Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 12(14): 1033-1038, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32706625

RESUMO

In this paper, the European Bioanalysis Forum reports back from the discussions with software developers, involved in regulated bioanalysis software solutions, on agreeing to data transfer specification in the bioanalytical labs' LC-MS workflows as part of today's Data Integrity (DI) challenges. The proposed specifications aim at identifying what consists of a minimum dataset, that is, which are the pre-identified fields to be included in DI proof bidirectional data transfer between LC-MS and information management systems. The proposal is an attempt from the European Bioanalysis Forum to facilitate new software solutions becoming available to increase compliance related to DI in today's LC-MS workflows. The proposal may also serve as a template and inspiration for new data transfer solutions in other workflows.


Assuntos
Bioensaio/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Europa (Continente) , Humanos
2.
Bioanalysis ; 11(13): 1227-1231, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31452404

RESUMO

In this conference report, we summarize the main findings and messages from a workshop on 'Data Integrity'. The workshop was held at the 11th European Bioanalysis Forum Open (EBF) Symposium in Barcelona (21-23 November 2018), in collaboration with the Medicines and Health products Regulatory Agency to provide insight and understanding of regulatory data integrity expectations. The workshop highlighted the importance of engaging with software developers to address the gap between industry's data integrity needs and current system software capabilities. Delegates were also made aware of the importance of implementing additional procedural controls to mitigate the risk associated with using systems that do not fully meet data integrity requirements.


Assuntos
Bioensaio , Preparações Farmacêuticas/análise , Bioensaio/normas , Confiabilidade dos Dados , Regulamentação Governamental , Preparações Farmacêuticas/normas , Controle de Qualidade
3.
Bioanalysis ; 10(21): 1723-1732, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30412676

RESUMO

With 10 years of experiences on incurred sample reanalysis (ISR) as an integrated part of regulated bioanalysis, the European Bioanalysis Forum has reflected on the implementation and the use of ISR. Three surveys were conducted in 2016 and 2017 as a revisit of the ISR experiences within European pharmaceutical industry and contract research organizations: has ISR become a tool for postvalidation and process check of a bioanalytical method performance and has ISR become a routine in our laboratories? Do we agree on the interpretation of guidelines/guidance and are we aligned in our approach - among others?


Assuntos
Desenvolvimento de Medicamentos , Indústria Farmacêutica , Controle de Qualidade , Reprodutibilidade dos Testes , Animais , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Desenvolvimento de Medicamentos/métodos , Desenvolvimento de Medicamentos/normas , Indústria Farmacêutica/métodos , Indústria Farmacêutica/normas , Europa (Continente) , Humanos , Farmacocinética , Testes de Toxicidade/métodos , Testes de Toxicidade/normas , Estudos de Validação como Assunto
5.
Bioanalysis ; 9(9): 683-692, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28520466

RESUMO

AIM: Development of a high-sensitivity chiral LC-MS/MS method was required to evaluate a combination of pramipexole (S-PPX) and its enantiomer dexpramipexole (R-PPX) in a proposed clinical trial. The previously available methods suffered from low sensitivity for the (S)-enantiomer in the presence of the more abundant (R)-enantiomer. Based on the projected dosing regimen in the clinical trial, a 5000-fold improvement in sensitivity was required for the (S)-enantiomer. METHODOLOGY: Spiked human plasma samples were extracted by liquid-liquid extraction using ethyl acetate and injected onto a CHIRALPAK ID column under pH gradient conditions. CONCLUSION: An improved analytical method was developed and validated with a final LLQ for (S)-PPX of 0.1 ng/ml in the presence of 2000 ng/ml of (R)-PPX.


Assuntos
Antiparkinsonianos/sangue , Benzotiazóis/sangue , Agonistas de Dopamina/sangue , Extração Líquido-Líquido/métodos , Espectrometria de Massas em Tandem/métodos , Antiparkinsonianos/isolamento & purificação , Benzotiazóis/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Agonistas de Dopamina/isolamento & purificação , Humanos , Limite de Detecção , Pramipexol , Reprodutibilidade dos Testes
6.
Bioanalysis ; 2(11): 1863-71, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21083494

RESUMO

BACKGROUND: One of the main reasons for the increased popularity of dried blood spots (DBS) is related to the 3Rs principles (replacement, refinement and reduction) for animal use in drug development. The small blood volume collected using this technique may have a significant impact on the assay sensitivity. An approach that made use of hydrophilic interaction chromatography (HILIC) to enhance the LC-MS assay sensitivity was explored and optimized for a tool compound. RESULTS: A very high-sensitivity assay in dried spots of human blood was validated in the range of 5 to 5000 pg/ml. The use of HILIC increased LC-MS sensitivity up to fivefold compared with other reversed phase chromatographic methods. CONCLUSION: The good compatibility of the DBS extracts with HILIC and the results of the assay validation for zatebradine at a very low LLOQ demonstrate the high potential and the high performance of this approach.


Assuntos
Benzazepinas/sangue , Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Benzazepinas/isolamento & purificação , Dessecação , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Modelos Lineares , Sensibilidade e Especificidade
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(29): 2974-82, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20870467

RESUMO

A sensitive, selective and quantitative method for the simultaneous determination of casopitant, a potent and selective antagonist of the human Neurokinin 1 (NK-1) receptor, and its three major metabolites M12, M13 and M31 was developed and validated in dog and rat plasma. Acetonitrile containing stable labeled internal standards for the four analytes was used to precipitate proteins in plasma. Chromatographic separation was obtained using a reversed phase column with multiple reaction monitoring turboionspray positive ion detection. The lower and upper limits of quantification for casopitant and its metabolites were 15 and 15,000 ng/mL, using a 50 µL of dog or rat plasma aliquot, respectively. The inter-day precision (relative standard deviation) and accuracy (relative error) in dog plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 4.1% to 10.0% and -10.8% to 8.7%, respectively, for casopitant and its 3 major metabolites. The intra-day precision (relative standard deviation) and accuracy (relative error) in rat plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 3.9% to 6.6% and -9.6% to 8.3%, respectively, for casopitant and its three metabolites. All analytes were found to be stable in analytical solutions for at least 43 days at 4°C, in dog and rat plasma at room temperature for at least 24 h, at the storage temperature of -20°C for at least 6 months, and following the action of three freeze-thaw cycles from -20°C to room temperature. All analytes were also found to be stable in processed extracts at 4°C for at least 72 h. This assay proved to be accurate, precise, fast and was used to support long-term toxicology studies in dog and rat.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Piperazinas/sangue , Piperazinas/metabolismo , Piperidinas/sangue , Piperidinas/metabolismo , Espectrometria de Massas em Tandem/métodos , Animais , Cães , Antagonistas dos Receptores de Neurocinina-1 , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...