; 12: 737609, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34744778

RESUMO

Background: The detection and localization of electrophysiological substrates currently involve invasive cardiac mapping. Electrocardiographic imaging (ECGI) using the equivalent dipole layer (EDL) method allows the noninvasive estimation of endocardial and epicardial activation and repolarization times (AT and RT), but the RT validation is limited to in silico studies. We aimed to assess the temporal and spatial accuracy of the EDL method in reconstructing the RTs from the surface ECG under physiological circumstances and situations with artificially induced increased repolarization heterogeneity. Methods: In four Langendorff-perfused pig hearts, we simultaneously recorded unipolar electrograms from plunge needles and pseudo-ECGs from a volume-conducting container equipped with 61 electrodes. The RTs were computed from the ECGs during atrial and ventricular pacing and compared with those measured from the local unipolar electrograms. Regional RT prolongation (cooling) or shortening (pinacidil) was achieved by selective perfusion of the left anterior descending artery (LAD) region. Results: The differences between the computed and measured RTs were 19.0 ± 17.8 and 18.6 ± 13.7 ms for atrial and ventricular paced beats, respectively. The region of artificially delayed or shortened repolarization was correctly identified, with minimum/maximum RT roughly in the center of the region in three hearts. In one heart, the reconstructed region was shifted by ~2.5 cm. The total absolute difference between the measured and calculated RTs for all analyzed patterns in selectively perfused hearts (n = 5) was 39.6 ± 27.1 ms. Conclusion: The noninvasive ECG repolarization imaging using the EDL method of atrial and ventricular paced beats allows adequate quantitative reconstruction of regions of altered repolarization.

8.
J Am Coll Cardiol ; 78(17): 1730-1745, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34674819

RESUMO

Obesity is a significant risk factor for arrhythmic cardiovascular death. Interactions between epicardial adipose tissue (EAT) and myocytes are thought to play a key role in the development of arrhythmias. In this review, the authors investigate the influence of EAT on arrhythmogenesis. First, they summarize electrocardiographic evidence showing the association between increased EAT volume and atrial and ventricular conduction delay. Second, they detail the structural cross talk between EAT and the heart and its arrhythmogenicity. Adipose tissue infiltration within the myocardium constitutes an anatomical obstacle to cardiac excitation. It causes activation delay and increases the risk of arrhythmias. Intercellular electrical coupling between cardiomyocytes and EAT can further slow conduction and increase the risk of block, favoring re-entry and arrhythmias. Finally, EAT secretes multiple substances that influence cardiomyocyte electrophysiology either by modulating ion currents and electrical coupling or by stimulating fibrosis. Thus, structural and paracrine cross talk between EAT and cardiomyocytes facilitates arrhythmias.


Assuntos
Tecido Adiposo/fisiopatologia , Arritmias Cardíacas/etiologia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Cardiologia/métodos , Pericárdio/fisiopatologia , Adipócitos/citologia , Adipocinas/metabolismo , Tecido Adiposo/metabolismo , Animais , Cardiologia/normas , Doenças Cardiovasculares/metabolismo , Eletrofisiologia , Junções Comunicantes/metabolismo , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Camundongos , Miocárdio/metabolismo , Miocárdio/patologia , Miócitos Cardíacos/metabolismo , Obesidade , Potássio/metabolismo , Prevalência
9.
Am J Physiol Heart Circ Physiol ; 321(3): H569-H576, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34355987

RESUMO

Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around isoelectric line) can be induced in the anesthetized chronic atrioventricular block (CAVB) dog by dofetilide (IKr blocker). The interplay between temporal dispersion of repolarization, quantified as short-term variability (STV), and spatial dispersion of repolarization (SDR) in the initiation and perpetuation of these arrhythmias remains unclear. Five inducible (≥3 TdPs/10 min) CAVB dogs underwent one mapping experiment and were observed for 10 min from the start of dofetilide infusion (0.025 mg/kg, 5 min). An intracardiac decapolar electrogram (EGM) catheter and 30 intramural cardiac needles in the left ventricle (LV) were introduced. STVARI was derived from 31 consecutive activation recovery intervals (ARIs) on the intracardiac EGM, using the formula: [Formula: see text]. The mean SDR3D in the LV was determined as the three-dimensional repolarization time differences between the intramural cardiac needles. Moments of measurement included baseline (BL) and after dofetilide infusion before first 1) sEB (occurrence at 100 ± 35 s), 2) mEB (224 ± 96 s), and 3) non-self-terminating TdP (454 ± 298 s). STVARI increased from 2.15 ± 0.32 ms at BL to 3.73 ± 0.99 ms* before the first sEB and remained increased without further significant progression to mEB (4.41 ± 0.45 ms*) and TdP (5.07 ± 0.84 ms*) (*P < 0.05 compared with BL). SDR3D did not change from 31 ± 11 ms at BL to 43 ± 13 ms before sEB but increased significantly before mEB (68 ± 7 ms*) and to TdP (86 ± 9 ms*+) (+P < 0.05 compared with sEB). An increase in STV contributes to the initiation of sEB, whereas an increase in SDR is important for the perpetuation of non-self-terminating TdPs.NEW & NOTEWORTHY This study compared two well-established electrophysiological parameters, being temporal and spatial dispersion of repolarization, and provided new insights into their interplay in the arrhythmogenesis of torsades de pointes arrhythmias. Although it confirmed that an increase in temporal dispersion of repolarization contributes to the initiation of single ectopic beats, it showed that an increase in spatial dispersion of repolarization is important for the perpetuation of non-self-terminating torsades de pointes arrhythmias.


Assuntos
Bloqueio Atrioventricular/fisiopatologia , Modelos Cardiovasculares , Torsades de Pointes/fisiopatologia , Potenciais de Ação , Animais , Bloqueio Atrioventricular/complicações , Cães , Feminino , Masculino , Tempo de Reação , Torsades de Pointes/etiologia
10.
Front Physiol ; 12: 642083, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33981248

RESUMO

INTRODUCTION: Torsade de pointes arrhythmias (TdP) in the chronic atrioventricular block (CAVB) dog model result from proarrhythmic factors, which trigger TdP and/or reinforce the arrhythmic substrate. This study investigated electrophysiological and arrhythmogenic consequences of severe bradycardia for TdP. METHODS: Dofetilide (25 µg/kg per 5 min) was administered to eight anesthetized, idioventricular rhythm (IVR) remodeled CAVB dogs in two serial experiments: once under 60 beats per minute (bpm), right ventricular apex paced (RVA60) conditions, once under more bradycardic IVR conditions. Recordings included surface electrocardiogram and short-term variability (STV) of repolarization from endocardial unipolar electrograms. TdP inducibility (three or more episodes within 10 min after start of dofetilide) and arrhythmic activity scores (AS) were established. Mapping experiments in 10 additional dogs determined the effect of lowering rate on STV and spatial dispersion of repolarization (SDR) in baseline. RESULTS: IVR-tested animals had longer baseline RR-interval (1,403 ± 271 ms) and repolarization intervals than RVA60 animals. Dofetilide increased STV similarly under both rhythm strategies. Nevertheless, TdP inducibility and AS were higher under IVR conditions (6/8 and 37 ± 27 vs. 1/8 and 8 ± 12 in RVA60, respectively, both p < 0.05). Mapping: Pacing from high (128 ± 10 bpm) to middle (88 ± 10 bpm) to experimental rate (61 ± 3 bpm) increased all electrophysiological parameters, including interventricular dispersion, due to steeper left ventricular restitution curves, and intraventricular SDR: maximal cubic dispersion from 60 ± 14 (high) to 69 ± 17 (middle) to 84 ± 22 ms (p < 0.05 vs. high and middle rate). CONCLUSION: In CAVB dogs, severe bradycardia increases the probability and severity of arrhythmic events by heterogeneously causing electrophysiological instability, which is mainly reflected in an increased spatial, and to a lesser extent temporal, dispersion of repolarization.

11.
Front Physiol ; 12: 648396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33833689

RESUMO

Ablation of sites showing Purkinje activity is antiarrhythmic in some patients with idiopathic ventricular fibrillation (iVF). The mechanism for the therapeutic success of ablation is not fully understood. We propose that deeper penetrance of the Purkinje network allows faster activation of the ventricles and is proarrhythmic in the presence of steep repolarization gradients. Reduction of Purkinje penetrance, or its indirect reducing effect on apparent propagation velocity may be a therapeutic target in patients with iVF.

12.
Cardiovasc Res ; 117(9): 2083-2091, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-32853334

RESUMO

AIMS: Enhanced sympathetic activity during acute ischaemia is arrhythmogenic, but the underlying mechanism is unknown. During ischaemia, a diastolic current flows from the ischaemic to the non-ischaemic myocardium. This 'injury' current can cause ventricular premature beats (VPBs) originating in the non-ischaemic myocardium, especially during a deeply negative T wave in the ischaemic zone. We reasoned that shortening of repolarization in myocardium adjacent to ischaemic myocardium increases the 'injury' current and causes earlier deeply negative T waves in the ischaemic zone, and re-excitation of the normal myocardium. We tested this hypothesis by activation and repolarization mapping during stimulation of the left stellate ganglion (LSG) during left anterior descending coronary artery (LAD) occlusion. METHODS AND RESULTS: In nine pigs, five subsequent episodes of acute ischaemia, separated by 20 min of reperfusion, were produced by occlusion of the LAD and 121 epicardial local unipolar electrograms were recorded. During the third occlusion, left stellate ganglion stimulation (LSGS) was initiated after 3 min for a 30-s period, causing a shortening of repolarization in the normal myocardium by about 100 ms. This resulted in more negative T waves in the ischaemic zone and more VPBs than during the second, control, occlusion. Following the decentralization of the LSG (including removal of the right stellate ganglion and bilateral cervical vagotomy), fewer VPBs occurred during ischaemia without LSGS. During LSGS, the number of VPBs was similar to that recorded before decentralization. CONCLUSION: LSGS, by virtue of shortening of repolarization in the non-ischaemic myocardium by about 100 ms, causes deeply negative T waves in the ischaemic tissue and VPBs originating from the normal tissue adjacent to the ischaemic border.


Assuntos
Potenciais de Ação , Frequência Cardíaca , Coração/inervação , Isquemia Miocárdica/complicações , Gânglio Estrelado/fisiopatologia , Complexos Ventriculares Prematuros/etiologia , Animais , Modelos Animais de Doenças , Estimulação Elétrica , Feminino , Isquemia Miocárdica/fisiopatologia , Sus scrofa , Fatores de Tempo , Complexos Ventriculares Prematuros/fisiopatologia
13.
Heart Rhythm ; 18(2): 278-287, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33031961

RESUMO

BACKGROUND: Torsades de pointes arrhythmia is a potentially lethal polymorphic ventricular tachyarrhythmia (pVT) in the setting of long QT syndrome. Arrhythmia susceptibility is influenced by risk factors modifying repolarization. OBJECTIVE: The purpose of this article was to characterize repolarization duration and heterogeneity in relation to pVT inducibility and maintenance. METHODS: Sotalol was infused regionally or globally in isolated Langendorff blood-perfused pig hearts (N = 7) to create repolarization time (RT) heterogeneities. Programmed stimulation and epicardial activation and repolarization mapping were performed. The role of RT (heterogeneities) was studied in more detail using a computer model of the human heart. RESULTS: pVTs (n = 11) were inducible at a critical combination of RT and RT heterogeneities. The pVT cycle lengths were similar in the short and long RT regions. Short-lasting pVTs were maintained by focal activity while longer-lasting pVTs by reentry wandering along the interface between the 2 regions. Local restitution curves from the long and short RT regions crossed. This was associated with T-wave inversion at coupling intervals at either side of the crossing point. These experimental observations were confirmed by the computer simulations. CONCLUSION: pVTs are inducible within a critical range of RT and RT heterogeneities and are maintained by reentry wandering along the repolarization gradient. Double potentials localize at the core of the reentrant circuit and reflect phase singularities. RT gradient and T waves invert with short-coupled premature beats in the long RT region as a result of the crossing of the restitution curves allowing reentry initiation.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Síndrome do QT Longo/fisiopatologia , Torsades de Pointes/complicações , Potenciais de Ação/fisiologia , Animais , Modelos Animais de Doenças , Eletrocardiografia , Síndrome do QT Longo/etiologia , Suínos , Torsades de Pointes/fisiopatologia
14.
JACC Clin Electrophysiol ; 6(11): 1395-1404, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33121669

RESUMO

OBJECTIVES: The aim of this study was to investigate the mechanism underlying QRS-slurring in a patient with the early repolarization pattern in the electrocardiogram (ECG) and ventricular fibrillation (VF) storms. BACKGROUND: The early repolarization pattern refers to abnormal ending of the QRS complex in subjects with structurally normal hearts and has been associated with VF. METHODS: We studied a patient with slurring of the QRS complex in leads II, III, and aVF of the ECG and recurrent episodes of VF. Echocardiographic and imaging studies did not reveal any abnormalities. Endocardial mapping was normal but subxyphoidal epicardial access was not possible. Open chest epicardial mapping was performed. RESULTS: Mapping showed that the inferior right ventricular free wall activated the latest with local J-waves in unipolar electrograms. The last moment of epicardial activation concurred with QRS-slurring in the ECG whereas the J-waves in the local unipolar electrograms occurred in the ST-segment of the ECG. Myocardial biopsies obtained from the late activated tissue showed severe fibrofatty alterations in the inferior right ventricular wall where fractionation and local J-waves were present. After ablation, the early repolarization pattern in the ECG disappeared and arrhythmias have been absent since (follow-up 18 months). CONCLUSIONS: In this patient, the electrocardiographic early repolarization pattern was caused by late activation due to structurally abnormal myocardium. The late activated areas were marked by J-waves in local electrograms. Ablation of these regions prevented arrhythmia recurrence and normalized the ECG.


Assuntos
Arritmias Cardíacas , Fibrilação Ventricular , Eletrocardiografia , Mapeamento Epicárdico , Humanos , Miocárdio
15.
Front Physiol ; 11: 465, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32508676

RESUMO

BACKGROUND: Re-entrant ventricular tachycardia may be non-inducible or haemodynamically compromising, requiring assessment of the electrophysiological properties of the myocardium during sinus rhythm (i.e., substrate mapping). Areas of heart tissue with slow conduction can act as a critical isthmus for re-entrant electrical excitation and are a potential target for ablation therapy. AIM: To develop and validate a novel metric of local conduction delay in the heart, the amplitude-normalized electrogram area (norm_EA). METHODS: A computational model of a propagating mouse action potential was used to establish the impact of altering sodium channel conductance, intracellular conductivity, fibrosis density, and electrode size/orientation on bipolar electrogram morphology. Findings were then validated in experimental studies in mouse and guinea pig hearts instrumented for the recording of bipolar electrograms from a multipolar linear mapping catheter. norm_EA was calculated by integrating the absolute area of a bipolar electrogram divided by the electrogram amplitude. Electrogram metrics were correlated with the local conduction delay during sodium channel block, gap junction inhibition, and acute ischemia. RESULTS: In computational simulations, reducing sodium channel conductance and intracellular conductivity resulted in a decrease in signal amplitude and increase in norm_EA (reflecting a broadening of electrogram morphology). For larger electrodes (3 mm diameter/7.1 mm2 area), the change in norm_EA was essentially linear with the change in local conduction delay. Experimental studies supported this finding, showing that the magnitude of change in norm_EA induced by flecainide (1-4 µM), carbenoxolone (10-50 µM), and low-flow ischemia (25% of initial flow rate) was linearly correlated with the local conduction delay in each condition (r 2 = 0.92). Qualitatively similar effects were observed in guinea pig hearts perfused with flecainide. Increasing fibrosis density in the computational model also resulted in a decrease in signal amplitude and increase in norm_EA. However, this remains to be validated using experimental/clinical data of chronic infarct. CONCLUSION: norm_EA is a quantitative measure of local conduction delay between the electrode pair that generates a bipolar electrogram, which may have utility in electrophysiological substrate mapping of non-inducible or haemodynamically compromising tachyarrhythmia.

16.
Front Physiol ; 11: 557, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32536879

RESUMO

Genome Wide Association Studies (GWAS) have provided an enormous amount of data on genomic loci associated with cardiac electrophysiology and arrhythmias. Clinical relevance, however, remains unclear since GWAS do not provide a mechanistic explanation for this association. Determining the electrophysiological relevance of variants for arrhythmias would aid development of risk stratification models for patients with arrhythmias. In this review, we give an overview of genetic variants related to ECG intervals and arrhythmogenic pathologies and discuss how these variants may influence cardiac electrophysiology and the occurrence of arrhythmias.

17.
Med Biol Eng Comput ; 58(8): 1739-1749, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32474796

RESUMO

The solution of the inverse problem of electrocardiology allows the reconstruction of the spatial distribution of the electrical activity of the heart from the body surface electrocardiogram (electrocardiographic imaging, ECGI). ECGI using the equivalent dipole layer (EDL) model has shown to be accurate for cardiac activation times. However, validation of this method to determine repolarization times is lacking. In the present study, we determined the accuracy of the EDL model in reconstructing cardiac repolarization times, and assessed the robustness of the method under less ideal conditions (addition of noise and errors in tissue conductivity). A monodomain model was used to determine the transmembrane potentials in three different excitation-repolarization patterns (sinus beat and ventricular ectopic beats) as the gold standard. These were used to calculate the body surface ECGs using a finite element model. The resulting body surface electrograms (ECGs) were used as input for the EDL-based inverse reconstruction of repolarization times. The reconstructed repolarization times correlated well (COR > 0.85) with the gold standard, with almost no decrease in correlation after adding errors in tissue conductivity of the model or noise to the body surface ECG. Therefore, ECGI using the EDL model allows adequate reconstruction of cardiac repolarization times. Graphical abstract Validation of electrocardiographic imaging for repolarization using forward calculated body surface ECGs from simulated activation-repolarization sequences.


Assuntos
Diagnóstico por Imagem/métodos , Eletrocardiografia/métodos , Endocárdio/diagnóstico por imagem , Mapeamento Epicárdico/métodos , Adulto , Mapeamento Potencial de Superfície Corporal/métodos , Simulação por Computador , Humanos , Miocárdio/patologia
18.
Heart Rhythm ; 17(5 Pt A): 795-803, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31917369

RESUMO

BACKGROUND: Dispersion in ventricular repolarization is relevant for arrhythmogenesis. OBJECTIVE: The purpose of this study was to determine the spatiotemporal effects of sympathetic stimulation on ventricular repolarization. METHODS: In 5 anesthetized female open-chest pigs, ventricular repolarization was measured from the anterior, lateral, and posterior walls of the left ventricle (LV) and right ventricle using up to 40 transmural plunge needles (4 electrodes each) before and after left stellate ganglion stimulation (LSGS) and right stellate ganglion stimulation. In addition, LSGS was performed in 3 pigs (2 male, 1 female) before and after verapamil (5-10 mg/h) administration. RESULTS: LSGS yielded a biphasic response in repolarization in the lateral and posterior walls of the LV, with prolongation at ∼5 seconds (10 ± 1.5 ms) and shortening at 20-30 seconds of stimulation (-28.9 ± 4.4 ms) during a monotonic pressure increase. While the initial prolongation was abolished by verapamil, late shortening was augmented. Sequential transections of the vagal nerve and stellate ganglia augmented repolarization dispersion responses to LSGS in 2 of 5 hearts. An equal pressure increase by aortic occlusion resulted in a homogeneous shortening of repolarization in the LV, and the effects were smaller than those during LSGS. Right stellate stimulation shortened repolarization mainly in the anterior LV wall, but the effects were smaller than those of LSGS. CONCLUSION: LSGS first prolongs (through the L-type calcium current) and then shortens repolarization. The effect of LSGS was prominent in the posterior and lateral, not the anterior, LV walls.


Assuntos
Estimulação Elétrica/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Gânglio Estrelado/fisiopatologia , Taquicardia Ventricular/terapia , Função Ventricular Esquerda/fisiologia , Animais , Modelos Animais de Doenças , Feminino , Masculino , Prognóstico , Suínos , Taquicardia Ventricular/fisiopatologia
19.
BMC Cardiovasc Disord ; 19(1): 254, 2019 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-31711426

RESUMO

BACKGROUND: The PhysioHeart™ is a mature acute platform, based isolated slaughterhouse hearts and able to validate cardiac devices and techniques in working mode. Despite perfusion, myocardial edema and time-dependent function degradation are reported. Therefore, monitoring several variables is necessary to identify which of these should be controlled to preserve the heart function. This study presents biochemical, electrophysiological and hemodynamic changes in the PhysioHeart™ to understand the pitfalls of ex vivo slaughterhouse heart hemoperfusion. METHODS: Seven porcine hearts were harvested, arrested and revived using the PhysioHeart™. Cardiac output, SaO2, glucose and pH were maintained at physiological levels. Blood analyses were performed hourly and unipolar epicardial electrograms (UEG), pressures and flows were recorded to assess the physiological performance. RESULTS: Normal cardiac performance was attained in terms of mean cardiac output (5.1 ± 1.7 l/min) and pressures but deteriorated over time. Across the experiments, homeostasis was maintained for 171.4 ± 54 min, osmolarity and blood electrolytes increased significantly between 10 and 80%, heart weight increased by 144 ± 41 g, free fatty acids (- 60%), glucose and lactate diminished, ammonia increased by 273 ± 76% and myocardial necrosis and UEG alterations appeared and aggravated. Progressively deteriorating electrophysiological and hemodynamic functions can be explained by reperfusion injury, waste product intoxication (i.e. hyperammonemia), lack of essential nutrients, ion imbalances and cardiac necrosis as a consequence of hepatological and nephrological plasma clearance absence. CONCLUSIONS: The PhysioHeart™ is an acute model, suitable for cardiac device and therapy assessment, which can precede conventional animal studies. However, observations indicate that ex vivo slaughterhouse hearts resemble cardiac physiology of deteriorating hearts in a multi-organ failure situation and signalize the need for plasma clearance during perfusion to attenuate time-dependent function degradation. The presented study therefore provides an in-dept understanding of the sources and reasons causing the cardiac function loss, as a first step for future effort to prolong cardiac perfusion in the PhysioHeart™. These findings could be also of potential interest for other cardiac platforms.


Assuntos
Matadouros , Coração/fisiopatologia , Hemodinâmica , Preparação de Coração Isolado , Teste de Materiais , Perfusão , Animais , Metabolismo Energético , Modelos Animais , Miocárdio/metabolismo , Miocárdio/patologia , Necrose , Sus scrofa , Fatores de Tempo
20.
J Electrocardiol ; 51(5): 906-912, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30177338

RESUMO

INTRODUCTION: Chronic total coronary occlusions (CTOs) have been associated with a higher prevalence of ventricular arrhythmias compared to patients without a CTO. We evaluated the effect of CTO revascularization on electrocardiographic (ECG) variables. METHODS: We studied a selection of ST-elevation myocardial infarction patients with a concomitant CTO enrolled in the EXPLORE trial. ECG variables and cardiac function were analysed at baseline and at 4 months follow-up. RESULTS: Patients were randomized to percutaneous coronary intervention (PCI) of their CTO (n = 77) or to no-CTO PCI (n = 81). At follow-up, median QT dispersion was significantly lower in the CTO PCI group compared to the no-CTO PCI group (46 ms [33-58] vs. 54 ms [37-68], P = 0.043). No independent association was observed between ECG variables and cardiac function. CONCLUSION: Revascularization of a CTO after STEMI significantly shortened QT dispersion at 4 months follow-up. These findings support the hypothesis that CTO revascularization reduces the pro-arrhythmic substrate in CTO patients.


Assuntos
Oclusão Coronária/terapia , Eletrocardiografia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Oclusão Coronária/complicações , Oclusão Coronária/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...