Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
EJNMMI Phys ; 11(1): 61, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004681

RESUMO

BACKGROUND: Several research groups have explored the potential of scandium radionuclides for theragnostic applications due to their longer half-lives and equal or similar coordination chemistry between their diagnostic and therapeutic counterparts, as well as lutetium-177 and terbium-161, respectively. Unlike the gallium-68/lutetium-177 pair, which may show different in-vivo uptake patterns, the use of scandium radioisotopes promises consistent behaviour between diagnostic and therapeutic radiopeptides. An advantage of scandium's longer half-life over gallium-68 is the ability to study radiopeptide uptake over extended periods and its suitability for centralized production and distribution. However, concerns arise from scandium-44's decay characteristics and scandium-43's high production costs. This study aimed to evaluate the dosimetric implications of using scandium radioisotopes with somatostatin analogues against gallium-68 for PET imaging of neuroendocrine tumours. METHODS: Absorbed dose per injected activity (AD/IA) from the generated time-integrated activity curve (TIAC) were estimated using the radiopeptides [43/44/44mSc]Sc- and [68Ga]Ga-DOTATATE. The kidneys, liver, spleen, and red bone marrow (RBM) were selected for dose estimation studies. The EGSnrc and MCNP6.1 Monte Carlo (MC) codes were used with female (AF) and male (AM) ICRP phantoms. The results were compared to Olinda/EXM software, and the effective dose concentrations assessed, varying composition between the scandium radioisotopes. RESULTS: Our findings showed good agreement between the MC codes, with - 3 ± 8% mean difference. Kidneys, liver, and spleen showed differences between the MC codes (min and max) in a range of - 4% to 8%. This was observed for both phantoms for all radiopeptides used in the study. Compared to Olinda/EXM the largest observed difference was for the RBM, of 21% for the AF and 16% for the AM for scandium- and gallium-based radiopeptides. Despite the differences, our findings showed a higher absorbed dose on [43/44Sc]Sc-DOTATATE compared to its 68Ga-based counterpart. CONCLUSION: This study found that [43/44Sc]Sc-DOTATATE delivers a higher absorbed dose to organs at risk compared to [68Ga]Ga-DOTATATE, assuming equal distribution. This is due to the longer half-life of scandium radioisotopes compared to gallium-68. However, calculated doses are within acceptable ranges, making scandium radioisotopes a feasible replacement for gallium-68 in PET imaging, potentially offering enhanced diagnostic potential with later timepoint imaging.

2.
Br J Radiol ; 90(1080): 20170187, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28937271

RESUMO

OBJECTIVE: The aim of this work was to simulate a 6MV conventional breast 3D conformational radiation therapy (3D-CRT) with physical wedges (50 Gy/25#) in the left breast, calculate the mean absorbed dose in the body organs using robust models and computational tools and estimate the secondary cancer-incidence risk to the Brazilian population. METHODS: The VW female phantom was used in the simulations. Planning target volume (PTV) was defined in the left breast. The 6MV parallel-opposed fields breast-radiotherapy (RT) protocol was simulated with MCNPx code. The absorbed doses were evaluated in all the organs. The secondary cancer-incidence risk induced by radiotherapy was calculated for different age groups according to the BEIR VII methodology. RESULTS: RT quality indexes indicated that the protocol was properly simulated. Significant absorbed dose values in red bone marrow, RBM (0.8 Gy) and stomach (0.6 Gy) were observed. The contralateral breast presented the highest risk of incidence of a secondary cancer followed by leukaemia, lung and stomach. The risk of a secondary cancer-incidence by breast-RT, for the Brazilian population, ranged between 2.2-1.7% and 0.6-0.4%. CONCLUSION: RBM and stomach, usually not considered as OAR, presented high second cancer incidence risks of 0.5-0.3% and 0.4-0.1%, respectively. This study may be helpful for breast-RT risk/benefit assessment. Advances in knowledge: MCNPX-dosimetry was able to provide the scatter radiation and dose for all body organs in conventional breast-RT. It was found a relevant risk up to 2.2% of induced-cancer from breast-RT, considering the whole thorax organs and Brazilian cancer-incidence.


Assuntos
Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Neoplasias Unilaterais da Mama/radioterapia , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiometria , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Medição de Risco , Fatores de Risco
3.
Braz. J. Pharm. Sci. (Online) ; 53(1): e16092, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839463

RESUMO

ABSTRACT The aim of this study was to create and test a new mice 3D-voxel phantom named DM_BRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-of-art in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DM_BRA model was performed at 0.015, 0.1, 0.5, 1 and 4 MeV photons with heart-source. Specific Absorbed Fractions (SAF) data were compared with literature data. The organ masses of DM_BRA correlated well with existing models based on the same dataset; however, few small organ masses hold significant variations. The SAF data in most simulated cases were statistically equal to a significant level of 0.01 to the reference data.


Assuntos
Alfabetização Digital , Dosimetria/análise , Camundongos/classificação , Radiometria/métodos
4.
Appl Radiat Isot ; 117: 123-127, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26778764

RESUMO

The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine internal monitoring of occupationally exposed individuals. The determination of photon emitting radionuclides in the human body requires calibration of the detector in specific counting geometries. The calibration process uses physical phantoms containing certified activities of the radionuclides of interest. The objective of this work was to obtain calibration efficiency curves of the Whole Body Counter in operation at the LDI/CDTN using a BOMAB physical phantom and Monte Carlo simulations.


Assuntos
Método de Monte Carlo , Radioisótopos/análise , Radioisótopos/normas , Software , Contagem Corporal Total/instrumentação , Contagem Corporal Total/normas , Brasil , Calibragem/normas , Análise de Falha de Equipamento/normas , Humanos , Laboratórios , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA