Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(10): 103506, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319395

RESUMO

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium "micro-flag" target driven by the Advanced Radiographic Capability laser (∼2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

2.
Appl Radiat Isot ; 71 Suppl: 75-80, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22494894

RESUMO

A Monte Carlo calculation, using the MCNPX code, was carried out in order to estimate the photon and neutron spectra in two locations of two linacs operating at 15 and 18 MV. Detailed models of both linac heads were used in the calculations. Spectra were estimated below the flattening filter and at the isocenter. Neutron spectra show two components due to evaporation and knock-on neutrons. Lethargy spectra under the filter were compared to the spectra calculated from the function quoted by Tosi et al. that describes reasonably well neutron spectra beyond 1 MeV, though tends to underestimate the energy region between 10(-6) and 1 MeV. Neutron and the Bremsstrahlung spectra show the same features regardless of the linac voltage.


Assuntos
Nêutrons , Aceleradores de Partículas , Fótons , Método de Monte Carlo
3.
Radiat Prot Dosimetry ; 118(3): 251-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16223751

RESUMO

An artificial neural network (ANN) has been designed to obtain neutron doses using only the count rates of a Bonner spheres spectrometer (BSS). Ambient, personal and effective neutron doses were included. One hundred and eighty-one neutron spectra were utilised to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in the BSS and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing were carried out in the MATLAB environment. The impact of uncertainties in BSS count rates upon the dose quantities calculated with the ANN was investigated by modifying by +/-5% the BSS count rates used in the training set. The use of ANNs in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated with this ill-conditioned problem.


Assuntos
Algoritmos , Modelos Biológicos , Redes Neurais de Computação , Nêutrons , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Análise Espectral/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Modelos Estatísticos , Doses de Radiação , Monitoramento de Radiação/instrumentação , Eficiência Biológica Relativa , Análise Espectral/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...