Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Front Med (Lausanne) ; 11: 1373260, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38566921

RESUMO

The integration of diagnostic CT scans into PET/CT facilitates a comprehensive single examination, presenting potential advantages for patients seeking a thorough one-shot check-up. The introduction of iodinated contrast media during PET scanning raises theoretical concerns about potential interference with uptake quantification, due to the modification of tissue density on CT. Nevertheless, this impact appears generally insignificant for clinical use, compared to the intrinsic variability of standardized uptake values. On the other hand, with the growing indications of PET, especially 18F-FDG PET, contrast enhancement increases the diagnostic performances of the exam, and provides additional information. This improvement in performance achieved through contrast-enhanced PET/CT must be carefully evaluated considering the associated risks and side-effects stemming from the administration of iodinated contrast media. Within this article, we present a comprehensive literature review of contrast enhanced PET/CT, examining the potential impact of iodinated contrast media on quantification, additional side-effects and the pivotal clinically demonstrated benefits of an all-encompassing examination for patients. In conclusion, the clinical benefits of iodinated contrast media are mainly validated by the large diffusion in PET protocols. Contrary to positive oral contrast, which does not appear to offer any major advantage in patient management, intravenous iodine contrast media provides clinical benefits without significant artifact on images or quantification. However, studies on the benefit-risk balance for patients are still lacking.

2.
J Nucl Cardiol ; 35: 101799, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38185411

RESUMO

Diagnosis and management of cardiac complications of cancer treatment can be challenging. Few PET data suggest a potential role of dynamic perfusion imaging with measurements of absolute myocardial blood flow and flow reserve (MFR). We report the case of a 72-year-old woman with a history of bilateral breast cancer who underwent dynamic cardiac scintigraphy. Relative perfusion analysis was normal, whereas MFR was impaired in all territories suggesting diffuse microvascular dysfunction. Flow parameters derived from dynamic cardiac scintigraphy could thus be an interesting tool in cardio-oncology.


Assuntos
Neoplasias da Mama , Circulação Coronária , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Feminino , Idoso , Neoplasias da Mama/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico
3.
Clin Nucl Med ; 49(1): 74-75, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38015037

RESUMO

ABSTRACT: PSMA-targeted PET agents are mainly involved for prostate cancer; however, unspecific bone uptakes can be challenging for the clinician. We report the case of a 71-year-old man with history of recurrent prostate cancer initially treated by surgery and radiation therapy. 18 F-PSMA 1007 PET/CT was performed. Beside hyperfixing lymph nodes, focal uptake was found in right femoral head with shell subchondral hypofixation and no morphologic correlate on CT. MRI found bilateral osteonecrosis of the femoral head. This case emphasizes that osteonecrosis of the femoral head can mimic a metastasis uptake, even with normal CT, without however the fixation being constant.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Idoso , Cabeça do Fêmur/patologia , Recidiva Local de Neoplasia , Neoplasias da Próstata/patologia , Radioisótopos de Gálio
4.
Clin Nucl Med ; 48(11): 969-970, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756437

RESUMO

ABSTRACT: CZT-SPECT myocardial perfusion enables quantification of myocardial blood flow (MBF). Normal values and thresholds have been accurately defined in PET but remain unclear in SPECT. The aim of this study was to report normal MBF and myocardial flow reserve values in very low-risk patients referred for coronary artery disease screening with dynamic SPECT, in comparison with patients experiencing coronary artery disease. Eighty-four patients (31 male) were analyzed. The mean 10 years risk of fatal cardiovascular events score was 2.7% ± 1.4%. The mean global stress MBF and myocardial flow reserve were 1.6 ± 0.6 mL/min/g and 2.7 ± 0.7.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Circulação Coronária , Miocárdio , Imagem de Perfusão do Miocárdio/métodos
5.
Clin Nucl Med ; 48(8): 716-718, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37200461

RESUMO

ABSTRACT: New 3D-ring CZT systems with low- and medium-energy-range detectors allow for simultaneous dual-isotope lung scintigraphy. We compared 10-, 7-, 5-, and 3-minute acquisitions for 99m Tc and 81m Kr performed simultaneously on StarGuide CZT-SPECT/CT and reframed in 50 patients. Ventilation/perfusion mismatches were calculated (mean, 15.6% ± 28%), and Spearman correlation coefficients of mismatches were 0.994, 0.994, and 0.984 between 10- and 7-, 5-, and 3-minute acquisitions, respectively. No visual difference in image quality or final diagnosis was found. 3D-ring CZT-SPECT with low and medium energy range detectors allows ultrafast dual-isotope lung scintigraphy up to 3 minutes.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tecnécio Tc 99m Sestamibi , Imagem de Perfusão do Miocárdio/métodos
6.
Clin Nucl Med ; 48(6): 536-537, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37019121

RESUMO

ABSTRACT: Lipomatous hypertrophy of the interatrial septum is a rare lesion of the heart. CT and cardiac MR are often sufficient to determine the benign lipomatous nature of the tumor and can avoid the need for histological confirmation. Lipomatous hypertrophy of the interatrial septum contains variable amounts of brown adipose tissue, resulting in different degrees of 18 F-FDG uptake in PET. We report the case of a patient with an interatrial lesion suspected of malignancy, discovered on CT and failing cardiac MR, with initial 18 F-FDG uptake. Final characterization was made thanks to 18 F-FDG PET with ß-blocker premedication, avoiding an invasive procedure.


Assuntos
Septo Interatrial , Neoplasias Cardíacas , Lipoma , Humanos , Fluordesoxiglucose F18 , Propranolol , Hipertrofia , Septo Interatrial/patologia , Lipoma/diagnóstico por imagem , Neoplasias Cardíacas/patologia
9.
J Nucl Med ; 64(2): 260-265, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36109180

RESUMO

The aim of this study was to evaluate the reproducibility of myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurement in patients referred for dynamic SPECT. Methods: We retrospectively analyzed patients referred for myocardial perfusion imaging. SPECT data were acquired on a cadmium zinc telluride-based pinhole cardiac camera in list mode using a stress (251 ± 15 MBq)/rest (512 ± 26 MBq) 1-d 99mTc-tetrofosmin protocol. Kinetic analyses were done with software using a 1-tissue-compartment model and converted to MBF using a previously determined extraction fraction correction. MFR was analyzed and compared globally and regionally. Motion detection was applied, but not attenuation correction. Results: In total, 124 patients (64 male, 60 female) were included, and SPECT acquisitions were twice reconstructed by the same nuclear medicine board-certified physician for 50 patients and by 2 different physicians for 74. Both intra- and interobserver measurements of global MFR had no significant bias (-0.01 [P = 0.94] and 0.01 [P = 0.67], respectively). However, rest MBF and stress MBF were significantly different in global left ventricular evaluation (P = 0.001 and P = 0.002, respectively) and in the anterior territory (P < 0.0001) on interuser analysis. The average coefficient of variation was 15%-30% of the mean stress MBF if the analysis was performed by the same physician or 2 different physicians and was around 20% of the mean MFR independently of the processing physician. Using the MFR threshold of 2, we noticed good intrauser agreement, whereas it was moderate when the users were different (κ = 0.75 [95% CI, 0.56-0.94] vs. 0.56 [95% CI, 0.36-0.75], respectively). Conclusion: Repeated measurements of global MFR by the same physician or 2 different physicians were similar, with an average coefficient of variation of 20%. Better reproducibility was achieved for intrauser MBF evaluation. Automation of processing is needed to improve reproducibility.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Feminino , Variações Dependentes do Observador , Estudos Retrospectivos , Reprodutibilidade dos Testes , Circulação Coronária , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem de Perfusão do Miocárdio/métodos
10.
Clin Nucl Med ; 47(12): 1116-1117, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36127793

RESUMO

ABSTRACT: Statin-associated muscle symptoms are a frequent adverse effect of statin treatment and can lead to a statin-associated myopathy characterized by a significant serum creatine kinase increase. We report the case of an 80-year-old man who presented an increased muscular 18 F-FDG uptake in a statin-associated muscle symptom without creatine kinase abnormality or inflammation. Statin treatment was discontinued for 6 hours, 3 days, and 7 days on consecutive follow-up examinations. The 1-week window clearly enhanced image quality. This case illustrates the possibility of diffuse muscular 18 F-FDG uptake without myositis and the need for a minimal 1-week statin discontinuation to reduce muscular uptake.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Doenças Musculares , Miosite , Masculino , Humanos , Idoso de 80 Anos ou mais , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Fluordesoxiglucose F18 , Melhoria de Qualidade , Miosite/induzido quimicamente , Miosite/diagnóstico por imagem , Doenças Musculares/induzido quimicamente , Creatina Quinase
11.
J Nucl Cardiol ; 29(1): 113-122, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32651801

RESUMO

BACKGROUND: Regadenoson is a selective adenosine receptor agonist. It is currently unclear if the level of hyperemia differs between stress agents. We compared Myocardial Blood Flow (MBF) and Myocardial Flow Reserve (MFR) response on CZT-SPECT Myocardial Perfusion Imaging (MPI) to evaluate if dipyridamole and regadenoson could induce the same level of hyperemia. METHODS: 228 patients with dynamic CZT-SPECT MPI were retrospectively analyzed (66 patients stressed with regadenoson and 162 with dipyridamole) in terms of MBF and MFR. To rule out confounding factors, two groups of 41 patients were matched for clinical characteristics in a sub-analysis, excluding high cardiovascular risk patients. RESULTS: Overall stress MBF was higher in regadenoson patients (1.71 ± 0.73 vs. 1.44 ± 0.55 mL·min-1·g-1 for regadenoson and dipyridamole, respectively, p < .05). However, when confounding factors were ruled out, stress MBF (1.57 ± 0.56 vs. 1.61 ± 0.62 mL·min-1·g-1 for dipyridamole and regadenoson, respectively, p = .88) and MFR (2.62 ± 0.77 vs. 2.46 ± 0.76 for dipyridamole and regadenoson, respectively, p = .40) were not different between regadenoson and dipyridamole. CONCLUSIONS: Our results suggest that dipyridamole and regadenoson induce equivalent hyperemia in dynamic SPECT with similar stress MBF and MFR in comparable patients.


Assuntos
Hiperemia , Imagem de Perfusão do Miocárdio , Circulação Coronária , Dipiridamol/farmacologia , Humanos , Hiperemia/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Purinas , Pirazóis , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
12.
Front Med (Lausanne) ; 8: 691893, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34150820

RESUMO

Purpose: The aim of this study was to assess the results of cadmium zinc telluride (CZT)- single-photon emission computed tomography (SPECT) myocardial flow reserve (MFR) in coronary artery disease (CAD) screening regarding clinical risk and its correlation to invasive coronary angiography (ICA). Methods: A total of 137 patients (61 male and 76 female) referred for CAD screening myocardial perfusion imaging (MPI) between November 2018 and April 2020 were included in the CFR-OR prospective trial. The 10-year risk of cardiovascular death according to the European Society of Cardiology (SCORE) was calculated. SPECT 1-day 99mTc-tetrofosmin protocol was acquired on CZT cardiac-dedicated pinhole cameras. Low-dose thoracic CT was used for coronary calcium score (CCS) evaluation. ICA, when performed within 3 months, was also analyzed. Results: Mean SCORE and mean global MFR were, respectively, 4 ± 3.1% and 2.50 ± 0.74; 34 patients had impaired CFR (using a threshold of 2). There was a significant inverse correlation between MFR and SCORE (p = 0.006), gender (p = 0.019), and number of cardiovascular risk factors (p = 0.01). MFR was significantly reduced in patients with CCS above 1 (p = 0.01). No significant correlation was found between MFR and individual cardiovascular risk factors (dyslipidemia, hypertension, diabetes, or family history of CAD). A total of 23 patients underwent ICA. Global MFR SPECT sensitivity and specificity were 83.3 and 100 %, respectively, with an area under the curve of 0.94. Conclusion: Adding MFR to SPECT MPI for CAD screening on CZT camera may contribute to high-risk patient identification and enhance diagnostic performances. MFR could help physician decision to perform ICA.

13.
J Nucl Cardiol ; 28(6): 2560-2568, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32080802

RESUMO

OBJECTIVES: Most of cardiac dedicated CZT-SPECT systems are not equipped with CT, whereas PET systems are. We evaluated the impact of AC correction on CZT-SPECT myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements. METHODS: 104 patients were included. SPECT data were acquired on cadmium zinc telluride (CZT)-based pinhole cardiac camera in listmode using a stress (250 ± 17 MBq)/rest (511 ± 23 MBq) 1-day Tc-99m-tetrofosmin protocol. Low-dose CT was acquired on another SPECT/CT camera in the same position. All analysis was performed using Corridor4DM. RESULTS: Stress and rest MBF were significantly lower when AC was applied (P < 0.001). For regional and global MFR, there was no significant difference between AC and NAC measurements (P > 0.25 at least). Mean global LV MFR was 2.43 ± 0.87 and 2.33 ± 0.89, respectively, for NAC and AC measurements. Using a threshold of 2, 86 patients (83%) remained classified as normal and abnormal regarding global LV MFR whether AC was applied or not. Mean difference between NAC and AC values for the 18 other patients was 0.3. CONCLUSION: AC correction does not significantly affect MFR measurement both in regional and global LV analyses.


Assuntos
Cádmio , Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
14.
Front Med (Lausanne) ; 7: 235, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32626716

RESUMO

Aim: Dopamine transporter (DAT) imaging with [123I] FP-CIT (DaTSCAN) is an established diagnostic tool in parkinsonism and dementia. Using a low energy high resolution and sensitivity (LEHRS) collimator and step and shoot continuous scanning mode, Swiftscan single photon emission computed tomography (SPECT) (GE Healthcare) enhances sensitivity and enables time or dose reduction. In this phantom and clinical study, we aim to validate a 25% reduction of the acquisition time using Swiftscan and its lack of effect on visual or quantitative analysis. Methods: Anthropomorphic striatal phantom with fillable striata was used. SPECT data from 30 normals (12 men, 18 women; age range, 39-91 years; mean, 71 years ± 11) and 30 patients with Parkinson disease or other neurodegenerative disease with extra-pyramidal syndrome (16 men, 14 women; age range, 43-84 years; mean, 69 years ± 10) were also included. Both phantom and clinical data were acquired using Swiftscan and reconstructed with full-time and 25%-time reduction. Striatal binding ratios (SBRs) were calculated using DaTQUANT software. Results: Both in phantom experiments and in clinical cases, visual analysis remained stable and SBRs were not significantly different whether using Swiftscan or Swiftscan with 25%-time reduction (p < 0.001). There was an excellent inter-rater agreement and no effect of time reduction on diagnosis or on image quality. Conclusion: Using Swiftscan step and shoot continuous SPECT mode, 25%-time reduction can be applied to DaTSCAN acquisition protocols, without impairing visual or quantitative analysis.

16.
Clin Nucl Med ; 44(11): e617-e619, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31306190

RESUMO

Dedicated cadmium-zinc-telluride cardiac cameras have been shown to provide accurate measurements of absolute myocardial blood flow and flow reserve when PET is not available. We report the case of a 66-year-old woman who underwent 1-day stress/rest myocardial perfusion imaging (MPI) for coronary artery disease (CAD) screening. Relative MPI analysis was normal, whereas low-dose CT showed high calcium score. Myocardial blood flow and flow reserve were strongly impaired in all territories. Coronary angiography confirmed extended CAD. Flow parameters derived from cadmium-zinc-telluride SPECT MPI acquisition and calcium scoring can improve diagnostic accuracy and confidence of CAD.


Assuntos
Cádmio , Cálcio/metabolismo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Imagem de Perfusão do Miocárdio , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/metabolismo , Feminino , Humanos
17.
Clin Nucl Med ; 44(6): 472-474, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30985432

RESUMO

Tomographic radionuclide angiography (TRNA) can monitor cardiac function in patients receiving cardiotoxic chemotherapy. Gamma cameras using CZT detectors enable dose reduction and quicker acquisitions. We report 80 patients who underwent a 7-minute TRNA acquisition after injection of 550-MBq Tc-labeled human serum albumin. Data were analyzed full and half. Image quality was not visually decreased. There was no significant difference in left ventricular systolic and diastolic volumes and in left and right ventricular ejection fractions between full and half data acquisitions (P < 0.0001). When injecting half activity, effective dose could be reduced to 1.92 mSv.


Assuntos
Câmaras gama/normas , Imagem do Acúmulo Cardíaco de Comporta/métodos , Antineoplásicos/efeitos adversos , Antineoplásicos/uso terapêutico , Cardiotoxicidade , Imagem do Acúmulo Cardíaco de Comporta/instrumentação , Humanos , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m
20.
Clin Nucl Med ; 39(6): 567-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24806607

RESUMO

We report a case of late omental infarction visualized by F-FDG PET/CT during follow-up for pancreatic adenocarcinoma. The 65-year-old patient was referred for imaging 8 months after pancreaticoduodenectomy and 2 months after completion of a course of chemotherapy. PET/CT showed an FDG-avid omental lesion that suggested peritoneal carcinomatosis. The appearance and evolution at follow-up studies confirmed the diagnosis of omental infarction, a rare complication of pancreatic surgery. This case revealed the possibility of late FDG uptake in omental infarction.


Assuntos
Fluordesoxiglucose F18 , Infarto/induzido quimicamente , Infarto/diagnóstico por imagem , Omento/irrigação sanguínea , Neoplasias Pancreáticas/tratamento farmacológico , Tomografia por Emissão de Pósitrons , Idoso , Humanos , Masculino , Omento/diagnóstico por imagem , Omento/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreaticoduodenectomia , Tomografia Computadorizada por Raios X , Neoplasias Pancreáticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...