1.
J Curr Glaucoma Pract ; 16(1): 53-58, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060038

RESUMO

Aim: To compare the usefulness of gonioscopy performed by general ophthalmologists (GO) and anterior segment optical coherence tomography (AS-OCT) in detecting angle closure in patients with a shallow anterior chamber. Methods: Forty-four patients with a shallow anterior chamber (defined by a ratio of peripheral anterior chamber depth to peripheral corneal thickness lower than 1/2) were included in this cross-sectional study. Gonioscopy was performed in all subjects by two glaucoma experts (GE1 and GE2) and one GO. Anterior segment imaging was performed using Visante® OCT (Carl Zeiss Meditec Inc.). Agreement between examiners was assessed with first-order agreement coefficients (AC1). Diagnostic accuracies of GO gonioscopy and AS-OCT were evaluated using sensitivity, specificity, and area under the receiver operating characteristic (AROC) curves. Results: For static gonioscopy, the agreement between GE1 and GE2 was substantial (AC1 = 0.65), and that between GE1 and GO was moderate (AC1 = 0.50). For indentation gonioscopy, the agreement between GE1 and GE2 was slightly lower (AC1 = 0.55); however, the agreement between GE1 and GO showed a larger reduction (AC1 = 0.12). GO's gonioscopy presented a low specificity (25%) and the AROC to angle closure detection was lower than AS-OCT (0.56-0.73). Combined information of GO gonioscopy and AS-OCT improved specificity (85.7%) and AROC (0.77) of angle closure evaluation. Conclusion: Agreement between GO and glaucoma experts was moderate for static gonioscopy and slight for indentation gonioscopy. AS-OCT performed better than GO gonioscopy in detecting angle closure in patients with a shallow anterior chamber. The addition of AS-OCT to clinical information in patients with GO positive gonioscopy improved the specificity and AROC of gonioscopy test. How to cite this article: Esporcatte BLB, Vessani RM, Melo Jr LAS, et al. Diagnostic Performance of Optical Coherence Tomography and Nonspecialist Gonioscopy to Detect Angle Closure. J Curr Glaucoma Pract 2022;16(1):53-58.

2.
Clin Exp Ophthalmol ; 37(4): 402-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19594568

RESUMO

BACKGROUND: We aimed to evaluate the ascorbic acid concentration in secondary aqueous humour (AH) from glaucomatous patients and to compare it with primary AH from primary open-angle glaucoma patients and non-glaucomatous patients. METHODS: Primary AH samples were prospectively obtained from clinically uncontrolled primary open-angle glaucoma patients and senile cataract patients (controls) prior to trabeculectomy and cataract surgery. Secondary AH samples were obtained from eyes with previous intraocular surgery, prior to trabeculectomy or cataract surgery. AH (0.1 mL) was aspirated by inserting a 26-gauge needle into the anterior chamber just before surgery and then immediately stored at -80 degrees C. The ascorbic acid concentration was determined in a masked fashion by high-pressure liquid chromatography. RESULTS: A total of 18 patients with senile cataract, 16 glaucomatous patients with primary AH (no previous intraocular surgery) and 11 glaucomatous patients with secondary AH (previous intraocular surgery) were included. There was no difference in mean age between groups (P = 0.15). The mean +/- standard deviation concentration of ascorbic acid in the secondary AH from glaucomatous patients (504 +/- 213 micromol/L [95% confidence interval {CI}, 383-624]) was significantly lower than the concentration of ascorbic acid found in the primary aqueous of primary open-angle glaucoma (919 +/- 427 micromol/L [95% CI, 709-1128]) and control patients (1049 +/- 433 micromol/L [95% CI, 848-1249]; P < 0.01, Kruskal-Wallis test). CONCLUSIONS: The ascorbic acid concentration in secondary AH of glaucomatous patients was approximately twofold lower in comparison with primary AH of glaucomatous and cataract patients. The implications of a reduced concentration of ascorbic acid in the secondary AH deserve further investigation.


Assuntos
Humor Aquoso/metabolismo , Ácido Ascórbico/metabolismo , Glaucoma de Ângulo Aberto/metabolismo , Idoso , Extração de Catarata , Cromatografia Líquida de Alta Pressão , Feminino , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Masculino , Estudos Prospectivos , Trabeculectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA