Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lancet Neurol ; 18(12): 1112-1122, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31587955

RESUMO

BACKGROUND: Approximately 20% of traumatic cervical spinal cord injuries result in tetraplegia. Neuroprosthetics are being developed to manage this condition and thus improve the lives of patients. We aimed to test the feasibility of a semi-invasive technique that uses brain signals to drive an exoskeleton. METHODS: We recruited two participants at Clinatec research centre, associated with Grenoble University Hospital, Grenoble, France, into our ongoing clinical trial. Inclusion criteria were age 18-45 years, stability of neurological deficits, a need for additional mobility expressed by the patient, ambulatory or hospitalised monitoring, registration in the French social security system, and signed informed consent. The exclusion criteria were previous brain surgery, anticoagulant treatments, neuropsychological sequelae, depression, substance dependence or misuse, and contraindications to magnetoencephalography (MEG), EEG, or MRI. One participant was excluded because of a technical problem with the implants. The remaining participant was a 28-year-old man, who had tetraplegia following a C4-C5 spinal cord injury. Two bilateral wireless epidural recorders, each with 64 electrodes, were implanted over the upper limb sensorimotor areas of the brain. Epidural electrocorticographic (ECoG) signals were processed online by an adaptive decoding algorithm to send commands to effectors (virtual avatar or exoskeleton). Throughout the 24 months of the study, the patient did various mental tasks to progressively increase the number of degrees of freedom. FINDINGS: Between June 12, 2017, and July 21, 2019, the patient cortically controlled a programme that simulated walking and made bimanual, multi-joint, upper-limb movements with eight degrees of freedom during various reach-and-touch tasks and wrist rotations, using a virtual avatar at home (64·0% [SD 5·1] success) or an exoskeleton in the laboratory (70·9% [11·6] success). Compared with microelectrodes, epidural ECoG is semi-invasive and has similar efficiency. The decoding models were reusable for up to approximately 7 weeks without recalibration. INTERPRETATION: These results showed long-term (24-month) activation of a four-limb neuroprosthetic exoskeleton by a complete brain-machine interface system using continuous, online epidural ECoG to decode brain activity in a tetraplegic patient. Up to eight degrees of freedom could be simultaneously controlled using a unique model, which was reusable without recalibration for up to about 7 weeks. FUNDING: French Atomic Energy Commission, French Ministry of Health, Edmond J Safra Philanthropic Foundation, Fondation Motrice, Fondation Nanosciences, Institut Carnot, Fonds de Dotation Clinatec.


Assuntos
Interfaces Cérebro-Computador , Exoesqueleto Energizado , Neuroestimuladores Implantáveis , Estudo de Prova de Conceito , Quadriplegia/reabilitação , Tecnologia sem Fio , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Espaço Epidural/diagnóstico por imagem , Espaço Epidural/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos , Masculino , Quadriplegia/diagnóstico por imagem , Quadriplegia/cirurgia , Córtex Sensório-Motor/diagnóstico por imagem , Córtex Sensório-Motor/cirurgia , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/reabilitação , Traumatismos da Medula Espinal/cirurgia , Tecnologia sem Fio/instrumentação
2.
Neuromodulation ; 21(2): 149-159, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28685918

RESUMO

BACKGROUND: Brain Computer Interface (BCI) studies are performed in an increasing number of applications. Questions are raised about electrodes, data processing and effectors. Experiments are needed to solve these issues. OBJECTIVE: To develop a simple BCI set-up to easier studies for improving the mathematical tools to process the ECoG to control an effector. METHOD: We designed a simple BCI using transcranial electrodes (17 screws, three mechanically linked to create a common reference, 14 used as recording electrodes) to record Electro-Cortico-Graphic (ECoG) neuronal activities in rodents. The data processing is based on an online self-paced non-supervised (asynchronous) BCI paradigm. N-way partial least squares algorithm together with Continuous Wavelet Transformation of ECoG recordings detect signatures related to motor activities. Signature detection in freely moving rats may activate external effectors during a behavioral task, which involved pushing a lever to obtain a reward. RESULTS: After routine training, we showed that peak brain activity preceding a lever push (LP) to obtain food reward was located mostly in the cerebellar cortex with a higher correlation coefficient, suggesting a strong postural component and also in the occipital cerebral cortex. Analysis of brain activities provided a stable signature in the high gamma band (∼180Hz) occurring within 1500 msec before the lever push approximately around -400 msec to -500 msec. Detection of the signature from a single cerebellar cortical electrode triggers the effector with high efficiency (68% Offline and 30% Online) and rare false positives per minute in sessions about 30 minutes and up to one hour (∼2 online and offline). CONCLUSIONS: In summary, our results are original as compared to the rest of the literature, which involves rarely rodents, a simple BCI set-up has been developed in rats, the data show for the first time long-term, up to one year, unsupervised online control of an effector.


Assuntos
Interfaces Cérebro-Computador , Encéfalo/fisiologia , Potenciais Evocados/fisiologia , Vigília/fisiologia , Algoritmos , Animais , Mapeamento Encefálico , Eletrodos Implantados , Eletroencefalografia , Feminino , Estudos Longitudinais , Sistemas On-Line , Estimulação Física , Desempenho Psicomotor/fisiologia , Ratos , Fatores de Tempo , Interface Usuário-Computador
3.
Sci Rep ; 7(1): 16281, 2017 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-29176638

RESUMO

A tensor-input/tensor-output Recursive Exponentially Weighted N-Way Partial Least Squares (REW-NPLS) regression algorithm is proposed for high dimension multi-way (tensor) data treatment and adaptive modeling of complex processes in real-time. The method unites fast and efficient calculation schemes of the Recursive Exponentially Weighted PLS with the robustness of tensor-based approaches. Moreover, contrary to other multi-way recursive algorithms, no loss of information occurs in the REW-NPLS. In addition, the Recursive-Validation method for recursive estimation of the hyper-parameters is proposed instead of conventional cross-validation procedure. The approach was then compared to state-of-the-art methods. The efficiency of the methods was tested in electrocorticography (ECoG) and magnetoencephalography (MEG) datasets. The algorithms are implemented in software suitable for real-time operation. Although the Brain-Computer Interface applications are used to demonstrate the methods, the proposed approaches could be efficiently used in a wide range of tasks beyond neuroscience uniting complex multi-modal data structures, adaptive modeling, and real-time computational requirements.


Assuntos
Interfaces Cérebro-Computador , Análise dos Mínimos Quadrados , Algoritmos , Eletrocorticografia , Eletroencefalografia , Magnetoencefalografia , Neurociências/métodos , Software
4.
IEEE Trans Neural Syst Rehabil Eng ; 23(1): 10-21, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25014960

RESUMO

A wireless 64-channel ElectroCorticoGram (ECoG) recording implant named WIMAGINE has been designed for various clinical applications. The device is aimed at interfacing a cortical electrode array to an external computer for neural recording and control applications. This active implantable medical device is able to record neural activity on 64 electrodes with selectable gain and sampling frequency, with less than 1 µV(RMS) input referred noise in the [0.5 Hz - 300 Hz] band. It is powered remotely through an inductive link at 13.56 MHz which provides up to 100 mW. The digitized data is transmitted wirelessly to a custom designed base station connected to a PC. The hermetic housing and the antennae have been designed and optimized to ease the surgery. The design of this implant takes into account all the requirements of a clinical trial, in particular safety, reliability, and compliance with the regulations applicable to class III AIMD. The main features of this WIMAGINE implantable device and its architecture are presented, as well as its functional performances and long-term biocompatibility results.


Assuntos
Eletroencefalografia/instrumentação , Tecnologia sem Fio/instrumentação , Animais , Interfaces Cérebro-Computador , Eletrodos Implantados , Eletrônica , Desenho de Equipamento , Humanos , Macaca fascicularis , Macaca mulatta , Teste de Materiais , Próteses Neurais , Processamento de Sinais Assistido por Computador , Software
5.
Artigo em Inglês | MEDLINE | ID: mdl-25570185

RESUMO

The goal of the CLINATEC® Brain Computer Interface (BCI) Project is to improve tetraplegic subjects' quality of life by allowing them to interact with their environment through the control of effectors, such as an exoskeleton. The BCI platform is based on a wireless 64-channel ElectroCorticoGram (ECoG) recording implant WIMAGINE®, designed for long-term clinical application, and a BCI software environment associated to a 4-limb exoskeleton EMY (Enhancing MobilitY). Innovative ECoG signal decoding algorithms will allow the control of the exoskeleton by the subject's brain activity. Currently, the whole BCI platform was tested in real-time in preclinical experiments carried out in nonhuman primates. In these experiments, the exoskeleton arm was controlled by means of the decoded neuronal activity.


Assuntos
Interfaces Cérebro-Computador , Eletrocorticografia , Algoritmos , Animais , Eletrodos Implantados , Eletroencefalografia , Exoesqueleto Energizado , Macaca mulatta , Qualidade de Vida , Processamento de Sinais Assistido por Computador
6.
J Neural Eng ; 9(4): 045010, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22832155

RESUMO

Recently, the N-way partial least squares (NPLS) approach was reported as an effective tool for neuronal signal decoding and brain-computer interface (BCI) system calibration. This method simultaneously analyzes data in several domains. It combines the projection of a data tensor to a low dimensional space with linear regression. In this paper the L1-Penalized NPLS is proposed for sparse BCI system calibration, allowing uniting the projection technique with an effective selection of subset of features. The L1-Penalized NPLS was applied for the binary self-paced BCI system calibration, providing selection of electrodes subset. Our BCI system is designed for animal research, in particular for research in non-human primates.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Análise dos Mínimos Quadrados , Animais , Eletrodos , Haplorrinos , Humanos
7.
Prog Brain Res ; 194: 71-82, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21867795

RESUMO

UNLABELLED: Brain-computer interfaces (BCIs) include stimulators, infusion devices, and neuroprostheses. They all belong to functional neurosurgery. Deep brain stimulators (DBS) are widely used for therapy and are in need of innovative evolutions. Robotized exoskeletons require BCIs able to drive up to 26 degrees of freedom (DoF). We report the nanomicrotechnology development of prototypes for new 3D DBS and for motor neuroprostheses. For this complex project, all compounds have been designed and are being tested. Experiments were performed in rats and primates for proof of concepts and development of the electroencephalogram (EEG) recognition algorithm. METHODS: Various devices have been designed. (A) In human, a programmable multiplexer connecting five tetrapolar (20 contacts) electrodes to one DBS channel has been designed and implanted bilaterally into STN in two Parkinsonian patients. (B) A 50-mm diameter titanium implant, telepowered, including a radioset, emitting ECoG data recorded by a 64-electrode array using an application-specific integrated circuit, is being designed to be implanted in a 50-mm trephine opening. Data received by the radioreceiver are processed through an original wavelet-based Iterative N-way Partial Least Square algorithm (INPLS, CEA patent). Animals, implanted with ECoG recording electrodes, had to press a lever to obtain a reward. The brain signature associated to the lever press (LP) was detected online by ECoG processing using INPLS. This detection allowed triggering the food dispenser. RESULTS: (A) The 3D multiplexer allowed tailoring the electrical field to the STN. The multiplication of the contacts affected the battery life and suggested different implantation schemes. (B) The components of the human implantable cortical BCI are being tested for reliability and toxicology to meet criteria for chronicle implantation in 2012. (C) In rats, the algorithm INPLS could detect the cortical signature with an accuracy of about 80% of LPs on the electrodes with the best correlation coefficient (located over the cerebellar cortex), 1% of the algorithm decisions were false positives. We aim to pilot effectors with DoF up to 3 in monkeys. CONCLUSION: We have designed multielectrodes wireless implants to open the way for BCI ECoG-driven effectors. These technologies are also used to develop new generations of brain stimulators, either cortical or for deep targets. This chapter is aimed at illustrating that BCIs are actually the daily background of DBS, that the evolution of the method involves a growing multiplicity of targets and indications, that new technologies make possible and simpler than before to design innovative solutions to improve DBS methodology, and that the coming out of BCI-driven neuroprostheses for compensation of motor and sensory deficits is a natural evolution of functional neurosurgery.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Interface Usuário-Computador , Algoritmos , Animais , Eletroencefalografia , Epilepsia/terapia , Humanos , Transtornos Mentais/terapia , Doença de Parkinson/terapia , Software
8.
J Neural Eng ; 8(4): 046012, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21659695

RESUMO

In this paper a tensor-based approach is developed for calibration of binary self-paced brain-computer interface (BCI) systems. In order to form the feature tensor, electrocorticograms, recorded during behavioral experiments in freely moving animals (rats), were mapped to the spatial-temporal-frequency space using the continuous wavelet transformation. An N-way partial least squares (NPLS) method is applied for tensor factorization and the prediction of a movement intention depending on neuronal activity. To cope with the huge feature tensor dimension, an iterative NPLS (INPLS) algorithm is proposed. Computational experiments demonstrated the good accuracy and robustness of INPLS. The algorithm does not depend on any prior neurophysiological knowledge and allows fully automatic system calibration and extraction of the BCI-related features. Based on the analysis of time intervals preceding the BCI events, the calibration procedure constructs a predictive model of control. The BCI system was validated by experiments in freely moving animals under conditions close to those in a natural environment.


Assuntos
Análise dos Mínimos Quadrados , Desenho de Prótese , Interface Usuário-Computador , Algoritmos , Animais , Comportamento Animal/fisiologia , Calibragem , Eletroencefalografia , Fenômenos Eletrofisiológicos , Modelos Neurológicos , Modelos Estatísticos , Ratos , Reprodutibilidade dos Testes , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...