Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 65(1): 159-164, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28459677

RESUMO

OBJECTIVE: Fluctuations in response to levodopa in Parkinson's disease (PD) are difficult to treat as tools to monitor temporal patterns of symptoms are hampered by several challenges. The objective was to use wearable sensors to quantify the dose response of tremor, bradykinesia, and dyskinesia in individuals with PD. METHODS: Thirteen individuals with PD and fluctuating motor benefit were instrumented with wrist and ankle motion sensors and recorded by video. Kinematic data were recorded as subjects completed a series of activities in a simulated home environment through transition from off to on medication. Subjects were evaluated using the unified Parkinson disease rating scale motor exam (UPDRS-III) at the start and end of data collection. Algorithms were applied to the kinematic data to score tremor, bradykinesia, and dyskinesia. A blinded clinician rated severity observed on video. Accuracy of algorithms was evaluated by comparing scores with clinician ratings using a receiver operating characteristic (ROC) analysis. RESULTS: Algorithm scores for tremor, bradykinesia, and dyskinesia agreed with clinician ratings of video recordings (ROC area > 0.8). Summary metrics extracted from time intervals before and after taking medication provided quantitative measures of therapeutic response (p < 0.01). Radar charts provided intuitive visualization, with graphical features correlated with UPDRS-III scores (R = 0.81). CONCLUSION: A system with wrist and ankle motion sensors can provide accurate measures of tremor, bradykinesia, and dyskinesia as patients complete routine activities. SIGNIFICANCE: This technology could provide insight on motor fluctuations in the context of daily life to guide clinical management and aid in development of new therapies.


Assuntos
Monitoramento de Medicamentos/métodos , Discinesias/diagnóstico , Levodopa/uso terapêutico , Doença de Parkinson/tratamento farmacológico , Dispositivos Eletrônicos Vestíveis , Idoso , Algoritmos , Fenômenos Biomecânicos , Estudos de Coortes , Monitoramento de Medicamentos/instrumentação , Discinesias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/fisiopatologia , Curva ROC
2.
Parkinsonism Relat Disord ; 21(4): 378-82, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25703990

RESUMO

BACKGROUND: Deep brain stimulation (DBS) is a well-established treatment for Parkinson's disease (PD). Optimization of DBS settings can be a challenge due to the number of variables that must be considered, including presence of multiple motor signs, side effects, and battery life. METHODS: Nine PD subjects visited the clinic for programming at approximately 1, 2, and 4 months post-surgery. During each session, various stimulation settings were assessed and subjects performed motor tasks while wearing a motion sensor to quantify tremor and bradykinesia. At the end of each session, a clinician determined final stimulation settings using standard practices. Sensor-based ratings of motor symptom severities collected during programming were then used to develop two automated programming algorithms--one to optimize symptom benefit and another to optimize battery life. Therapeutic benefit was compared between the final clinician-determined DBS settings and those calculated by the automated algorithm. RESULTS: Settings determined using the symptom optimization algorithm would have reduced motor symptoms by an additional 13 percentage points when compared to clinician settings, typically at the expense of increased stimulation amplitude. By adding a battery life constraint, the algorithm would have been able to decrease stimulation amplitude by an average of 50% while maintaining the level of therapeutic benefit observed using clinician settings for a subset of programming sessions. CONCLUSIONS: Objective assessment in DBS programming can identify settings that improve symptoms or obtain similar benefit as clinicians with improvement in battery life. Both options have the potential to improve post-operative patient outcomes.


Assuntos
Estimulação Encefálica Profunda , Hipocinesia/terapia , Doença de Parkinson/terapia , Avaliação de Resultados da Assistência ao Paciente , Tremor/terapia , Idoso , Automação/instrumentação , Automação/métodos , Automação/normas , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Estimulação Encefálica Profunda/normas , Feminino , Humanos , Hipocinesia/diagnóstico , Masculino , Pessoa de Meia-Idade , Tremor/diagnóstico
3.
J Parkinsons Dis ; 4(4): 609-15, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25208729

RESUMO

BACKGROUND: Dyskinesia throughout the levodopa dose cycle has been previously measured in patients with Parkinson's disease (PD) using a wrist-worn motion sensor during the stationary tasks of arms resting and extended. Quantifying dyskinesia during unconstrained activities poses a unique challenge since these involuntary movements are kinematically similar to voluntary movement. OBJECTIVE: To determine the feasibility of using motion sensors to measure dyskinesia during activities of daily living. METHODS: Fifteen PD subjects performed scripted activities of daily living while wearing motion sensors on bilateral hands, thighs, and ankles over the course of a levodopa dose cycle. Videos were scored by clinicians using the modified Abnormal Involuntary Movement Scale to rate dyskinesia severity in separate body regions, with the total score used as an overall measure. Kinematic features were extracted from the motion data and algorithms were generated to output severity scores. RESULTS: Movements when subjects were experiencing dyskinesia were less smooth than when they were not experiencing dyskinesia. Dyskinesia scores predicted by the model using all sensors were highly correlated with clinician scores, with a correlation coefficient of 0.86 and normalized root-mean-square-error of 7.4%. Accurate predictions were maintained when two sensors on the most affected side of the body (one on the upper extremity and one on the lower extremity) were used. CONCLUSIONS: A system with motion sensors may provide an accurate measure of overall dyskinesia that can be used to monitor patients as they complete typical activities, and thus provide insight on symptom fluctuation in the context of daily life.


Assuntos
Atividades Cotidianas , Discinesias/diagnóstico , Discinesias/etiologia , Percepção de Movimento/fisiologia , Adulto , Idoso , Algoritmos , Antiparkinsonianos/efeitos adversos , Feminino , Mãos/fisiopatologia , Humanos , Levodopa/efeitos adversos , Masculino , Pessoa de Meia-Idade , Movimento , Doença de Parkinson/complicações , Doença de Parkinson/tratamento farmacológico , Índice de Gravidade de Doença
4.
J Parkinsons Dis ; 3(3): 399-407, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23948993

RESUMO

BACKGROUND: Chronic use of medication for treating Parkinson's disease (PD) can give rise to peak-dose dyskinesia. Adjustments in medication often sacrifice control of motor symptoms, and thus balancing this trade-off poses a significant challenge for disease management. OBJECTIVE: To determine whether a wrist-worn motion sensor unit could be used to ascertain global dyskinesia severity over a levodopa dose cycle and to develop a severity scoring algorithm highly correlated with clinician ratings. METHODS: Fifteen individuals with PD were instrumented with a wrist-worn motion sensor unit, and data were collected with arms in resting and extended positions once every hour for three hours after taking a levodopa dose. Two neurologists blinded to treatment status viewed subject videos and rated global and upper extremity dyskinesia severity based on the modified Abnormal Involuntary Movement Scale (mAIMS). Linear regression models were developed using kinematic features extracted from motion sensor data and extremity, global, or combined (average of extremity and global) mAIMS scores. RESULTS: Dyskinesia occurring during a levodopa dose cycle was successfully measured using a wrist-worn sensor. The logarithm of the power spectrum area between 0.3-3 Hz and the combined clinician scores resulted in the best model performance, with a correlation coefficient between clinician and model scores of 0.81 and root mean square error of 0.55, both averaged across the arms resting and extended postures. CONCLUSIONS: One sensor unit worn on either hand can effectively predict global dyskinesia severity during the arms resting or extended positions.


Assuntos
Antiparkinsonianos/efeitos adversos , Discinesia Induzida por Medicamentos/diagnóstico , Levodopa/efeitos adversos , Doença de Parkinson/complicações , Adulto , Idoso , Algoritmos , Antiparkinsonianos/uso terapêutico , Fenômenos Biomecânicos , Feminino , Humanos , Levodopa/uso terapêutico , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Exame Neurológico , Doença de Parkinson/tratamento farmacológico , Tremor/fisiopatologia , Punho/fisiologia
5.
Gait Posture ; 38(1): 109-14, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23218768

RESUMO

Gait and balance disturbances in Parkinson's disease (PD) can be debilitating and may lead to increased fall risk. Deep brain stimulation (DBS) is a treatment option once therapeutic benefits from medication are limited due to motor fluctuations and dyskinesia. Optimizing DBS parameters for gait and balance can be significantly more challenging than for other PD motor symptoms. Furthermore, inter-rater reliability of the standard clinical PD assessment scale, Unified Parkinson's Disease Rating Scale (UPDRS), may introduce bias and washout important features of gait and balance that may respond differently to PD therapies. Study objectives were to evaluate clinician UPDRS gait and balance scoring inter-rater reliability, UPDRS sensitivity to different aspects of gait and balance, and how kinematic features extracted from motion sensor data respond to stimulation. Forty-two subjects diagnosed with PD were recruited with varying degrees of gait and balance impairment. All subjects had been prescribed dopaminergic medication, and 20 subjects had previously undergone DBS surgery. Subjects performed seven items of the gait and balance subset of the UPDRS while wearing motion sensors on the sternum and each heel and thigh. Inter-rater reliability varied by UPDRS item. Correlation coefficients between at least one kinematic feature and corresponding UPDRS scores were greater than 0.75 for six of the seven items. Kinematic features improved (p<0.05) from DBS-OFF to DBS-ON for three UPDRS items. Despite achieving high correlations with the UPDRS, evaluating individual kinematic features may help address inter-rater reliability issues and rater bias associated with focusing on different aspects of a motor task.


Assuntos
Estimulação Encefálica Profunda , Transtornos Neurológicos da Marcha/diagnóstico , Doença de Parkinson/diagnóstico , Equilíbrio Postural , Transtornos de Sensação/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Estudos de Avaliação como Assunto , Feminino , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doença de Parkinson/complicações , Doença de Parkinson/terapia , Reprodutibilidade dos Testes , Transtornos de Sensação/etiologia , Transtornos de Sensação/terapia , Resultado do Tratamento
6.
J Neurosci Methods ; 203(1): 152-6, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-21978487

RESUMO

Patients with Parkinson's disease (PD) receive therapies aimed at addressing a diverse range of motor symptoms. Motor complications in the form of symptom fluctuations and dyskinesias that commonly occur with chronic PD medication use may not be effectively captured by Unified Parkinson's Disease Rating Scale (UPDRS) assessments performed in the clinic. Therefore, home monitoring may be a viable adjunct tool to provide insight into PD motor symptom response to treatment. In this pilot study, we sought to evaluate the feasibility of capturing PD motor symptoms at home using a computer-based assessment system. Ten subjects diagnosed with idiopathic PD used the system at home and ten non-PD control subjects used the system in a laboratory. The Kinesia system consists of a wireless finger-worn motion sensor and a laptop computer with software for automated tremor and bradykinesia severity score assessments. Data from control subjects were used to develop compliance algorithms for rejecting motor tasks performed incorrectly. These algorithms were then applied to data collected from the PD subjects who used the Kinesia system at home to complete motor exams 3-6 times per day over 3-6 days. Motor tasks not rejected by the compliance algorithms were further processed for symptom severity. PD subjects successfully completed motor assessments at home, with approximately 97% of all motor task data files (1222/1260) accepted. These findings suggest that objective home monitoring of PD motor fluctuations is feasible.


Assuntos
Algoritmos , Discinesia Induzida por Medicamentos/diagnóstico , Monitorização Ambulatorial/métodos , Atividade Motora/fisiologia , Doença de Parkinson/diagnóstico , Antiparkinsonianos/efeitos adversos , Computadores , Feminino , Humanos , Levodopa/efeitos adversos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/tratamento farmacológico , Cooperação do Paciente , Software
7.
Artigo em Inglês | MEDLINE | ID: mdl-23365855

RESUMO

The objective was to capture levodopa-induced dyskinesia (LID) in patients with Parkinson's disease (PD) using body-worn motion sensors. Dopaminergic treatment in PD can induce abnormal involuntary movements, including choreatic dyskinesia (brief, rapid, irregular movements). Adjustments in medication to reduce LID often sacrifice control of motor symptoms, and balancing this tradeoff poses a significant challenge for management of advanced PD. Fifteen PD subjects with known LID were recruited and instructed to perform two stationary motor tasks while wearing a compact wireless motion sensor unit positioned on each hand over the course of a levodopa dose cycle. Videos of subjects performing the motor tasks were later scored by expert clinicians to assess global dyskinesia using the modified Abnormal Involuntary Rating Scale (m-AIMS). Kinematic features were extracted from motion data in different frequency bands (1-3Hz and 3-8Hz) to quantify LID severity and to distinguish between LID and PD tremor. Receiver operator characteristic analysis was used to determine thresholds for individual features to detect the presence of LID. A sensitivity of 0.73 and specificity of 1.00 were achieved. A neural network was also trained to output dyskinesia severity on a 0 to 4 scale, similar to the m-AIMS. The model generalized well to new data (coefficient of determination= 0.85 and mean squared error= 0.3). This study demonstrated that hand-worn motion sensors can be used to assess global dyskinesia severity independent of PD tremor over the levodopa dose cycle.


Assuntos
Antiparkinsonianos/efeitos adversos , Discinesia Induzida por Medicamentos , Levodopa/efeitos adversos , Modelos Biológicos , Monitorização Fisiológica , Doença de Parkinson , Tecnologia sem Fio , Idoso , Antiparkinsonianos/administração & dosagem , Fenômenos Biomecânicos , Discinesia Induzida por Medicamentos/diagnóstico , Discinesia Induzida por Medicamentos/fisiopatologia , Feminino , Humanos , Levodopa/administração & dosagem , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento (Física) , Doença de Parkinson/tratamento farmacológico , Doença de Parkinson/fisiopatologia
8.
Artigo em Inglês | MEDLINE | ID: mdl-23366299

RESUMO

The objective was to develop and evaluate algorithms for quantifying gait and lower extremity bradykinesia in patients with Parkinson's disease using kinematic data recorded on a heel-worn motion sensor unit. Subjects were evaluated by three movement disorder neurologists on four domains taken from the Movement Disorders Society Unified Parkinson's Disease Rating Scale while wearing the motion sensor unit. Multiple linear regression models were developed based on the recorded kinematic data and clinician scores and produced outputs highly correlated to clinician scores with an average correlation coefficient of 0.86. The newly developed models have been integrated into a home-based system for monitoring Parkinson's disease motor symptoms.


Assuntos
Marcha/fisiologia , Hipocinesia/fisiopatologia , Extremidade Inferior/fisiopatologia , Movimento (Física) , Telemetria/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/fisiopatologia
9.
Phys Sportsmed ; 39(3): 83-93, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22030944

RESUMO

BACKGROUND: Previous studies have shown that single bouts of high-rate active cycling (> 80 rpm) improve upper extremity motor function in individuals with Parkinson's disease (PD). It is unknown if passive leg cycling produces a similar effect on upper extremity function. This article examines whether passive leg cycling can promote immediate changes in upper tremor and bradykinesia in PD and if pedaling rates have variable effects. METHODS: Twenty individuals with mild-to-moderate idiopathic PD completed 4 sessions, with each session taking place 1 week apart. In the second to fourth sessions, a motorized bicycle was set to passively rotate the subjects' legs at rates of 60, 70, or 80 rpm for 30 minutes. Quantitative upper extremity motor assessments were completed immediately before and after each session. RESULTS: Passive leg cycling was shown to reduce tremor and bradykinesia in PD. However, the rate of passive cycling did not affect the degree of improvement in bradykinesia or tremor. CONCLUSION: These findings suggest that lower extremity passive cycling can promote changes in upper extremity motor function in individuals with PD.


Assuntos
Ciclismo/fisiologia , Terapia por Exercício/métodos , Hipocinesia/fisiopatologia , Hipocinesia/reabilitação , Perna (Membro)/fisiologia , Doença de Parkinson/fisiopatologia , Doença de Parkinson/reabilitação , Tremor/fisiopatologia , Tremor/reabilitação , Extremidade Superior/fisiopatologia , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/tratamento farmacológico , Resultado do Tratamento
10.
J Neurosci Methods ; 177(1): 20-9, 2009 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18930079

RESUMO

Rigidity is a cardinal symptom of Parkinson's disease and is frequently used as an outcome measure in clinical and non-human primate studies examining the effects of medication or surgical intervention. A limitation of current rigidity assessment methods is that they are inherently subjective. To better understand the physiological mechanisms of rigidity and how various therapeutic approaches work, a more objective and quantitative method is needed. In this study, an automated arm rigidity testing (ART) system was developed to objectively quantify rigidity while the primate's limb was moved between two user-specified angles. Recordings of normal force versus elbow-angle were categorized according to area and slope. These quantitative measures of rigidity were investigated in three rhesus macaque monkeys treated with 1-methyl 4-phenyl 1,2,3,6-tetrahydropyridine and compared with clinical assessment methods. The ART system incorporates electromyographical recordings that can detect and differentiate active from actual resistance. The ART system detected significant changes in rigidity measures following administration of apomorphine or deep brain stimulation of the globus pallidus internus. The most sensitive measures were total area, extension slope, and flexion slope. The ART system provides precise and reliable measures of rigidity that are objective and quantitative.


Assuntos
Braço/fisiopatologia , Intoxicação por MPTP/complicações , Intoxicação por MPTP/patologia , Rigidez Muscular/fisiopatologia , Animais , Antiparkinsonianos/farmacologia , Apomorfina/farmacologia , Estimulação Encefálica Profunda/métodos , Modelos Animais de Doenças , Eletromiografia/métodos , Processamento Eletrônico de Dados , Feminino , Intoxicação por MPTP/terapia , Macaca mulatta , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiopatologia , Amplitude de Movimento Articular/efeitos dos fármacos , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...