Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
BJR Open ; 4(1): 20210049, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36105419

RESUMO

Objectives: To evaluate the effect of bowel dilation on cine-MRI small bowel motility measurements, by comparing a conventional motility score (including bowel wall and lumen) with a bowel wall-specific motility score in healthy and diseased populations. Methods: Four populations were included: 10 Crohn's patients with a stricture and prestricture dilation for segmental motility analysis, and 14 mannitol-prepared healthy subjects, 15 fasted healthy subjects and eight chronic intestinal pseudo-obstruction (CIPO) patients (characterized by dilated bowel loops) for global small bowel motility analysis. All subjects underwent a cine-MRI scan from which two motility scores were calculated: a conventional score (including bowel wall and lumen) and a bowel wall-specific score. The difference between the two scores was calculated per population and compared between groups with a one-way ANOVA and Tukey-Kramer analysis. Results: In Crohn's patients, the median (IQR) change between the conventional and wall-specific motility score was 0% (-2 to +4%) within the stricture and 0% (-1 to +7%) in the prestricture dilation. For the global small bowel, this was -1% (-5 to 0%) in mannitol-prepared healthy subjects, -2% (-6 to +2%) in fasted healthy subjects and +14% (+6 to+20%) in CIPO patients. The difference between the two motility scores in CIPO patients differed significantly from the four other groups (p = 0.002 to p < 0.001). Conclusions: The conventional small bowel motility score seems robust in Crohn's disease patients and healthy subjects. In patients with globally and grossly dilated bowel loops, a bowel-wall specific motility score may give a better representation of small bowel motility. Advances in knowledge: These findings support researchers and clinicians with making informed choices for using cine-MRI motility analysis in different populations.

2.
Neurogastroenterol Motil ; 34(10): e14381, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35438218

RESUMO

BACKGROUND: Gastrointestinal symptoms in functional gut disorders occur without any discernible structural gut abnormality. Preliminary observations on enteric MRI suggest possible abnormal content and motility of the terminal ileum (TI) in constipation-predominant IBS (IBS-C) with severe bloating, and in functional bloating and distension (FABD) patients. We investigated whether MRI can quantify differences in small bowel (SB) content and motility between patients and healthy controls (HCs). METHODS: 11 IBS-C (mean age 40 [21-52] years; 10 women) and 7 FABD (36 [21-56]; all women) patients with bloating and 20 HCs (28 [22-48]; 6 women) underwent enteric MRI, including dynamic motility and anatomical sequences. Three texture analysis (TA) parameters assessed the homogeneity of the luminal content, with ratios calculated between the TI and (1) the SB and (2) the ascending colon. Four TI motility metrics were derived. Ascending colon diameter (ACD) was measured. A comparison between HCs and patients was performed independently for: (1) three TA parameters, (2) four TI motility metrics, and (3) ACD. KEY RESULTS: Compared with HCs, patients had TI:colon ratios higher for TA contrast (p < 0.001), decreased TI motility (lower mean motility [p = 0.04], spatial motility variation [p = 0.03], and area of motile TI [p = 0.03]), and increased ACD (p = 0.001). CONCLUSIONS AND INFERENCES: IBS-C and FABD patients show reduced TI motility and differences in luminal content compared with HCs. This potentially indicates reflux of colonic contents or delayed clearance of the TI, which alongside increased ACD may contribute to symptoms of constipation and bloating.


Assuntos
Gastroenteropatias , Síndrome do Intestino Irritável , Adulto , Constipação Intestinal/diagnóstico por imagem , Feminino , Flatulência , Gastroenteropatias/diagnóstico por imagem , Humanos , Intestino Delgado/diagnóstico por imagem , Síndrome do Intestino Irritável/diagnóstico por imagem , Imageamento por Ressonância Magnética
3.
J Cyst Fibros ; 21(3): 502-505, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34922853

RESUMO

People with cystic fibrosis (CF) experience digestive symptoms but the mechanisms are incompletely understood. Here we explore causes and consequences of slower gastrointestinal transit using magnetic resonance imaging (MRI). Twelve people with CF and 12 healthy controls, matched for age and gender, underwent MRI scans, both fasted and after standardised meals, over 6.5 h. Fasted small bowel motility scores were lower in CF than in controls. No difference in ascending colon chyme T1 was detected. The difference in texture between small bowel and colon contents, seen in health, was diminished in CF. The ascending colon in CF participants had an abnormal appearance compared to controls. MRI offers unique potential to evaluate gut luminal content, colonic mucosa and intestinal motor activity. These new data support the theoretical cycle of desiccation, dysmotility and delayed transit as a cause of gastrointestinal symptoms in CF.


Assuntos
Fibrose Cística , Motilidade Gastrointestinal , Trato Gastrointestinal , Trânsito Gastrointestinal , Humanos , Imageamento por Ressonância Magnética
4.
Abdom Radiol (NY) ; 46(10): 4660-4670, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34148103

RESUMO

PURPOSE: MR elastography and magnetization-tagging use liver stiffness (LS) measurements to diagnose fibrosis but require physical drivers, specialist sequences and post-processing. Here we evaluate non-rigid registration of dynamic two-dimensional cine MRI images to measure cardiac-induced liver deformation (LD) as a measure of LS by (i) assessing preclinical proof-of-concept, (ii) clinical reproducibility and inter-reader variability, (iii) the effects of hepatic hemodynamic changes and (iv) feasibility in patients with cirrhosis. METHODS: Sprague-Dawley rats (n = 21 bile duct ligated (BDL), n = 17 sham-operated controls) and fasted patients with liver cirrhosis (n = 11) and healthy volunteers (HVs, n = 10) underwent spoiled gradient-echo short-axis cardiac cine MRI studies at 9.4 T (rodents) and 3.0 T (humans). LD measurements were obtained from intrahepatic sub-cardiac regions-of-interest close to the diaphragmatic margin. One-week reproducibility and prandial stress induced hemodynamic changes were assessed in healthy volunteers. RESULTS: Normalized LD was higher in BDL (1.304 ± 0.062) compared with sham-operated rats (1.058 ± 0.045, P = 0.0031). HV seven-day reproducibility Bland-Altman (BA) limits-of-agreement (LoAs) were ± 0.028 a.u. and inter-reader variability BA LoAs were ± 0.030 a.u. Post-prandial LD increases were non-significant (+ 0.0083 ± 0.0076 a.u., P = 0.3028) and uncorrelated with PV flow changes (r = 0.42, p = 0.2219). LD measurements successfully obtained from all patients were not significantly higher in cirrhotics (0.102 ± 0.0099 a.u.) compared with HVs (0.080 ± 0.0063 a.u., P = 0.0847). CONCLUSION: Cardiac-induced LD is a conceptually reasonable approach from preclinical studies, measurements demonstrate good reproducibility and inter-reader variability, are less likely to be affected by hepatic hemodynamic changes and are feasible in patients with cirrhosis.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Animais , Estudos de Viabilidade , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
5.
Top Magn Reson Imaging ; 30(1): 31-41, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33528210

RESUMO

ABSTRACT: In this review article, we present the latest developments in quantitative imaging biomarkers based on magnetic resonance imaging (MRI), applied to the diagnosis, assessment of response to therapy, and assessment of prognosis of Crohn disease. We also discuss the biomarkers' limitations and future prospects. We performed a literature search of clinical and translational research in Crohn disease using diffusion-weighted MRI (DWI-MRI), dynamic contrast-enhanced MRI (DCE-MRI), motility MRI, and magnetization transfer MRI, as well as emerging topics such as T1 mapping, radiomics, and artificial intelligence. These techniques are integrated in and combined with qualitative image assessment of magnetic resonance enterography (MRE) examinations. Quantitative MRI biomarkers add value to MRE qualitative assessment, achieving substantial diagnostic performance (area under receiver-operating curve = 0.8-0.95). The studies reviewed show that the combination of multiple MRI sequences in a multiparametric quantitative fashion provides rich information that may help for better diagnosis, assessment of severity, prognostication, and assessment of response to biological treatment. However, the addition of quantitative sequences to MRE examinations has potential drawbacks, including increased scan time and the need for further validation before being used in therapeutic drug trials as well as the clinic.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/metabolismo , Imageamento por Ressonância Magnética/métodos , Inteligência Artificial , Biomarcadores/metabolismo , Meios de Contraste , Doença de Crohn/patologia , Humanos
6.
Eur Radiol ; 31(2): 775-784, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32833090

RESUMO

OBJECTIVES: Investigate the relationship between quantified terminal ileal (TI) motility and histopathological activity grading, Crohn Disease MRI Index (CDMI) and faecal calprotectin. METHODS: Retrospective review of children with Crohn disease or unclassified inflammatory bowel disease, who underwent MR enterography. Dynamic imaging for 25 patients (median age 12, range 5 to 16) was analysed with a validated motility algorithm. The TI motility score was derived. The primary reference standard was TI Endoscopic biopsy Assessment of Inflammatory Activity (eAIS) within 40 days of the MR enterography. Secondary reference standards: (1) the Crohn Disease MRI Index (CDMI) and (2) faecal calprotectin levels. RESULTS: MR enterography median motility score was 0.17 a.u. (IQR 0.12 to 0.25; range 0.05 to 0.55), and median CDMI was 3 (IQR 0 to 5.5). Forty-three percent of patients had active disease (eAIS > 0) with a median eAIS score of 0 (IQR 0 to 2; range 0 to 5). The correlation between eAIS and motility was r = - 0.58 (p = 0.004, N = 23). Between CDMI and motility, r = - 0.42 (p = 0.037, N = 25). Motility score was lower in active disease (median 0.12 vs 0.21, p = 0.020) while CDMI was higher (median 5 vs 1, p = 0.04). In a subset of 12 patients with faecal calprotectin within 3 months of MR enterography, correlation with motility was r = - 0.27 (p = 0.4). CONCLUSIONS: Quantified terminal ileum motility decreases with increasing histopathological abnormality in children with Crohn disease, reproducing findings in adults. TI motility showed a negative correlation with an MRI activity score but not with faecal calprotectin levels. KEY POINTS: • It is feasible to perform MRI quantified bowel motility assessment in children using free-breathing techniques. • Bowel motility in children with Crohn disease decreases as the extent of intestinal inflammation increases. • Quantified intestinal motility may be a candidate biomarker for treatment efficacy in children with Crohn disease.


Assuntos
Doença de Crohn , Adulto , Criança , Doença de Crohn/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Íleo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos
7.
J Magn Reson Imaging ; 53(5): 1422-1431, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33331088

RESUMO

BACKGROUND: Increased small bowel permeability leads to bacterial translocation, associated with significant morbidity and mortality. Biomarkers are needed to evaluate these changes in vivo, stratify an individual's risk, and evaluate the efficacy of interventions. MRI is an established biomarker of small bowel inflammation. PURPOSE: To characterize changes in the small bowel with quantitative MRI measures associated with increased permeability induced by indomethacin. STUDY TYPE: Prospective single-center, double-blind, two-way crossover provocation study. SUBJECTS: A provocation cohort (22 healthy volunteers) and intrasubject reproducibility cohort (8 healthy volunteers). FIELD STRENGTH/SEQUENCE: 2D balanced turbo field echo sequences to measure small bowel wall thickness, T2 , and motility acquired at 3T. ASSESSMENT: Participants were randomized to receive indomethacin or placebo prior to assessment. After a minimum 2-week washout, measures were repeated with the alternative allocation. MR measures (wall thickness, T2 , motility) at each study visit were compared to the reference standard 2-hour lactulose/mannitol urinary excretion ratio (LMR) test performed by a lab technician. All analyses were performed blind. STATISTICAL TESTS: Normality was tested (Shapiro-Wilk's test). Paired testing (Student's t-test or Wilcoxon) determined the significance of paired differences with indomethacin provocation. Pearson's correlation coefficient compared significant measures with indomethacin provocation to LMR. Intrasubject (intraclass correlation) and interrater variability (Bland-Altman) were assessed. RESULTS: Indomethacin provocation induced a significant increase in LMR compared to placebo (P < 0.05) and a significant increase in small bowel T2 (0.12 seconds compared to placebo 0.07 seconds, P < 0.05). Small bowel wall thickness (P = 0.17) and motility (P = 0.149) showed no significant change. T2 and LMR were positively correlated (r = 0.68, P < 0.05). T2 measurements were robust to interobserver (intraclass correlation 0.89) and intrasubject variability (Bland-Altman bias of 0.005 seconds, 95% confidence interval [CI] -0.04 to +0.05 seconds, and 0.0006 seconds, 95% CI -0.05 to +0.06 seconds). DATA CONCLUSION: MR measures of small bowel wall T2 were significantly increased following indomethacin provocation and correlated with 2-hour LMR test results. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Intestino Delgado , Imageamento por Ressonância Magnética , Humanos , Intestino Delgado/diagnóstico por imagem , Permeabilidade , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
PLoS One ; 15(11): e0241441, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33175860

RESUMO

OBJECTIVE: The gastrointestinal environment in which drug products need to disintegrate before the drug can dissolve and be absorbed has not been studied in detail due to limitations, especially invasiveness of existing techniques. Minimal in vivo data is available on undisturbed gastrointestinal motility to improve relevance of predictive dissolution models and in silico tools such as physiologically-based pharmacokinetic models. Recent advances in magnetic resonance imaging methods could provide novel data and insights that can be used as a reference to validate and, if necessary, optimize these models. The conventional method for measuring gastrointestinal motility is via a manometric technique involving intubation. Nevertheless, it is feasible to measure gastrointestinal motility with magnetic resonance imaging. The aim of this study was is to develop and validate a magnetic resonance imaging method using the most recent semi-automated analysis method against concomitant perfused manometry method. MATERIAL AND METHODS: Eighteen healthy fasted participants were recruited for this study. The participants were intubated with a water-perfused manometry catheter. Subsequently, stomach motility was assessed by cine-MRI acquired at intervals, of 3.5min sets, at coronal oblique planes through the abdomen and by simultaneous water perfused manometry, before and after administration of a standard bioavailability / bioequivalence 8 ounces (~240mL) drink of water. The magnetic resonance imaging motility images were analysed using Spatio-Temporal Motility analysis STMM techniques. The area under the curve of the gastric motility contractions was calculated for each set and compared between techniques. The study visit was then repeated one week later. RESULTS: Data from 15 participants was analysed. There was a good correlation between the MRI antral motility plots area under the curve and corresponding perfused manometry motility area under the curve (r = 0.860) during both antral contractions and quiescence. CONCLUSION: Non-invasive dynamic magnetic resonance imaging of gastric antral motility coupled with recently developed, semi-automated magnetic resonance imaging data processing techniques correlated well with simultaneous, 'gold standard' water perfused manometry. This will be particularly helpful for research purposes related to oral absorption where the absorption of a drug is highly depending on the underlying gastrointestinal processes such as gastric emptying, gastrointestinal motility and availability of residual fluid volumes. CLINICAL TRIAL: This trial was registered at ClinicalTrials.gov as NCT03191045.


Assuntos
Jejum/fisiologia , Motilidade Gastrointestinal/fisiologia , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Manometria , Antro Pilórico/diagnóstico por imagem , Antro Pilórico/fisiologia , Água/farmacologia , Adulto , Área Sob a Curva , Disponibilidade Biológica , Feminino , Motilidade Gastrointestinal/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Antro Pilórico/efeitos dos fármacos , Equivalência Terapêutica , Fatores de Tempo , Adulto Jovem
9.
Neurogastroenterol Motil ; 32(11): e13942, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32677154

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) of the colonic response to a macrogol challenge drink can be used to assess the mechanisms underlying severe constipation. We measured the intrasubject reproducibility of MRI measures of colonic function to aid their implementation as a possible clinical test. METHODS: Healthy participants attended for MRI on two occasions (identical protocols, minimum 1 week apart). They underwent a fasted scan and then consumed the macrogol drink. Subjects were scanned at 60 and 120 minutes, with maximum value reached used for comparison. The colonic volume, water content, mixing of colonic content and the movement of the colon walls were measured. Coefficients of variation and intraclass correlation coefficients (ICC) were calculated. RESULTS: Twelve participants completed the study: nine female, mean age 26 years (SD 5) and body mass index 24.8 kg/m2 (SD 3.2). All measures consistently increased above baseline following provocation with macrogol. The volume, water content and content mixing had good intrasubject reproducibility (ICC volume = 0.84, water content = 0.93, mixing = 0.79, P < .001). With the wall movement, the response to the challenge was generally large, but more variable between visits resulting in a lower ICC overall (ascending colon = 0.65, descending colon = 0.76, P < .001). CONCLUSIONS: The colonic response to the macrogol stimulus as assessed by MRI is heterogeneous but large compared to baseline, with moderate to good reproducibility, making the test suitable to study potential pathologies underlying GI disorders such as constipation. More data are needed to better define the normal range for comparison with patient groups who may have both hypo- and hypermotile responses.


Assuntos
Colo/diagnóstico por imagem , Colo/fisiologia , Motilidade Gastrointestinal , Polietilenoglicóis , Tensoativos , Adulto , Colo/fisiopatologia , Constipação Intestinal/fisiopatologia , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão , Projetos Piloto , Reprodutibilidade dos Testes , Água , Adulto Jovem
10.
Nutrients ; 12(7)2020 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-32707726

RESUMO

(1) Background: Intestinal failure-associated liver disease (IFALD) in adults is characterized by steatosis with variable progression to fibrosis/cirrhosis. Reference standard liver biopsy is not feasible for all patients, but non-invasive serological and quantitative MRI markers for diagnosis/monitoring have not been previously validated. Here, we examine the potential of serum scores and feasibility of quantitative MRI used in non-IFALD liver diseases for the diagnosis of IFALD steatosis; (2) Methods: Clinical and biochemical parameters were used to calculate serum scores in patients on home parenteral nutrition (HPN) with/without IFALD steatosis. A sub-group underwent multiparameter quantitative MRI measurements of liver fat fraction, iron content, tissue T1, liver blood flow and small bowel motility; (3) Results: Compared to non-IFALD (n = 12), patients with IFALD steatosis (n = 8) demonstrated serum score elevations in Enhanced Liver Fibrosis (p = 0.032), Aspartate transaminase-to-Platelet Ratio Index (p < 0.001), Fibrosis-4 Index (p = 0.010), Forns Index (p = 0.001), Gamma-glutamyl transferase-to-Platelet Ratio Index (p = 0.002) and Fibrosis Index (p = 0.001). Quantitative MRI scanning was feasible in all 10 sub-group patients. Median liver fat fraction was higher in IFALD steatosis patients (10.9% vs 2.1%, p = 0.032); other parameter differences were non-significant; (4) Conclusion: Serum scores used for non-IFALD liver diseases may be useful in IFALD steatosis. Multiparameter MRI is feasible in patients on HPN.


Assuntos
Fígado Gorduroso/diagnóstico , Fígado Gorduroso/etiologia , Enteropatias/complicações , Imageamento por Ressonância Magnética , Tecido Adiposo/metabolismo , Adulto , Idoso , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Estudos de Coortes , Estudos Transversais , Fígado Gorduroso/patologia , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Nutrição Parenteral no Domicílio , Contagem de Plaquetas , gama-Glutamiltransferase/sangue
11.
Am J Clin Nutr ; 111(1): 131-140, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31557279

RESUMO

BACKGROUND: Crohn's disease (CD) patients suffer postprandial aversive symptoms, which can lead to anorexia and malnutrition. Changes in the regulation of gut hormones and gut dysmotility are believed to play a role. OBJECTIVES: This study aimed to investigate small-bowel motility and gut peptide responses to a standard test meal in CD by using MRI. METHODS: We studied 15 CD patients with active disease (age 36 ± 3 y; BMI 26 ± 1 kg/m 2) and 20 healthy volunteers (HVs; age 31 ± 3 years; BMI 24 ± 1 kg/m 2). They underwent baseline and postprandial MRI scans, symptom questionnaires, and blood sampling following a 400-g soup meal (204 kcal). Small-bowel motility, other MRI parameters, and glucagon-like peptide-1 (GLP-1), polypeptide YY (PYY), and cholecystokinin peptides were measured. Data are presented as means ± SEMs. RESULTS: HVs had significantly higher fasting motility indexes [106 ± 13 arbitrary units (a.u.)], compared with CD participants (70 ± 8 a.u.; P ≤ 0.05). Postprandial small-bowel water content showed a significant time by group interaction (P < 0.05), with CD participants showing higher levels from 210 min postprandially. Fasting concentrations of GLP-1 and PYY were significantly greater in CD participants, compared with HVs [GLP-1, CD 50 ± 8 µg/mL versus HV 13 ± 3 µg/mL (P ≤ 0.0001); PYY, CD 236 ± 16 pg/mL versus HV 118 ± 12 pg/mL (P ≤ 0.0001)]. The meal challenge induced a significant postprandial increase in aversive symptom scores (fullness, distention, bloating, abdominal pain, and sickness) in CD participants compared with HVs (P ≤ 0.05). CONCLUSIONS: The decrease in fasting small-bowel motility noted in CD participants can be ascribed to the increased fasting gut peptides. A better understanding of the etiology of aversive symptoms in CD will facilitate identification of better therapeutic targets to improve nutritional status. This trial was registered at clinicaltrials.gov as NCT03052465.


Assuntos
Doença de Crohn/metabolismo , Doença de Crohn/fisiopatologia , Hormônios Gastrointestinais/sangue , Intestino Delgado/fisiopatologia , Adulto , Idoso , Colecistocinina/sangue , Doença de Crohn/diagnóstico por imagem , Jejum/metabolismo , Feminino , Motilidade Gastrointestinal , Peptídeo 1 Semelhante ao Glucagon/sangue , Humanos , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Peptídeo YY/sangue , Período Pós-Prandial , Adulto Jovem
12.
Neurogastroenterol Motil ; 31(5): e13557, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30821098

RESUMO

BACKGROUND: MRI is increasingly used to objectively assess gastrointestinal motility. However, motility metrics often do not offer insights into the nature of contractile action. This study introduces a systematic method of making spatio-temporal measurements of contractions, based on changes in bowel lumen diameter. METHODS: Two heterogeneous cohorts of subjects were selected displaying gastric (n = 15) and colonic motility (n = 20) on which to test the spatio-temporal motility MRI (STMM) technique. STMM involved delineating the bowel lumen along with inner and outer bowel wall along a section of the gastrointestinal tract. A series of diameter measurements were made automatically across the central axis of the lumen. Measurements were automatically propagated through the time series using a previously validated algorithm. Contractions were quantitatively summarized with two methods measuring (a) normalized contraction plot (NCP) and (b) combined velocity distance (CVD) both of which can be visualized as spatio-temporal motility maps. Both metrics were correlated against subjective visual scoring systems. KEY RESULTS: Good correlation was seen between reader scores and both motility metrics (NCP, R = 0.85, P < 0.001, CVD, R = 0.93, R < 0.001) in the gastric data. Good correlation was also seen between the reader scores and the two metrics in the colonic data (NCP, R = 0.82, P < 0.001, CVD, R = 0.78, R < 0.001). CONCLUSIONS AND INFERENCES: Spatio-temporal motility MRI analysis of the stomach and colon correlates well with reader scores in a range of datasets and provides both a quantitative and qualitative means of assessing contractile activity in the gastrointestinal tract.


Assuntos
Colo , Motilidade Gastrointestinal , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estômago , Adulto , Feminino , Humanos , Masculino
13.
Neurogastroenterol Motil ; 31(1): e13466, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30230099

RESUMO

BACKGROUND: The symptoms of functional bowel disorders are common in postprandial but investigations are generally undertaken in the fasted state using invasive procedures. MRI provides a noninvasive tool to study the gastrointestinal tract in an unperturbed, fed state. The aim of this study was to develop a technique to assess small bowel motility from cine MRI data in the unprepared bowel in fasting and fed states. METHODS: Fifteen healthy volunteers underwent a baseline MRI scan after which they consumed a 400 g soup. Subjects then underwent a postprandial scan followed by further scans at regular intervals. Small bowel motility was assessed using single-slice bTFE cine MRI. An optimized processing technique was used to generate motility data based on power spectrum analysis of voxel-signal changes with time. Interobserver variability (n = 15) and intra-observer (n = 6) variability were assessed. Changes in the motility index were compared between fasted and immediate postprandial state. KEY RESULTS: Excellent agreement between observers was seen across the range of motility measurements acquired, with intraclass correlation coefficient (ICC) of 0.979 (P < 0.0001) and Bland-Altman limits of agreement 95% CI: -28.9 to 45.9 au. Intra-observer variability was low with ICC of 0.992 and 0.960 (2 observers, P < 0.0001). Changes from the fasted to immediately postprandial state showed an average increase of 122.4% ± 98.7% (n = 15). CONCLUSIONS & INFERENCES: This optimized technique showed excellent inter and intra observer agreement. It was sensitive to changes in motility induced feeding. This technique will be useful to study contractile activity and regional patterns along the gastrointestinal tract under physiological conditions.


Assuntos
Motilidade Gastrointestinal , Processamento de Imagem Assistida por Computador/métodos , Intestino Delgado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Jejum , Feminino , Gastroenteropatias/diagnóstico por imagem , Humanos , Masculino , Variações Dependentes do Observador , Período Pós-Prandial
14.
Neurogastroenterol Motil ; 31(2): e13506, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30407694

RESUMO

OBJECTIVE: MRI is increasingly used to evaluate small bowel contractility. The objective of this study was to validate a clinically practical stimulation test (300-kcal meal) for small bowel motility. METHODS: Thirty-one healthy subjects underwent dynamic MRI to capture global small bowel motility after ±10h fasting, of which 15 underwent bowel preparation consisting of 1 L 2.5% mannitol solution and 16 did not. Each subject underwent (1) a baseline motility scan (2) a food challenge (3) a post-challenge scan, and (4) second post-challenge scan (after ±20 minutes). This protocol was repeated within 2 weeks. Motility was quantified using a validated motility assessment technique. KEY RESULTS: Motility in prepared subjects at baseline was significantly higher than motility in unprepared subjects (0.36 AU vs 0.18 AU, P < 0.001). In the prepared group, the food challenge produced an 8% increase in motility (P = 0.33) while in the unprepared subjects a significant increase of 30% was observed (P < 0.001). Responses to food remained insignificant (P = 0.21) and significant (P = 0.003), for the prepared and unprepared subjects, respectively, ±20 minutes post food challenge. These results were confirmed in the repeated scan session. CONCLUSION & INFERENCES: A significant response to a 300-kcal meal was measured within 10 minutes in unprepared bowel, supporting the clinical use of this challenge to provoke and assess motility changes. A caloric challenge did not produce an observable increase in motility in mannitol prepared subjects.


Assuntos
Motilidade Gastrointestinal/fisiologia , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Jejum , Feminino , Humanos , Masculino , Refeições
15.
Radiology ; 289(2): 428-435, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30129901

RESUMO

Purpose To evaluate the accuracy of MRI-quantified small bowel motility for Crohn disease activity against endoscopic and histopathologic reference standards. Materials and Methods For this prospective study, 82 participants (median age, 31 years; range, 16 to 70 years; 42 males [median age, 31 years; range, 17 to 70 years] and 40 females [median age, 31 years; range, 16 to 63 years) underwent colonoscopy and MR enterography within 14 days (from October 2011 to March 2014) at two centers. The Crohn disease endoscopic index of severity (CDEIS), histopathologic activity score (endoscopic biopsy acute histologic inflammatory score [EAIS]), and MR index of activity (MaRIA) were scored in the terminal ileum. Terminal ileal motility was quantified by using an image registration based-motility assessment algorithm (hereafter, Motility). Sensitivity and specificity of Motility (˂0.3 arbitrary units) and MaRIA (≥7 and ≥11) for disease activity (CDEIS ≥4 or EAIS ≥1) were compared by using the McNemar test. Receiver operating characteristic curves were constructed and areas under the curve were compared. Motility was correlated with reference standards by using Spearman rank estimates. Results Terminal ileal Motility was negatively correlated with EAIS (r =-0.61; 95% confidence interval [CI]: 0.7, -0.5) and CDEIS (r = -0.59; 95% CI: 0.7, -0.4). With CDEIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥11) (93% vs 78%, respectively; P = .03), but lower specificity (61% vs 81%, respectively; P = .04). With EAIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥7) (92% vs 75%, respectively; P = .03) but similar specificity (71% vs 74%, respectively; P >.99). The area under the receiver operating characteristic curve for Motility was 0.86 and 0.87 with CDEIS and EAIS as the standard of reference, respectively. Conclusion The terminal ileal Motility score showed good agreement with endoscopic and histopathologic activity in Crohn disease. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/fisiopatologia , Íleo/diagnóstico por imagem , Íleo/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto Jovem
16.
Br J Radiol ; 91(1089): 20170914, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29888980

RESUMO

OBJECTIVE: Previous single-centre MRI data suggests an inverse correlation between normal small bowel motility variance and abdominal symptoms in Crohn's disease (CD) patients. The current work prospectively assesses this observation in a larger, two-centre study. METHODS: MR enterography datasets were analysed from 82 patients (38 male, aged 16-68), who completed a contemporaneous Harvey-Bradshaw index (HBI) questionnaire. Dynamic "cine motility" breath-hold balanced steady-state free precession sequences were acquired through the whole small bowel (SB) volume. Regions of interest (ROIs) were manually applied to encompass all morphologically normal SB (i.e. excluding Crohn's affected bowel) and a validated registration technique used to produce motility maps. Mean and variance motility metrics were correlated with HBI and symptom components (well-being, pain and diarrhoea) using Spearman's correlation statistics. RESULTS: Overall, motility variance was non-significantly negatively correlated with the total HBI score, (r = -0.17, p = 0.12), but for subjects with a HBI score over 10, the negative correlation was significant (r = -0.633, p = 0.027). Motility variance was negatively correlated with diarrhoea (r = -0.29, p < 0.01). No significant correlation was found between mean motility and HBI (r = -0.02, p = 0.84). CONCLUSION: An inverse association between morphologically normal small bowel motility variance and patient symptoms has been prospectively confirmed in patients with HBI scores above 10. This association is particularly apparent for the symptom of diarrhoea. Advances in knowledge: This study builds on preliminary work by confirming in a large, well-controlled prospective multicentre study a relationship between normal bowel motility variance and patient reported symptoms which may have implications for drug development and clinical management.


Assuntos
Doença de Crohn/diagnóstico por imagem , Motilidade Gastrointestinal , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Doença de Crohn/diagnóstico , Doença de Crohn/fisiopatologia , Feminino , Humanos , Intestino Delgado/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Inquéritos e Questionários , Adulto Jovem
17.
Acad Radiol ; 25(8): 1038-1045, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29428210

RESUMO

RATIONALE AND OBJECTIVES: The objective of this study was to develop and validate a predictive magnetic resonance imaging (MRI) activity score for ileocolonic Crohn disease activity based on both subjective and semiautomatic MRI features. MATERIALS AND METHODS: An MRI activity score (the "virtual gastrointestinal tract [VIGOR]" score) was developed from 27 validated magnetic resonance enterography datasets, including subjective radiologist observation of mural T2 signal and semiautomatic measurements of bowel wall thickness, excess volume, and dynamic contrast enhancement (initial slope of increase). A second subjective score was developed based on only radiologist observations. For validation, two observers applied both scores and three existing scores to a prospective dataset of 106 patients (59 women, median age 33) with known Crohn disease, using the endoscopic Crohn's Disease Endoscopic Index of Severity (CDEIS) as a reference standard. RESULTS: The VIGOR score (17.1 × initial slope of increase + 0.2 × excess volume + 2.3 × mural T2) and other activity scores all had comparable correlation to the CDEIS scores (observer 1: r = 0.58 and 0.59, and observer 2: r = 0.34-0.40 and 0.43-0.51, respectively). The VIGOR score, however, improved interobserver agreement compared to the other activity scores (intraclass correlation coefficient = 0.81 vs 0.44-0.59). A diagnostic accuracy of 80%-81% was seen for the VIGOR score, similar to the other scores. CONCLUSIONS: The VIGOR score achieves comparable accuracy to conventional MRI activity scores, but with significantly improved reproducibility, favoring its use for disease monitoring and therapy evaluation.


Assuntos
Colo/diagnóstico por imagem , Doença de Crohn/diagnóstico por imagem , Íleo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
18.
Br J Radiol ; 91(1088): 20170845, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29474115

RESUMO

OBJECTIVE: Dynamic imaging of small intestinal motility is an increasingly common research method to examine bowel physiology in health and disease. However, limited data exist to guide imaging protocols with respect to quantitative analysis. The purpose of this study is to define the required temporal resolution and scan duration in dynamic MRI for small bowel motility assessment. METHODS: Six healthy volunteers underwent motility imaging with MR enterography using breath-hold protocol. A coronal two-dimensional balanced fast field echo sequence was used to acquire dynamic data at a high temporal resolution of 10 frames per second (fps). Motility was quantified by generating a registration-derived motility index for local and global regions of bowel. To evaluate temporal resolution and scan duration, the data were undersampled and the scan length was varied to determine the impact on motility index. RESULTS: The mean motility index stabilizes at a temporal resolution of 1 fps (median absolute percentage change 1.4% for global and 1.9% for local regions of interest). The mean motility index appears to stabilize for scan durations of 15 s or more in breath-hold (median absolute % change 2.8% for global and 1.7% for local regions of interest). CONCLUSION: A temporal resolution of at least 1 fps and a scan duration of at least 15 s is necessary in breath-hold scans for consistent motility observations. The majority of small bowel motility studies to date are in line with these requirements. Advances in knowledge: This study suggests the minimum temporal resolution and scan duration required in breath-hold scans to obtain robust measurements of small bowel motility from MRI.


Assuntos
Motilidade Gastrointestinal , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Adulto Jovem
19.
Br J Radiol ; 90(1074): 20160654, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28401775

RESUMO

OBJECTIVE: To evaluate a semi-automatic method for delineation of the bowel wall and measurement of the wall thickness in patients with Crohn's disease. METHODS: 53 patients with suspected or proven Crohn's disease were selected. Two radiologists independently supervised the delineation of regions with active Crohn's disease on MRI, yielding manual annotations (Ano1, Ano2). Three observers manually measured the maximal bowel wall thickness of each annotated segment. An active contour segmentation approach semi-automatically delineated the bowel wall. For each active region, two segmentations (Seg1, Seg2) were obtained by independent observers, in which the maximum wall thickness was automatically determined. The overlap between (Seg1, Seg2) was compared with the overlap of (Ano1, Ano2) using Wilcoxon's signed rank test. The corresponding variances were compared using the Brown-Forsythe test. The variance of the semi-automatic thickness measurements was compared with the overall variance of manual measurements through an F-test. Furthermore, the intraclass correlation coefficient (ICC) of semi-automatic thickness measurements was compared with the ICC of manual measurements through a likelihood-ratio test. RESULTS: Patient demographics: median age, 30 years; interquartile range, 25-38 years; 33 females. The median overlap of the semi-automatic segmentations (Seg1 vs Seg2: 0.89) was significantly larger than the median overlap of the manual annotations (Ano1 vs Ano2: 0.72); p = 1.4 × 10-5. The variance in overlap of the semi-automatic segmentations was significantly smaller than the variance in overlap of the manual annotations (p = 1.1 × 10-9). The variance of the semi-automated measurements (0.46 mm2) was significantly smaller than the variance of the manual measurements (2.90 mm2, p = 1.1 × 10-7). The ICC of semi-automatic measurement (0.88) was significantly higher than the ICC of manual measurement (0.45); p = 0.005. CONCLUSION: The semi-automatic technique facilitates reproducible delineation of regions with active Crohn's disease. The semi-automatic thickness measurement sustains significantly improved interobserver agreement. Advances in knowledge: Automation of bowel wall thickness measurements strongly increases reproducibility of these measurements, which are commonly used in MRI scoring systems of Crohn's disease activity.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Reprodutibilidade dos Testes
20.
PLoS One ; 12(1): e0168317, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28072831

RESUMO

MRI has recently been applied as a tool to quantitatively evaluate the response to therapy in patients with Crohn's disease, and is the preferred choice for repeated imaging. Bowel wall thickness on MRI is an important biomarker of underlying inflammatory activity, being abnormally increased in the acute phase and reducing in response to successful therapy; however, a poor level of interobserver agreement of measured thickness is reported and therefore a system for accurate, robust and reproducible measurements is desirable. We propose a novel method for estimating bowel wall-thickness to improve the poor interobserver agreement of the manual procedure. We show that the variability of wall thickness measurement between the algorithm and observer measurements (0.25mm ± 0.81mm) has differences which are similar to observer variability (0.16mm ± 0.64mm).


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Imageamento por Ressonância Magnética , Modelos Estatísticos , Adulto , Algoritmos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Fluxo de Trabalho , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...