Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Stroke Cerebrovasc Dis ; 30(8): 105912, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34130105

RESUMO

BACKGROUND/OBJECTIVE: While postoperative stroke is a known complication of Transcatheter Aortic Valve Implantation (TAVI), predictors of early stroke occurrence have not been specifically reviewed. The objective of this study was to estimate the predictors and incidence of stroke during the first 30 days post-TAVI. METHODS: A cohort of 506 consecutive patients having undergone TAVI between January 2017 and June 2019 was extracted from a prospective database. Preoperative, intraoperative and postoperative characteristics were analyzed by univariate analysis followed by logistic regression to find predictors of the occurrence of stroke or death within the first 30 days after the procedure. RESULTS: Incidence of stroke within 30 days post-TAVI was 4.9%, [CI 95% 3.3-7.2], i.e., 25 strokes. Four out of the 25 patients (16%) with a stroke died within 30 days post-TAVI. After logistic regression analysis, the predictors of early stroke related to TAVI were: CHA2Ds2VASc score ≥ 5 (odds ratio [OR] 2.62; 95% CI: 1.06-6.49; p = .037), supra-aortic access vs. femoral access (OR: 9.00, 95%CI: 2.95-27.44; p = .001) and introduction post-TAVI of a single vs. two or three antithrombotic agents (OR: 5.13; CI 95%: 1.99 to 13.19; p = .001). Over the 30-day period, bleeding occurred in 28 patients (5.5%), in 25 of whom, it was associated with femoral or iliac artery access injury. Anti-thrombotic regimen was not associated with bleeding; two patients out of 48 (4.1%) bled with a single anti-thrombotic regimen vs. 26 patients out of 458 (5.6%) with a dual or triple anti-thrombotic regimen (p = 0.94). The overall 30-day mortality rate was 3.9%, [95% CI 2.5-6.0]. Patients with a single post-TAVI antithrombotic agent (OR: 44.07 [CI 95% 13.45-144.39]; p < .0001) and patients with previous coronary artery bypass surgery or coronary artery stenting (OR: 6.16, [CI 95% 1.99-21.29]; p = .002) were at significantly higher risk of death within the 30-day period. CONCLUSION: In this large-scale single-center retrospective study, a single post-TAVI antithrombotic regimen independently predicted occurrence of early stroke or death. Dual or triple antithrombotic regimen was not associated with a higher risk of bleeding and should be considered as an option in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fibrinolíticos/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Bases de Dados Factuais , Quimioterapia Combinada , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade
2.
J Cardiovasc Echogr ; 30(2): 88-92, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33282646

RESUMO

BACKGROUND: The development of transcatheter aortic valve replacement (TAVR) has led to an improvement in morbidity-mortality in the treatment of severe aortic stenosis in patients at high surgical risk. However, the procedure is not free from life-threatening cardiovascular outcomes and conductive disturbances. The objective of our study was to analyze the prognostic impact of aortic valve calcium score on the occurrence of complications following the procedure. MATERIALS AND METHODS: Patients who have benefited from TAVR with the implantation of new-generation Sapien 3 and Evolut R aortic valve prostheses between January 2017 and July 2018 with the prior realization of a cardiac computed tomography with measurement of the aortic valve calcium score were retrospectively analyzed. Primary endpoint was a composite of death, stroke, and myocardial infarction within a period of 1 month after TAVR. Relation between valvular calcium and conductive disturbances was secondarily analyzed over the same period, and occurrences of high-degree atrioventricular block (paroxysmal or permanent), new-onset left bundle branch block, and the need for permanent or transient cardiac stimulation were associated with the secondary endpoint. RESULTS: Overall, 144 patients were included. The aortic valve calcium score was not significantly higher in patients who reached the primary endpoint (2936 ± 1235 vs. 3051 ± 1440, P = 0.93). Among the 106 patients analyzed after excluding subjects with a prior pacemaker or left bundle branch block, aortic valvular calcium score was not statistically associated with the occurrence of conduction disturbances (3210 ± 1436 vs. 2948 ± 1223, P = 0.31). CONCLUSION: Our results suggest that the measurement of aortic valve calcium score has no prognostic value regarding mortality, cardiovascular events, or conductive disturbances after TAVR using the new generation of valves.

3.
Int J Cardiol ; 236: 381-386, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28238508

RESUMO

BACKGROUND: Selection of appropriate elderly who can benefit from transcatheter aortic valve implantation (TAVI) is challenging. We evaluated the prognosis of this procedure according to the comprehensive geriatric assessment (CGA) based on the multidimensional prognostic index (MPI). METHODS: Prospective observational monocentric study from January 2013 to December 2015. Consecutive patients aged ≥75 who underwent TAVI and a complete CGA were included. Baseline demographic, geriatric and cardiologic data were collected. CGA was used to calculate the MPI score that is divided in three groups according to the mortality risk. Follow up was performed until December 2016 and mortality rate was assessed at one, six and 12months. RESULTS: 116 patients were included. Mean age was 86.2±4.2years, mean European system for cardiac operative risk evaluation (EuroSCORE) was 19.2±11.3%, mean MPI score was 0.39±0.13. Forty-five (38.8%) patients belonged to MPI-1 group, 68 (58.6%) to MPI-2 group and three to MPI-3 group. MPI score and Euroscore were moderately correlated (Spearman correlation coefficient rs=0.27, p=0.0035). Mortality rate was significantly different between MPI groups at six and 12months (p=0.040 and p=0.022). Kaplan Meier survival estimates at one year stratified by MPI groups was significantly different (hazard ratio HR=2.83, 95%confidence interval (CI) 1.38-5.82, p=0.004). Among variables retained to perform logistic regression analysis, the score of instrumental activities of daily living appeared the most relevant (p<0.001). CONCLUSION: This study indicates that CGA based on MPI tool is accurate to predict prognosis in elderly patients undergoing TAVI procedure.


Assuntos
Avaliação Geriátrica/métodos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Mortalidade/tendências , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/tendências
4.
Int J Cardiol ; 140(2): 189-96, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19108909

RESUMO

CONTEXT: Left atrial (LA) volume is a prognosis factor of cardiovascular morbidity in patients with cardiovascular disease (CD). Recent developments of multislice computed tomography (MSCT) have made non invasive coronary angiography reliable for selected patients and new software facilitates truly volume measurements without geometrical assumptions. OBJECTIVE: To define, by using MSCT, LA and left atrial appendage (LAA) volumes in patients with or without CD. METHODS AND RESULTS: In the population of patients referred to our laboratory for a conventional MSCT coronary angiography, 40 individuals without CD (Normal group) and 80 patients with CD (CD group) were prospectively selected. The CD group was constituted from 4 subgroups of patients with either coronary artery disease (n=20), idiopathic dilated cardiomyopathy (n=20), left ventricular hypertrophy (n=20) or severe mitral regurgitation (MR group, n=20). LAA and LA volumes were measured on a commercially available workstation. LA maximal and minimal volumes were lower in Normal group than in CD group, as LA ejection fraction (54+/-10 versus 67+/-20 ml/m(2), p<0.0001; 31+/-8 versus 46+/-20 ml/m(2), p<0.0001; 43+/-8% versus 33+/- 14%, p<0.001). LAA volume was larger in MR group than in Normal group (15+/-7 ml versus 9+/-3 ml, p<0.0001). CONCLUSION: This MSCT study provides normal values of LA and LAA volumes for patients who underwent MSCT coronary angiography and suggests that MSCT is helpful to assess the changes of LA volumes related to various CD.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada Espiral/métodos , Idoso , Idoso de 80 Anos ou mais , Volume Cardíaco , Cardiomiopatia Dilatada/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Prospectivos
5.
Int J Cardiol ; 131(2): 217-24, 2009 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-18177958

RESUMO

BACKGROUND: Left atrial (LA) volume, is related to cardiovascular morbidity. LA enlargement is usually assessed using trans-thoracic echocardiography (TTE). The association of modern multislice computed tomography (MSCT) imaging and new 3D reconstruction software, allows direct cardiac chamber volume measurement without geometrical assumptions. This study was designed to evaluate the maximal (LAmax) and minimal (LAmin) LA volumes during the cardiac cycle using MSCT and TTE approaches. METHODS: We screened 26 consecutive patients referred for coronary imaging using a 64-MSCT scanner and a TTE within 12 h. Contiguous multiphase images were generated from axial MSCT data and semi-automated 3D segmentation technique was applied to generate LA volumes. Using TTE, LA volumes and LA ejection fraction (LAEF) were obtained using five assumptions methods: cubing equation, diameter-length formula, area-length formula, ellipsoidal formula and biplane Simpson rule. RESULTS: Five patients were excluded for inadequate TTE visualization and one for ectopic beats during MSCT. The sample consisted in 20 patients (11 men, age: 56+/-14 years). Using MSCT, LA volumes indexed to body surface area were: LAmax=74+/-27 ml/m(2), LAmin=49+/-26 ml/m(2), with close correlations with TTE measurements and a significant underestimation by all TTE approaches. A close correlation was observed between LAEF using MSCT and TTE Simpson's method: 36+/-14% vs. 37+/-14%, r=0.99, p<0.0001. CONCLUSION: Theses results suggest that the assessment of LA volumes and ejection fraction was reliable using 64-MSCT in patients referred for coronary computed tomography imaging.


Assuntos
Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/patologia , Ecocardiografia/tendências , Feminino , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Tomografia Computadorizada Espiral/tendências
7.
Blood Coagul Fibrinolysis ; 19(3): 235-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18388505

RESUMO

Aspirin inhibits platelet activation and reduces major vascular events in patients with stable coronary artery disease. The extent of platelet inhibition, denoted as aspirin resistance, however, is not always sufficient. A correlation between aspirin resistance as measured by aggregometry and adverse clinical events has been demonstrated. The point-of-care platelet function analyzer PFA-100 is usually used to detect aspirin resistance, but the relation between PFA-100 results and the vascular prognosis is not assessed. We prospectively enrolled 97 patients with stable coronary artery disease who were on aspirin (160 mg per day since 1 month or longer). Aspirin resistance was measured by the PFA-100 analyzer. Median follow-up was 2.5 years and the primary outcome was the composite of death, myocardial infarction, and ischemic cerebral infarction or acute limb ischemia. In our study, 29 patients (29.9%) showed resistance to aspirin, with a higher percentage of female patients (38 vs. 15%; P=0.01). During the follow-up, aspirin resistance was not associated with an increased risk of death, myocardial infarction, or ischemic vascular event compared with the aspirin-sensitive patients (17 vs. 13%; P>0.60). In this cohort of stable coronary artery disease, patients on aspirin dose of 160 mg per day, the aspirin-resistance status based on the PFA-100 results is not associated with a significant increase in major vascular clinical events.


Assuntos
Aspirina/farmacologia , Doença da Artéria Coronariana/tratamento farmacológico , Resistência a Medicamentos , Testes Hematológicos/instrumentação , Inibidores da Agregação Plaquetária/farmacologia , Agregação Plaquetária/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Agregação Plaquetária/fisiologia , Sistemas Automatizados de Assistência Junto ao Leito , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
9.
Int J Cardiol ; 126(2): 204-8, 2008 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-17493696

RESUMO

BACKGROUND: Multidetector row computed tomography (MDCT) is a developing technique mainly used to evaluate the coronary arteries, but less attention has been paid to the coronary venous system. However, with the dramatic technological advancement of percutaneous therapies for heart failure or mitral insufficiency, a better knowledge about the anatomy of the coronary venous system may be of great utility. We sought the efficacy of MDCT imaging to delineate the coronary venous system. METHODS: 16 row MDCT scans were performed in 50 consecutive patients (42 men, age 61+/-15 years, all in sinus rhythm). The inter-individual variability in terms of diameter, distance, angle of the main tributaries of the coronary venous system was reported. RESULTS: The coronary venous system was always visualized. A remnant Thebesian valve was observed in 18 patients, the diameter of the coronary sinus ostium was found 12.2+/-3.6 mm and 15.3+/-3.7 mm respectively in the antero-posterior and supero-inferior directions, the distance between the posterior vein of the left ventricle (PVLV) and the anterior interventricular vein (AIV) was found 108.6+/-15.2 mm with a significant correlation with the mitral annulus diameter (p<.002) and the left ventricular diameter (p<0.01). The left marginal vein (LMV) was more often tortuous when the angle between the LMV and the great cardiac vein was less than 60 degrees (p<0.01). CONCLUSION: 16 row MDCT imaging can be used to investigate non-invasively the coronary venous anatomy and may serve as a useful tool before percutaneous therapies involving the coronary veins.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...