Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Eur Radiol ; 31(12): 9139-9149, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34047845

RESUMO

OBJECTIVE: It is unknown how patients prioritize gadolinium-based contrast media (GBCM) benefits (detection sensitivity) and risks (reactions, gadolinium retention, cost). The purpose of this study is to measure preferences for properties of GBCM in women at intermediate or high risk of breast cancer undergoing annual screening MRI. METHODS: An institutional reviewed board-approved prospective discrete choice conjoint survey was administered to patients at intermediate or high risk for breast cancer undergoing screening MRI at 4 institutions (July 2018-March 2020). Participants were given 15 tasks and asked to choose which of two hypothetical GBCM they would prefer. GBCMs varied by the following attributes: sensitivity for cancer detection (80-95%), intracranial gadolinium retention (1-100 molecules per 100 million administered), severe allergic-like reaction rate (1-19 per 100,000 administrations), mild allergic-like reaction rate (10-1000 per 100,000 administrations), out-of-pocket cost ($25-$100). Attribute levels were based on published values of existing GBCMs. Hierarchical Bayesian analysis was used to derive attribute "importance." Preference shares were determined by simulation. RESULTS: Response (87% [247/284]) and completion (96% [236/247]) rates were excellent. Sensitivity (importance = 44.3%, 95% confidence interval = 42.0-46.7%) was valued more than GBCM-related risks (mild allergic-like reaction risk (19.5%, 17.9-21.1%), severe allergic-like reaction risk (17.0%, 15.8-18.1%), intracranial gadolinium retention (11.6%, 10.5-12.7%), out-of-pocket expense (7.5%, 6.8-8.3%)). Lower income participants placed more importance on cost and less on sensitivity (p < 0.01). A simulator is provided that models GBCM preference shares by GBCM attributes and competition. CONCLUSIONS: Patients at intermediate or high risk for breast cancer undergoing MRI screening prioritize cancer detection over GBCM-related risks, and prioritize reaction risks over gadolinium retention. KEY POINTS: • Among women undergoing annual breast MRI screening, cancer detection sensitivity (attribute "importance," 44.3%) was valued more than GBCM-related risks (mild allergic reaction risk 19.5%, severe allergic reaction risk 17.0%, intracranial gadolinium retention 11.6%, out-of-pocket expense 7.5%). • Prospective four-center patient preference data have been incorporated into a GBCM choice simulator that allows users to input GBCM properties and calculate patient preference shares for competitor GBCMs. • Lower-income women placed more importance on out-of-pocket cost and less importance on cancer detection (p < 0.01) when prioritizing GBCM properties.


Assuntos
Meios de Contraste , Gadolínio , Teorema de Bayes , Meios de Contraste/efeitos adversos , Feminino , Humanos , Imageamento por Ressonância Magnética , Preferência do Paciente , Estudos Prospectivos , Fatores Socioeconômicos
2.
Clin Imaging ; 58: 84-89, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31279989

RESUMO

BACKGROUND: Dynamic contrast enhanced (DCE) breast MRI is highly sensitive for breast cancer and requires gadolinium-based contrast agents (GBCA)s, which have potential safety concerns. PURPOSE: Test whether breast cancers imaged by 3T DCE breast MRI with 0.05 mmol/kg of gadobutrol are detectable. METHODS: Analysis of 3T DCE breast MRIs with half dose of gadobutrol from patients included in an IRB-approved and HIPPA-compliant prospective study of breast PET/MRI. Between 11/7/2014 and 3/2/2018, 41 consecutive women with biopsy-proven breast cancer that was at least 2 cm, multi-focal or multi-centric, had axillary metastasis, or had skin involvement who gave informed consent were included. Two breast radiologists independently recorded lesion conspicuity on a 4-point scale (0 = not seen, 1 = questionably seen, 2 = adequately seen, 3 = certainly seen), and measured the lesion. Size was compared between radiologists and with size on available mammogram, ultrasound, MRI, and surgical pathology. Inter-reader agreement was assessed by kappa coefficient for conspicuity. Lesion size comparisons were assessed using the Spearman rank correlation. RESULTS: In 40 patients (ages 28.4-80.5, 51.9 years), there were 49 cancers. 10.1% of lesions were 1 cm or less and 26.5% of lesions were 2 cm or less. Each reader detected 49/49 cancers. Conspicuity scores ranged from 2 to 3, mean 2.9/3 for both readers (p = 0.47). Size on half-dose 3T DCE-MRI correlated with size on surgical pathology (r = 0.6, p = 0.03) while size on mammogram and ultrasound did not (r = 0.25, p = 0.46; r = 0.25, p = 0.42). CONCLUSION: All breast cancers in this cohort, as small as 0.4 cm, were seen on 3T DCE breast MRI with 0.05 mmol/kg dose of gadobutrol.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Eur J Radiol ; 110: 163-168, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30599855

RESUMO

PURPOSE: To investigate how breast parenchymal uptake (BPU) of 18F-FDG on positron emission tomography/ magnetic resonance imaging (PET/MRI) in patients with breast cancer is related to background parenchymal enhancement (BPE), amount of fibroglandular tissue (FGT), and age, as well as whether BPU varies as a function of distance from the primary breast cancer. MATERIALS AND METHODS: In this institutional review board (IRB)-approved retrospective study, 40 patients (all female, ages 32-80 years, mean 52 years) gave informed consent prior to undergoing contrast enhanced breast PET/MRI from 3/2015 to 2/2018. Of the 40 patients, 6 were excluded for multicentric or bilateral cancers, 1 for current lactation and 6 because the raw data from their scans were corrupted. The remaining 27 patients (all female, ages 33 to 80 years, mean age 53 years) comprised the study population. Prone PET and contrast-enhanced MR data were acquired simultaneously on a 3-T integrated PET/ MR system. BPU was measured as SUVmax of a 1.5 cm3 volume of interest 1) in the same quadrant of the ipsilateral breast, 5 mm from the index lesion; 2) in the opposite quadrant of the ipsilateral breast; and 3) in contralateral breast, quadrant matched to the opposite quadrant of the ipsilateral breast. The maximum standardized uptake value (SUVmax) of the index cancer was measured using a VOI that included the entire volume of the index lesion. Bleed from the primary tumor was corrected for (PET edge, MIM). FGT and BPE was assessed by 2 readers on a 4-point scale in accordance with BI-RADS lexicon. The Wilcoxon signed rank test and the Spearman rank correlation test were performed. RESULTS: BPU was significantly greater in the same quadrant as the breast cancer as compared with the opposite quadrant of the same breast (p < 0.001 for both readers) and was significantly greater in the opposite quadrant of the same breast compared to the matched quadrant of the contralateral breast (p = 0.002 for reader 1 and <0.001 for reader 2). While the FGT SUVmax in the same quadrant as the cancer correlated significantly with SUVmax of the index lesion, the FGT SUVmax in the opposite quadrant of the same breast and in the matched quadrant of the contralateral breast did not. The FGT SUVmax in the contralateral breast positively correlated with the degree of BPE and negatively correlated with age, but did not show a significant correlation with the amount of FGT for either reader. CONCLUSION: There appears to be an inverse correlation between metabolic activity of normal breast parenchyma and distance from the index cancer. BPU significantly correlates with BPE.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18/farmacocinética , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
J Magn Reson Imaging ; 49(2): 328-342, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30291656

RESUMO

Positron emission tomography / magnetic resonance imaging (PET/MRI) is an emerging imaging technology that allows for the acquisition of multiple MRI parameters simultaneously with PET data. In this review, we address the technical requirements of PET/MRI including protocols and tracers, the potential of integrated localized breast PET/MRI exams, and possible applications of whole-body PET/MRI in breast cancer patients. Currently, PET/MRI can be performed on sequential and integrated PET/MRI scanners but, as not all practices can access these dedicated machines, several studies look at PET and MRI exams that are performed separately on separate scanners within a short time frame. This practice likely provides similar clinical data, although exact colocalization for iso-voxel analysis, currently performed only in research, is not possible. In PET/MRI, the MRI sequences are flexible and can be customized according to the aim of the exam. The most commonly used radiotracer is 18 F-FDG; however, tracers that image hypoxia and drug targets such as estrogen receptors and HER2 are in development and may increase the utility of PET/MRI. For dedicated breast PET/MRI, a potential advantage over standard breast MRI alone may be the complementary sensitivities of MRI for extent of disease within the breast and PET for axillary and internal mammary nodal metastases. Moreover, layers of multiparametric MRI and PET metrics derived from the index lesion are being investigated as predictors of response to neoadjuvant therapy. These data may eventually be able to be quantified and mined in a way that furthers radiomics and also precision medicine. Finally, in whole-body imaging of breast cancer patients, single-institution studies have found that PET/MRI detects more metastases than PET at about half the radiation dose, although a survival benefit has not been shown. For now, whole-body PET/MRI in breast cancer patients may be most relevant for young patients who may undergo serial surveillance exams. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:328-342.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Adulto , Algoritmos , Axila/patologia , Biomarcadores Tumorais/análise , Feminino , Fluordesoxiglucose F18 , Humanos , Hipóxia , Antígeno Ki-67/análise , Linfonodos/patologia , Metástase Linfática , Pessoa de Meia-Idade , Terapia Neoadjuvante , Metástase Neoplásica , Receptor ErbB-2/análise
5.
Radiographics ; 38(4): 983-996, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29856684

RESUMO

Breast density, fibroglandular tissue, and background parenchymal enhancement (BPE) are recognized independent biomarkers for breast cancer risk. For this reason, reproducibility and consistency in objective assessment of these parameters at mammography (breast density) and at magnetic resonance imaging (fibroglandular tissue and BPE) are clinically relevant. However, breast density, fibroglandular tissue, and BPE are manifestations of dynamic physiologic processes and may change in response to both endogenous and exogenous hormonal stimulation. It is therefore important for the radiologist to recognize settings in which hormonal stimulation may alter the appearance of these biomarkers at imaging and to appreciate how such changes may affect risk assessment, cancer detection, and even prognosis. The purpose of this review article is therefore to review key features and means of evaluating breast density, fibroglandular tissue, and BPE at imaging; to detail how endogenous and exogenous hormonal stimuli may affect breast density, fibroglandular tissue, and BPE, potentially affecting radiologic interpretation; and, finally, to provide an update regarding current hormone treatment guidelines and indications that may result in imaging changes through hormone modulation. ©RSNA, 2018.


Assuntos
Densidade da Mama/efeitos dos fármacos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mama/efeitos dos fármacos , Terapia de Reposição Hormonal , Hormônios/farmacologia , Hormônios/fisiologia , Mama/diagnóstico por imagem , Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia
6.
Radiology ; 287(3): 732-747, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29782246

RESUMO

Precision medicine is medicine optimized to the genotypic and phenotypic characteristics of an individual and, when present, his or her disease. It has a host of targets, including genes and their transcripts, proteins, and metabolites. Studying precision medicine involves a systems biology approach that integrates mathematical modeling and biology genomics, transcriptomics, proteomics, and metabolomics. Moreover, precision medicine must consider not only the relatively static genetic codes of individuals, but also the dynamic and heterogeneous genetic codes of cancers. Thus, precision medicine relies not only on discovering identifiable targets for treatment and surveillance modification, but also on reliable, noninvasive methods of identifying changes in these targets over time. Imaging via radiomics and radiogenomics is poised for a central role. Radiomics, which extracts large volumes of quantitative data from digital images and amalgamates these together with clinical and patient data into searchable shared databases, potentiates radiogenomics, which is the combination of genetic and radiomic data. Radiogenomics may provide voxel-by-voxel genetic information for a complete, heterogeneous tumor or, in the setting of metastatic disease, set of tumors and thereby guide tailored therapy. Radiogenomics may also quantify lesion characteristics, to better differentiate between benign and malignant entities, and patient characteristics, to better stratify patients according to risk for disease, thereby allowing for more precise imaging and screening. This report provides an overview of precision medicine and discusses radiogenomics specifically in breast cancer. © RSNA, 2018.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Genômica/métodos , Interpretação de Imagem Assistida por Computador/métodos , Medicina de Precisão/métodos , Radiologia/métodos , Biomarcadores Tumorais/genética , Neoplasias da Mama/terapia , Feminino , Predisposição Genética para Doença/genética , Humanos , Mamografia
7.
Acad Radiol ; 25(9): 1101-1110, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29478921

RESUMO

RATIONALE AND OBJECTIVE: The objective of this study was to evaluate breast lesion outcomes in patients after canceled MRI-guided breast biopsy due to lesion nonvisualization. MATERIALS AND METHODS: Electronic medical records (January 2007-December 2014) were searched for patients with canceled magnetic resonance imaging (MRI)-guided breast biopsies due to lesion nonvisualization. A total of 1403 MRI-detected lesions were scheduled for MRI-guided biopsy and 89 were canceled because of nonvisualization. Imaging studies and medical records were reviewed for patient demographics, lesion characteristics, and subsequent malignancy. Patients without adequate MRI follow-up imaging were excluded. Statistical analysis was employed to determine if patient demographics or lesion characteristics were predictive of lesion resolution or lesion biopsy after subsequent follow-up. RESULTS: Eighty-nine (6.3% [89/1403]; 95% confidence interval, 5.2%-7.7%) biopsies in 89 women were canceled because of nonvisualization. Follow-up MRIs greater than 5.5 months were available for 60.7% (54/89) of women. In 74.1% (40/54) of these patients, the lesions completely resolved on follow-up. In 25.9% (14/54) of the patients, the lesion persisted on follow-up; 42.9% (6/14) of these patients underwent biopsy. One case (1.9% [1/54]) yielded ductal carcinoma in situ with microinvasion at the 6-month follow-up. No patient demographics or lesion features were associated with lesion resolution or lesion biopsy. CONCLUSIONS: The majority of canceled MRI-guided biopsy lesions resolved on later follow-up; however, because of the small possibility of a missed malignancy, follow-up MRI imaging at 6 months is recommended.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Mama/patologia , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Retrospectivos , Adulto Jovem
8.
J Magn Reson Imaging ; 47(6): 1692-1700, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29178258

RESUMO

BACKGROUND: Screening breast MRI has been shown to preferentially detect high-grade ductal carcinoma in situ (DCIS) and invasive carcinoma, likely due to increased angiogenesis resulting in early initial uptake of contrast. As interest grows in abbreviated screening breast MRI (AB-MRI), markers of early contrast washin that can predict tumor grade and potential aggressiveness are of clinical interest. PURPOSE: To evaluate the feasibility of using the initial enhancement ratio (IER) as a surrogate marker for tumor grade, hormone receptor status, and prognostic markers, as an initial step to being incorporated into AB-MRI. STUDY TYPE: Retrospective. SUBJECTS: In all, 162 women (mean 55.0 years, range 32.8-87.7 years) with 187 malignancies imaged January 2012-November 2015. FIELD STRENGTH/SEQUENCE: Images were acquired at 3.0T with a T1 -weighted gradient echo fat-suppressed-volume interpolated breath-hold sequence. ASSESSMENT: Subjects underwent dynamic contrast-enhanced breast MRI with a 7-channel breast coil. IER (% signal increase over baseline at the first postcontrast acquisition) was assessed and correlated with background parenchymal enhancement, washout curves, stage, and final pathology. STATISTICAL TESTS: Chi-square test, Spearman rank correlation, Mann-Whitney U-tests, Bland-Altman analysis, and receiver operating characteristic curve analysis. RESULTS: IER was higher for invasive cancer than for DCIS (R1/R2, P < 0.001). IER increased with tumor grade (R1: r = 0.56, P < 0.001, R2: r = 0.50, P < 0.001), as ki-67 increased (R1: r = 0.35, P < 0.001; R2 r = 0.35, P < 0.001), and for node-positive disease (R1/R2, P = 0.001). IER was higher for human epidermal growth factor receptor two-positive and triple negative cancers than for estrogen receptor-positive / progesterone receptor-positive tumors (R1 P < 0.001-0.002; R2 P = 0.0.001-0.011). IER had higher sensitivity (80.6% vs. 75.5%) and specificity (55.8% vs. 48.1%) than washout curves for positive nodes, higher specificity (48.1% vs. 36.5%) and positive predictive value (70.2% vs. 66.7%) for high ki-67, and excellent interobserver agreement (intraclass correlation coefficient = 0.82). DATA CONCLUSION: IER, a measurement of early contrast washin, is associated with higher-grade malignancies and tumor aggressiveness and might be potentially incorporated into an AB-MRI protocol. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1692-1700.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Invasividade Neoplásica , Neovascularização Patológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
J Magn Reson Imaging ; 47(6): 1685-1691, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29140576

RESUMO

BACKGROUND: Potential clinical implications of the level of background parenchymal enhancement (BPE) on breast MRI are increasing. Currently, BPE is typically evaluated subjectively. Tests of concordance between subjective BPE assessment and computer-assisted quantified BPE have not been reported. PURPOSE OR HYPOTHESIS: To compare subjective radiologist assessment of BPE with objective quantified parenchymal enhancement (QPE). STUDY TYPE: Cross-sectional observational study. POPULATION: Between 7/24/2015 and 11/27/2015, 104 sequential patients (ages 23 - 81 years, mean 49 years) without breast cancer underwent breast MRI and were included in this study. FIELD STRENGTH/SEQUENCE: 3T; fat suppressed axial T2, axial T1, and axial fat suppressed T1 before and after intravenous contrast. ASSESSMENT: Four breast imagers graded BPE at 90 and 180 s after contrast injection on a 4-point scale (a-d). Fibroglandular tissue masks were generated using a phantom-validated segmentation algorithm, and were co-registered to pre- and postcontrast fat suppressed images to define the region of interest. QPE was calculated. STATISTICAL TESTS: Receiver operating characteristic (ROC) analyses and kappa coefficients (k) were used to compare subjective BPE with QPE. RESULTS: ROC analyses indicated that subjective BPE at 90 s was best predicted by quantified QPE ≤20.2 = a, 20.3-25.2 = b, 25.3-50.0 = c, >50.0 = d, and at 180 s by quantified QPE ≤ 32.2 = a, 32.3-38.3 = b, 38.4-74.5 = c, >74.5 = d. Agreement between subjective BPE and QPE was slight to fair at 90 s (k = 0.20-0.36) and 180 s (k = 0.19-0.28). At higher levels of QPE, agreement between subjective BPE and QPE significantly decreased for all four radiologists at 90 s (P ≤ 0.004) and for three of four radiologists at 180 s (P ≤ 0.004). DATA CONCLUSION: Radiologists were less consistent with QPE as QPE increased. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1685-1691.


Assuntos
Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Estudos Transversais , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
10.
Clin Imaging ; 42: 119-125, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27951458

RESUMO

PURPOSE: To evaluate clinical applicability of fibroglandular tissue (FGT) segmentation on routine T1 weighted breast MRI and compare FGT quantification with radiologist assessment. METHODS: FGT was segmented on 232 breasts and quantified, and was assessed qualitatively by four breast imagers. RESULTS: FGT segmentation was successful in all 232 breasts. Agreement between radiologists and quantified FGT was moderate to substantial (kappa=0.52-0.67); lower quantified FGT was associated with disagreement between radiologists and quantified FGT (P≤0.002). CONCLUSIONS: FGT segmentation was successful using routine T1 weighted breast MRI. Radiologists were less consistent with quantified results in breasts with lower quantified FGT.


Assuntos
Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos
11.
Magn Reson Med ; 78(3): 1147-1156, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27779790

RESUMO

PURPOSE: Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusion, and glucose avidity in breast cancer with simultaneous PET/MR imaging and compares correlations with clinical prognostics. METHODS: In this Health Insurance Portability and Accountability Act-compliant prospective study, with written informed consent and approval of the institutional review board and using simultaneously acquired FDG-PET and DWI, tissue diffusion (Dt ), and perfusion fraction (fp ) from intravoxel incoherent motion (IVIM) analysis were registered to FDG-PET within 14 locally advanced breast cancers. Lesions were analyzed using 2D histograms and correlation coefficients between Dt , fp , and standardized uptake value (SUV). Correlations were compared with prognostics from biopsy, metastatic burden from whole-body PET, and treatment history. RESULTS: SUV||Dt correlation coefficient significantly distinguished treated (0.11 ± 0.24) from nontreated (-0.33 ± 0.26) patients (P = 0.005). SUV||fp correlations were on average negative for the whole cohort (-0.17 ± 0.13). CONCLUSION: Simultaneously acquired and registered FDG-PET/DWI allowed quantifiable descriptions of breast cancer microenvironments that may provide a framework for monitoring and predicting response to treatment. Magn Reson Med 78:1147-1156, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Movimento/fisiologia
12.
J Magn Reson Imaging ; 45(6): 1746-1752, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27859874

RESUMO

PURPOSE: To compare a novel multicoil compressed sensing technique with flexible temporal resolution, golden-angle radial sparse parallel (GRASP), to conventional fat-suppressed spoiled three-dimensional (3D) gradient-echo (volumetric interpolated breath-hold examination, VIBE) MRI in evaluating the conspicuity of benign and malignant breast lesions. MATERIALS AND METHODS: Between March and August 2015, 121 women (24-84 years; mean, 49.7 years) with 180 biopsy-proven benign and malignant lesions were imaged consecutively at 3.0 Tesla in a dynamic contrast-enhanced (DCE) MRI exam using sagittal T1-weighted fat-suppressed 3D VIBE in this Health Insurance Portability and Accountability Act-compliant, retrospective study. Subjects underwent MRI-guided breast biopsy (mean, 13 days [1-95 days]) using GRASP DCE-MRI, a fat-suppressed radial "stack-of-stars" 3D FLASH sequence with golden-angle ordering. Three readers independently evaluated breast lesions on both sequences. Statistical analysis included mixed models with generalized estimating equations, kappa-weighted coefficients and Fisher's exact test. RESULTS: All lesions demonstrated good conspicuity on VIBE and GRASP sequences (4.28 ± 0.81 versus 3.65 ± 1.22), with no significant difference in lesion detection (P = 0.248). VIBE had slightly higher lesion conspicuity than GRASP for all lesions, with VIBE 12.6% (0.63/5.0) more conspicuous (P < 0.001). Masses and nonmass enhancement (NME) were more conspicuous on VIBE (P < 0.001), with a larger difference for NME (14.2% versus 9.4% more conspicuous). Malignant lesions were more conspicuous than benign lesions (P < 0.001) on both sequences. CONCLUSION: GRASP DCE-MRI, a multicoil compressed sensing technique with high spatial resolution and flexible temporal resolution, has near-comparable performance to conventional VIBE imaging for breast lesion evaluation. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. MAGN. RESON. IMAGING 2017;45:1746-1752.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Compressão de Dados/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Desenho de Equipamento , Feminino , Humanos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação
13.
AJR Am J Roentgenol ; 207(3): 676-84, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27275652

RESUMO

OBJECTIVE: MRI-guided needle localization allows access to MRI-detected mammographically occult breast lesions that are not amenable to MRI-guided biopsy. The purpose of this study was to examine the safety and outcomes of MRI-guided needle localization. MATERIALS AND METHODS: Ninety-nine consecutive breast lesions that underwent preoperative MRI-guided needle localization were identified. Clinical indications for breast MRI, reasons for performing MRI-guided needle localization, and surgical pathology results were recorded. Lesion characteristics, procedure time, and complications were assessed. RESULTS: Of 99 lesions, 60 (60.6%) were in a location inaccessible for MRI biopsy, necessitating MRI-guided needle localization. Histologic evaluation revealed 38 (38.4%) carcinomas, 31 (31.3%) high-risk lesions, and 30 (30.3%) benign lesions. Carcinoma was more likely to be found in women with known cancer (31/61 [50.8%]; p = 0.003) than in women undergoing imaging for high-risk screening (2/18 [11.1%]) or problem solving (6/20 [30%]). Masses (p = 0.013) and foci (p < 0.001) were more likely to be malignant than were lesions with nonmass enhancement. Foci were significantly more often malignant compared with all other lesion types (9/10 [90%]; p < 0.001). The mean (± SD) procedure time was 32.9 ± 9.39 minutes. All lesions were occult on specimen radiographs. There were no procedure-related complications. CONCLUSION: The positive predictive value of MRI-guided needle localization (38.4%) is comparable to that of mammography- and tomosynthesis-guided localizations and is highest in women with a known diagnosis of cancer. It is highly accurate in targeting small enhancing lesions, thereby improving surgical management. MRI-guided needle localization is a safe, accurate, and time-efficient procedure.


Assuntos
Biópsia por Agulha/métodos , Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
14.
Clin Nucl Med ; 41(8): e355-61, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27187730

RESUMO

PURPOSE: This study aims to investigate the feasibility of using simultaneous breast MRI and PET to assess the synergy of MR pharmacokinetic and fluorine-18 fluorodeoxyglucose (F-FDG) uptake data to characterize tumor aggressiveness in terms of metastatic burden and Ki67 status. METHODS: Twelve consecutive patients underwent breast and whole-body PET/MRI. During the MR scan, PET events were simultaneously accumulated. MR contrast kinetic model parametric maps were computed using the extended Tofts model, including the volume transfer constant between blood plasma and the interstitial space (K), the transfer constant from the interstitial space to the blood plasma (kep), and the plasmatic volume fraction (Vp). RESULTS: Patients with systemic metastases had a significantly lower kep compared to those with local disease (0.45 vs. 0.99 min, P = 0.011). Metastatic burden correlated positively with K and standardized uptake value (SUV), and negatively with kep. Ki67 positive tumors had a significantly greater K compared to Ki67 negative tumors (0.29 vs. 0.45 min, P = 0.03). A negative correlation was found between metabolic tumor volume and transfer constant (K or Kep). CONCLUSION: These preliminary results suggest that MR pharmacokinetic parameters and FDG-PET may aid in the assessment of tumor aggressiveness and metastatic potential. Future studies are warranted with a larger cohort to further assess the role of pharmacokinetic modeling in simultaneous PET/MRI imaging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Metástase Neoplásica , Compostos Radiofarmacêuticos
15.
Radiology ; 281(1): 193-202, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27023002

RESUMO

Purpose To compare fluorine 18 ((18)F) fluorodeoxyglucose (FDG) combined positron emission tomography (PET) and magnetic resonance (MR) imaging with (18)F FDG combined PET and computed tomography (CT) in terms of organ-specific metastatic lesion detection and radiation dose in patients with breast cancer. Materials and Methods From July 2012 to October 2013, this institutional review board-approved HIPAA-compliant prospective study included 51 patients with breast cancer (50 women; mean age, 56 years; range, 32-76 years; one man; aged 70 years) who completed PET/MR imaging with diffusion-weighted and contrast material-enhanced sequences after unenhanced PET/CT. Written informed consent for study participation was obtained. Two independent readers for each modality recorded site and number of lesions. Imaging and clinical follow-up, with consensus in two cases, served as the reference standard. Results There were 242 distant metastatic lesions in 30 patients, 18 breast cancers in 17 patients, and 19 positive axillary nodes in eight patients. On a per-patient basis, PET/MR imaging with diffusion-weighted and contrast-enhanced sequences depicted distant (30 of 30 [100%] for readers 1 and 2) and axillary (eight of eight [100%] for reader 1, seven of eight [88%] for reader 2) metastatic disease at rates similar to those of unenhanced PET/CT (distant metastatic disease: 28 of 29 [96%] for readers 3 and 4, P = .50; axillary metastatic disease: seven of eight [88%] for readers 3 and 4, P > .99) and outperformed PET/CT in the detection of breast cancer (17 of 17 [100%] for readers 1 and 2 vs 11 of 17 [65%] for reader 3 and 10 of 17 [59%] for reader 4; P < .001). PET/MR imaging showed increased sensitivity for liver (40 of 40 [100%] for reader 1 and 32 of 40 [80%] for reader 2 vs 30 of 40 [75%] for reader 3 and 28 of 40 [70%] for reader 4; P < .001) and bone (105 of 107 [98%] for reader 1 and 102 of 107 [95%] for reader 2 vs 106 of 107 [99%] for reader 3 and 93 of 107 [87%] for reader 4; P = .012) metastases and revealed brain metastases in five of 51 (10%) patients. PET/CT trended toward increased sensitivity for lung metastases (20 of 23 [87%] for reader 1 and 17 of 23 [74%] for reader 2 vs 23 of 23 [100%] for reader 3 and 22 of 23 [96%] for reader 4; P = .065). Dose reduction averaged 50% (P < .001). Conclusion In patients with breast cancer, PET/MR imaging may yield better sensitivity for liver and possibly bone metastases but not for pulmonary metastases, as compared with that attained with PET/CT, at about half the radiation dose. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagem Corporal Total , Adulto , Idoso , Neoplasias da Mama Masculina/diagnóstico por imagem , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Compostos Radiofarmacêuticos
16.
Eur J Radiol ; 85(4): 815-23, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26971429

RESUMO

OBJECTIVE: This study evaluates use of an abbreviated magnetic resonance imaging protocol with T2-weighted imaging in detecting biopsy-proven unifocal breast cancer. MATERIALS AND METHODS: This is an institutional review board approved retrospective study of patients with biopsy-proven unifocal breast cancer (88% invasive; 12% in situ) undergoing magnetic resonance imaging. In three separate sessions, three breast imagers evaluated (1) T1-weighted non-contrast, post-contrast and post-contrast subtracted images, (2) T1-weighted images with clinical history and prior imaging, and (3) T1-weighted images and T2-weighted images with clinical history and prior imaging. Protocols were compared for cancer detection, reading time and lesion conspicuity. An independent breast radiologist retrospectively analyzed initial enhancement ratio of cancers and retrospectively reviewed lesion morphology and final pathology. RESULTS: All 107 cancers were identified at first protocol by at least one reader; five cancers were missed by either one or two readers. One cancer was missed by one reader at protocols two and three. Mean percentage detection for protocol one was 97.8%; protocol two, 99.4%, protocol three, 99.4%. T2-weighted images did not alter cancer detection but increased lesion conspicuity for 2/3 readers. 3/5 missed lesions were low grade cancers. Initial enhancement ratio was positively associated with increasing tumor grade (p=0.031) and pathology (p=0.002). Reader interpretation time decreased and lesion conspicuity increased as initial enhancement ratio increased. CONCLUSION: Abbreviated magnetic resonance imaging has high rate of detection for known breast cancer and short interpretation time. T2 weighted imaging increased lesion conspicuity without altering detection rate. Initial enhancement ratio correlated with invasive disease and tumor grade.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/patologia , Meios de Contraste , Erros de Diagnóstico , Feminino , Seguimentos , Gadolínio DTPA , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Estudos Retrospectivos , Técnica de Subtração , Fatores de Tempo
17.
Breast J ; 22(3): 264-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26843433

RESUMO

Quantitative standardized uptake values (SUVs) from fluorine-18 (18F) fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) are commonly used to evaluate the extent of disease and response to treatment in breast cancer patients. Recently, PET/magnetic resonance imaging (MRI) has been shown to qualitatively detect metastases from various primary cancers with similar sensitivity to PET/CT. However, quantitative validation of PET/MRI requires assessing the reliability of SUVs from MR attenuation correction (MRAC) relative to CT attenuation correction (CTAC). The purpose of this retrospective study was to assess the utility of PET/MRI-derived SUVs in breast cancer patients by testing the hypothesis that SUVs derived from MRAC correlate well with those from CTAC. Between August 2012 and May 2013, 35 breast cancer patients (age 37-78 years, 1 man) underwent clinical 18F-FDG PET/CT followed by PET/MRI. One hundred seventy metastases were seen in 21 of 35 patients; metastases to bone in 16 patients, to liver in seven patients, and to nonaxillary lymph nodes in eight patients were sufficient for statistical analysis on an organ-specific per patient basis. SUVs in the most FDG-avid metastasis per organ per patient from PET/CT and PET/MRI were measured and compared using Pearson's correlations. Correlations between CTAC- and MRAC-derived SUVmax and SUVmean in 31 metastases to bone, liver, and nonaxillary lymph nodes were strong overall (ρ = 0.80, 0.81). SUVmax and SUVmean correlations were also strong on an organ-specific basis in 16 bone metastases (ρ = 0.76, 0.74), seven liver metastases (ρ = 0.85, 0.83), and eight nonaxillary lymph node metastases (ρ = 0.95, 0.91). These strong organ-specific correlations between SUVs from PET/CT and PET/MRI in breast cancer metastases support the use of SUVs from PET/MRI for quantitation of 18F-FDG activity.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/normas , Adulto , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Neoplasias da Mama Masculina/diagnóstico por imagem , Neoplasias da Mama Masculina/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos
18.
Acad Radiol ; 23(3): 358-67, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26774741

RESUMO

RATIONALE AND OBJECTIVES: To investigate whether quantitative kinetic analysis of lesions and background parenchyma in breast magnetic resonance imaging can elucidate differences between BRCA carriers and sporadic controls with high risk for breast cancer. MATERIALS AND METHODS: Fifty-nine BRCA and 59 control cases (49 benign, 10 malignant) were examined in this study. Principal component analysis was applied for quantitative analysis of dynamic signal in background parenchyma (B) and lesion (L) in terms of initial enhancement ratio (IER) and delayed enhancement ratio (DER). RESULTS: Control B-IER, B-DER, L-IER, and L-DER were higher than BRCA cases in all women and in women with benign lesions; statistically significant differences in B-IER and B-DER (all women: P = 0.02 and P = 0.02, respectively; benign only: P = 0.005 and P = 0.005, respectively). In the control cohort, B-IER and B-DER were higher in the premenopausal women than in the postmenopausal women (P = 0.013 and 0.003, respectively), but not in the BRCA cohort; this led to significant differences in B-IER and B-DER between the control and the BRCA groups in the premenopausal women (P = 0.01 and 0.01, respectively) but not in the postmenopausal women. CONCLUSION: Results suggest possible differences in the vascular properties of background parenchyma between BRCA carriers and noncarriers and its association with menopausal status.


Assuntos
Proteína BRCA1/genética , Proteína BRCA2/genética , Neoplasias da Mama/patologia , Mama/patologia , Heterozigoto , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Mutação/genética , Adulto , Idoso , Biópsia/métodos , Neoplasias da Mama/genética , Estudos de Casos e Controles , Estudos de Coortes , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Cinética , Imagem por Ressonância Magnética Intervencionista/métodos , Pessoa de Meia-Idade , Pós-Menopausa , Pré-Menopausa , Estudos Retrospectivos
19.
Radiographics ; 34(3): 642-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24819786

RESUMO

Oncologic, reconstructive, and cosmetic breast surgery has evolved in the last 20 years. Familiarity with cutting-edge surgical techniques and their imaging characteristics is essential for radiologic interpretation and may help avert false-positive imaging findings. Novel surgical techniques include skin- and nipple-sparing mastectomies, autologous free flaps, autologous fat grafting, and nipple-areola-complex breast reconstruction. These techniques are illustrated and compared with conventional surgical techniques, including modified radical mastectomy and autologous pedicled flaps. The role of magnetic resonance (MR) imaging in surgical planning, evaluation for complications, and postsurgical cancer detection is described. Breast reconstruction and augmentation using silicone gel-filled implants is discussed in light of the Food and Drug Administration's recommendation for MR imaging screening for "silent" implant rupture 3 years after implantation and every 2 years thereafter. Recent developments in skin incision techniques for reduction mammoplasty are presented. The effects of postsurgical changes on the detection of breast cancer are discussed by type of surgery.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/cirurgia , Mamografia , Ultrassonografia Mamária/métodos , Tecido Adiposo/transplante , Implantes de Mama/efeitos adversos , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamoplastia/métodos , Mamografia/métodos , Mastectomia/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Período Pós-Operatório , Falha de Prótese , Sensibilidade e Especificidade , Retalhos Cirúrgicos
20.
Eur Radiol ; 24(6): 1176-85, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24623366

RESUMO

OBJECTIVE: To determine the utility of short-interval follow-up after benign concordant MRI-guided breast biopsy. MATERIALS AND METHODS: Institutional review board approved, retrospective review of consecutive biopsies performed over 3 years (2007-10) yielded 170 women with 188 lesions that were considered benign concordant. Indication for original study, biopsy results, follow-up recommendations, compliance and outcomes of subsequent MRI and mammography examinations were reviewed. RESULTS: The most common indication for breast MRI was high-risk screening 119/170 (70 %). Overall, 59 % of lesions (113/188) had follow-up MRI. Of those lesions (n = 113), 43 % (49/113) presented within 7 months, 26 % (29/113) presented within 8-13 months, 11.5 % (13/113) presented within 14-22 months, and 19 % (22/113) presented after 23 months. At initial follow-up, 37 % of lesions were stable and 61 % were decreased in size. Three lesions were recommended for excision based on follow-up imaging with one malignancy diagnosed 2 years following biopsy. One additional patient had MRI-detected bilateral cancers remote from the biopsy site 3 years after biopsy. CONCLUSION: Overall cancer yield of lesions with follow-up MRI was 0.9 % (1/113); no cancers were detected at 6 months. Our data suggests that 6-month follow-up may not be required and that annual screening MRI would be acceptable to maintain a reasonable cancer detection rate. KEY POINTS: Follow-up recommendations after benign concordant MRI-guided breast biopsy remain controversial. Cancer detection rate was 0.9 % overall with no cancers detected at 6 months. Short-interval follow-up after benign concordant MRI-guided breast biopsy may not be necessary.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Fibroadenoma/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Fibroadenoma/diagnóstico por imagem , Doença da Mama Fibrocística/diagnóstico por imagem , Doença da Mama Fibrocística/patologia , Seguimentos , Hemangioma Capilar/diagnóstico por imagem , Hemangioma Capilar/patologia , Humanos , Mamografia , Pessoa de Meia-Idade , Papiloma/diagnóstico por imagem , Papiloma/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...