1.
Phys Med Biol ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38527373

RESUMO

Objective.While a constant relative biological effectiveness (RBE) of 1.1 forms the basis for clinical proton therapy, variable RBE models are increasingly being used in plan evaluation. However, there is substantial variation across RBE models, and several newin vitrodatasets have not yet been included in the existing models. In this study, an updatedin vitroproton RBE database was collected and used to examine current RBE model assumptions, and to propose an up-to-date RBE model as a tool for evaluating RBE effects in clinical settings. Approach.A proton database (471 data points) was collected from the literature, almost twice the size of the previously largest model database. Each data point included linear-quadratic model parameters and linear energy transfer (LET). Statistical analyses were performed to test the validity of commonly applied assumptions of phenomenological RBE models, and new model functions were proposed for RBEmaxand RBEmin(RBE at the lower and upper dose limits). Previously published models were refitted to the database and compared to the new model in terms of model performance and RBE estimates. Main results.The statistical analysis indicated that the intercept of the RBEmaxfunction should be a free fitting parameter and RBE estimates were clearly higher for models with free intercept. RBEminincreased with increasing LET, while a dependency of RBEminon the reference radiation fractionation sensitivity ((α/ß)x) did not significantly improve model performance. Evaluating the models, the new model gave overall lowest RMSE and highest R2 score. RBE estimates in the distal part of a Spread-Out-Bragg-Peak in water ((α/ß)x=2.1Gy) were 1.24-1.51 for original models, 1.25-1.49 for refits and 1.42 for the new model. Significance.An updated RBE model based on the currently largest database among published phenomenological models was proposed. Overall, the new model showed better performance compared to refitted published RBE models. .

2.
Sci Rep ; 13(1): 6709, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37185591

RESUMO

Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of [Formula: see text] can be detected at relatively low proton intensities ([Formula: see text] protons/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context of range verification in PT.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Diagnóstico por Imagem , Prótons , Raios gama , Dosagem Radioterapêutica , Método de Monte Carlo , Imagens de Fantasmas
3.
Phys Med Biol ; 66(3): 035004, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33181502

RESUMO

Radiation therapy using protons and heavier ions is a fast-growing therapeutic option for cancer patients. A clinical system for particle imaging in particle therapy would enable online patient position verification, estimation of the dose deposition through range monitoring and a reduction of uncertainties in the calculation of the relative stopping power of the patient. Several prototype imaging modalities offer radiography and computed tomography using protons and heavy ions. A Digital Tracking Calorimeter (DTC), currently under development, has been proposed as one such detector. In the DTC 43 longitudinal layers of laterally stacked ALPIDE CMOS monolithic active pixel sensor chips are able to reconstruct a large number of simultaneously recorded proton tracks. In this study, we explored the capability of the DTC for helium imaging which offers favorable spatial resolution over proton imaging. Helium ions exhibit a larger cross section for inelastic nuclear interactions, increasing the number of produced secondaries in the imaged object and in the detector itself. To that end, a filtering process able to remove a large fraction of the secondaries was identified, and the track reconstruction process was adapted for helium ions. By filtering on the energy loss along the tracks, on the incoming angle and on the particle ranges, 97.5% of the secondaries were removed. After passing through 16 cm water, 50.0% of the primary helium ions survived; after the proposed filtering 42.4% of the primaries remained; finally after subsequent image reconstruction 31% of the primaries remained. Helium track reconstruction leads to more track matching errors compared to protons due to the increased available focus strength of the helium beam. In a head phantom radiograph, the Water Equivalent Path Length error envelope was 1.0 mm for helium and 1.1 mm for protons. This accuracy is expected to be sufficient for helium imaging for pre-treatment verification purposes.


Assuntos
Calorimetria/instrumentação , Hélio , Método de Monte Carlo , Radiografia , Humanos , Imagens de Fantasmas , Prótons
4.
Phys Med Biol ; 65(13): 135012, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32344385

RESUMO

List mode proton imaging relies on accurate reconstruction of the proton most likely path (MLP) through the patient. This typically requires two sets of position sensitive detector systems, one upstream (front) and one downstream (rear) of the patient. However, for a clinical implementation it can be preferable to omit the front trackers (single-sided proton imaging). For such a system, the MLP can be computed from information available through the beam delivery system and the remaining rear tracker set. In this work, we use Monte Carlo simulations to compare a conventional double-sided (using both front and rear detector systems) with a single-sided system (only rear detector system) by evaluating the spatial resolution of proton radiographs (pRad) and proton CT images (pCT) acquired with these set-ups. Both the pencil beam spot size, as well as the spacing between spots was also adjusted to identify the impact of these beam parameters on the image quality. Relying only on the pencil beam central position for computing the MLP resulted in severe image artifacts both in pRad and pCT. Using the recently extended-MLP formalism that incorporate pencil beam uncertainty removed these image artifacts. However, using a more focused pencil beam with this algorithm induced image artifacts when the spot spacing was the same as the beam spot size. The spatial resolution tested with a sharp edge gradient technique was reduced by 40% for single-sided (MTF 10% = 3.0 lp/cm) compared to double-sided (MTF 10% = 4.9 lp/cm) pRad with ideal tracking detectors. Using realistic trackers the difference decreased to 30%, with MTF 10% of 4.0 lp/cm for the realistic double-sided and 2.7 lp/cm for the realistic single-sided setup. When studying an anthropomorphic paediatric head phantom both single- and double-sided set-ups performed similarly where the difference in water equivalent thickness (WET) between the two set-ups were less than 0.01 mm in homogeneous areas of the head. Larger discrepancies between the two set-ups were visible in high density gradients like the facial structures. A complete CT reconstruction of a Catphan[Formula: see text] module was performed. Assuming ideal detectors, the obtained spatial resolution was 5.1 lp/cm for double-sided and 3.8 lp/cm for the single-sided setup. Double- and single-sided pRad with realistic tracker properties returned a spatial resolution of 3.8 lp/cm and 3.2 lp/cm, respectively. Future studies should investigate the development of dedicated reconstruction algorithms targeted for single-sided particle imaging.


Assuntos
Prótons , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Criança , Cabeça/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas , Controle de Qualidade
5.
Sci Rep ; 9(1): 14773, 2019 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-31594973

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

6.
Phys Med ; 63: 87-97, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31221414

RESUMO

PURPOSE: A pixel-based range telescope for tracking particles during proton imaging is described. The detector applies a 3D matrix of stacked Monolithic Active Pixel Sensors with fast readout speeds. This study evaluates different design alternatives of the range telescope on basis of the protons' range accuracy and the track reconstruction efficiency. METHOD: Detector designs with different thicknesses of the energy-absorbing plates between each sensor layer are simulated using the GATE/Geant4 Monte Carlo software. Proton tracks traversing the detector layers are individually reconstructed, and a Bragg curve fitting procedure is applied for the calculation of each proton's range. RESULTS: Simulations show that the setups with 4 mm and thinner absorber layers of aluminum have a low range uncertainty compared to the physical range straggling, systematic errors below 0.3 mm water equivalent thickness and a track reconstruction capability exceeding ten million protons per second. CONCLUSIONS: In order to restrict the total number of layers and to yield the required tracking and range resolution properties, a design recommendation is reached where the proposed range telescope applies 3.5 mm thick aluminum absorber slabs between each sensor layer.


Assuntos
Prótons , Telescópios , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas , Espalhamento de Radiação , Software
7.
Sci Rep ; 9(1): 2011, 2019 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-30765808

RESUMO

Uncertainties in the proton range in tissue during proton therapy limit the precision in treatment delivery. These uncertainties result in expanded treatment margins, thereby increasing radiation dose to healthy tissue. Real-time range verification techniques aim to reduce these uncertainties in order to take full advantage of the finite range of the primary protons. In this paper, we propose a novel concept for real-time range verification based on detection of secondary neutrons produced in nuclear interactions during proton therapy. The proposed detector concept is simple; consisting of a hydrogen-rich converter material followed by two charged particle tracking detectors, mimicking a proton recoil telescopic arrangement. Neutrons incident on the converter material are converted into protons through elastic and inelastic (n,p) interactions. The protons are subsequently detected in the tracking detectors. The information on the direction and position of these protons is then utilized in a new reconstruction algorithm to estimate the depth distribution of neutron production by the proton beam, which in turn is correlated with the primary proton range. In this paper, we present the results of a Monte Carlo feasibility study and show that the proposed concept could be used for real-time range verification with millimetric precision in proton therapy.


Assuntos
Método de Monte Carlo , Nêutrons/uso terapêutico , Terapia com Prótons , Estudos de Viabilidade , Imagens de Fantasmas , Medicina de Precisão , Fatores de Tempo , Água
8.
Sci Rep ; 8(1): 4925, 2018 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-29563507

RESUMO

The prospecting activities for finding new rare earth elements (REE) sources have increased greatly in recent years. One of the main discoveries was announced in 2011 by Japanese researchers who found large quantities of REE on the ocean seafloor at the sea depths greater than 4,000 m. The classic approach to investigate REE in deep sea sediments is to obtain sediment samples by drilling that is followed by laborious laboratory analysis. This is very expensive, time consuming and not appropriate for exploring vast areas. In order to efficiently explore the ocean floor for REE deposits, the further development of affordable sensors is needed. Here, we propose two nuclear techniques for exploring REE in surface deep sea sediments: i) Passive measurement of lutetium-176 radioactivity, appropriate if long-term in-situ measurements are possible, and ii) The use of the neutron sensor attached to a remotely operated vehicle for rapid in-situ measurement of gadolinium by thermal neutron-capture. Since concentrations of lutetium and gadolinium show strong linear correlation to the total REE concentrations in deep sea sediments, it is possible to deduce the total REE content by measuring Lu or Gd concentrations only.