Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Ultrasonics ; 138: 107239, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211366

RESUMO

A toroidal high-intensity focused ultrasound (HIFU) transducer was used to expose normal bladder wall tissues non-invasively in vivo in a porcine model in order to investigate the potential to treat bladder tumors. The transducer was divided into 32 concentric rings with equal surface areas, operating at 2.5 MHz. Eight animals were split into two groups of 4. In the first group, post-mortem evaluation was performed immediately after ultrasound exposure. In the second group, animals survived for up to seven days before post-mortem evaluation. The ultrasound imaging guided HIFU device was hand-held during the procedure using optical tracking to ensure correct targeting. One thermal lesion in each animal was created using a 40 s exposure at 80 acoustic Watts (free-field) in the trigone region of the bladder wall. The average (±Standard Deviation) abdominal wall and bladder wall thicknesses were 10.3 ± 1.4 mm and 1.1 ± 0.4 mm respectively. The longest and shortest axes of the HIFU ablations were 7.7 ± 2.9 mm and 6.0 ± 1.8 mm, respectively, resulting in an ablation of the whole thickness of the bladder wall in most cases. Ablation were performed at an average depth (distance from the skin surface to the centre of the HIFU lesion) of 42.5 ± 3.8 mm and extended throughout the thickness of the bladder. There were two cases of injury to tissues immediately adjacent to the bladder wall but without signs of perforation, as confirmed by histological analysis. Non-invasive HIFU ablation using a hand-held toroidal transducer was successfully performed to destroy regions of the bladder wall in vivo.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Bexiga Urinária , Suínos , Animais , Bexiga Urinária/cirurgia , Ultrassonografia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Transdutores
2.
Med Phys ; 50(11): 6908-6919, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37769022

RESUMO

BACKGROUND: Understanding the changes occurring in biological tissue during thermal ablation is at the heart of many current challenges in both therapy and medical imaging research. PURPOSE: The objective of this work is to quantitatively interpret the scattering response of human liver samples, before and after thermal ablation. We report acoustic measurements performed involving n = 21 human liver samples. Thermal ablation is achieved at temperatures between 45 and 80°C and quantification of the irreversible changes in acoustic attenuation and Backscattering Coefficient (BSC) is reported, with a particular attention to the latter. METHODS: Both attenuation coefficient and BSCs were measured in the frequency range from 10 to 52 MHz. Scans were performed before heating and after cooling down. Attenuation coefficients were calculated using spectral difference method and BSC estimated using the reference phantom method. RESULTS: Strong increases of attenuation coefficients and BSCs with heating temperature were observed. Quantitative ultrasonic parameters obtained with the polydisperse structure factor model (poly-SFM)are compared to histological observations and seen to be close to hepatocyte mean diameter (HMD). CONCLUSIONS: The results presented in this study provide a description of the impact of thermal ablation in human liver tissue on acoustic attenuation and the BSC. For the first time, quantitative agreement between the Effective Scatterer Diameter (ESD) estimated from BSC and HMD was shown, highlighting the important role of cellular network in the scattering response of the medium. This core result is an important step toward the determination of the nature of scattering sources in biological tissues.


Assuntos
Temperatura Baixa , Fígado , Humanos , Ultrassonografia/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imagens de Fantasmas , Coração
3.
Ultrasound Med Biol ; 49(8): 1845-1851, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37268553

RESUMO

OBJECTIVE: High-intensity focused ultrasound (HIFU) is a recent, non-ionizing and non-invasive technology of focal destruction. Independence from the heat-sink effect of blood flow makes HIFU an interesting technique for focal ablation of liver tumors. Current available technology is based on extracorporeal treatment that limits use of HIFU for the treatment of liver tumors, as elementary ablations are small and must be juxtaposed to treat tumors, resulting in long-duration treatment. We developed an HIFU probe with toroidal technology, which increases the volume of ablation, for intra-operative use, and we assessed the feasibility and efficacy of this device in patients with colorectal liver metastasis (CLM) measuring less than 30 mm. METHODS: This study was an ablate-and-resect, prospective, single-center, phase II study. All ablations were performed in the area of liver scheduled for liver resection to avoid loss of chance of recovery. The primary objective was to ablate CLM with safety margins (>5 mm). RESULTS: Between May 2014 and July 2020, 15 patients were enrolled and 24 CLM were targeted. The HIFU ablation time was 370 s. In total, 23 of 24 CLM were successfully treated (95.8%). No damage occurred to extrahepatic tissues. HIFU ablations were oblate shaped with an average long axis of 44.3 ± 6.1 mm and an average shortest axis of 35.9 ± 6.7 mm. On pathological examination, the average diameter of the treated metastasis was 12.2 ± 4.8 mm. CONCLUSION: Intra-operative HIFU can safely and accurately produce large ablations in 6 min with real-time guidance (ClinicalTrials.gov identifier: NCT01489787).


Assuntos
Neoplasias Colorretais , Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Hepáticas , Humanos , Estudos Prospectivos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Hepatectomia/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Neoplasias Colorretais/patologia
4.
Ultrasound Med Biol ; 49(1): 212-224, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36441030

RESUMO

A toroidal high-intensity focused ultrasound (HIFU) transducer was used to non-invasively treat liver tissues in vivo in a pig model. The transducer was divided into 32 concentric rings with equal surface areas operating at 2.5 MHz. First, attenuation of skin, fat, muscle and liver tissues was measured in fresh animal samples to adjust the energy delivered to the focal zone. Then, 8 animals were included in the present protocol and placed in a dorsal decubitus proclive position at an angle of 15°. The device was held by hand, and sonications were performed during apnea. Two thermal HIFU lesions were created in 40 s in each animal. The average abdominal wall thickness was 14.8 ± 1.3 mm (12.5-17.6 mm). The longest and shortest axes of the HIFU ablations were 20.9 ± 6.3 mm (14.0-33.7 mm) and 14.2 ± 5.5 mm (7.0-22.0 mm), respectively. All HIFU lesions were visible on sonograms. The correlation between the dimensions of the HIFU lesions observed on sonograms and those obtained during gross examination was r = 0.84. Creating large and fast ablations with reliable ultrasound imaging guidance in the liver using this handheld device may represent a new therapeutic option for patients with liver tumors.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Hepáticas , Suínos , Animais , Transdutores , Mãos
5.
Cancers (Basel) ; 14(11)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35681557

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) diagnosis accompanies a somber prognosis for the patient, with dismal survival odds: 5% at 5 years. Despite extensive research, PDAC is expected to become the second leading cause of mortality by cancer by 2030. Ultrasound (US) has been used successfully in treating other types of cancer and evidence is flourishing that it could benefit PDAC patients. High-intensity focused US (HIFU) is currently used for pain management in palliative care. In addition, clinical work is being performed to use US to downstage borderline resectable tumors and increase the proportion of patients eligible for surgical ablation. Focused US (FUS) can also induce mechanical effects, which may elicit an anti-tumor response through disruption of the stroma and can be used for targeted drug delivery. More recently, sonodynamic therapy (akin to photodynamic therapy) and immunomodulation have brought new perspectives in treating PDAC. The aim of this review is to summarize the current state of those techniques and share our opinion on their future and challenges.

6.
Cancers (Basel) ; 13(24)2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34945001

RESUMO

Apart from palliative chemotherapy, no other therapy has been proven effective for the treatment of locally advanced pancreatic tumors. In this study, an intraoperative high-intensity focused ultrasound (HIFU) device was tested in vivo to demonstrate the feasibility of treating the pancreatic parenchyma and tissues surrounding the superior mesenteric vessels prior to clinical translation of this technique. Twenty pigs were included and treated using a HIFU device equipped with a toroidal transducer and an integrated ultrasound imaging probe. Treatments were performed with energy escalation (from 30 kJ to 52 kJ). All treatments resulted in visible (macroscopically and in ultrasound images) homogeneous thermal damage, which was confirmed by histology. The dimensions of thermal lesions measured in ultrasound images and those measured macroscopically were correlated (r = 0.82, p < 0.05). No arterial spasms or occlusion were observed at the lowest energy setting. Temporary spasm of the peripancreatic artery was observed when using an energy setting greater than 30 kJ. The possibility of treating the pancreas and tissues around mesenteric vessels without vascular thrombosis holds great promise for the treatment of locally advanced pancreatic cancers. If clinically successful, chemotherapy followed by HIFU treatment could rapidly become a novel treatment option for locally advanced pancreatic cancer.

7.
Ultrasound Med Biol ; 47(7): 1761-1774, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33895037

RESUMO

Primary and secondary liver tumors are completely different diseases but are usually treated similarly using high-intensity focused ultrasound (HIFU). However, the acoustic parameters of these tissues are not well documented. In this study, attenuation coefficients were evaluated in fresh primary (N = 8) and secondary (N = 13) human liver tumor samples recovered by hepatectomy. The average attenuation coefficients of the primary and secondary liver tumors were 0.10 ± 0.03 and 0.20 ± 0.04 Np/cm/MHz, respectively. The average attenuation coefficients of the liver tissue surrounding the primary and secondary tumors were 0.16 ± 0.07 and 0.07 ± 0.02 Np/cm/MHz, respectively. Numerical simulations performed using these values revealed that completely different HIFU ablation patterns were created in primary and secondary liver tumors using the same exposure parameters. The dimensions of a typical HIFU lesion were two times larger in secondary liver tumors than in primary tumors. HIFU treatment parameters should be set properly according to the acoustic properties of the diseased liver tissue.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Hepáticas/cirurgia , Humanos , Neoplasias Hepáticas/secundário
8.
Ultrasound Med Biol ; 46(12): 3286-3295, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32891425

RESUMO

This study demonstrated that high-intensity focused ultrasound (HIFU) produced with an intra-operative toroidal-shaped transducer causes fast, selective liver tumor ablations in an animal model. The HIFU device is composed of 256 emitters working at 3 MHz. A 7.5 MHz ultrasound imaging probe centered on the HIFU transducer guided treatment. VX2 tumor segments (25 mg) were implanted into the right lateral liver lobes of 45 New Zealand rabbits. The animals were evenly divided into groups 1 (toroidal HIFU ablation), 2 (surgical resection) and 3 (untreated control). Therapeutic responses were evaluated with gross pathology and histology 11 d post-treatment. Toroidal transducer-produced HIFU ablation (average ablation rate 10.5 cc/min) allowed fast and homogeneous tumor treatment. Sonograms showed all ablations. VX2 tumors were completely coagulated and surrounded by safety margins without surrounding-organ secondary HIFU lesions. HIFU group tumor volumes at autopsy (39 mm3) were significantly lower than control group volumes (2610 mm3, p < 0.0001). HIFU group tumor metastasis (27%) was lower than resected (33%) and control (67%) group metastasis. Ultrasound imaging, gross pathology and histology results supported these outcomes. HIFU procedures had no complications. Rabbit liver tumor ablation using a toroidal HIFU transducer under ultrasound imaging guidance might therefore be an effective intra-operative treatment for localized liver metastases.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Neoplasias Hepáticas/cirurgia , Ultrassonografia de Intervenção/instrumentação , Animais , Modelos Animais de Doenças , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Coelhos , Fatores de Tempo
9.
Ultrasound Med Biol ; 46(8): 1968-1977, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32493631

RESUMO

High-intensity focused ultrasound is a non-invasive modality for thermal ablation of tissues through locally increased temperature. Thermal lesions can be monitored by elastography, following the changes in the elastic properties of the tissue as reflected by the shear-wave velocity. Most studies on ultrasound elastography use shear waves created by acoustic radiation force. However, in the human body, the natural noise resulting from cardiac activity or arterial pulsatility can be used to characterize elasticity through noise-correlation techniques, in the method known as passive elastography. The objective of this study was to investigate the feasibility of monitoring high-intensity ultrasound treatments of liver tissue using passive elastography. Bovine livers were heated to 80°C using a high-intensity planar transducer and imaged with a high-frame-rate ultrasound imaging device. The dynamics of lesion formation are captured through tissue stiffening and lesion expansion.


Assuntos
Técnicas de Imagem por Elasticidade , Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado/cirurgia , Animais , Bovinos , Técnicas de Imagem por Elasticidade/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Temperatura Alta , Fígado/diagnóstico por imagem , Modelos Estatísticos
10.
J Vis Exp ; (143)2019 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-30688290

RESUMO

Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments performed with a curative intent. Nevertheless, several limitations have been documented when using these techniques (i.e., a traumatic puncture of the parenchyma, a limited size of lesions, and an inability to monitor the treatment in real-time).High-intensity focused ultrasound (HIFU) technology can achieve precise ablations of biological tissues without incisions or radiation. Current HIFU devices are based on an extracorporeal approach with limited access to the liver. We have developed a HIFU device designed for intraoperative use. The use of a toroidal transducer enables an ablation rate (10 cm3·min-1) higher than any other treatment and is independent of perfusion. The feasibility, safety, and accuracy of intraoperative HIFU ablation were evaluated during an ablate-and-resect prospective study. This clinical phase I and IIa study was performed in patients undergoing hepatectomy for liver metastases. The HIFU treatment was performed on healthy tissue scheduled for resection.Liver metastases measuring less than 20 mm will be targeted during phase IIb (currently ongoing). This set-up allows the real-time evaluation of HIFU ablation while protecting participating patients from any adverse effects related to this new technique. Fifteen patients were included in phase I-IIa and 30 HIFU ablations were safely created within 40 s and with a precision of 1-2 mm. The average dimensions of the HIFU ablations were 27.5 x 21.0 mm2, corresponding to a volume of approximately 7.5 cm3. The aim of the ongoing phase IIb is to ablate metastases of less than 20 mm in diameter with a 5 mm margin.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Neoplasias Hepáticas/complicações , Adulto , Estudos de Viabilidade , Humanos , Neoplasias Hepáticas/patologia , Pessoa de Meia-Idade , Metástase Neoplásica , Estudos Prospectivos
11.
Trials ; 18(1): 57, 2017 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-28166812

RESUMO

BACKGROUND: Liver resection is the only potentially curative treatment for colorectal liver metastases (LM). It is considered a safe procedure, but is often associated with blood loss during liver transection. Blood transfusions are frequently needed, but they are associated with increased morbidity and risk of recurrence. Many surgical devices have been developed to decrease blood loss. However, none of them has proven superior to the standard crushing technique. We developed a new, powerful intra-operative high-intensity focused ultrasound (HIFU) transducer which destroys tissue by coagulative necrosis. We aim to evaluate whether HIFU-assisted liver resection (HIFU-AR) results in reduced blood loss. METHODS: This is a prospective, single-centre, randomized (1:1 ratio), comparative, open-label phase II study. Patients with LM requiring a hepatectomy for ≥ 2 segments will be included. Patients with cirrhosis or sinusoidal obstruction syndrome with portal hypertension will be excluded. The primary endpoint is normalized blood loss in millilitres per square centimetre of liver section plane. Secondary endpoints are: total blood loss, transection time, transection time per square centimetre of liver area, haemostasis time, clip density on the liver section area, rate and duration of the Pringle manœuvre, rate of patients needing a blood transfusion, length of hospital stay, morbidity, patients with positive resection margin, and local recurrence. Assuming a blood loss of 7.6 ± 3.7 mL/cm2 among controls, the study will have 85% power to detect a twofold decrease of blood loss in the experimental arm, using a Wilcoxon (Mann-Whitney) rank-sum test with a 0.05 two-sided significance level. Twenty-one randomized patients per arm are required. Considering the risk of contraindications at surgery, up to eight patients may be enrolled in addition to the 42 planned, with an enrolment period of 24 months. Randomization will be stratified by surgeon. DISCUSSION: We previously demonstrated the safety and efficacy of intra-operative HIFU in patients operated on for LM. We also demonstrated the efficacy of HIFU-AR in a preclinical study. Participants in the HIFU-AR group of this randomized trial can expect to benefit from reduced blood loss and decreased ischemia of liver parenchyma. TRIAL REGISTRATION: Clinicaltrial.gov, NCT02728167 . Registered on 22 March 2016.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Neoplasias Colorretais/patologia , Hepatectomia/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Protocolos Clínicos , Desenho de Equipamento , França , Hepatectomia/efeitos adversos , Hepatectomia/instrumentação , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Humanos , Tempo de Internação , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Projetos de Pesquisa , Fatores de Tempo , Transdutores , Resultado do Tratamento
12.
Pancreas ; 46(2): 219-224, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27841792

RESUMO

OBJECTIVE: New focal destruction technologies such as high-intensity focused ultrasound (HIFU) may improve the prognosis of pancreatic ductal adenocarcinoma. Our objectives were to demonstrate the safety and efficacy of intraoperative pancreatic HIFU ablation in a porcine model. METHODS: In a porcine model (N = 12), a single HIFU ablation was performed in either the body or tail of the pancreas, distant to superior mesenteric vessels. All animals were sacrificed on the eighth day. The primary objective was to obtain an HIFU ablation measuring at least 1 cm without premature death. RESULTS: In total, 12 HIFU ablations were carried out. These ablations were performed within 160 seconds and on average measured 20 (15-27) × 16 (8-26) mm. The primary objective was fulfilled in all but 1 pig. There were no premature deaths or severe complications. High-intensity focused ultrasound treatment was associated with a transitory increase in amylase and lipase levels, and pseudocysts were observed in half of the pigs without being clinically apparent. All ablations were well delimited at both gross and histological examinations. CONCLUSIONS: Intraoperative thermal destruction of porcine pancreas with HIFU is feasible. Reproducibility and safety have to be confirmed when applied close to mesenteric vessels and in long-term preclinical studies.


Assuntos
Modelos Animais de Doenças , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Animais , Estudos de Viabilidade , Humanos , Período Intraoperatório , Pâncreas/patologia , Pâncreas/cirurgia , Neoplasias Pancreáticas/cirurgia , Prognóstico , Reprodutibilidade dos Testes , Suínos
13.
Sci Rep ; 5: 16354, 2015 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-26578234

RESUMO

Ultrasound (US) is a non-ionizing pressure wave that can produce mechanical and thermal effects. Bisphosphonates have demonstrated clinical utility in bone metastases treatment. Preclinical studies suggest that bisphosphonates have anticancer activity. However, bisphosphonates exhibit a high affinity for bone mineral, which reduces their bioavailability for tumor cells. Ultrasound has been shown to be effective for drug delivery but in interaction with gas bubbles or encapsulated drugs. We examined the effects of a clinically relevant dose of bisphosphonate zoledronate (ZOL) in combination with US. In a bone metastasis model, mice treated with ZOL+US had osteolytic lesions that were 58% smaller than those of ZOL-treated animals as well as a reduced skeletal tumor burden. In a model of primary tumors, ZOL+US treatment reduced by 42% the tumor volume, compared with ZOL-treated animals. Using a fluorescent bisphosphonate, we demonstrated that US forced the release of bisphosphonate from the bone surface, enabling a continuous impregnation of the bone marrow. Additionally, US forced the penetration of ZOL within tumors, as demonstrated by the intratumoral accumulation of unprenylated Rap1A, a surrogate marker of ZOL antitumor activity. Our findings made US a promising modality to trigger bisphosphonate anticancer activity in bone metastases and in primary tumors.


Assuntos
Conservadores da Densidade Óssea/farmacologia , Neoplasias Ósseas/secundário , Neoplasias da Mama/patologia , Difosfonatos/farmacologia , Hipertermia Induzida , Ondas Ultrassônicas , Animais , Conservadores da Densidade Óssea/farmacocinética , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/terapia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/terapia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Difosfonatos/farmacocinética , Modelos Animais de Doenças , Feminino , Hemiterpenos/biossíntese , Humanos , Hipertermia Induzida/métodos , Imidazóis/farmacologia , Compostos Organofosforados , Ensaios Antitumorais Modelo de Xenoenxerto , Ácido Zoledrônico , Proteínas rap1 de Ligação ao GTP/metabolismo
14.
PLoS One ; 10(9): e0137317, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26398366

RESUMO

Organ motion is a key component in the treatment of abdominal tumors by High Intensity Focused Ultrasound (HIFU), since it may influence the safety, efficacy and treatment time. Here we report the development in a porcine model of an Ultrasound (US) image-based dynamic fusion modeling method for predicting the effect of in vivo motion on intraoperative HIFU treatments performed in the liver in conjunction with surgery. A speckle tracking method was used on US images to quantify in vivo liver motions occurring intraoperatively during breathing and apnea. A fusion modeling of HIFU treatments was implemented by merging dynamic in vivo motion data in a numerical modeling of HIFU treatments. Two HIFU strategies were studied: a spherical focusing delivering 49 juxtapositions of 5-second HIFU exposures and a toroidal focusing using 1 single 40-second HIFU exposure. Liver motions during breathing were spatially homogenous and could be approximated to a rigid motion mainly encountered in the cranial-caudal direction (f = 0.20 Hz, magnitude > 13 mm). Elastic liver motions due to cardiovascular activity, although negligible, were detectable near millimeter-wide sus-hepatic veins (f = 0.96 Hz, magnitude < 1 mm). The fusion modeling quantified the deleterious effects of respiratory motions on the size and homogeneity of a standard "cigar-shaped" millimetric lesion usually predicted after a 5-second single spherical HIFU exposure in stationary tissues (Dice Similarity Coefficient: DSC < 45%). This method assessed the ability to enlarge HIFU ablations during respiration, either by juxtaposing "cigar-shaped" lesions with spherical HIFU exposures, or by generating one large single lesion with toroidal HIFU exposures (DSC > 75%). Fusion modeling predictions were preliminarily validated in vivo and showed the potential of using a long-duration toroidal HIFU exposure to accelerate the ablation process during breathing (from 0.5 to 6 cm3 · min(-1)). To improve HIFU treatment control, dynamic fusion modeling may be interesting for assessing numerically focusing strategies and motion compensation techniques in more realistic conditions.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado/cirurgia , Animais , Interpretação de Imagem Assistida por Computador , Período Intraoperatório , Fígado/fisiologia , Movimento , Cirurgia Assistida por Computador , Sus scrofa , Resultado do Tratamento
15.
Ultrasound Med Biol ; 41(10): 2740-54, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26213291

RESUMO

Ultrasound-mediated drug delivery is a field of research with promising results, although the exact mechanisms underlying intracellular delivery of therapeutic compounds remain to be elucidated. Many studies use drug carriers and cavitation to enhance drug uptake into tumor cells. However, cavitation could induce cell lysis and remain difficult to control and predict in vivo. In this study, low-intensity ultrasound was delivered using two transducers working at 2.9 and 1.3 MHz. The maximal peak negative pressure was 0.29 MPa to avoid cavitation. Low-intensity ultrasound induced clathrin-mediated endocytosis and forced the penetration of a bisphosphonate (zoledronic acid) into MCF-7 human breast cancer cells potentially as a result of mechanical stresses. When sonication parameters were adjusted to create mild hyperthermia in addition to the mechanical stress, further significant accumulation of ZOL was observed. These results provide better insight into the role of acoustic parameters in drug uptake.


Assuntos
Clatrina/metabolismo , Difosfonatos/administração & dosagem , Difosfonatos/farmacocinética , Eletroquimioterapia/métodos , Endocitose/efeitos da radiação , Imidazóis/administração & dosagem , Imidazóis/farmacocinética , Sonicação/métodos , Conservadores da Densidade Óssea/administração & dosagem , Conservadores da Densidade Óssea/farmacocinética , Sinergismo Farmacológico , Humanos , Células MCF-7 , Doses de Radiação , Ácido Zoledrônico
16.
PLoS One ; 10(2): e0118212, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25719540

RESUMO

BACKGROUND: Surgery is the only curative treatment in patients with colorectal liver metastases (CLM), but only 10-20% of patients are eligible. High Intensity Focused Ultrasound (HIFU) technology is of proven value in several indications, notably prostate cancer. Its intra-operative use in patients with CLM has not previously been studied. Preclinical work suggested the safety and feasibility of a new HIFU device capable of ablating volumes of up to 2cm x 2cm in a few seconds. METHODS: We conducted a prospective, single-centre phase I-IIa trial. HIFU was delivered immediately before scheduled hepatectomy. To demonstrate the safety and efficacy of rapidly ablating liver parenchyma, ablations were performed on healthy tissue within the areas scheduled for resection. RESULTS: In total, 30 ablations were carried out in 15 patients. These ablations were all generated within 40 seconds and on average measured 27.5mm x 21.0mm. The phase I study (n = 6) showed that use of the HIFU device was feasible and safe and did not damage neighbouring tissue. The phase IIa study (n = 9) showed both that the area of ablation could be precisely targeted on a previously implanted metallic mark (used to represent a major anatomical structure) and that ablations could be undertaken deliberately to avoid such a mark. Ablations were achieved with a precision of 1-2 mm. CONCLUSION: HIFU was feasible, safe and effective in ablating areas of liver scheduled for resection. The next stage is a phase IIb study which will attempt ablation of small metastases with a 5 mm margin, again prior to planned resection. TRIAL REGISTRATION: ClinicalTrials.govNCT01489787.


Assuntos
Neoplasias Colorretais/terapia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Neoplasias Hepáticas/terapia , Adulto , Idoso , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Feminino , Hepatectomia/efeitos adversos , Hepatectomia/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Período Intraoperatório , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade
17.
Ultrasound Med Biol ; 39(7): 1241-54, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23643055

RESUMO

Treatment with high-intensity focused ultrasound is well established but requires extended treatment time. A device composed of 256 elements arranged on a toroidal transducer was developed to increase the coagulated volume. When all the elements are working in phase for 40 s, a volume of 6-8 cm(3) can be ablated. However, the mechanical juxtaposition of single lesions is still necessary for treating one tumor with a diameter of 2 cm. The objective of this study was to combine this toroidal transducer geometry with electronic beam steering to ablate tumors with adequate normal tissue margins and without any mechanical displacement of the high-intensity focused ultrasound device. In vitro tests demonstrated that the coagulated volume obtained from 130 s of total exposure has an average diameter of 41.4 ± 4.0 mm and an average length of 53.3 ± 6.1 mm. This single lesion can be used to treat various size of metastasis, located at depths in the liver ranging 5-45 mm.


Assuntos
Coagulação Sanguínea/fisiologia , Coagulação Sanguínea/efeitos da radiação , Ondas de Choque de Alta Energia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Fígado/fisiologia , Fígado/efeitos da radiação , Transdutores , Animais , Bovinos , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro
18.
Ann Surg Oncol ; 19 Suppl 3: S447-54, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21796492

RESUMO

BACKGROUND: Bleeding is the main cause of postoperative complications of hepatic surgery. To minimize intraoperative bleeding during hepatectomy, resections are generally carried out under hepatic vascular control despite the risk of liver dysfunction in patients with chronic liver disease. This study evaluates the feasibility and safety of high-intensity focused ultrasound (HIFU)-assisted hepatic resection during an open procedure in an animal model. METHODS: Three groups of 12-14-week-old Landrace pigs (n = 7/group) were used to evaluate HIFU-assisted liver resection (group A) vs liver resection with or without portal triad clamping (groups B and C). In each pig, liver resection was performed on the right and left paramedian lobes. The following were evaluated and compared in the 3 groups: total blood loss, blood loss/cm(2) of resection area, clip density, procedure duration, morbidity, and mortality. RESULTS: Median blood loss was significantly lower in group A than in group B (P = .02), and group C (P = .007). Median blood loss/cm(2) of resection area was 4.77 mL/cm² in group A, 11.35 mL/cm² in group B, 12.22 mL/cm² in Group C. Precoagulation resulted in sealing blood vessels <5 mm; therefore, median clip density during liver transection was 0.78 clip/cm² in group A, 1.61 clip/cm(2) in group B, and 1.57 clip/cm(2) in group C. Median duration of the surgical procedure was 12 min in group A, 21 min in group B, and 19 min in group C. CONCLUSIONS: HIFU-assisted hepatic resection during an open procedure in an animal model is safe, reduces bleeding, and allows real-time ultrasound guidance.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Hemostasia Cirúrgica/métodos , Hepatectomia/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado/cirurgia , Animais , Volume Sanguíneo , Constrição , Hemostasia Cirúrgica/instrumentação , Hepatectomia/instrumentação , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Fígado/anatomia & histologia , Duração da Cirurgia , Estatísticas não Paramétricas , Suínos
19.
Ultrasonics ; 50(1): 44-51, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19683777

RESUMO

This study presents a contribution to the tracking of a moving target during high-intensity focused ultrasound (HIFU) treatment. Indeed, HIFU has proved to be highly efficient in inducing homogeneous and reproducible tumor destruction by thermal coagulation necrosis. However, accurate targeting of human abdominal tumors is difficult to maintain due to the motion induced by breathing. An algorithm is presented to track a region of interest of fixed size in a sequence of images. This algorithm was evaluated on synthetic data and on in vivo sequences of ultrasound liver images acquired using 12 MHz ultrasound imaging probe at a rate of 16 frames/s. The algorithm presented here was derived from the non-linear constant brightness assumption. Since the motion was smooth it was possible to reduce the space of admissible displacements; hence the number of unknown parameters was small compared with the size of the data. The optimal displacement was estimated by a Gauss-Newton method, and the matrix required at each step was assembled by reading the data only once. This algorithm was applied to simulated data, where the true displacement was known and a precise evaluation was possible. The relative error was about 2%. The algorithm was also applied to a video sequence of sonograms acquired during in vivo experiments. These trials were conducted on porcine liver since its size and physiology are similar to humans. Movements were induced by breathing and heart-beating. Two particular frequencies representing breathing (0.26 Hz) and heart beat (1.14 Hz) were identified in the estimated displacement and were correlated with the monitored breathing (0.27 Hz) and electrocardiograms (1.28 Hz). In addition, a region of interest (ROI) modeling the focal zone of a HIFU transducer was tracked along time. Therefore this study provides a mean of determining the location of the targeted region in vivo during HIFU treatments. This can be applied to correct the location of the focal zone accordingly. This method can preferentially be applied to the liver or to any other moving organ.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Fígado/fisiologia , Movimento/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/métodos , Algoritmos , Animais , Sistemas Computacionais , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
20.
Ann Surg ; 249(1): 129-36, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19106688

RESUMO

OBJECTIVE: To demonstrate in a porcine model that high-intensity focused ultrasound (HIFU) with toroid-shaped emitters may have a role in treating unresectable colorectal liver metastases. SUMMARY BACKGROUND DATA: Surgical resection is the only curative option for colorectal hepatic metastases. Only 20% of patients are suitable for surgery. Many ablative techniques have been assessed but several limitations have been documented: traumatic puncture of the parenchyma, limited size of lesions, and inability to monitor the treatment in real time. METHODS: A HIFU device with 256 toroid-shaped emitters and integrated ultrasound imaging probe was used. Single lesions, induced in 40 seconds, and juxtaposition of 6 single lesions were created under ultrasound guidance on 13 pigs. The lesions were studied on sonograms, macroscopically and microscopically up to 30 days after the treatment. RESULTS: Ninety percent of the HIFU lesions were immediately hypoechoic on ultrasound imaging. The average coagulated volume obtained from a 40 seconds total exposure in the liver was 7.0 +/- 2.5 cm (1.5-20.0), average diameter: 19.5 +/- 3.8 mm (10.0-29.0). Using the real-time visualization of the treated region, single lesions were easily juxtaposed to produce larger lesions up to 6 cm in diameter without any major complication. CONCLUSIONS: This toroid HIFU device allows short treatment times, noninvasiveness regarding the liver and real time ultrasound guidance. It seems to be simpler and more reliable to use than current ablative methods. Additionally, lesions through large vessels (up to 5 mm) being feasible, treatment of some juxta-vascular metastases should be possible.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Terapia por Ultrassom , Animais , Desenho de Equipamento , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/cirurgia , Suínos , Terapia por Ultrassom/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...