Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Interv Card Electrophysiol ; 62(3): 469-477, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33963500

RESUMO

PURPOSE: The PAINESD risk score was developed in 2015 as a tool to stratify the risk of acute hemodynamic decompensation during ventricular tachycardia (VT) ablation in structural heart disease patients and further then used for post procedure 30-day mortality prediction. The original cohort however did not include Chagas disease (ChD) patients. We aim to evaluate the relevance of the score in a ChD population. METHODS: The PAINESD risk score gives weighted values for specific characteristics (chronic obstructive pulmonary disease, age > 60 years, ischemic cardiomyopathy, New York Heart Association [NYHA] functional class 3 or 4, ejection fraction less than 25%, VT storm, and diabetes). The score was applied in a retrospective cohort of ChD VT ablations in a single tertiary center in Brazil. Data were collected by VT study reports and patient record analysis at baseline and on follow-up. RESULTS: Between January 2013 and December 2018, 157 VT catheter ablation procedures in 121 ChD patients were analyzed. Overall, 30-day mortality was 9.0%. Multivariate analysis correlated NYHA functional class (HR 1.78, 95% CI 1.03-3.08, P 0.038) and the need for urgent surgery (HR 31.5, 95% CI 5.38-184.98, P < 0.001), as well as a tendency for VT storm at presentation (HR 2.72, 95% CI 0.87-8.50, P 0.084) as risk factors for the primary endpoint. The median PAINESD risk score in this population was 3 (3-8). The area under the receiver operating characteristic (ROC) curve was 0.64 (95% CI 0.479-0.814). CONCLUSIONS: The PAINESD risk score did not perform well in predicting 30-day mortality in ChD patients. Pre-procedure NYHA functional class and the need for urgent surgery due to refractory pericardial bleeding were independently associated with increased 30-day mortality. Prospective studies are needed to take final conclusions in Chagas disease when using PAINESD score.


Assuntos
Ablação por Cateter , Doença de Chagas , Taquicardia Ventricular , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
2.
Int Endod J ; 50(6): 586-594, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27132802

RESUMO

AIM: To investigate how the exposure parameters used when producing CBCT scans affect diagnostic accuracy when detecting simulated vertical root fractures and how various filling materials affect image quality. METHODOLOGY: A total of 160 extracted single-rooted human teeth were divided into four groups based on the materials within the root canals: unrestored, gutta-percha, metallic post and fibreglass post. Half of the sample of each group was selected for the induction of vertical root fractures. Each tooth was placed in an empty socket of a dry skull which was scanned on a CBCT unit (9000 3D scanner; Kodak Dental Systems, Carestream Health, Rochester, NY, USA) using the following exposure parameters: 74 kV/12 mA; 74 kV/10 mA; 74 kV/8 mA; 74 kV/6.3 mA; 70 kV/12 mA; 70 kV/10 mA; 70 kV/8 mA; 70 kV/6.3 mA. Two observers assessed all images using a 5-point confidence scale for fracture detection and a 4-point score for the presence of artefacts. Sensitivity, specificity, accuracy and area under ROC curve were compared by two-way anova and Tukey's test. Artefact formation was evaluated by descriptive statistics. RESULTS: There were no significant differences in the sensitivity (P = 0.370), specificity (P = 0.660), accuracy (P = 0.084) and area under the ROC curve (P = 0.674) values amongst the various exposure parameters within the same group. There were some significant differences when the groups were compared for each intracanal material. The sensitivity and accuracy of the group containing metallic posts were significantly lower than the unrestored and fibreglass post groups (P ≤ 0.017). CONCLUSION: The variations in exposure parameters did not interfere with the diagnosis of vertical root fractures, independent of the root canal restorative status. Metallic posts were associated with greater artefact formation and compromised the diagnostic performance. It is possible to decrease the kVp/mA settings to reduce the probability of biological effects due to radiation, without losing diagnostic accuracy.


Assuntos
Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/lesões , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/diagnóstico por imagem , Vidro , Guta-Percha , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Fraturas dos Dentes/diagnóstico , Raiz Dentária/diagnóstico por imagem
4.
Int Endod J ; 49(5): 500-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26033046

RESUMO

AIM: To evaluate the influence of an artefact reduction algorithm (ARA) and several root filling materials on the detection of root fractures on cone-beam computed tomography (CBCT) images. METHODOLOGY: Forty-four teeth were divided into control and fractured groups and scanned on a Picasso Trio CBCT device under four conditions: unrestored, filled with gutta-percha cones, cast-gold or fibreglass posts; either with or without applying the ARA. Three calibrated examiners assessed the images. ROC analysis, anova and pairwise Tukey LSD test were performed. RESULTS: No significant difference between the groups with and without the ARA was observed. There was no significant interaction between the algorithm and root condition. On the other hand, there was a significant difference in the mean values of sensitivity (Sn) and accuracy (Ac) amongst the different root filling groups (P ≤ 0.001). CONCLUSIONS: The application of the ARA did not influence the diagnosis of root fractures, and its effects did not depend on root conditions. In relation to the filling materials, gold posts reduced the overall CBCT diagnostic ability, regardless of the use of the ARA.


Assuntos
Algoritmos , Artefatos , Fraturas dos Dentes/diagnóstico , Raiz Dentária , Guta-Percha , Humanos
5.
Dentomaxillofac Radiol ; 44(7): 20150023, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25806865

RESUMO

OBJECTIVES: The aim was to evaluate the morphology of the temporomandibular joint's (TMJs) disc and condyle as well as its correlation with disc displacement, using MRI. METHODS: 190 TMJs were retrospectively analysed. The condyle morphology of each TMJ was evaluated by two observers using both axial and coronal views, as were their disc morphology and displacement, using sagittal view. Condyle morphology was classified as flat, convex, angled or rounded in the coronal sections and as anterior side flat/posterior side convex, biconvex, anterior side concave/posterior side convex, flat or biconcave in the axial view. Disc morphology was determined as biconcave, biplanar, biconvex, hemiconvex or folded. χ2, Fisher exact and Bonferroni correction tests were used to evaluate the data. ANOVA followed by post hoc Tukey's test was used to evaluate the interaction between age and disc displacement. RESULTS: Anterior disc displacement with reduction; convex condyle morphology in the coronal view; anterior side concave/posterior side convex morphology in the axial view; and biconcave discs were found to be the most prevalent findings. An association was observed between disc morphology and disc displacement (p<0.001). No correlation between condyle morphology and TMJ disc displacement was found (p=0.291 for axial and p=0.14 for coronal views). CONCLUSIONS: The results of this study suggest that TMJ disc morphology is associated with disc displacement.


Assuntos
Imageamento por Ressonância Magnética/métodos , Disco da Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Dentomaxillofac Radiol ; 42(9): 20120459, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23906974

RESUMO

OBJECTIVES: To evaluate the effect on diagnostic yield in the detection of experimentally induced vertical root fractures on cone beam CT images using four dental software program. METHODS: 190 single-rooted extracted human teeth were divided into three groups according to the pulp canal status: unrestored (UR), filled with gutta-percha (GP) and restored with a metallic custom post (Post). One-half of the sample of each group was artificially fractured and the segments repositioned. All teeth were scanned on a cone beam CT device at 0.2 mm nominal voxel resolution (i-CAT Platinum; Imaging Sciences International, Hatfield, PA). The data were exported as digital imaging and communications in medicine files and imported into Dolphin Imaging & Management Solutions, v. 11.5 (Patterson Dental Supply Inc., St Paul, MN), InVivoDental, v. 5.0 (Anatomage Inc., San Jose, CA) and Kodak Dental Imaging Software 3D module, v. 2.1.11 (Carestream Health Inc., Rochester, NY) software. Cross-sectional images in the acquisition (using Xoran CAT™, v. 3.0.34 software; Xoran Technologies, Ann Arbor, MI) and additional software were presented to three calibrated oral radiologists who rated the presence or absence of root fracture on a five-point scale. Receiver operating characteristic analysis was performed, and treatment comparisons compared by analysis of variance and pairwise comparisons were performed using Tukey's test at an a priori value of α < 0.05%. RESULTS: All dental software performed equally at detecting fractures. Fractures were significantly more difficult to detect when posts were present. CONCLUSIONS: The diagnosis of root fracture is software-independent. The presence of an intracanal metallic post significantly decreases the detection of artificially created root fractures.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/lesões , Análise de Variância , Cavidade Pulpar/diagnóstico por imagem , Humanos , Técnica para Retentor Intrarradicular , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sistemas de Informação em Radiologia , Obturação do Canal Radicular , Estatísticas não Paramétricas , Fraturas dos Dentes/patologia
7.
Clin Anat ; 25(5): 650-5, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22674644

RESUMO

Bifid mandibular condyle (BMC) is a rare asymptomatic morphological alteration with no predilection for age group or gender. Its morphology varies from a shallow groove to two condylar heads with separate necks, oriented mediolaterally or anteroposteriorly. This report describes an unusual case of anteroposterior bifid condyle in a 39-year-old female patient with the main complaint of mouth-opening limitation and a deviation of the mandible to the left side. Magnetic resonance imaging (MRI) findings revealed a bifid condyle on the left side and duplicated mandibular fossa, with the articular disc over the anterior head. The MRI images in the open-mouth position revealed minimal movement of the condyle. Despite the increased number of mediolateral bifid mandibular condyle cases described in the literature, none of previously reported cases of BMC included an anteroposterior bifid condyle case with two distinct mandibular fossa.


Assuntos
Anormalidades Maxilomandibulares/diagnóstico , Côndilo Mandibular/anormalidades , Côndilo Mandibular/patologia , Adulto , Feminino , Humanos , Anormalidades Maxilomandibulares/patologia , Imageamento por Ressonância Magnética , Amplitude de Movimento Articular/fisiologia , Articulação Temporomandibular/patologia , Articulação Temporomandibular/fisiopatologia
8.
Ecotoxicol Environ Saf ; 66(3): 412-20, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16483651

RESUMO

The present study investigated the feasibility of the use of the burrowing amphipod Tiburonella viscana for sediment toxicity assessments. The effects of reference toxicants, salinity, sediment particle size, and sediment contamination on amphipod survival were analyzed. The sensitivity of T. viscana to zinc, chromium, and sodium dodecyl sulfate (SDS) in acute tests was similar to that of other crustaceans. The 48-h LC(50) (lethal concentration to 50% of the test organisms in a 48-h exposure) values for T. viscana (95% confidence intervals in parenthesis) were 0.79 (0.56-1.12), 5.85 (4.9-7.0), and 3.41 (2.87-4.04) mg L(-1) for zinc, chromium, and SDS, respectively. The species tolerated salinity as low as 19 ppt under laboratory conditions, indicating its suitability for use in tests with some estuarine sediments. The survival of T. viscana was not affected by grain size in field-collected sediments ranging from 60.6% silt and clay to 95.5% sand, but survival was significantly reduced in laboratory-sieved sediments containing only one or two particle sizes, e.g., only medium and coarse sand, or medium sand, or fine sand, or only fines, suggesting that a mixed grain size distribution is necessary for amphipod survival.


Assuntos
Anfípodes/efeitos dos fármacos , Sedimentos Geológicos , Testes de Toxicidade/métodos , Poluentes da Água/toxicidade , Animais , Brasil , Carbono/análise , Monitoramento Ambiental , Hidrocarbonetos/toxicidade , Dose Letal Mediana , Metais Pesados/toxicidade , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...