1.
IEEE Trans Med Imaging ; 33(5): 1023-34, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24770908

RESUMO

2D/3D registration of patient vasculature from preinterventional computed tomography angiography (CTA) to interventional X-ray angiography is of interest to improve guidance in percutaneous coronary interventions. In this paper we present a novel feature based 2D/3D registration framework, that is based on probabilistic point correspondences, and show its usefulness on aligning 3D coronary artery centerlines derived from CTA images with their 2D projection derived from interventional X-ray angiography. The registration framework is an extension of the Gaussian mixture model (GMM) based point-set registration to the 2D/3D setting, with a modified distance metric. We also propose a way to incorporate orientation in the registration, and show its added value for artery registration on patient datasets as well as in simulation experiments. The oriented GMM registration achieved a median accuracy of 1.06 mm, with a convergence rate of 81% for nonrigid vessel centerline registration on 12 patient datasets, using a statistical shape model. The method thereby outperformed the iterative closest point algorithm, the GMM registration without orientation, and two recently published methods on 2D/3D coronary artery registration.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional/métodos , Distribuição Normal , Algoritmos , Humanos , Intervenção Coronária Percutânea , Cirurgia Assistida por Computador
2.
Med Image Anal ; 17(8): 859-76, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23837963

RESUMO

Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/.


Assuntos
Algoritmos , Angiografia Coronária/normas , Estenose Coronária/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Países Baixos , Intensificação de Imagem Radiográfica/métodos , Intensificação de Imagem Radiográfica/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Med Image Anal ; 17(6): 698-709, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23628692

RESUMO

Accurate alignment of intra-operative X-ray coronary angiography (XA) and pre-operative cardiac CT angiography (CTA) may improve procedural success rates of minimally invasive coronary interventions for patients with chronic total occlusions. It was previously shown that incorporating patient specific coronary motion extracted from 4D CTA increases the robustness of the alignment. However, pre-operative CTA is often acquired with gating at end-diastole, in which case patient specific motion is not available. For such cases, we investigate the possibility of using population based coronary motion models to provide constraints for the 2D+t/3D registration. We propose a methodology for building statistical motion models of the coronary arteries from a training population of 4D CTA datasets. We compare the 2D+t/3D registration performance of the proposed statistical models with other motion estimates, including the patient specific motion extracted from 4D CTA, the mean motion of a population, the predicted motion based on the cardiac shape. The coronary motion models, constructed on a training set of 150 patients, had a generalization accuracy of 1mm root mean square point-to-point distance. Their 2D+t/3D registration accuracy on one cardiac cycle of 12 monoplane XA sequences was similar to, if not better than, the 4D CTA based motion, irrespective of which respiratory model and which feature based 2D/3D distance metric was used. The resulting model based coronary motion estimate showed good applicability for registration of a subsequent cardiac cycle.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Modelos Estatísticos , Tomografia Computadorizada por Raios X/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Simulação por Computador , Humanos , Aumento da Imagem/métodos , Movimento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Med Image Anal ; 17(5): 515-24, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23602917

RESUMO

The distensibility of a blood vessel is a marker of atherosclerotic disease. In this paper we investigate the feasibility of measuring carotid artery distensibility on 4D CTA, both manually and using a new automatic method. On 4D CTA datasets manual (n=38) and automatic (n=76) measurements of the carotid distensibility were performed. A subset (n=10) of the manual annotations were repeated by a second observer. The interobserver variability was assessed using a Bland-Altman analysis and appeared to be too large to reliably measure the distensibility using manual annotation. We compared two versions of the automatic method: one using 3D registration and one using a 4D registration method. The latter resulted in a more smooth deformation over time. The automatic method was evaluated using a synthetic deformation and by investigating whether known relations with cardiovascular risk factors could be reproduced. The relation between distensibility and cardiovascular risk factors was tested with a Mann-Whitney U test. Automatic measurements revealed an association with hypertension whereas the manual measurements did not. This relation has been found by other studies too. We conclude that carotid artery distensibility measurements should be performed automatically and that the method described in this paper is suitable for that. All CTA datasets and related clinical data used in this study can be downloaded from our website (http://ctadist.bigr.nl).


Assuntos
Angiografia/métodos , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/fisiopatologia , Tomografia Computadorizada Quadridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnica de Subtração , Idoso , Módulo de Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência Vascular
5.
Comput Med Imaging Graph ; 36(3): 215-26, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22284861

RESUMO

In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the coronary arteries are proposed and evaluated. The method relies on motion-vector fields derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Hereto, start and end points are provided by the user in one time-frame only. Using an elastic image registration, these points are propagated to all the remaining cardiac phases. Consequently, a multi-phase three-dimensional coronary centerline is determined by applying a semi-automatic minimum cost path based extraction method. Corresponding centerline positions are used to determine the relative motion-vector fields from phase to phase. Finally, dense motion-vector fields are achieved by thin-plate-spline interpolation and used to perform a motion-corrected iterative reconstruction of a selected region of interest. The performance of the method is validated on five patients, showing the improved sharpness of cardiac motion-corrected gated iterative reconstructions compared to the results achieved by a classical gated iterative method. The results are also compared to known manual and fully automatic coronary artery motion estimation methods.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Vasos Coronários/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Movimento/fisiologia , Algoritmos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Humanos , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
Int J Comput Assist Radiol Surg ; 7(4): 557-71, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21948075

RESUMO

PURPOSE: In clinical practice, both coronary anatomy and myocardial perfusion information are needed to assess coronary artery disease (CAD). The extent and severity of coronary stenoses can be determined using computed tomography coronary angiography (CTCA); the presence and amount of ischemia can be identified using myocardial perfusion imaging, such as perfusion magnetic resonance imaging (PMR). To determine which specific stenosis is associated with which ischemic region, experts use assumptions on coronary perfusion territories. Due to the high variability between patient's coronary artery anatomies, as well as the uncertain relation between perfusion territories and supplying coronary arteries, patient-specific systems are needed. MATERIAL AND METHODS: We present a patient-specific visualization system, called Synchronized Multimodal heART Visualization (SMARTVis), for relating coronary stenoses and perfusion deficits derived from CTCA and PMR, respectively. The system consists of the following comprehensive components: (1) two or three-dimensional fusion of anatomical and functional information, (2) automatic detection and ranking of coronary stenoses, (3) estimation of patient-specific coronary perfusion territories. RESULTS: The potential benefits of the SMARTVis tool in assessing CAD were investigated through a case-study evaluation (conventional vs. SMARTVis tool): two experts analyzed four cases of patients with suspected multivessel coronary artery disease. When using the SMARTVis tool, a more reliable estimation of the relation between perfusion deficits and stenoses led to a more accurate diagnosis, as well as a better interobserver diagnosis agreement. CONCLUSION: The SMARTVis comprehensive visualization system can be effectively used to assess disease status in multivessel CAD patients, offering valuable new options for the diagnosis and management of these patients.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Gadolínio DTPA , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade
7.
Med Image Anal ; 15(4): 477-88, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21419689

RESUMO

This paper describes an evaluation framework that allows a standardized and objective quantitative comparison of carotid artery lumen segmentation and stenosis grading algorithms. We describe the data repository comprising 56 multi-center, multi-vendor CTA datasets, their acquisition, the creation of the reference standard and the evaluation measures. This framework has been introduced at the MICCAI 2009 workshop 3D Segmentation in the Clinic: A Grand Challenge III, and we compare the results of eight teams that participated. These results show that automated segmentation of the vessel lumen is possible with a precision that is comparable to manual annotation. The framework is open for new submissions through the website http://cls2009.bigr.nl.


Assuntos
Angiografia/métodos , Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Med Image Anal ; 15(2): 238-49, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21075672

RESUMO

A registration method for motion estimation in dynamic medical imaging data is proposed. Registration is performed directly on the dynamic image, thus avoiding a bias towards a specifically chosen reference time point. Both spatial and temporal smoothness of the transformations are taken into account. Optionally, cyclic motion can be imposed, which can be useful for visualization (viewing the segmentation sequentially) or model building purposes. The method is based on a 3D (2D+time) or 4D (3D+time) free-form B-spline deformation model, a similarity metric that minimizes the intensity variances over time and constrained optimization using a stochastic gradient descent method with adaptive step size estimation. The method was quantitatively compared with existing registration techniques on synthetic data and 3D+t computed tomography data of the lungs. This showed subvoxel accuracy while delivering smooth transformations, and high consistency of the registration results. Furthermore, the accuracy of semi-automatic derivation of left ventricular volume curves from 3D+t computed tomography angiography data of the heart was evaluated. On average, the deviation from the curves derived from the manual annotations was approximately 3%. The potential of the method for other imaging modalities was shown on 2D+t ultrasound and 2D+t magnetic resonance images. The software is publicly available as an extension to the registration package elastix.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Inteligência Artificial , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Med Phys ; 36(12): 5568-79, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20095269

RESUMO

PURPOSE: The application and large-scale evaluation of minimum cost path approaches for coronary centerline extraction from computed tomography coronary angiography (CTCA) data and the development and evaluation of a novel method to reduce the user-interaction time. METHODS: A semiautomatic method based on a minimum cost path approach is evaluated for two different cost functions. The first cost function is based on a frequently used vesselness measure and intensity information, and the second is a recently proposed cost function based on region statistics. User interaction is minimized to one or two mouse clicks distally in the coronary artery. The starting point for the minimum cost path search is automatically determined using a newly developed method that finds a point in the center of the aorta in one of the axial slices. This step ensures that all computationally expensive parts of the algorithm can be precomputed. RESULTS: The performance of the aorta localization procedure was demonstrated by a success rate of 100% in 75 images. The success rate and accuracy of centerline extraction was quantitatively evaluated on 48 coronary arteries in 12 images by comparing extracted centerlines with a manually annotated reference standard. The method was able to extract 88% and 47% of the vessel center-lines correctly using the vesselness/intensity and region statistics cost function, respectively. For only the proximal part of the vessels these values were 97% and 86%, respectively. Accuracy of centerline extraction, defined as the average distance from correctly automatically extracted parts of the centerline to the reference standard, was 0.64 mm for the vesselness/intensity and 0.51 mm for the region statistics cost function. The interobserver variability was 99% for the success rate measure and 0.42 mm for the accuracy measure. Qualitative evaluation using the best performing cost function resulted in successful centerline extraction for 233 out of the 252 coronaries (92%) in 63 additional CTCA images. CONCLUSIONS: The presented results, in combination with minimal user interaction and low computation time, show that minimum cost path approaches can effectively be applied as a preprocessing step for subsequent analysis in clinical practice and biomedical research.


Assuntos
Angiografia Coronária/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Fatores de Tempo , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS