Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Heart Valve Dis ; 18(1): 106-10, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19301561

RESUMO

BACKGROUND AND AIM OF THE STUDY: Annuloplasty sizing with standard valve sizers may be imprecise and difficult in minimally invasive procedures. It is hypothesized that a constant clinical conversion factor relates the echocardiographic aortic annulus diameter (AAD) and the intertrigonal distance (ITD) in patients with degenerative mitral regurgitation (MR). This may provide another method to size the annuloplasty ring required for mitral valve repair. METHODS: An observational study of 50 patients with degenerative MR undergoing robotic-assisted surgery was conducted. All patients underwent surgery between September 2005 and November 2007. The AAD at the base of the aortic leaflets was measured using intraoperative two-dimensional transesophageal echocardiography. The ITD was measured independently under direct vision during surgery. The echocardiographic ITD was then determined by dividing the AAD by 0.8, and the value for each patient compared to the corresponding surgical measurement. Agreement was assessed statistically using the Bland-Altman method. RESULTS: The limits of agreement were -3 mm (t = 2.010; 49 df; p = 0.05; 95% CI: -4 to -2 mm) to 3 mm (t = 2.010; 49 df; p = 0.05; 95% CI: 2 to 4 mm). In 86% of cases (43/50), the differences between the two methods was < or = 2 mm. CONCLUSION: In most cases of degenerative mitral valve disease the echocardiographic ITD measurement is clinically acceptable, and may serve as an adjunct to existing methods when sizing the annuloplasty ring required for repair.


Assuntos
Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem
3.
Aust N Z J Obstet Gynaecol ; 44(4): 349-50, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15282010

RESUMO

This prospective observational study aimed to assess the feasibility of adapting peritoneal hyperdistention to 25 mmHg during laparoscopy in an Australian hospital environment. A total of 1150 consecutive diagnostic or operative laparoscopies were performed. All cases were monitored for early detection of untoward physiological changes. All patients had Veress needle insufflation with distension to 25 mmHg prior to insertion of the primary trocar. No patients experienced any surgical entry complications or adverse clinical effects noted during anaesthetic. The aim of the current study is to assess the feasibility and safety of increasing the peritoneal insufflation pressure to 25 mmHg for primary trocar insertion.


Assuntos
Laparoscopia/métodos , Instrumentos Cirúrgicos , Abdome/fisiopatologia , Abdome/cirurgia , Austrália , Humanos , Cuidados Intraoperatórios , Complicações Intraoperatórias , Laparoscopia/efeitos adversos , Monitorização Fisiológica , Pressão , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Anesth Analg ; 98(6): 1521-1527, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15155300

RESUMO

UNLABELLED: Recent investigations have sought to improve intrathecal analgesia by combining opioids with other classes of analgesics. In this study we assessed the ability of intrathecal midazolam to increase the potency and duration of the analgesic effects of intrathecal fentanyl without causing adverse effects. Thirty parturients with cervical dilations 2-6 cm were randomized to receive either intrathecal midazolam 2 mg, fentanyl 10 micro g, or both combined to initiate analgesia. Pain scores were recorded before and at 5-min intervals for 30 min after the injection and then every 30 minutes until the patient requested further analgesia. The presence and severity of nausea, emesis, pruritus, headache, and sedation, in addition to arterial blood pressure, heart rate, respiratory rate, sensory changes to ice, motor impairment, cardiotocograph, and Apgar score were also recorded. The parturients were assessed after 2 days and 1 mo for neurologic impairment. Preinjection pain scores were unaltered by intrathecal midazolam alone and moderately decreased by fentanyl. Intrathecal midazolam increased the analgesic effect of fentanyl. No treatment altered cardiorespiratory variables or caused motor impairment. The addition of intrathecal midazolam to fentanyl did not increase the occurrence of any maternal adverse event or abnormalities on the cardiotocograph. We conclude that intrathecal midazolam enhanced the analgesic effect of fentanyl without increasing maternal or fetal adverse effects. IMPLICATIONS: Treatment of labor pain with epidural injections of local anesthetic is complicated by decreases in arterial blood pressure and leg weakness. This study showed that a mixture of two drugs, fentanyl and midazolam, could provide powerful pain relief when the drugs were given together spinally without such side effects.


Assuntos
Fentanila/administração & dosagem , Trabalho de Parto/efeitos dos fármacos , Midazolam/administração & dosagem , Dor/tratamento farmacológico , Adulto , Análise de Variância , Distribuição de Qui-Quadrado , Quimioterapia Combinada , Feminino , Humanos , Injeções Espinhais , Dor/fisiopatologia , Gravidez , Estatísticas não Paramétricas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...