Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Expert Rev Med Devices ; : 1-4, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803133

RESUMO

INTRODUCTION: The management of the false lumen (FL) when dealing with aortic dissection is a crucial aspect since inducing its thrombosis is necessary in order to achieve aortic remodeling. One of the pitfalls of endovascular treatment of aortic dissection (AD) is retrograde distal FL perfusion and pressurization, which prevents FL thrombosis and thus aortic remodeling, while being associated with aneurysmal degeneration of the FL and poor long-term outcomes. AREAS COVERED: Currently, there is no CE/FDA approved device for FL closure, however different techniques and devices have been proposed to overcome this challenge, the most known of which is the Candy Plug (CP). This review aims to describe the CP device, its implantation technique, and the available data in the literature (PubMed, Cochrane, and EMBASE databases; last queried, December 31, 2023). EXPERT OPINIONS: While the treatment of AD remains technically challenging, the use of the CP technique to close any distal FL reperfusion proved to be feasible and safe with excellent rates of both technical and clinical success. Furthermore, recent studies have shown a quick learning curve with this technique.

2.
J Clin Med ; 13(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610847

RESUMO

Vascular plugs are an evolving family of vessel occluders providing a single-device embolization system for large, high-flow arteries. Nitinol mesh plugs and polytetrafluoroethylene membrane plugs are available in different configurations and sizes to occlude arteries from 3 to 20 mm in diameter. Possible applications during complex endovascular aortic procedures are aortic branch embolization to prevent endoleak or to gain an adequate landing zone, directional branch occlusion, and false lumen embolization in aortic dissection. Plugs are delivered through catheters or introducers, and their technical and clinical results are comparable to those of coil embolization. Plugs are more accurate than coils as repositionable devices, less prone to migration, and have fewer blooming artifacts on postoperative computed tomography imaging. Their main drawback is the need for larger delivery systems. This narrative review describes up-to-date techniques and technology for plug embolization in complex aortic repair.

3.
Ann Surg ; 279(6): 961-972, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38214159

RESUMO

OBJECTIVE: To provide an updated systematic review and meta-analysis with meta-regression of efficacy and safety of fenestrated/branched endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) compared with open repair. BACKGROUND: Endovascular repair of TAAAs may be a promising alternative to open surgery by reducing invasiveness and expanding the eligible population, but evidence remains limited. METHODS: We applied "Prepared Items for Systematic Reviews and Meta-analysis" guidelines to retrieve, quantitatively pool, and critically evaluate the efficacy and safety (including 30-day mortality, reintervention, spinal cord injury [SCI], and renal injury) of both approaches. Original studies were retrieved from PubMed, Embase, and Cochrane Library until April 20, 2022, excluding papers reporting <10 patients. Pooled proportions and means were determined using a random-effect model. Heterogeneity between studies was evaluated with I2 statistics. RESULTS: Sixty-four studies met the predefined inclusion criteria. Endovascular cohort patients were older and had higher rates of comorbidities. Endovascular repair was associated with similar proportions of mortality (0.07, 95% confidence intervals [CI]: 0.06-0.08) compared with open repair (0.09, 95% CI: 0.08-0.12; P = 0.22), higher proportions of reintervention (0.19, 95% CI: 0.13-0.26 vs 0.06, 95% CI: 0.04-0.10; P < 0.01), similar proportions of transient SCI (0.07, 95% CI: 0.05-0.09 vs 0.06, 95% CI: 0.05-0.08; P = 0.28), lower proportions of permanent SCI (0.04, 95% CI: 0.03-0.05 vs 0.06, 95% CI: 0.05-0.07; P < 0.01), and renal injury (0.08, 95% CI: 0.06-0.10 vs 0.13, 95% CI: 0.09-0.17; P = 0.02). Results were affected by high heterogeneity and potential publication bias. CONCLUSIONS: Despite these limitations and the lack of randomized trials, this meta-analysis suggests that endovascular TAAA repair could be a safer alternative to the open approach.


Assuntos
Aneurisma da Aorta Torácica , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Aneurisma da Aorta Toracoabdominal
4.
J Endovasc Ther ; : 15266028231217233, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38062565

RESUMO

OBJECTIVE: To report on the recommendations of an expert-based consensus on the indications, timing, and techniques of aortic balloon occlusion (ABO) in the management of ruptured abdominal aortic aneurysms (rAAA). METHODS: Eleven facilitators created appropriate statements regarding the study issues that were voted on using a 4-point Likert scale with open-comment fields, by a selected panel of international experts (vascular surgeons and interventional radiologists) using a 3-round modified Delphi consensus procedure (study period: January-April 2023). Based on the experts' responses, only the statements reaching grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final study report. The consistency of each round's answers was also graded using Cohen's kappa, the intraclass correlation coefficient, and, in case of double resubmission, Fleiss kappa. RESULTS: Sixty-three experts were included in the final analysis and voted on 25 statements related to indication and timing (n=6), and techniques (n=19) of ABO in the setting of rAAA. Femoral sheath or ABO should be preferably placed in the operating room, via a percutaneous transfemoral access, on a stiff wire (grade B, consistency I), ABO placement should be suprarenal and last less than 30 minutes (grade B, consistency II), postoperative peripheral vascular status (grade A, consistency II) and laboratory testing every 6 to 12 hours (grade B, consistency) should be assessed to detect complications. Formal training for ABO should be implemented (grade B, consistency I). Most of the statements in this international expert-based Delphi consensus study might guide current choices for indications, timing, and techniques of ABO in the management of rAAA. Clinical practice guidelines should incorporate dedicated statements that can guide clinicians in decision-making. CONCLUSIONS: At arrival and during both open or endovascular procedures for rAAA, selective use of intra-aortic balloon occlusion is recommended, and it should be performed preferably by the treating physician in aortic pathology. CLINICAL IMPACT: This is the first consensus study of international vascular experts aimed at defining the indications, timing, and techniques of optimal use of ABO in the clinical setting of rAAA. Aortic occlusion by endovascular means (or ABO) is a quick procedure in properly trained hands that may play an important role as a temporizing measure until the definitive aortic repair is achieved, whether by endovascular or open means. Since data on its use in hemodynamically unstable patients are limited in the literature, owing to practical challenges in the performance of well-conducted prospective studies, understanding real-world use by experts is of importance in addressing critical issues and identifying main gaps in knowledge.

6.
J Endovasc Ther ; : 15266028231202456, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37750487

RESUMO

PURPOSE: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT: Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.

7.
Semin Vasc Surg ; 36(2): 174-188, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330232

RESUMO

For a long time, parallel grafting, physician-modified endografts, and, more recently, in situ fenestration were the only go-to endovascular options for ruptured thoracoabdominal aortic aneurysm, offered mixed results, and depended mainly on the operator's and center's experience. As custom-made devices have become an established endovascular treatment option for elective thoracoabdominal aortic aneurysm, they are not a viable option in the emergency setting, as endograft production can take up to 4 months. The development of off-the-shelf (OTS) multibranched devices with a standardized configuration has allowed the treatment of ruptured thoracoabdominal aortic aneurysm with emergent branched endovascular procedures. The Zenith t-Branch device (Cook Medical) was the first readily available graft outside the United States to receive the CE mark (in 2012) and is currently the most studied device for those indications. A new device, the E-nside thoracoabdominal branch endoprosthesis OTS multibranched endograft (Artivion), has been made commercially available, and the GORE EXCLUDER thoracoabdominal branch endoprosthesis OTS multibranched endograft (W. L. Gore and Associates) is expected to be released in 2023. Due to the lack of guidelines on ruptured thoracoabdominal aortic aneurysm, this review summarizes the available treatment options (ie, parallel grafts, physician-modified endografts, in situ fenestrations, and OTS multibranched devices), compares the indications and contraindications, and points out the evidence gaps that should be filled in the next decade.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Stents , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia
8.
J Vasc Surg ; 78(2): 300-312.e3, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37076108

RESUMO

OBJECTIVE: To compare costs and effectiveness of elective open (OR) vs fenestrated/branched endovascular (ER) repair of thoracoabdominal aneurysms (TAAAs) in a high-volume center. METHODS: This single-center retrospective observational study (PRO-ENDO TAAA Study, NCT05266781) was designed as part of a larger health technology assessment analysis. All electively treated TAAAs between 2013 and 2021 were analyzed and propensity-matched. End points were clinical success, major adverse events (MAEs), hospital direct costs, and freedom from all causes and aneurysm-related mortality and reinterventions. Risk factors and outcomes were homogeneously classified according to the Society of Vascular Surgery reporting standards. Cost-effectiveness value and incremental cost-effectiveness ratio were calculated, considering the absence of MAEs as a measure of effectiveness. RESULTS: Propensity matching identified 102 pairs of patients out of 789 TAAAs. Mortality, MAE, permanent spinal cord ischemia rates, respiratory complications, cardiac complications, and renal injury were higher for OR (13% vs 5%, P = .048; 60% vs 17%, P < .001; 10% vs 3%, P = .045; 91% vs 18%, P < .001; 16% vs 6%, P = .024; 27% vs 6%, P < .001, respectively). Access complication rate (6% vs 27%; P < .001) was higher in the ER group. Intensive care unit stay was longer (P < .001) for OR, and ER patients were discharged home more frequently (3% vs 94%; P < .001). No differences in midterm end points were observed at 2 years. Despite ER reducing all the hospital cost items (-42% to -88%, P < .001), the higher expenses (P < .001) of the endovascular devices increased the overall cost of ER by 80%. Cost-effectiveness value for ER was favorable to OR (56,365 vs 64,903 €/patient) with an incremental cost-effectiveness ratio of 48,409 € per MAE saved. CONCLUSIONS: ER of TAAA reduces perioperative mortality and morbidity compared with OR, with no differences in reinterventions and survival rates at midterm follow-up. Despite the expenses for endovascular grafts, ER was found to be more cost-effective in preventing MAEs.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Análise de Custo-Efetividade , Resultado do Tratamento , Complicações Pós-Operatórias , Aneurisma/cirurgia , Fatores de Risco , Hospitais , Estudos Retrospectivos
9.
Science ; 380(6643): 398-404, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37104594

RESUMO

Integrated photonic neural networks provide a promising platform for energy-efficient, high-throughput machine learning with extensive scientific and commercial applications. Photonic neural networks efficiently transform optically encoded inputs using Mach-Zehnder interferometer mesh networks interleaved with nonlinearities. We experimentally trained a three-layer, four-port silicon photonic neural network with programmable phase shifters and optical power monitoring to solve classification tasks using "in situ backpropagation," a photonic analog of the most popular method to train conventional neural networks. We measured backpropagated gradients for phase-shifter voltages by interfering forward- and backward-propagating light and simulated in situ backpropagation for 64-port photonic neural networks trained on MNIST image recognition given errors. All experiments performed comparably to digital simulations ([Formula: see text]94% test accuracy), and energy scaling analysis indicated a route to scalable machine learning.

10.
Eur J Vasc Endovasc Surg ; 65(5): 729-737, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36740094

RESUMO

OBJECTIVE: To investigate access failure (AF) and stroke rates of aortic procedures performed with upper extremity access (UEA), and compare results of open surgical vs. percutaneous UEA techniques with closure devices. METHODS: A physician initiated, multicentre, ambispective, observational registry (SUPERAXA - NCT04589962) was carried out of patients undergoing aortic procedures requiring UEA, including transcatheter aortic valve replacement, aortic arch, and thoraco-abdominal aortic endovascular repair, pararenal parallel grafts, renovisceral and iliac vessel repair. Only vascular procedures performed with an open surgical or percutaneous (with a suture mediated vessel closure device) UEA were analysed. Risk factors and endpoints were classified according to the Society for Vascular Surgery and VARC-3 (Valve Academic Research Consortium) reporting standards. A logistic regression model was used to identify AF and stroke risk predictors, and propensity matching was employed to compare the UEA closure techniques. RESULTS: Sixteen centres registered 1 098 patients (806 men [73.4%]; median age 74 years, interquartile range 69 - 79 years) undergoing vascular procedures using open surgical (76%) or percutaneous (24%) UEA. Overall AF and stroke rates were 6.8% and 3.0%, respectively. Independent predictors of AF by multivariable analysis included pacemaker ipsilateral to the access (odds ratio [OR] 3.8, 95% confidence interval [CI] 1.2 - 12.1; p = .026), branched and fenestrated procedure (OR 3.4, 95% CI 1.2 - 9.6; p = .019) and introducer internal diameter ≥ 14 F (OR 6.6, 95% CI 2.1 - 20.7; p = .001). Stroke was associated with female sex (OR 3.4, 95% CI 1.3 - 9.0; p = .013), vessel diameter > 7 mm (OR 3.9, 95% CI 1.1 - 13.8; p = .037), and aortic arch procedure (OR 7.3, 95% CI 1.7 - 31.1; p = .007). After 1:1 propensity matching, there was no difference between open surgical and percutaneous cohorts. However, a statistically significantly higher number of adjunctive endovascular procedures was recorded in the percutaneous cohort (p < .001). CONCLUSION: AF and stroke rates during complex aortic procedures employing UEA are non-negligible. Therefore, selective use of UEA is warranted. Percutaneous access with vessel closure devices is associated with similar complication rates, but more adjunctive endovascular procedures are required to avoid surgical exposure.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Resultado do Tratamento , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Extremidade Superior/irrigação sanguínea , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular
11.
Opt Lett ; 48(2): 460-463, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36638483

RESUMO

Continuously variable true-time optical delay lines are typically subject to a constraint of the bandwidth-delay product, limiting their use in several applications. In this Letter, we propose an integrated topology that breaks the bandwidth-delay product limit. The device is based on multiple Mach-Zehnder Interferometers (MZIs) arranged in parallel, providing easier control and a larger bandwidth compared to ring resonator-based solutions. The functionality of this architecture is demonstrated with a 4-stage delay line by performing measurements in both the time and frequency domains. The delay line introduces a delay of 90 ps over a bandwidth of more than 22 GHz with a negligible group delay distortion, operates on a wavelength range of about 60 nm, and is scalable to a higher number of MZI stages.

12.
J Endovasc Ther ; 30(2): 281-288, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35236159

RESUMO

PURPOSE: The aim of this study is to report an Italian multicenter experience analyzing the incidence and the risk factors associated with spinal cord ischemia (SCI) in a large cohort of thoracoabdominal aortic aneurysms (TAAAs) treated by fenestrated-branched endovascular aneurysm repair (F-/B-EVAR). MATERIALS AND METHODS: All consecutive patients undergoing F-/B-EVAR in 4 Italian university centers between 2008 and 2019 were prospectively recorded and retrospectively analyzed. Spinal cord ischemia, 30 day/in-hospital adverse events, and mortality were assessed as early outcomes. Risk factors for SCI were determined by multivariable analysis. RESULTS: A total of 351 patients received F-/B-EVAR for a TAAA. Twenty-eight (8.0%) patients died within 30 postoperative days or during the hospitalization. Regarding SCI, 47 patients (13.4%) developed neurological symptoms related to spinal cord impaired perfusion. Among them, 17 (4.8%) had a major permanent impairment. The multivariable analysis identified that SCI was associated with Crawford extent I to III (odds ratio [OR]: 20.90, p=0.004, 95% confidence interval [CI]=2.69-162.57), and with endovascular procedures performed for ruptured TAAA (OR: 5.74, p=0.010, 95% CI=1.53-21.57). Spinal cord ischemia was also significantly associated with a grade 3 bleeding during the visceral stage (OR: 4.34, p=0.005, 95% CI=1.55-12.16) and a grade 2 renal insufficiency at 30 days (OR: 7.45, p=0.002, 95% CI=2.12-26.18). CONCLUSION: The present study indicates that SCI is still an open issue after extent I to III TAAA endovascular repair, while its incidence in extent IV TAAA and pararenal/juxtarenal aneurysms is rare. Thoracoabdominal aortic aneurysms extension, urgent TAAA repair for rupture, severe bleeding, and 30 day renal insufficiency have been identified as significant risk factors for SCI. In the presence of such factors, adjunctive strategies may be considered to reduce SCI rates, while in low-risk patients invasive or potentially-risky maneuvers might not be justified.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal , Isquemia do Cordão Espinal , Humanos , Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Isquemia do Cordão Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/epidemiologia , Isquemia do Cordão Espinal/etiologia , Fatores de Risco , Insuficiência Renal/complicações , Insuficiência Renal/cirurgia , Sistema de Registros
13.
Aorta (Stamford) ; 10(4): 162-168, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36521807

RESUMO

Open conversion of thoracoabdominal aortic (TAA) disease after failed attempts of endovascular treatment is increasingly required. The main causes are endoleak, endograft failure, infection, disease progression, or persistent false lumen perfusion in dissected aortas. Mortality and morbidity rates are high, higher than after standard TAA open repair. Therefore, this surgery should be performed only in dedicated centers by experienced teams. Specific perioperative organ protection protocols, as well as surgical techniques, are crucial to guarantee acceptable results.

14.
Opt Express ; 30(15): 26628-26638, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236851

RESUMO

We demonstrate a temperature and wavelength shift resilient silicon transmission and routing interconnect system suitable for multi-socket interconnects, utilizing a dual-strategy CLIPP feedback circuitry that safeguards the operating point of the constituent photonic building blocks along the entire on-chip transmission-multiplexing-routing chain. The control circuit leverages a novel control power-independent and calibration-free locking strategy that exploits the 2nd derivative of ring resonator modulators (RMs) transfer function to lock them close to the point of minimum transmission penalty. The system performance was evaluated on an integrated Silicon Photonics 2-socket demonstrator, enforcing control over a chain of RM-MUX-AWGR resonant structures and stressed against thermal and wavelength shift perturbations. The thermal and wavelength stress tests ranged from 27°C to 36°C and 1309.90 nm to 1310.85 nm and revealed average eye diagrams Q-factor values of 5.8 and 5.9 respectively, validating the system robustness to unstable environments and fabrication variations.

15.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36190336

RESUMO

OBJECTIVES: The aim of this study was to assess the approaches to reno-visceral target vessels (TVs) cannulation during branched-fenestrated endovascular aortic repair, determine the evidence base that links these approaches to clinical outcomes and identify literature gaps. METHODS: A scoping review following the PRISMA Protocols Extension for Scoping Reviews was performed. Available full-text studies published in English (PubMed, Cochrane and EMBASE databases; last queried, 31 June 2022) were systematically reviewed and analysed. Data were reported as descriptive narrative or tables, without any statistical analysis nor quality assessment. RESULTS: Fourteen retrospective articles were included. Seven articles studied the use of upper extremity access (UEA) during branched-fenestrated endovascular aortic repair, 3 studied the use of steerable sheaths and 4 included both approaches. A left UEA was used in 757 patients (technical success: 99%, stroke rate: 1-3%) and a right UEA in 215 patients (technical success: 92-98%, stroke rate: 0-13%). Seven studies (1066 patients) described a surgical access only (technical success: 80-99%, stroke rate: 0-13%), while 3 studies (146 patients) described a percutaneous access only (technical success: 83-90%, stroke rate: 3%) and lastly 4 studies compared UEA versus use of steerable sheaths from the transfemoral approach (TFA) (UEA: 563 patients, technical success: 95-98%, stroke rate: 1-8%; TFA: 209 patients, technical success: 98-100%, stroke rate: 0-1%). CONCLUSIONS: Both UEA and TFA as cannulation approaches were associated with high technical success and low perioperative complications. Currently, there is a paucity of high-quality data to provide definitive indication. Optimal UEA in terms of side (left versus right) and approach (surgical versus percutaneous) needs further study.


Assuntos
Cateterismo , Procedimentos Endovasculares , Humanos , Cateterismo/efeitos adversos , Cateterismo/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos
16.
Int Angiol ; 41(5): 444-453, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35913078

RESUMO

BACKGROUND: To face the "first wave" of the pandemic (01/03/2020-15/05/2020), Lombardy's healthcare system was reorganized according to the "Hub-and-Spoke" model, and deferrable inpatient and outpatient activities were suspended. The limitations imposed by COVID-19, associated with patients' fear of presenting to medical attention, may have led to a delay in diagnosis and treatment of time-dependent pathologies. Our multicenter retrospective cohort study aims at analyzing the impact on COVID-negative patients of the shift of medical resources in Lombardy, the Italian epicenter of the pandemic. METHODS: Inclusion criteria were an age ≥18, COVID-negative condition, and referral to IRCCS Istituto Clinico Humanitas - Rozzano, Milan (Spoke Center) or IRCCS Ospedale San Raffaele - Milan (Hub Center) for acute vascular diseases requiring urgent treatment. SARS-CoV-2 infection, either on admission or during hospitalization, was the exclusion criterion. Data of the "first wave" were compared with the corresponding months of 2019, to highlight differences in vascular pathologies' case rates, clinical presentation, treatment type and post-treatment outcomes (mortality, rate of adverse events, primary and secondary clinical success and of amputation). RESULTS: Two hundred and two patients were treated for acute vascular diseases, 52 in 2019, 150 in 2020 (P<0.001). A later presentation to medical attention (4.3 versus 5.9 days after symptoms onset, P=0.03) and an increased need for urgent treatment for peripheral arterial disease (P=0.04) differentiated 2020. A higher number of peripheral arterial disease patients underwent major amputations (P=0.38). Access to post-surgical rehabilitation programs was restricted (P<0.001). CONCLUSIONS: During the first wave of COVID-19 pandemic, in the face of a radical health care rearrangement, no increase in mortality nor in post-operative adverse event rate was registered. Anyway, urgent hospitalizations for vascular disease increased, more specifically for peripheral ischemia, in which late presentation may have influenced an increase in amputation rate.


Assuntos
COVID-19 , Doença Arterial Periférica , Humanos , Pandemias , COVID-19/epidemiologia , SARS-CoV-2 , Estudos Retrospectivos , Itália/epidemiologia
17.
Light Sci Appl ; 11(1): 197, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35787626

RESUMO

Free-space optics naturally offers multiple-channel communications and sensing exploitable in many applications. The different optical beams will, however, generally be overlapping at the receiver, and, especially with atmospheric turbulence or other scattering or aberrations, the arriving beam shapes may not even be known in advance. We show that such beams can be still separated in the optical domain, and simultaneously detected with negligible cross-talk, even if they share the same wavelength and polarization, and even with unknown arriving beam shapes. The kernel of the adaptive multibeam receiver presented in this work is a programmable integrated photonic processor that is coupled to free-space beams through a two-dimensional array of optical antennas. We demonstrate separation of beam pairs arriving from different directions, with overlapping spatial modes in the same direction, and even with mixing between the beams deliberately added in the path. With the circuit's optical bandwidth of more than 40 nm, this approach offers an enabling technology for the evolution of FSO from single-beam to multibeam space-division multiplexed systems in a perturbed environment, which has been a game-changing transition in fiber-optic systems.

18.
J Vasc Surg ; 76(4): 867-874, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35697307

RESUMO

OBJECTIVE: To report the outcomes of fenestrated-branched endovascular repair (FBEVAR) for thoracoabdominal aortic pathology after total aortic arch replacement with frozen elephant trunk (TAR+FET). METHODS: Interrogation of prospectively maintained databases from four high-volume aortic centers identified consecutive patients treated with distal FBEVAR after prior TAR+FET between August 2013 and September 2020. The primary end point was 30-day/in-hospital mortality. Secondary end points were technical success, early clinical success, midterm survival, and freedom from reintervention. Data are presented as median (interquartile range). RESULTS: A total of 39 patients (21 men; median age, 73 years [67-75 years]) with degenerative (n = 22) and postdissection thoracoabdominal aortic aneurysms (n = 17) (median diameter, 71 mm [61-78 mm]) were identified. Distal FBEVAR was intended in 27 patients (median interval, 9.8 months [6.2-16.6 months]), anticipated in 7, and unexpected in 5. A total of 31 patients had a two- (n = 24) or three-stage (n = 7) distal FBEVAR. Renovisceral target vessel preservation was 99.3% (145 of 146). Early primary and secondary technical success was 92% and 97%, respectively. Thirty-day mortality was 2.6% (n = 1; respiratory failure and spinal cord ischemia [SCI]). Six survivors also developed SCI, which was associated with complete (n = 4) or partial recovery (n = 2) at hospital discharge. No patients required renal replacement therapy or suffered a stroke. Early clinical success was 95%. Median follow-up was 30.5 months (23.7-49.7 months). Eleven patients required 16 late reinterventions. Estimated 3-year survival and freedom from reintervention were 84% ± 6% and 63% ± 10%, respectively. CONCLUSIONS: Distal FBEVAR after prior TAR+FET is associated with high technical success and low early mortality. The risk of SCI is significant although the majority of patients demonstrate full or partial recovery before hospital discharge. Midterm patient survival is favorable, but there remains a high requirement for late reintervention. FBEVAR represents an acceptable alternative to distal open thoracoabdominal aortic aneurysm repair.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Isquemia do Cordão Espinal/etiologia , Stents , Fatores de Tempo , Resultado do Tratamento
19.
Opt Lett ; 47(10): 2598-2601, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35561410

RESUMO

Visible-light integrated photonics is emerging as a promising technology for the realization of optical devices for applications in sensing, quantum information and communications, imaging, and displays. Among the existing photonic platforms, high-index-contrast silicon nitride (Si3N4) waveguides offer broadband transparency in the visible spectral range and a high scale of integration. As the complexity of photonic integrated circuits (PICs) increases, on-chip detectors are required to monitor their working point for reconfiguration and stabilization operations. In this Letter, we present a semi-transparent in-line power monitor integrated on Si3N4 waveguides that operates in the red-light wavelength range (660 nm). The proposed device exploits the photoconductivity of a hydrogenated amorphous-silicon (a-Si:H) film that is evanescently coupled to an optical waveguide. Experimental results show a responsivity of 30 mA/W, a sensitivity of -45 dBm, and a sub-µs time response. These features enable the use of the proposed photoconductor for high-sensitivity monitoring and control of visible-light Si3N4 PICs.

20.
Sensors (Basel) ; 22(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35590981

RESUMO

Integrated optical biosensors are gaining increasing attention for their exploitation in lab-on-chip platforms. The standard detection method is based on the measurement of the shift of some optical quantity induced by the immobilization of target molecules at the surface of an integrated optical element upon biomolecular recognition. However, this requires the acquisition of said quantity over the whole hybridization process, which can take hours, during which any external perturbation (e.g., temperature and mechanical instability) can seriously affect the measurement and contribute to a sizeable percentage of invalid tests. Here, we present a different assay concept, named Opto-Magnetic biosensing, allowing us to optically measure off-line (i.e., post hybridization) tiny variations of the effective refractive index seen by microring resonators upon immobilization of magnetic nanoparticles labelling target molecules. Bound magnetic nanoparticles are driven in oscillation by an external AC magnetic field and the corresponding modulation of the microring transfer function, due to the effective refractive index dependence on the position of the particles above the ring, is recorded using a lock-in technique. For a model system of DNA biomolecular recognition we reached a lowest detected concentration on the order of 10 pm, and data analysis shows an expected effective refractive index variation limit of detection of 7.5×10-9 RIU, in a measurement time of just a few seconds.


Assuntos
Técnicas Biossensoriais , Dispositivos Ópticos , Técnicas Biossensoriais/métodos , Fenômenos Magnéticos , Refratometria , Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...