1.
Sci Rep ; 12(1): 22534, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581644

RESUMO

We have measured the changes in the production of volatile organic compounds (VOCs) by the oral pathogen Porphyromonas gingivalis, when treated in vitro with the antibiotic amoxicillin. We have also measured the VOC production of P. gingivalis grown in the presence and absence of supplemental hemin. Planktonic bacterial cultures were treated with different amounts of amoxicillin in the lag phase of the bacterial growth. Planktonic bacteria were also cultured with and without supplemental hemin in the culture medium. Concentrations of VOCs were measured with proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) and further molecular identification was done with gas chromatography-mass spectrometry (GC-MS) using solid phase microextraction (SPME) for sampling. The cell growth of P. gingivalis in the cultures was estimated with optical density measurements at the wavelength of 600 nm (OD600). We found that the production of methanethiol, hydrogen sulfide and several short- to medium-chain fatty acids was decreased with antibiotic treatment using amoxicillin. Compounds found to increase with the antibiotic treatment were butyric acid and indole. In cultures without supplemental hemin, indole and short- to medium-chain fatty acid production was significantly reduced. Acetic acid production was found to increase when supplemental hemin was not available. Our results suggest that the metabolic effects of both antibiotic treatment and supplemental hemin availability are reflected in the VOCs produced by P. gingivalis and could be used as markers for bacterial cell growth and response to threat. Analysis of these volatiles from human samples, such as the exhaled breath, could be used in the future to rapidly monitor response to antibacterial treatment.


Assuntos
Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Antibacterianos/farmacologia , Bactérias/metabolismo , Amoxicilina/farmacologia , Ácidos Graxos , Ácido Butírico , Indóis
2.
J Breath Res ; 16(4)2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-36055216

RESUMO

We have measured the composition of volatile organic compounds (VOCs) in the morning breath of 30 healthy individuals before and after tooth brushing. The concentrations of VOCs in the breath samples were measured with proton-transfer-reaction time-of-flight mass spectrometry (MS) and further identification was performed with a combination of solid phase microextraction and offline gas chromatography-MS. We hypothesize that compounds, whose concentrations significantly decreased in the breath after tooth brushing are largely of microbial origin. In this study, we found 35 such VOCs. Out of these, 33 have been previously connected to different oral niches, such as salivary and subgingival bacteria. We also compared the concentrations of the 35 VOCs found in increased amounts in the morning breath to their respective odor thresholds to evaluate their ability to cause odor. Compounds that could contribute to the breath odor include many volatile sulfur compounds, such as methanethiol, hydrogen sulfide, dimethyl sulfide, and 2-methyl-1-propanethiol, but also other VOCs, such as acetic acid, butyric acid, valeric acid, acetaldehyde, octanal, phenol, indole, ammonia, isoprene, and methyl methacrylate.


Assuntos
Sulfeto de Hidrogênio , Compostos Orgânicos Voláteis , Acetaldeído , Amônia , Testes Respiratórios/métodos , Ácido Butírico , Humanos , Indóis , Metacrilatos , Fenóis , Prótons , Compostos Orgânicos Voláteis/análise
3.
Sci Rep ; 11(1): 16897, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34413397

RESUMO

We have measured the volatile fingerprints of four pathogenic oral bacteria connected to periodontal disease and dental abscess: Porphyromonas gingivalis (three separate strains), Prevotella intermedia, Prevotella nigrescens and Tannerella forsythia. Volatile fingerprints were measured in vitro from the headspace gas of the bacteria cultured on agar. Concrete identification of new and previously reported bacterial volatiles were performed by a combination of solid phase microextraction (SPME) and offline gas chromatography-mass spectrometry (GC-MS). We also studied the effect of the reduced electric field strength (E/N) on the fragmentation patterns of bacterial volatiles in online proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS). We aimed to discover possible new biomarkers for the studied oral bacteria, as well as to validate the combination of GC-MS and PTR-MS for volatile analysis. Some of the most promising compounds produced include: 1-Methyl-1,2,3,4-tetrahydroisoquinoline (1MeTIQ), indole, and a cascade of sulphur compounds, such as methanethiol, dimethyl disulphide (DMDS) and dimethyl trisulphide (DMTS). We also found that several compounds, especially alcohols, aldehydes and esters, fragment significantly with the PTR-MS method, when high E/N values are used. We conclude that the studied oral bacteria can be separated by their volatile fingerprints in vitro, which could have importance in clinical and laboratory environments. In addition, using softer ionization conditions can improve the performance of the PTR-MS method in the volatile analysis of certain compounds.


Assuntos
Bactérias/química , Biomarcadores/análise , Cromatografia Gasosa-Espectrometria de Massas , Boca/microbiologia , Prótons , Compostos Orgânicos Voláteis/análise
5.
Anal Chem ; 92(21): 14582-14588, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33081464

RESUMO

Cantilever-enhanced photoacoustic spectroscopy coupled with gas chromatography is used to quantitatively analyze a mixture of alcohols in a quasi-online manner. A full identification and quantification of all analytes are achieved based on their spectral fingerprints using a widely tunable continuous-wave laser as a light source. This can be done even in the case of interfering column/septum bleed or simultaneously eluted peaks. The combination of photoacoustic spectroscopy and gas chromatography offers a viable solution for compact and portable instruments in applications that require straightforward analyses with no consumables.

6.
Alcohol Alcohol ; 55(6): 660-666, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-32808029

RESUMO

AIMS: Alcohol-related hangover symptoms: nausea, headache, stress and anxiety cause globally considerable amount of health problems and economic losses. Many of these harmful effects are produced by alcohol and its metabolite, acetaldehyde, which also is a common ingredient in alcohol beverages. The aim of the present study is to investigate the effect of the amino acid L-cysteine on the alcohol/acetaldehyde related aftereffects. METHODS: Voluntary healthy participants were recruited through advertisements. Volunteers had to have experience of hangover and/or headache. The hangover study was randomized, double-blind and placebo-controlled. Nineteen males randomly swallowed placebo and L-cysteine tablets. The alcohol dose was 1.5 g/kg, which was consumed during 3 h. RESULTS: The primary results based on correlational analysis showed that L-cysteine prevents or alleviates hangover, nausea, headache, stress and anxiety. For hangover, nausea and headache the results were apparent with the L-cysteine dose of 1200 mg and for stress and anxiety already with the dose of 600 mg. CONCLUSIONS: L-cysteine would reduce the need of drinking the next day with no or less hangover symptoms: nausea, headache, stress and anxiety. Altogether, these effects of L-cysteine are unique and seem to have a future in preventing or alleviating these harmful symptoms as well as reducing the risk of alcohol addiction.


Assuntos
Intoxicação Alcoólica/tratamento farmacológico , Ansiedade/tratamento farmacológico , Cisteína/administração & dosagem , Cefaleia/tratamento farmacológico , Náusea/tratamento farmacológico , Vitaminas/administração & dosagem , Adulto , Intoxicação Alcoólica/complicações , Intoxicação Alcoólica/diagnóstico , Ansiedade/diagnóstico , Ansiedade/etiologia , Suplementos Nutricionais , Método Duplo-Cego , Cefaleia/diagnóstico , Cefaleia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Náusea/diagnóstico , Náusea/etiologia , Adulto Jovem
8.
Head Neck ; 42(4): 787-793, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31854494

RESUMO

Head and neck cancer (HNC) comprises a heterogeneous group of upper aerodigestive tract malignant neoplasms, the most frequent of which is squamous cell carcinoma. HNC forms the eighth most common cancer type and the incidence is increasing. However, survival has improved only moderately during the past decades. Currently, early diagnosis remains the mainstay for improving treatment outcomes in this patient population. Unfortunately, screening methods to allow early detection of HNC are not yet established. Therefore, many cases are still diagnosed at advanced stage, compromising outcomes. Exhaled breath analysis (EBA) is a diagnostic tool that has been recently introduced for many cancers. Breath analysis is non-invasive, cost-effective, time-saving, and can potentially be applied for cancer screening. Here, we provide a summary of the accumulated evidence on the feasibility of EBA in the diagnosis of HNC.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Testes Respiratórios , Carcinoma de Células Escamosas/diagnóstico , Detecção Precoce de Câncer , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Programas de Rastreamento
9.
J Breath Res ; 14(1): 016010, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31698353

RESUMO

Infections by oral pathogens are one of the most common health problems worldwide. Due to the intimate connection between exhaled breath and the oral cavity, breath analysis could potentially be used to diagnose these infections. However, little is known about the volatile emissions of important oral pathogens that are connected with gingivitis and periodontitis. In this study, we have performed in vitro headspace measurements on four important oral pathogens (P. gingivalis, T. forsythia, P. intermedia and P. nigrescens) using proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS). Some of the most abundant compounds produced by the bacteria include hydrogen sulphide, methanethiol, acetone, dimethylsulphide, isoprene, cyclopentanone and indole as tentatively assigned from the mass spectra. Several other abundant mass signals were recorded but the assignment of these is less certain. Some of the bacterial species can be separated from each other by the emitted volatile fingerprints. The results of this study can be used in potential development of a diagnostic breath test for oral infections. In addition, as several of the measured compounds are known to be toxic, the results point to an intriguing possibility of studying the connection between the bacterial virulence and the emitted volatile compounds.


Assuntos
Bactérias/metabolismo , Boca/microbiologia , Sistemas On-Line , Compostos Orgânicos Voláteis/análise , Automação , Bactérias Anaeróbias/metabolismo , Biomarcadores/análise , Testes Respiratórios , Humanos , Espectrometria de Massas , Padrões de Referência
10.
Opt Lett ; 44(5): 1142-1145, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30821733

RESUMO

We report a photoacoustic spectroscopy setup with a high-power mid-infrared frequency comb as the light source. The setup is used in broadband spectroscopy of radiocarbon methane. Owing to the high sensitivity of a cantilever-enhanced photoacoustic cell and the high-power light source, we can reach a detection limit below 100 ppb in a broadband measurement with a sample volume of only a few milliliters. The first infrared spectrum of CH414 is reported and given a preliminary assignment. The results lay a foundation for the development of optical detection systems for radiocarbon methane.

11.
Opt Express ; 26(22): 29086-29098, 2018 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-30470075

RESUMO

A method of measuring double resonant two-photon signal and background from a single cavity ring-down decay is introduced. This is achieved by modulating the double resonance loss via one of the light sources exciting the transition. The noise performance of the method is characterized theoretically and experimentally. The addition of a new parameter to the fitting function introduces a minor noise increase due to parameter correlation. However, the concurrent recording of the background can extend the stable measurement time. Alternatively, the method allows a faster measurement speed, while still recording the background, which is often advantageous in double resonance measurements. Finally, the method is insensitive to changes in the cavity decay rate at short timescales and can lead to improved performance if they have significant contribution to the final noise level compared to the detector noise.

12.
Scand J Clin Lab Invest ; 78(1-2): 153-156, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29304558

RESUMO

Fractional exhaled nitric oxide (FENO) assesses eosinophilic inflammation of the airways, but FENO values are also influenced by oral nitric oxide (NO). The aim of this pilot study was to measure FENO and compare the effect of two different mouthwashes on FENO and analyse the duration of the effect. FENO was measured in 12 randomized volunteers (healthy or asthmatic subjects) with a NIOX VERO® analyser at an expiratory flow rate of 50 mL/s. After a baseline measurement, a mouthwash was performed either with tap water or carbonated water and was measured during 20 min in 2 min intervals. The procedure was repeated with the other mouthwash. We found that both mouthwashes reduced FENO immediately at the beginning compared to the baseline (p < .001). The carbonated water mouthwash effect lasted 12 min (p ranging from <0.001 to <0.05). The tap water mouthwash reduced FENO statistically significantly only for 2 min compared with the baseline. We conclude that a single carbonated water mouthwash can significantly reduce the oropharyngeal NO contribution during a 12 min time interval.


Assuntos
Água Carbonatada/análise , Expiração , Antissépticos Bucais/análise , Óxido Nítrico/análise , Abastecimento de Água , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
Appl Phys B ; 124(8): 161, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30956412

RESUMO

Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays. This review presents an update of the current status of optical methods, using near and mid-infrared sources, for clinical breath gas analysis over the last decade and describes recent technological developments and their applications. The review includes: tunable diode laser absorption spectroscopy, cavity ring-down spectroscopy, integrated cavity output spectroscopy, cavity-enhanced absorption spectroscopy, photoacoustic spectroscopy, quartz-enhanced photoacoustic spectroscopy, and optical frequency comb spectroscopy. A SWOT analysis (strengths, weaknesses, opportunities, and threats) is presented that describes the laser-based techniques within the clinical framework of breath research and their appealing features for clinical use.

14.
Opt Express ; 25(5): 4688-4699, 2017 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-28380740

RESUMO

We report a setup for high-resolution two-photon spectroscopy using a mid-infrared continuous wave optical parametric oscillator (CW-OPO) and a near-infrared diode laser as the excitation sources, both of which are locked to fully stabilized optical frequency combs. The diode laser is directly locked to a commercial near-infrared optical frequency comb using an optical phase-locked loop. The near-infrared frequency comb is also used to synchronously pump a degenerate femtosecond optical parametric oscillator to produce a fully stabilized mid-infrared frequency comb. The beat frequency between the mid-infrared comb and the CW-OPO is then stabilized through frequency locking. We used the setup to measure a double resonant two-photon transition to a symmetric vibrational state of acetylene with a sub-Doppler resolution and high signal-to-noise ratio.

15.
Sci Rep ; 6: 22577, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26940198

RESUMO

Hydrogen cyanide (HCN) has been recognized as a potential biomarker for non-invasive diagnosis of Pseudomonas aeruginosa infection in the lung. However, the oral cavity is a dominant production site for exhaled HCN and this contribution can mask the HCN generated in the lung. It is thus important to understand the sources of HCN production in the oral cavity. By screening of oral anaerobes for HCN production, we observed that the genus of Porphyromonas, Prevotella and Fusobacterium generated low levels of HCN in vitro. This is the first study to show that oral anaerobes are capable of producing HCN in vitro. Further investigations were conducted on the species of P. gingivalis and we successfully detected HCN production (0.9-10.9 ppb) in the headspace of three P. gingivalis reference strains (ATCC 33277, W50 and OMG 434) and one clinical isolate. From P. gingivalis ATCC 33277 and W50, a strong correlation between HCN and CO2 concentrations (rs = 0.89, p < 0.001) was observed, indicating that the HCN production of P. gingivalis might be connected with the bacterial metabolic activity. These results indicate that our setup could be widely applied to the screening of in vitro HCN production by both aerobic and anaerobic bacteria.


Assuntos
Infecções por Bacteroidaceae/diagnóstico , Cianeto de Hidrogênio/análise , Porphyromonas gingivalis/fisiologia , Infecções por Pseudomonas/diagnóstico , Pseudomonas aeruginosa/fisiologia , Testes Respiratórios , Diagnóstico Diferencial , Expiração , Humanos , Pulmão/microbiologia , Boca/microbiologia , Análise Espectral
16.
J Chem Phys ; 139(5): 054201, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-23927255

RESUMO

We present a sensitive experimental method for molecular spectroscopy that can be used to determine ro-vibrational states using mid-infrared stimulated emission. Our infrared stimulated emission probing (IRSEP) experiment is based on using a narrow-line, continuous-wave Ti:sapphire laser beam (pump) to excite the molecules to an upper vibrational state and a continuous-wave, mid-infrared beam from an optical parametric oscillator (probe) to detect the stimulated emission by the excited molecules. Spectroscopic data are gathered by tuning the wavelengths of the beams. The molecules are probed before their velocity distribution is disturbed by collisions, which leads to a sub-Doppler resolution. The full width at half maximum of the emission peaks is below 10 MHz. The stimulated emission lines are measured with an accuracy of at least 0.005 cm(-1). We use the IRSEP experiment to observe and analyze the symmetric ro-vibrational state [21+] (3ν1(Σg)) of acetylene (C2H2). This state is not accessible via one photon transitions from the ground vibrational state. We use the least-squares method to determine that the band center is at 9991.9725 (12) cm(-1) and the rotational parameters are B = 1.156145 (22) and D = 1.608 (87) × 10(-6) cm(-1), where the uncertainties in parentheses are one-standard errors in the least significant digit.

17.
Opt Express ; 21(8): 10240-50, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23609733

RESUMO

Highly sensitive cantilever-enhanced photoacoustic detection of hydrogen cyanide and methane in the mid-infrared region is demonstrated. A mid-infrared continuous-wave frequency tunable optical parametric oscillator was used as a light source in the experimental setup. Noise equivalent detection limits of 190 ppt (1 s) and 65 ppt (30 s) were achieved for HCN and CH(4), respectively. The normalized noise equivalent absorption coefficient is 1.8 × 10(-9) W cm(-1) Hz(-1/2).


Assuntos
Gases/análise , Sistemas Microeletromecânicos/instrumentação , Microquímica/instrumentação , Oscilometria/instrumentação , Técnicas Fotoacústicas/instrumentação , Espectrofotometria Infravermelho/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Gases/química
18.
Biomarkers ; 14(5): 285-91, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19480566

RESUMO

Hydrogen cyanide (HCN) in breath has been suggested as a diagnostic tool for cyanide poisoning and for cyanide-producing bacterial infections. To distinguish elevated levels of breath HCN, baseline data are needed. Background levels of HCN were measured in mixed exhaled air from 40 healthy subjects (26 men, 14 women, age 21-61 years; detection limit: 1.5 ppb; median: 4.4 ppb; range <1.5-14 ppb) by near-infrared cavity ring down spectroscopy (CRDS). No correlation was observed with smoking habits, recent meals or age. However, female subjects had slightly higher breath levels of HCN than male subjects. CRDS has not previously been used for this purpose.


Assuntos
Testes Respiratórios/métodos , Cianeto de Hidrogênio/análise , Espectrofotometria Infravermelho/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Caracteres Sexuais
19.
J Chem Phys ; 127(22): 221102, 2007 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-18081379

RESUMO

We present a combined experimental and theoretical study on the radiative lifetime of CO in the a (3)Pi(1,2), v=0 state. CO molecules in a beam are prepared in selected rotational levels of this metastable state, Stark-decelerated, and electrostatically trapped. From the phosphorescence decay in the trap, the radiative lifetime is measured to be 2.63+/-0.03 ms for the a (3)Pi(1), v=0, J=1 level. From the spin-orbit coupling between the a (3)Pi and the A (1)Pi states a 20% longer radiative lifetime of 3.16 ms is calculated for this level. It is concluded that coupling to other (1)Pi states contributes to the observed phosphorescence rate of metastable CO.