Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Oleo Sci ; 72(7): 667-680, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37380483

RESUMO

The objective of our study is to evaluate quality and thermo oxidative stability of soybean, palm olein, and canola oils and their blends. The binary blends of SO:POO and CO:POO were formulated in a ratio of 75:25 and ternary blend were prepared by blending CO:POO:SO in a ratio of 35:30:35. To monitor the thermal stability, pure oils and their blends were subjected to heating at 180°C for 4 hours. Heating process led to a substantial increase in free fatty acid (FFA), peroxide value (PV), p-anisidine value (p-AV), and saponification value (SV), while iodine value (IV) and oxidative stability index (OSI) were decreased. The principal component analysis (PCA) was also performed. The data indicated that three significant principal components have eigenvalue ˃ 1, which collectively constitute 98.8% of the total variance. PC1 contributed mainly with a total value of 50.1%, followed by PC2 (36.2%) and PC3 (12.5%). Results of the present study revealed that the binary and ternary blends exhibited greater oxidative stability than the pure oils. But, the ternary blend CO:POO:SO in a ratio of (35:30:35) was found to be better on the basis of stability and health point of view than other blends. Overall, our study demonstrated the utility of chemometric approaches for evaluating the quality and stability of vegetable oils and their blends, which can be helpful in the selection and optimization of oil blends for food applications.


Assuntos
Brassica napus , Glycine max , Quimiometria , Óleos de Plantas , Estresse Oxidativo
2.
J AOAC Int ; 100(4): 1062-1069, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28251882

RESUMO

A new simple, selective, and economical preconcentration method was developed for the determination of Cd, Pb, and Ni in poultry antibiotics and supplements. The proposed preconcentration procedure is based on SPE using 8-hydroxyquinoline and Amberlite IRC-50 resin as complex and adsorbent, respectively. The determination was carried out by microsample injection system (MIS) flame atomic absorption spectroscopy (FAAS). Several analytical parameters were examined, including pH, type of resin, amount of resin, type of eluent, eluent volume, flow rate, sample volume, and interference of diverse ions. Under optimum experimental conditions, LODs and LOQs were 0.017 and 0.055, 0.016 and 0.53, and 0.074 and 0.248 µg/L for Cd, Pb, and Ni, respectively, with RSDs < 2.50%. The accuracy of SPE-MIS-FAAS was successfully tested by the standard addition method, with obtained recoveries >99%. The proposed method was successfully applied for the determination of Cd, Pb, and Ni in poultry supplement and antibiotic samples.


Assuntos
Ração Animal/análise , Cádmio/análise , Suplementos Nutricionais/análise , Chumbo/análise , Níquel/análise , Animais , Concentração de Íons de Hidrogênio , Aves Domésticas , Extração em Fase Sólida , Espectrofotometria Atômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...