Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38661603

RESUMO

BACKGROUND: Management of acute myocarditis (AM) patients experiencing ventricular arrhythmia (VA) during acute illness is controversial, especially regarding early implantable cardioverter-defibrillator (ICD) implantation. OBJECTIVES: The purpose of this study was to evaluate the prevalence of and find predictors for long-term sustained VA recurrence and overall mortality among AM patients with VA. METHODS: This was a multicenter retrospective analysis of AM patients (verified by cardiac magnetic resonance imaging or myocardial biopsy) with documented VA during the acute illness ("initial VA"). Patients with history of myocardial infarction, heart failure, or VA were excluded. The study endpoint was a composite of sustained VA and overall mortality during follow-up. RESULTS: The study included 69 AM patients with initial VA: sustained monomorphic ventricular tachycardia (MMVT) (n = 25), sustained polymorphic ventricular tachycardia (VT)/ventricular fibrillation (n = 13), and nonsustained VT (n = 31). Age was 44 ± 13 years, and 23 of 69 (33.3%) were women. During median follow-up of 5.5 years, 27 of 69 (39%) patients reached the composite endpoint including sustained VA (n = 24) and death (n = 11). Initial MMVT, predischarge left ventricular dysfunction (left ventricular ejection fraction <50%), and anteroseptal delayed enhancement on cardiac magnetic resonance imaging were significantly associated with the composite endpoint. On multivariable analysis, initial MMVT (HR: 5.17; 95% CI: 1.81-14.6; P = 0.001) and predischarge LV dysfunction (HR: 4.57; 95% CI: 1.83-11.5; P = 0.005) were independently associated with the composite endpoint. Using these 2 predictors, we could delineate subgroups with low (∼4%), medium (∼42%), and high (∼82%) 10-year incidence of composite endpoint. CONCLUSIONS: AM patients presenting with VA have high incidence of sustained VA recurrence and mortality posthospitalization. Initial MMVT and predischarge LV dysfunction are independently associated with VA recurrence and mortality. Implantable cardioverter-defibrillator implantation may be considered in such high-risk patients.

3.
Am J Cardiol ; 211: 17-28, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37879381

RESUMO

The current guidelines advocate prophylactic implantable cardioverter-defibrillator (ICD) for all patients with symptomatic heart failure (HF) with low left ventricular ejection fraction. Because many patients will never use their device, a score delineating subgroups with differential ICD benefit is crucial. We aimed to evaluate the MADIT-II-based Risk Stratification Score (MRSS) feasibility to delineate the ICD survival benefit in a nationwide registry of patients with HF with prophylactic ICDs. Accordingly, all Israeli patients with HF with prophylactic ICD/cardiac resynchronization therapy defibrillators were categorized into MRSS-based risk subgroups. The study end points included overall mortality, sustained ventricular arrhythmia (VA), and a competing risk of VA (potential preventable arrhythmic death, where ICD could benefit survival) versus nonarrhythmic death. Potential ICD survival benefit was estimated by the area between these cumulative incidence curves. In 2,177 patients with HF implanted prophylactic device, 189 patients (8.7%) had VA and 316 (14.5%) died during a median follow-up of 2.9 years. The MRSS risk subgroups were significantly associated with overall mortality (p <0.001) and weakly with VA (p = 0.3). The competing risk analysis of VA versus nonarrhythmic death revealed a significantly shorter duration (p <0.001) and smaller magnitude of ICD survival benefit with increased risk subgroups, yielding an estimated 76, 60, 38, and 0 life days gained from prophylactic ICD implant during a 5-year follow-up for the MRSS low-, intermediate-, high-, and very high-risk subgroups, respectively (p for trend <0.05). In conclusion, MRSS use in a nationwide registry of patients with ischemic and nonischemic cardiomyopathy, revealed subgroups with differing ICD survival benefit, suggesting it could help evaluate prophylactic ICD survival benefit.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda , Fatores de Risco , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Medição de Risco , Sistema de Registros , Prevenção Primária , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622591

RESUMO

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Assuntos
Fármacos Cardiovasculares , Humanos , Eletrônica , Coração , Tecnologia , Gerenciamento Clínico
5.
J Clin Med ; 12(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36983442

RESUMO

BACKGROUND: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. AIM: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. METHODS AND RESULTS: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). CONCLUSION: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.

6.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36635857

RESUMO

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Assuntos
Cardiomiopatias , Taquicardia Ventricular , Humanos , Bloqueio de Ramo , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/complicações , Ventrículos do Coração , Eletrocardiografia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
8.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225168

RESUMO

AIMS: Conduction abnormalities post-transcatheter aortic valve implantation (TAVI) are common. Post-TAVI PR prolongation was mainly studied as an adjunct to new-onset bundle branch block. The net effect of isolated PR prolongation (IPRP) without post-TAVI QRS changes is not well known. The aim of this study was to define the incidence and clinical significance of post-TAVI IPRP. METHODS AND RESULTS: A total of 1108 consecutive TAVI patients were reviewed. Patients with IPRP were compared with patients without post-TAVI electrocardiogram (ECG) changes. Clinical outcomes included permanent pacemaker implantation (PPI) and overall mortality. A total of 146 patients with IPRP were compared with 290 patients without post-TAVI ECG changes. At 1 year follow-up, 4 (2.7%) and 7 (2.4%) patients underwent PPI (P = 0.838) and 10 (6.8%) and 25 (8.6%) died (P = 0.521), from the study and control groups, respectively. No patient with IPRP and narrow QRS underwent PPI during 1 year post-TAVI, and all death events were non-cardiac except one unknown cause. Permanent pacemaker implantation rates among patients with IPRP and wide QRS were higher (n = 4, 12.1%), compared with patients with wide QRS without post-TAVI ECG change (n = 3, 4%) however not reaching statistical significance (P = 0.126). Multivariate Cox proportional hazards model demonstrated that in patients with narrow QRS, neither PR prolongation nor baseline or maximal PR intervals was associated with the combined endpoint of PPI and mortality. However, in patients with wide QRS, baseline PR intervals and QRS width, but not PR prolongation were associated with the combined outcome. CONCLUSION: Post-TAVI IPRP in patients with narrow QRS is not associated with adverse outcome. This finding may translate clinically into a more permissive approach to these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Incidência , Relevância Clínica , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Eletrocardiografia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
9.
Harefuah ; 161(7): 454-457, 2022 Jul.
Artigo em Hebraico | MEDLINE | ID: mdl-35833433

RESUMO

INTRODUCTION: For many years routine screening of athletes in Israel includes frequently performed ECGs and exercise tests that overload the system with questionable benefits. The purpose of the current document is to reevaluate the need for pre-participation testing and establish new evidence-based guidelines. It should be noted that our proposal for a change of approach relates only to subjects whose health questionnaire is normal, who do not have a family history of sudden and unexpected death at an early age, or a family history of hereditary heart disease and whose physical examination from a cardiovascular point of view is normal.


Assuntos
Doenças Cardiovasculares , Esportes , Atletas , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/prevenção & controle , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Humanos , Israel , Programas de Rastreamento , Exame Físico , Organização Mundial da Saúde
14.
J Cardiovasc Electrophysiol ; 33(4): 618-625, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118762

RESUMO

BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Computadores , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X
15.
Europace ; 24(5): 817-827, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34652415

RESUMO

AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads. METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success. CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
17.
Europace ; 24(1): 165-172, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34455442

RESUMO

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Marca-Passo Artificial , Adulto , Comitês Consultivos , Terapia de Ressincronização Cardíaca/efeitos adversos , Humanos , Indicadores de Qualidade em Assistência à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...