Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
3.
Circulation ; 143(21): 2049-2060, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-33993718

RESUMO

BACKGROUND: Prenatal detection (PND) has benefits for infants with hypoplastic left heart syndrome (HLHS) and transposition of the great arteries (TGA), but associations between sociodemographic and geographic factors with PND have not been sufficiently explored. This study evaluated whether socioeconomic quartile (SEQ), public insurance, race and ethnicity, rural residence, and distance of residence (distance and driving time from a cardiac surgical center) are associated with the PND or timing of PND, with a secondary aim to analyze differences between the United States and Canada. METHODS: In this retrospective cohort study, fetuses and infants <2 months of age with HLHS or TGA admitted between 2012 and 2016 to participating Fetal Heart Society Research Collaborative institutions in the United States and Canada were included. SEQ, rural residence, and distance of residence were derived using maternal census tract from the maternal address at first visit. Subjects were assigned a SEQ z score using the neighborhood summary score or Canadian Chan index and separated into quartiles. Insurance type and self-reported race and ethnicity were obtained from medical charts. We evaluated associations among SEQ, insurance type, race and ethnicity, rural residence, and distance of residence with PND of HLHS and TGA (aggregate and individually) using bivariate analysis with adjusted associations for confounding variables and cluster analysis for centers. RESULTS: Data on 1862 subjects (HLHS: n=1171, 92% PND; TGA: n=691, 58% PND) were submitted by 21 centers (19 in the United States). In the United States, lower SEQ was associated with lower PND in HLHS and TGA, with the strongest association in the lower SEQ of pregnancies with fetal TGA (quartile 1, 0.78 [95% CI, 0.64-0.85], quartile 2, 0.77 [95% CI, 0.64-0.93], quartile 3, 0.83 [95% CI, 0.69-1.00], quartile 4, reference). Hispanic ethnicity (relative risk, 0.85 [95% CI, 0.72-0.99]) and rural residence (relative risk, 0.78 [95% CI, 0.64-0.95]) were also associated with lower PND in TGA. Lower SEQ was associated with later PND overall; in the United States, rural residence and public insurance were also associated with later PND. CONCLUSIONS: We demonstrate that lower SEQ, Hispanic ethnicity, and rural residence are associated with decreased PND for TGA, with lower SEQ also being associated with decreased PND for HLHS. Future work to increase PND should be considered in these specific populations.


Assuntos
Etnicidade/genética , Síndrome do Coração Esquerdo Hipoplásico/epidemiologia , Grupos Raciais/genética , Transposição dos Grandes Vasos/epidemiologia , Estudos de Coortes , Feminino , Geografia , Humanos , Masculino , Estudos Retrospectivos , Classe Social
4.
J Am Heart Assoc ; 9(21): e016684, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33076749

RESUMO

Background In a recent multicenter study of perinatal outcome in fetuses with Ebstein anomaly or tricuspid valve dysplasia, we found that one third of live-born patients died before hospital discharge. We sought to further describe postnatal management strategies and to define risk factors for neonatal mortality and circulatory outcome at discharge. Methods and Results This 23-center, retrospective study from 2005 to 2011 included 243 fetuses with Ebstein anomaly or tricuspid valve dysplasia. Among live-born patients, clinical and echocardiographic factors were evaluated for association with neonatal mortality and palliated versus biventricular circulation at discharge. Of 176 live-born patients, 7 received comfort care, 11 died <24 hours after birth, and 4 had insufficient data. Among 154 remaining patients, 38 (25%) did not survive to discharge. Nearly half (46%) underwent intervention. Mortality differed by procedure; no deaths occurred in patients who underwent right ventricular exclusion. At discharge, 56% of the cohort had a biventricular circulation (13% following intervention) and 19% were palliated. Lower tricuspid regurgitation jet velocity (odds ratio [OR], 2.3 [1.1-5.0], 95% CI, per m/s; P=0.025) and lack of antegrade flow across the pulmonary valve (OR, 4.5 [1.3-14.2]; P=0.015) were associated with neonatal mortality by multivariable logistic regression. These variables, along with smaller pulmonary valve dimension, were also associated with a palliated outcome. Conclusions Among neonates with Ebstein anomaly or tricuspid valve dysplasia diagnosed in utero, a variety of management strategies were used across centers, with poor outcomes overall. High-risk patients with low tricuspid regurgitation jet velocity and no antegrade pulmonary blood flow should be considered for right ventricular exclusion to optimize their chance of survival.


Assuntos
Anomalia de Ebstein/mortalidade , Valva Tricúspide/anormalidades , Velocidade do Fluxo Sanguíneo/fisiologia , Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/terapia , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/epidemiologia , Mortalidade Hospitalar , Humanos , Recém-Nascido , Modelos Logísticos , Masculino , Mortalidade Perinatal , Diagnóstico Pré-Natal , Estudos Retrospectivos , Fatores de Risco
5.
Echocardiography ; 36(1): 142-149, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30506599

RESUMO

OBJECTIVES: Echocardiography is used to quantitatively characterize cardiovascular function in fetuses with cardiac abnormalities and inform decisions for fetal or perinatal interventions. It is clinically important to understand the reproducibility of these measures, particularly between testers. While studies have reported intra-observer variability and inter-observer variability, little is known about test-retest variability for these measures. We hypothesized that even in a high volume echocardiography laboratory, quantitative measurements will demonstrate higher test-retest variability compared with inter-observer variability and intra-observer variability of the same measurements. METHODS: Prospective study of uncomplicated, singleton pregnancies to evaluate fetal measures of cardiovascular function obtained by echocardiography. One sonographer obtained predefined variables, and then, a second sonographer obtained the same variables 15 minutes after the first sonographer. Separate data acquisitions were obtained by the two sonographers to evaluate test-retest variability. Intra-observer variability and inter-observer variability were also evaluated. RESULTS: Thirty fetuses between 17- and 36-week gestation were enrolled. Time-based variables had the best intra-observer agreement and inter-observer agreement (1.2%-7.4%), while 2D (7.5%-10%), M-mode (4.9%-10.1%), and velocity-time integral (VTI; 2.6%-13.8%) measurements had poorer agreement. For all variables, test-retest agreement was worse (3%-32.1%), particularly for measurement of myocardial performance index (MPI; 19.7%-21.1%), cardiac output estimation (27.2%-27.9%), and VTI-based indices (14.7%-32.1%). CONCLUSIONS: In a laboratory highly experienced in quantitative fetal echocardiography, intra-observer agreement and inter-observer agreement are good for most quantitative parameters. However, test-retest agreement is fair or poor for several variables, notably the MPI, cardiac output estimation, and VTI-based indices. Understanding how these measures vary between separate acquisitions is important for clinical interpretation and decision making.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Estudos de Avaliação como Assunto , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Ann Thorac Surg ; 106(2): 575-580, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29733824

RESUMO

BACKGROUND: The approach (lateral thoracotomy versus median sternotomy) to repair coarctation of the aorta is frequently based on arch dimensions from the preoperative echocardiogram. Few studies have assessed the relationship between preoperative arch dimensions and late postoperative outcome. This study aimed to define how preoperative arch dimensions relate to late outcomes and identify long-term predictors of a successful operation. METHODS: We performed a retrospective review of 102 neonates and infants undergoing isolated coarctation repair by lateral thoracotomy between 2003 and 2012. Long-term surgical success was defined based on the following five factors: corrected arch gradient below 20 mm Hg, blood pressure cuff gradient below 15 mm Hg, systolic blood pressure below the 95th percentile during the clinic visit, no antihypertensive medication use, and freedom from reintervention. Regression analysis was performed to identify factors that would predict the need for reintervention and long-term success. RESULTS: At a median of 6 years of follow-up, long-term success was achieved in 63% (56 of 89) of patients, and 94% (96 of 102) were free of reintervention. Bivariate analysis showed that patients requiring reintervention had smaller absolute isthmus dimension (p = 0.04). No significant predictors for reintervention or long-term success could be identified, although a larger distal transverse arch dimension may play a role in long-term success (hazard ratio, 0.7; 95% confidence interval, 0.05 to 1.0; p = 0.06). CONCLUSIONS: Aortic arches of various dimensions were successfully repaired by lateral thoracotomy. No significant predictors for reintervention or long-term success could be identified, although the distal transverse arch dimension may play a role in long-term success.


Assuntos
Coartação Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Toracotomia/métodos , Coartação Aórtica/diagnóstico por imagem , Estudos de Coortes , Intervalos de Confiança , Ecocardiografia/métodos , Feminino , Seguimentos , Hospitais Pediátricos , Humanos , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Esternotomia/métodos , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
7.
J Am Soc Echocardiogr ; 30(12): 1225-1233, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29202952

RESUMO

BACKGROUND: Although pediatric appropriate use criteria (AUC) for outpatient transthoracic echocardiography (TTE) are available, little is known about TTE utilization patterns before their release. The aims of this study were to determine the relation between AUC and TTE utilization and to identify patient and physician factors associated with discordance between the AUC and clinical practice. METHODS: A retrospective review of 3,000 initial outpatient pediatric cardiology encounters at six centers was performed. Investigator-determined indications were classified using AUC definitions. Concordance between AUC and TTE utilization was determined. Multivariate analysis was performed to identify patient and physician factors associated with TTE's being performed for rarely appropriate and TTE's not being performed for appropriate indications. RESULTS: Concordance between AUC and TTE utilization was 88%. TTE was performed for rarely appropriate indications in 9% and was associated with patient age < 3 months, indications of murmur, noninvasive imaging physician subspecialty, and physician volume. No TTE was ordered for appropriate indications in 3% and was associated with indications including prior test result (primarily abnormal electrocardiographic findings), older patients, and physician subspecialty other than generalist or imaging. There was high variability in TTE utilization among centers. CONCLUSIONS: There was a reasonable degree of concordance between AUC and clinical practice before AUC publication. Several patient and physician factors were associated with discordance with the AUC. These findings should be considered in efforts to disseminate the AUC and in the development of future iterations. The causes for variation among centers deserve further exploration.


Assuntos
Cardiologia , Ecocardiografia/estatística & dados numéricos , Fidelidade a Diretrizes , Cardiopatias/diagnóstico , Pacientes Ambulatoriais , Padrões de Prática Médica , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
8.
J Thorac Cardiovasc Surg ; 154(3): 1038-1044, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28634025

RESUMO

OBJECTIVES: To characterize cerebral autoregulation (CA) in preoperative newborn infants with congenital heart disease (CHD). METHODS: This was a prospective, pilot study of term newborns with CHD who required intensive care. Continuous mean arterial blood pressure (MAP), cerebral tissue oxygen saturation (SCTO2) via near-infrared spectroscopy, and arterial oxygen saturation (SaO2) were collected. Significant low-frequency coherence between MAP and SCTO2 was used to define impaired CA in 20-minute epochs. Cerebral fractional tissue oxygen extraction (FTOE) = (SaO2 - SCTO2)/SaO2 was calculated. Spearman's and rank bi-serial correlations and logistic linear models accounting for multiple measures were used to identify associations with impaired CA and coherence. RESULTS: Twenty-four term neonates were evaluated for 23.4 ± 1.8 hours starting the first day of life. Periods of SaO2 variability >5% were excluded, leaving 63 ± 10 epochs per subject, 1515 total for analysis. All subjects demonstrated periods of abnormal CA, mean 15.3% ± 12.8% of time studied. Significant associations with impaired CA per epoch included greater FTOE (P = .02) and lack of sedation (P = .02), and associations with coherence included greater FTOE (P = .03), lack of sedation (P = .03), lower MAP (P = .006), and lower hemoglobin (P = .02). CONCLUSIONS: Term newborns with CHD display time-varying CA abnormalities. Associations seen between abnormal CA and greater FTOE, lack of sedation, and lower hemoglobin suggest that impaired oxygen delivery and increased cerebral metabolic demand may overwhelm autoregulatory capacity in these infants. Further studies are needed to determine the significance of impaired CA in this population.


Assuntos
Circulação Cerebrovascular/fisiologia , Cardiopatias Congênitas/fisiopatologia , Homeostase/fisiologia , Pressão Arterial/fisiologia , Feminino , Cardiopatias Congênitas/sangue , Hemoglobinas/análise , Humanos , Recém-Nascido , Masculino , Oximetria , Oxigênio/sangue , Projetos Piloto , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho , Nascimento a Termo
9.
Pediatr Cardiol ; 38(2): 381-389, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27878632

RESUMO

The aim of the study is to determine the utility of echocardiography in the assessment of diastolic function in children and young adults with restrictive cardiomyopathy (RCM). RCM is a rare disease with high mortality requiring frequent surveillance. Accurate, noninvasive echocardiographic measures of diastolic function may reduce the need for invasive catheterization. Single-center, prospective, observational study of pediatric and young adult RCM patients undergoing assessment of diastolic parameters by simultaneous transthoracic echocardiogram (TTE) and invasive catheterization. Twenty-one studies in 15 subjects [median (IQR) = 13.8 years (7.0-19.2), 60% female] were acquired with median left ventricular end-diastolic pressure (LVEDP) 21 (IQR 18-25) mmHg. TTE parameters of diastolic function, including pulmonary vein A wave duration (r s  = 0.79) and indexed left atrial volume (r s  = 0.49), demonstrated significant positive correlation, while mitral valve A (r s  = -0.44), lateral e' (r s  = -0.61) and lateral a' (r s  = -0.61) velocities showed significant negative correlation with LVEDP. Lateral a' velocity (≤0.042 m/s) and pulmonary vein A wave duration (≥156 m/s) both had sensitivity and specificity ≥80% for LVEDP ≥ 20 mmHg. In pediatric and young adult patients with RCM, lateral a' velocity and pulmonary vein A wave duration predicted elevated LVEDP with high sensitivity and specificity; however, due to technical limitations the latter was reliably measured in 12/21 patients. These noninvasive parameters may have utility in identifying patients that require further assessment with invasive testing. These findings require validation in a multicenter prospective cohort prior to widespread clinical implementation.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cardiomiopatia Restritiva/fisiopatologia , Cardiomiopatia Restritiva/terapia , Diástole , Ecocardiografia Doppler , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Velocidade do Fluxo Sanguíneo , Criança , Feminino , Humanos , Masculino , Valva Mitral/fisiopatologia , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Volume Sistólico , Adulto Jovem
10.
Cardiol Young ; 25(8): 1561-6, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26675604

RESUMO

Congenital abnormalities of the coronary arteries in the absence of structural heart disease account for a small but interesting percentage of cardiac lesions in children. Their presentation may vary from incidental identification to aborted/sudden cardiac death. Patients with aborted sudden death episodes will require significant support if they develop extensive ischaemic myocardial injury. Ultimately, surgical repair should be carried out as soon as haemodynamic stability is attained and the neurological status is evaluated. The aims of this article were to provide a review of congenital abnormalities of the coronary arteries most commonly seen in children in the ICU as well as to review the current critical-care management thereof.


Assuntos
Reanimação Cardiopulmonar , Anomalias dos Vasos Coronários/cirurgia , Cuidados Críticos/métodos , Morte Súbita Cardíaca , Procedimentos Cirúrgicos Cardíacos , Criança , Pré-Escolar , Angiografia Coronária , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico , Ecocardiografia Doppler em Cores , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Angiografia por Ressonância Magnética , Cuidados Pós-Operatórios , Tomografia Computadorizada por Raios X
11.
Circulation ; 132(6): 481-9, 2015 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-26059011

RESUMO

BACKGROUND: Ebstein anomaly and tricuspid valve dysplasia are rare congenital tricuspid valve malformations associated with high perinatal mortality. The literature consists of small, single-center case series spanning several decades. We performed a multicenter study to assess the outcomes and factors associated with mortality after fetal diagnosis in the current era. METHODS AND RESULTS: Fetuses diagnosed with Ebstein anomaly and tricuspid valve dysplasia from 2005 to 2011 were included from 23 centers. The primary outcome was perinatal mortality, defined as fetal demise or death before neonatal discharge. Of 243 fetuses diagnosed at a mean gestational age of 27±6 weeks, there were 11 lost to follow-up (5%), 15 terminations (6%), and 41 demises (17%). In the live-born cohort of 176 live-born patients, 56 (32%) died before discharge, yielding an overall perinatal mortality of 45%. Independent predictors of mortality at the time of diagnosis were gestational age <32 weeks (odds ratio, 8.6; 95% confidence interval, 3.5-21.0; P<0.001), tricuspid valve annulus diameter z-score (odds ratio, 1.3; 95% confidence interval, 1.1-1.5; P<0.001), pulmonary regurgitation (odds ratio, 2.9; 95% confidence interval, 1.4-6.2; P<0.001), and a pericardial effusion (odds ratio, 2.5; 95% confidence interval, 1.1-6.0; P=0.04). Nonsurvivors were more likely to have pulmonary regurgitation at any gestational age (61% versus 34%; P<0.001), and lower gestational age and weight at birth (35 versus 37 weeks; 2.5 versus 3.0 kg; both P<0.001). CONCLUSION: In this large, contemporary series of fetuses with Ebstein anomaly and tricuspid valve dysplasia, perinatal mortality remained high. Fetuses with pulmonary regurgitation, indicating circular shunt physiology, are a high-risk cohort and may benefit from more innovative therapeutic approaches to improve survival.


Assuntos
Anomalia de Ebstein/mortalidade , Valva Tricúspide/anormalidades , Aborto Eugênico , Adulto , Peso ao Nascer , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Síndrome de Down/complicações , Síndrome de Down/mortalidade , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/embriologia , Anomalia de Ebstein/cirurgia , Feminino , Idade Gestacional , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Mortalidade Hospitalar , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/mortalidade , Masculino , Cuidados Paliativos , Derrame Pericárdico/etiologia , Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia , Ultrassonografia Pré-Natal , Adulto Jovem
12.
J Am Soc Echocardiogr ; 28(5): 533-40, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25577184

RESUMO

BACKGROUND: Indications for intervention in early-stage (Quintero I and II) twin-twin transfusion syndrome (TTTS) are not standardized. Fetal echocardiography can be used to guide the management of early-stage patients. The aim of this study was to identify early cardiovascular findings that may precede progression to overt recipient twin (RT) cardiomyopathy in early-stage TTTS. METHODS: This was a retrospective review of pregnancies evaluated from 2004 to 2010. Subjects were included when initial evaluation identified Quintero I or II TTTS without evidence of "overt" RT cardiomyopathy, defined on the basis of atrioventricular valve regurgitation, ventricular hypertrophy, and abnormal Doppler myocardial performance indices. Patients elected management with observation or amnioreduction. Pregnancies were grouped by whether the RT developed overt cardiomyopathy. Initial values, including myocardial performance index, diastolic filling time corrected for heart rate (Doppler inflow duration/cardiac cycle length), pulsatility indices of the ductus venosus, umbilical artery, and middle cerebral artery, and cerebroplacental ratio (middle cerebral artery PI/umbilical artery PI), were compared. RESULTS: Of 174 pregnancies evaluated with early-stage TTTS, 45 (26%) did not show evidence of RT cardiomyopathy. Follow-up echocardiography identified cardiomyopathy in 20 of 45 RTs (44%). Those RTs with subsequent cardiomyopathy had shorter diastolic filling times corrected for heart rate, higher ductus venosus PIs, lower middle cerebral artery PIs, and lower cerebroplacental ratios on initial echocardiography. CONCLUSION: Diastolic dysfunction and cerebroplacental redistribution precede findings of overt cardiomyopathy in RTs with early-stage TTTS. Assessment of these parameters may allow earlier identification of RTs with cardiac disease and help guide management. Prospective studies are needed to assess the role of echocardiography in patient selection for the treatment of early-stage TTTS.


Assuntos
Cardiomiopatias/embriologia , Circulação Cerebrovascular/fisiologia , Ecocardiografia Doppler , Doenças Fetais/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/embriologia , Ultrassonografia Pré-Natal/métodos , Adulto , Cardiomiopatias/diagnóstico por imagem , Diástole , Feminino , Doenças Fetais/fisiopatologia , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/fisiopatologia , Seguimentos , Idade Gestacional , Humanos , Gravidez , Estudos Retrospectivos
13.
Cardiol Young ; 25(1): 35-41, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24107431

RESUMO

OBJECTIVES: Diagnostic ultrasound is widespread in obstetric practice, yet many babies with major congenital heart disease remain undiagnosed. Factors affecting prenatal diagnosis of major congenital heart disease are not well understood. This study aims to document prenatal detection rates for major congenital heart disease in the Greater Cincinnati area, and identify factors associated with lack of prenatal diagnosis. METHODS: All living infants diagnosed with major congenital heart disease by 4 months of age at our centre were prospectively identified. Prenatal care data were obtained by parent interview. Neonatal records were reviewed for postnatal data. Obstetricians were contacted for diagnostic ultrasound data. RESULTS: A total of 100 infants met the inclusion criteria. In all, 95 infants were analysed, of whom 94 were offered diagnostic ultrasound. In all, 41 had a prenatal diagnosis of major congenital heart disease. The rate of prenatal detection varied by cardiac lesion, with aortic arch abnormalities, semilunar valve abnormalities, and venous anomalies going undetected in this sample. Among subjects without prenatal detection, the highest proportion consisted of those having Level 1 diagnostic ultrasound only (66%). Prenatal detection was not significantly influenced by maternal race, education level, income, or insurance type. CONCLUSIONS: Despite nearly universal diagnostic ultrasound, detection rates of major congenital heart disease remain low in southwest Ohio. An educational outreach programme including outflow tract sweeps for community-level obstetrical personnel may improve detection rates.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Cuidado Pré-Natal , Diagnóstico Pré-Natal/métodos , Ultrassonografia Pré-Natal/métodos , Feminino , Humanos , Ohio , Gravidez , Estudos Retrospectivos , Fatores de Risco
14.
Circulation ; 129(21): 2183-242, 2014 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-24763516

RESUMO

BACKGROUND: The goal of this statement is to review available literature and to put forth a scientific statement on the current practice of fetal cardiac medicine, including the diagnosis and management of fetal cardiovascular disease. METHODS AND RESULTS: A writing group appointed by the American Heart Association reviewed the available literature pertaining to topics relevant to fetal cardiac medicine, including the diagnosis of congenital heart disease and arrhythmias, assessment of cardiac function and the cardiovascular system, and available treatment options. The American College of Cardiology/American Heart Association classification of recommendations and level of evidence for practice guidelines were applied to the current practice of fetal cardiac medicine. Recommendations relating to the specifics of fetal diagnosis, including the timing of referral for study, indications for referral, and experience suggested for performance and interpretation of studies, are presented. The components of a fetal echocardiogram are described in detail, including descriptions of the assessment of cardiac anatomy, cardiac function, and rhythm. Complementary modalities for fetal cardiac assessment are reviewed, including the use of advanced ultrasound techniques, fetal magnetic resonance imaging, and fetal magnetocardiography and electrocardiography for rhythm assessment. Models for parental counseling and a discussion of parental stress and depression assessments are reviewed. Available fetal therapies, including medical management for arrhythmias or heart failure and closed or open intervention for diseases affecting the cardiovascular system such as twin-twin transfusion syndrome, lung masses, and vascular tumors, are highlighted. Catheter-based intervention strategies to prevent the progression of disease in utero are also discussed. Recommendations for delivery planning strategies for fetuses with congenital heart disease including models based on classification of disease severity and delivery room treatment will be highlighted. Outcome assessment is reviewed to show the benefit of prenatal diagnosis and management as they affect outcome for babies with congenital heart disease. CONCLUSIONS: Fetal cardiac medicine has evolved considerably over the past 2 decades, predominantly in response to advances in imaging technology and innovations in therapies. The diagnosis of cardiac disease in the fetus is mostly made with ultrasound; however, new technologies, including 3- and 4-dimensional echocardiography, magnetic resonance imaging, and fetal electrocardiography and magnetocardiography, are available. Medical and interventional treatments for select diseases and strategies for delivery room care enable stabilization of high-risk fetuses and contribute to improved outcomes. This statement highlights what is currently known and recommended on the basis of evidence and experience in the rapidly advancing and highly specialized field of fetal cardiac care.


Assuntos
American Heart Association , Cardiopatias/diagnóstico , Cardiopatias/terapia , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Humanos , Gravidez , Diagnóstico Pré-Natal/métodos , Resultado do Tratamento , Estados Unidos
15.
Pediatr Res ; 74(3): 284-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23770922

RESUMO

BACKGROUND: Fetal growth abnormalities in hypoplastic left heart syndrome (HLHS) have been documented primarily by birth measurements. Fetal growth trajectory has not been described. We hypothesized that fetal growth trajectory declines across late gestation in this population. METHODS: Infants with a prenatal diagnosis of HLHS and no history of prematurity or a genetic syndrome were identified. Fetal ultrasound measurements and birth anthropometrics were obtained from clinical records. z-Scores for estimated fetal weight (EFWz) and birth weight (BWTz) were compared. BWTz for three neonatal standards were compared. RESULTS: Paired fetal and neonatal data were identified in 33 cases of HLHS. Mean gestational age at ultrasound and birth were 27 and 38 wk, respectively. BWTz was lower than EFWz by a mean of 0.82 (SD: 0.72, P < 0.0001), with 64% of subjects demonstrating a decrease in z-score of >0.5. Umbilical artery (UA) Doppler found no evidence of significant placental insufficiency. Modest differences in BWTz were seen across BWT standards in this cohort. CONCLUSION: The majority of fetuses with HLHS demonstrate decreased growth velocity during later pregnancy, suggesting growth abnormalities manifest in utero. The potential relationship to future clinical outcomes warrants further study.


Assuntos
Desenvolvimento Fetal/fisiologia , Retardo do Crescimento Fetal/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Antropometria , Peso ao Nascer , Ecocardiografia , Feminino , Retardo do Crescimento Fetal/etiologia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/complicações , Recém-Nascido , Gravidez , Ultrassonografia Pré-Natal
16.
Am Heart J ; 165(4): 544-550.e1, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23537971

RESUMO

BACKGROUND: Children with congenital heart disease are at risk for impaired neurodevelopment (ND). We investigated the association of fetal cerebrovascular resistance with ND in patients with single ventricle lesions. METHODS: In the Single Ventricle Reconstruction (SVR) and Infant Single Ventricle trials, 14-month ND was assessed using the Bayley Scales of Infant Development II. We investigated associations between ND scores and fetal middle cerebral artery pulsatility index (MCA-PI) z-scores, a Doppler-derived estimate of cerebrovascular resistance in a subset of those infants. RESULTS: Neurodevelopment assessments were performed at age 14.3 ± 1 months in 170 (74%) of 230 Infant Single Ventricle and 321 (58%) of 555 SVR subjects. Fetal echocardiographic data were available in 119 subjects, 72 (61%) of which had ND testing. Mean Psychomotor Development Index (PDI) (76 ± 20) and Mental Development Index (MDI) (89 ± 17) scores were lower than normative means (100 ± 15, P < .001). Mean MCA-PI z-score was -0.95 ± 1.52. Middle cerebral artery pulsatility index z-score correlated negatively with PDI (r = -0.27, P = .02) but was not associated with MDI. When MCA-PI z-score was added to a multivariable model controlling for factors identified in the SVR trial to predict PDI, the percentage of explained variation increased from 23% to 30%, and MCA-PI z-score remained an independent predictor (r = -3.864, P = .03). Middle cerebral artery pulsatility index z-score was not an independent predictor in a model adjusting for site. CONCLUSIONS: Among fetuses with single ventricle anomalies, lower cerebrovascular resistance was associated with higher ND scores. This relationship is opposite to that observed with advanced intrauterine growth retardation and may represent a unique ability of these congenital heart disease fetuses to compensate for diminished cerebral oxygen delivery.


Assuntos
Circulação Cerebrovascular/fisiologia , Desenvolvimento Infantil/fisiologia , Feto/fisiologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Encéfalo/metabolismo , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Artéria Cerebral Média/fisiopatologia , Análise Multivariada , Oxigênio/metabolismo , Fluxo Pulsátil , Resistência Vascular , Vasodilatação/fisiologia
17.
Anesthesiology ; 118(4): 796-808, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23343650

RESUMO

BACKGROUND: Use of high-dose inhalational anesthesia during open fetal surgery may induce maternal-fetal hemodynamic instability and fetal myocardial depression. The authors' preliminary human retrospective study demonstrated less fetal bradycardia and left ventricular systolic dysfunction with lower dose desflurane supplemented with propofol and remifentanil IV anesthesia (SIVA). In this animal study, the authors compare maternal-fetal effects of high-dose desflurane anesthesia (HD-DES) and SIVA. METHODS: Of 26 instrumented midgestational ewes, data from 11 animals exposed to both SIVA and HD-DES in random sequences and six animals exposed to HD-DES while maternal normotension was maintained were analyzed. Maternal electroencephalography was used to guide comparable depths of anesthesia in both techniques. Hemodynamic parameters, blood gas, and fetal cardiac function from echocardiography were recorded. RESULTS: Compared with SIVA, HD-DES resulted in significant maternal hypotension (mean arterial pressure difference, 19.53 mmHg; 95% CI, 17.6-21.4; P < 0.0001), fetal acidosis (pH 7.11 vs. 7.24 at 150 min, P < 0.001), and decreased uterine blood flow. In the HD-DES group with maternal normotension, uterine blood flow still declined and fetal acidosis persisted, with no statistically significant difference from the group exposed to HD-DES that had maternal hypotension. There was no statistically significant difference in fetal cardiac function. CONCLUSION: In sheep, SIVA affects maternal hemodynamics less and provides better fetal acid/base status than high-dose desflurane. Fetal echocardiography did not reflect myocardial dysfunction in this model.


Assuntos
Anestesia Obstétrica/métodos , Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Frequência Cardíaca Fetal/efeitos dos fármacos , Complicações Intraoperatórias/induzido quimicamente , Útero/efeitos dos fármacos , Equilíbrio Ácido-Base/efeitos dos fármacos , Acidose/induzido quimicamente , Anestésicos Combinados/farmacologia , Animais , Pressão Arterial/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Estudos Cross-Over , Desflurano , Eletroencefalografia/métodos , Feminino , Feto , Isoflurano/análogos & derivados , Isoflurano/farmacologia , Monitorização Intraoperatória/métodos , Piperidinas/farmacologia , Gravidez , Propofol/farmacologia , Fluxo Sanguíneo Regional/efeitos dos fármacos , Remifentanil , Ovinos , Útero/irrigação sanguínea
18.
Pediatr Dev Pathol ; 15(1): 79-85, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21875340

RESUMO

Ductus arteriosus aneurysm (DAA) is a rare cardiovascular lesion usually diagnosed within the first 2 months of life, or less frequently in the 3rd trimester, by antenatal sonography. The true in utero incidence of DAA is unknown, as most affected fetuses are asymptomatic at birth. Potential complications include thromboembolism, rupture, and death. We report a unique lethal case of a large DAA detected by mid-2nd trimester fetal echocardiography, complicated by stricture and massive occlusive thrombosis extending into the pulmonary artery branches. Stricture and thrombosis of the DAA led to interruption of fetal circulation, cardiac failure, and fetal hydrops, ultimately resulting in fetal demise.


Assuntos
Aneurisma/diagnóstico , Canal Arterial/patologia , Hidropisia Fetal/patologia , Artéria Pulmonar/anormalidades , Trombose Venosa/diagnóstico , Aneurisma/complicações , Constrição Patológica/complicações , Constrição Patológica/congênito , Constrição Patológica/diagnóstico , Canal Arterial/embriologia , Evolução Fatal , Feminino , Morte Fetal , Humanos , Hidropisia Fetal/etiologia , Gravidez , Segundo Trimestre da Gravidez , Diagnóstico Pré-Natal , Artéria Pulmonar/embriologia , Trombose Venosa/complicações , Trombose Venosa/congênito , Adulto Jovem
19.
J Pediatr ; 159(5): 761-5, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21676411

RESUMO

OBJECTIVES: To describe congenital heart disease death rates in infants born between 34 and 40 weeks, estimate the relationship between gestational age and congenital heart disease infant death rates, and compare congenital heart disease death rates across 1- and 2-week intervals in gestational age. STUDY DESIGN: The 2000 to 2003 national linked birth/infant death cohort datasets were obtained. Congenital heart disease deaths were identified by using International Statistical Classification of Diseases, 10th Revision codes. Proportional death rates were calculated by using congenital heart disease deaths and all live births. The relationship between congenital heart disease death rates and gestational age was determined. Death rates were compared across intervals. RESULTS: A total of 14.9 million records were analyzed. Congenital heart disease deaths occurred in 4736 infants (0.04%) born between 34 and 40 weeks. There was a significant, negative linear relationship between congenital heart disease death rate and gestational age (R(2) = 0.97). Comparisons across 1-week intervals varied (P = .02-.23). All 2-week intervals were statistically significant (P < .01). CONCLUSIONS: Congenital heart disease death rates decrease as gestational age approaches 40 weeks. These results should be considered before elective delivery for the sole indication of prenatally diagnosed congenital heart disease.


Assuntos
Idade Gestacional , Cardiopatias Congênitas/mortalidade , Estudos de Coortes , Interpretação Estatística de Dados , Humanos , Recém-Nascido , National Center for Health Statistics, U.S. , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...