Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pers Med ; 12(9)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36143224

RESUMO

For patients who suffer from severe dysfunction of the temporomandibular joint (TMJ), a total joint replacement (TJR) in the form of a prosthesis may be indicated. The position of the centre of rotation in TJRs is crucial for good postoperative oral function; however, it is not determined patient-specifically (PS) in any current TMJ-TJR. The aim of this current study was to develop a 4D-workflow to ascertain the PS mean axis of rotation, or fixed hinge, that mimics the patient's specific physiological mouth opening. Twenty healthy adult patients were asked to volunteer for a 4D-scanning procedure. From these 4D-scanning recordings of mouth opening exercises, patient-specific centres of rotation and axes of rotation were determined using our JawAnalyser tool. The mean CR location was positioned 28 [mm] inferiorly and 5.5 [mm] posteriorly to the centre of condyle (CoC). The 95% confidence interval ranged from 22.9 to 33.7 [mm] inferior and 3.1 to 7.8 [mm] posterior to the CoC. This study succeeded in developing an accurate 4D-workflow to determine a PS mean axis of rotation that mimics the patient's specific physiological mouth opening. Furthermore, a change in concept is necessary for all commercially available TMJ-TJR prostheses in order to comply with the PS CRs calculated by our study. In the meantime, it seems wise to stick to placing the CR 15 [mm] inferiorly to the CoC, or even beyond, towards 28 [mm] if the patient's anatomy allows this.

2.
J Pers Med ; 12(8)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-36013222

RESUMO

Over the past decade, the demand for three-dimensional (3D) patient-specific (PS) modelling and simulations has increased considerably; they are now widely available and generally accepted as part of patient care. However, the patient specificity of current PS designs is often limited to this patient-matched fit and lacks individual mechanical aspects, or parameters, that conform to the specific patient's needs in terms of biomechanical acceptance. Most biomechanical models of the mandible, e.g., finite element analyses (FEA), often used to design reconstructive implants or total joint replacement devices for the temporomandibular joint (TMJ), make use of a literature-based (mean) simplified muscular model of the masticatory muscles. A muscle's cross-section seems proportionally related to its maximum contractile force and can be multiplied by an intrinsic strength constant, which previously has been calculated to be a constant of 37 [N/cm2]. Here, we propose a contemporary method to determine the patient-specific intrinsic strength value of the elevator mouth-closing muscles. The hypothesis is that patient-specific individual mandible elevator muscle forces can be approximated in a non-invasive manner. MRI muscle delineation was combined with bite force measurements and 3D-FEA to determine PS intrinsic strength values. The subject-specific intrinsic strength values were 40.6 [N/cm2] and 25.6 [N/cm2] for the 29- and 56-year-old subjects, respectively. Despite using a small cohort in this proof of concept study, we show that there is great variation between our subjects' individual muscular intrinsic strength. This variation, together with the difference between our individual results and those presented in the literature, emphasises the value of our patient-specific muscle modelling and intrinsic strength determination protocol to ensure accurate biomechanical analyses and simulations. Furthermore, it suggests that average muscular models may only be sufficiently accurate for biomechanical analyses at a macro-scale level. A future larger cohort study will put the patient-specific intrinsic strength values in perspective.

3.
JAMA Netw Open ; 4(2): e2037519, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33599774

RESUMO

Importance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments. Objective: To determine the feasibility and accuracy of a novel concept of fast-track 3-dimensional (3-D) virtual surgical planning and patient-specific osteosynthesis for complex acetabular fracture surgery. Design, Setting, and Participants: This case series study examines the use of patient-specific osteosynthesis plates for patients needing operative treatment for displaced associated-type acetabular fractures at a tertiary university-affiliated referral center and level 1 trauma center between January 1, 2017, and December 31, 2018. Models were created in 3-D based on computed tomography (CT) data, fractures were virtually reduced, and implant positions were discussed in a multidisciplinary team of clinicians and engineers. Patient-specific osteosynthesis plates with drilling guides were designed, produced, sterilized and clinically applied within 4 days. Data were analyzed at the 1-year follow-up. Exposures: Development and clinical implementation of personalized fracture surgery. Main Outcomes and Measures: The primary outcome was the quality of the reduction as determined by the postoperative CT scan. The secondary outcomes were accuracy of the screw placement and clinical outcome using patient-reported outcome measures. Results: Ten patients with a median (range) age of 63 (46-79) years with an acetabular fracture were included. The median (interquartile range [IQR]) preoperative gap was 20 (15-22) mm, and the median (IQR) step-off was 5 (3-11) mm. Postoperatively, the median (IQR) gap was reduced to 3 (2-5) mm (P = .005), and the median (IQR) step-off was reduced to 0 (0-2) mm (P = .01), indicating good fracture reduction, indicating good fracture reduction. The mean difference between the preoperative and postoperative gap was 14.6 (95% CI, 10-19) mm, and the mean difference in step-off was 5.7 (95% CI, 2-9) mm. The median (IQR) difference in screw direction between the planning and actual surgery was only 7.1° (7°-8°). All patients retained their native hip and reported good physical functioning at follow-up. Conclusions and Relevance: These findings suggest that 3-D virtual surgical planning, manufacturing, and clinical application of patient-specific osteosynthesis plates and drilling guides was feasible and yielded good clinical outcomes. Fast-track personalized surgical treatment could open a new era for the treatment of complex injuries.


Assuntos
Acetábulo/lesões , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Acetábulo/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Indústria Manufatureira , Pessoa de Meia-Idade , Modelos Anatômicos , Medidas de Resultados Relatados pelo Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Int J Implant Dent ; 6(1): 23, 2020 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-32588142

RESUMO

BACKGROUND: Templates aim to facilitate implant placement in the prosthetically preferred position. Mucosa-supported and bone-supported templates are commonly used in the edentulous maxilla. In the atrophic maxilla (Cawood V and VI), however, these templates can be easily displaced due to a lack of supportive tissues, even in cases where anterior sites offer sufficient bone for implant placement. To assist in positioning and stabilisation, we designed a template that utilises the nasal aperture as a fulcrum to create a forced and exclusive fit. The aim of this study was to assess the clinical usability of the developed template and the corresponding implant placement accuracy in patients with edentulous atrophic maxillae. Deviations between planned and placed implant positions were measured by aligning pre- and post-operative cone beam computed tomography scans. RESULTS: Twenty-four implants were placed in 11 patients. One template did not fit properly due to a slight undercut. All implants could be placed with good primary stability. The implants had high accuracy at the implant shoulder (global deviation 1.1 ± 0.5 mm, lateral deviation 0.8 ± 0.5 mm) and a mean angular deviation of 7.2 ± 3.4°. CONCLUSIONS: The developed surgical template offers stabilised and secure template placement in the edentulous atrophic maxilla, resulting in satisfying implant placement accuracy when using a semi-guided approach. TRIAL REGISTRATION: Netherlands Trial Register, NL6561, registered 26 September 2017.

5.
Oral Dis ; 26(6): 1265-1274, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32176821

RESUMO

INTRODUCTION: When the application of a free vascularised flap is not possible, a segmental mandibular defect is often reconstructed using a conventional reconstruction plate. Mechanical failure of such reconstructions is mostly caused by plate fracture and screw pull-out. This study aims to develop a reliable, mechanically superior, yet slender patient-specific reconstruction plate that reduces failure due to these causes. PATIENTS AND METHODS: Eight patients were included in the study. Indications were as follows: fractured reconstruction plate (2), loosened screws (1) and primary reconstruction of a mandibular continuity defect (5). Failed conventional reconstructions were studied using finite element analysis (FEA). A 3D virtual surgical plan (3D-VSP) with a novel patient-specific (PS) titanium plate was developed for each patient. Postoperative CBCT scanning was performed to validate reconstruction accuracy. RESULTS: All PS plates were placed accurately according to the 3D-VSP. Mean 3D screw entry point deviation was 1.54 mm (SD: 0.85, R: 0.10-3.19), and mean screw angular deviation was 5.76° (SD: 3.27, R: 1.26-16.62). FEA indicated decreased stress and screw pull-out inducing forces. No mechanical failures appeared (mean follow-up: 16 months, R: 7-29). CONCLUSION: Reconstructing mandibular continuity defects with bookshelf-reconstruction plates with FEA underpinning the design seems to reduce the risk of screw pull-out and plate fractures.

6.
J Nucl Med ; 61(3): 469-476, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31420497

RESUMO

The sensitivity of radiomic features to several confounding factors, such as reconstruction settings, makes clinical use challenging. To investigate the impact of harmonized image reconstructions on feature consistency, a multicenter phantom study was performed using 3-dimensionally printed phantom inserts reflecting realistic tumor shapes and heterogeneity uptakes. Methods: Tumors extracted from real PET/CT scans of patients with non-small cell lung cancer served as model for three 3-dimensionally printed inserts. Different heterogeneity pattern were realized by printing separate compartments that could be filled with different activity solutions. The inserts were placed in the National Electrical Manufacturers Association image-quality phantom and scanned various times. First, a list-mode scan was acquired and 5 statistically equal replicates were reconstructed. Second, the phantom was scanned 4 times on the same scanner. Third, the phantom was scanned on 6 PET/CT systems. All images were reconstructed using EANM Research Ltd. (EARL)-compliant and locally clinically preferred reconstructions. EARL-compliant reconstructions were performed without (EARL1) or with (EARL2) point-spread function. Images were analyzed with and without resampling to 2-mm cubic voxels. Images were discretized with a fixed bin width (FBW) of 0.25 and a fixed bin number (FBN) of 64. The intraclass correlation coefficient (ICC) of each scan setup was calculated and compared across reconstruction settings. An ICC above 0.75 was regarded as high. Results: The percentage of features yielding a high ICC was largest for the statistically equal replicates (70%-91% for FBN; 90%-96% for FBW discretization). For scans acquired on the same system, the percentage decreased, but most features still resulted in a high ICC (FBN, 52%-63%; FBW, 75%-85%). The percentage of features yielding a high ICC decreased more in the multicenter setting. In this case, the percentage of features yielding a high ICC was larger for images reconstructed with EARL-compliant reconstructions: for example, 40% for EARL1 and 60% for EARL2 versus 21% for the clinically preferred setting for FBW discretization. When discretized with FBW and resampled to isotropic voxels, this benefit was more pronounced. Conclusion: EARL-compliant reconstructions harmonize a wide range of radiomic features. FBW discretization and a sampling to isotropic voxels enhances the benefits of EARL-compliant reconstructions.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...