1.
Cardiol J ; 27(5): 541-547, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30566212

RESUMO

BACKGROUND: Air pollution triggered diseases have become a leading health problem worldwide. The main adverse effects of air pollutants on human health are related to the cardiovascular system and particularly show an increasing prevalence of myocardial infarct and stroke. The aim of the study was to evaluate the influence of main air pollutants on non-ST-segment elevation myocardial infarction (NSTEMI) and ST-segment elevation myocardial infarction (STEMI) admissions to local interventional cardiology centers. METHODS: Between 2014 and 2015, a multicenter registry of 1957 patients with acute myocardial infarction (STEMI, NSTEMI) admitted to interventional cardiology departments in three Polish cities were under investigation. The air pollution (PM2.5, PM10, NO2, SO2, O3) and weather conditions (temperature, barometric pressure, humidity) data for each city were collected as daily averages. The case-crossover design and conditional logistic regression were used to explore the association between acute myocardial infarctions and short-term air pollution exposure. RESULTS: Occurrence of NSTEMI on the day of air pollution was triggered by PM2.5 (OR = 1.099, p = 0.01) and PM10 (OR = 1.078, p = 0.03). On the following day after the air pollution was recorded, NSTEMI was induced by: PM2.5 (OR = 1.093, p = 0.025), PM10 (OR = 1.077, p = 0.025) and SO2 (OR = 1.522, p = 0.009). For STEMI, events that occurred on the day in which air pollution was triggered by: PM2.5 (OR = 1.197, p < 0.001), PM10 (OR = 1.163, p < 0.001), SO2 (OR = 1.670, p = 0.001) and NO2 (OR = 1.287, p = 0.011). On the following day after air pollution was recorded, STEMI was induced by: PM2.5 (OR = 1.172, p < 0.001), PM10 (OR = 1.131, p = 0.001), SO2 (OR = 1.550, p = 0.005) and NO2 (OR = 1.265, p = 0.02). None of the weather conditions indicated were statistically significant for acute myocardial infarction occurrence. CONCLUSIONS: The most important pollutants triggering acute myocardial infarction occurrence in the population of southern Poland, both on the day of air pollution and the following day are particulate matters (PM2.5, PM10) and gaseous pollutants including NO2 and SO2. These pollutants should be regarded as modifiable risk factors and thus, their reduction is a priority in order to decrease total morbidity and mortality in Poland.


Assuntos
Poluição do Ar , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Cidades , União Europeia , Hospitais , Humanos , Polônia
2.
Postepy Kardiol Interwencyjnej ; 12(3): 217-23, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27625684

RESUMO

INTRODUCTION: Despite the dominance of drug-eluting stents in modern interventional cardiology, there is still a niche for bare metal stents. AIM: The aim of the Polish NexGen registry was to evaluate the safety and efficacy of a new generation cobalt-chromium NexGen stent in a real life patient population. MATERIAL AND METHODS: A prospective multi-center registry was conducted in five clinical sites of American Heart of Poland. Three hundred and eighty-three patients who underwent percutaneous coronary intervention (PCI) with NexGen stent implantation were included. Clinical follow-up was performed at 1, 6 and 12 months. Additionally, a group of 42 randomly selected patients underwent control angiography at 6 months (10.96% of study population). The primary endpoint was occurrence of target vessel revascularization (TVR) at 6-month follow-up. Angiographic endpoints included rates of binary restenosis and late lumen loss at 6-month follow-up based on QCA analysis. Multivessel disease was present in more than 70% of patients, and 52.4% of lesions were complex. The main indications for angiography were non-ST elevation acute coronary syndromes (54.8%) and ST elevation myocardial infarction (34.99%). RESULTS: At 6-month follow-up 47 (12.7%) patients reached the primary endpoint of TVR. The composite of major acute cardiac event rates at 30-day and 6- and 12-month follow-up was 6.01% (n = 23), 18.5% (n = 69) and 25.21% (n = 92) respectively. Control angiography performed after 6 months showed in-stent late loss of 0.66 ±0.71 mm and a binary restenosis rate of 16.7%. CONCLUSIONS: Our study showed that PCI with the NexGen stent is safe and effective at 6- and 12-month follow-up. Angiographic results showed a satisfactory restenosis rate and low late lumen loss.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...